Claim Missing Document
Check
Articles

Optimal Design of Hydrogen Based Wind-Microhydro Using Genetic Algorithm Soedibyo Soedibyo; Heri Suryoatmojo; Imam Robandi; Mochamad Ashari
Indonesian Journal of Electrical Engineering and Computer Science Vol 10, No 6: October 2012
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The target of stand-alone hybrid power generation system was to supply the load demand with high reliability and economically as possible. To design these criteria the optimal design of the proposed configuration should be done by using intelligent optimization technique.  This study utilized Genetic Algorithm method to determine the optimal capacities of hydrogen, wind turbines and micro hydro unit according to the minimum cost objective functions that relate to these two factors. In this study, the cost objective function included the annual capital cost, annual operation maintenance cost, annual replacement cost and annual customer damage cost. The proposed method had been tested in the hybrid power generation system located in Leuwijawa village in Central Java of Indonesia. Simulation results showed that the optimum configuration can be achieved using 19.85 ton of hydrogen tanks, 21 x 100 kW wind turbines and 610 kW of micro hydro unit respectively. DOI: http://dx.doi.org/10.11591/telkomnika.v10i6.1326
Intelligent voltage controller based on firefly algorithm for DC-DC boost converter Darmansyah Darmansyah; Imam Robandi
Indonesian Journal of Electrical Engineering and Computer Science Vol 28, No 2: November 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v28.i2.pp735-743

Abstract

DC-DC boost converter is one of the important tools of photovoltaic (PV) power plant. DC-DC boost converter can be used to adjust the voltage output of photovoltaic before going to the inverter. In addition, DC-DC boost converter can be used as additional devices to make the PV plant operated in maximum power point condition. To get the optimal voltage adjusment, an appropriate controller is essential. Generally, PI controller is commonly used to control the switching procedure of the boost converter. However, with uncertainty of the source (uncertainty of the PV output), PI controller is out off dated. Hence designing PI controller based on the metaheuristic algorithm such as firefly algorithm is essential. This paper is proposed an intelligent voltage controller for DC-DC boost converter based on firefly algorithm (FA). From the simulation results it is noticeable that the PI based on FA could provide better control signal (indicated by the fastest settling time of the boost converter).
PENINGKATAN STABILITAS SISTEM SULSELRABAR DENGAN DUAL INPUT POWER SYSTEM STABILIZER PADA KONTINGENSI N-1 Muhammad Ruswandi Djalal; Imam Robandi
MEDIA ELEKTRIKA Vol 15, No 2 (2022): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26714/me.v15i2.10788

Abstract

Studi kontingensi system tenaga adalah hal yang sangat penting, karena sistem harus dirancang dan dioperasikan sehingga apabila terjadi kontingensi (N-1) atau lepasnya suatu elemen sistem baik generator maupun saluran transmisi tidak akan mengalami kehilangan beban. Penelitian tentang analisis kontingensi N-1 pada sistem tenaga listrik perlu dilakukan, karena memiliki karakteristik yang berbeda dengan kondisi saat sistem beroperasi secara normal. Ketidakstabilan sistem Sulselrabar dalam kondisi normal akan menjadi acuan bagi peneliti untuk membahas kondisi sistem saat sistem tidak beroperasi secara normal seperti kontingensi N-1. Analisis kontingensi N-1 di sini berada di tengah-tengah garis Sidrap-Maros. Garis tengah Sidrap-Maros adalah garis yang menghubungkan daerah-daerah pusat beban. Salah satu metode yang diusulkan disini adalah penambahan Dual Input Power System Stabilizer (DIPPS). Dari hasil simulasi didapatkan kinerja sistem Sulselrabar saat kontingensi N-1 lebih optimal dengan menggunakan DIPSS, hal tersebut ditinjau dari karakteristik osilasi kecepatan generator yang minimum, deviasi respon sudut rotor yang baik, serta nilai eigenvalue yang semakin negatif. Untuk membandingkan kinerja sistem yang diusulkan, digunakan PSS konvensional dengan satu input.
Implementasi dan Sosialisasi Mini Laboratorium Sistem Pembangkit Tenaga Surya di SMK Muhammadiyah 7 Gondanglegi Robandi, Imam; Candra Riawan, Dedet; Wirjodirdjo, Budisantoso; Guntur, Harus Laksana; Putri, Vita Lystianingrum Budiharto; Djalal, Muhammad Ruswandi; Prakasa, Mohamad Almas; Ghazi, Argon Luthfan; Irsad, Muh. Afif Al; Hidayat, Muh. Taufik Imam; Saputra, Reki Aji; Kumala, Arimbi; Satria, Moch. Adri; Himawari, Waseda
Sewagati Vol 8 No 1 (2024)
Publisher : Pusat Publikasi ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j26139960.v8i1.793

Abstract

Indonesia memiliki potensi energi baru terbarukan (EBT) yang sangat besar, namun belum diikuti dengan pemanfaatan yang optimal. Sistem Listrik Tenaga Surya (PLTS) berbasis fotovoltaik menjadi teknologi yang paling mudah diimplementasikan oleh semua kalangan dan di berbagai sektor. Di sektor Pendidikan, Sekolah Menengah Kejuruan (SMK) memiliki visi membentuk sumber daya manusia yang memiliki kompetensi keahlian di bidang tertentu, salah satunya teknik instalasi tenaga listrik. Meski begitu, belum banyak SMK yang sudah mulai memperkenalkan pentingnya pemanfaatan EBT pada siswanya. Pada kegiatan Pengabdian Kepada Masyarakat (Abmas) ini diusulkan Implementasi dan Sosialisasi Mini Laboratorium Sistem Pembangkit Tenaga Surya sebagai Media Pembelajaran di SMK Muhammadiyah 7 Gondanglegi, Malang. Mini Laboratorium ini terdiri dari Trainer PLTS yang merupakan mereplika sistem PLTS stand-alone dalam skala laboratorium yang cukup untuk proses pembelajaran. Trainer PLTS ini terdiri dari sistem fotovoltaik, beserta komponen pendukung berupa Solar Charger Controller (SCC), baterai, dan inverter. Metode pelaksanaan kegiatan meliputi implementasi dan sosialisasi mini laboratorium. Dari hasil pelaksanaan abmas diperoleh peningkatkan pemahaman dan keterampilan para siswa dan guru terkait pemanfaatan teknologi EBT dalam bentuk trainer PLTS.
Pemodelan Peramalan Beban pada System Sulselrabar Menggunakan Tipe-2 Logika Fuzzy Djalal, Muhammad Ruswandi; Robandi, Imam
Jurnal Teknologi Elekterika Vol. 19 No. 2 (2022): Nopember
Publisher : Jurusan Teknik Elektro Politeknik Negeri Ujung Pandang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31963/elekterika.v6i2.3751

Abstract

Penelitian ini mengusulkan pendekatan pemodelan untuk peramalan beban jangka pendek 24 jam berdasarkan logika fuzzy tipe-2. Dalam penelitian ini didapatkan suatu pendekatan dalam merancang model peramalan beban, dimana sebelumnya masih menggunakan logika fuzzy konvensional. Implementasi peramalan beban pada penelitian ini dilakukan pada sistem kelistrikan 150 kV Sulselrabar. Sistem kelistrikan Sulselrabar dalam perkembangannya mengalami perkembangan yang pesat, oleh karena itu diperlukan suatu penelitian yang dapat meningkatkan performansi sistem tersebut, salah satunya adalah studi peramalan beban jangka pendek. Sebagai data input digunakan data beban dari tahun 2010 sampai dengan tahun 2016 pada hari yang sama yaitu tanggal 8 Januari. Untuk melihat keakuratan hasil, dilakukan dua pendekatan, yaitu logika fuzzy tipe-1 yang dimodelkan menggunakan Simulink dan logika fuzzy tipe-2 dengan menggunakan m-file Matlab. Dari hasil analisis diperoleh Mean Percentage Error (MAPE) paling kecil dengan menggunakan metode Fuzzy Logic Type-2, dibandingkan dengan metode Fuzzy Logic Type-1. Dimana, MAPE untuk metode fuzzy logic tipe-1 adalah 2.1%, dan dengan menggunakan metode logika fuzzy tipe-2, MAPE adalah 1.7%.
Implementasi Trainer PLTS sebagai Media Pembelajaran di SD Muhammadiyah 4 Surabaya Robandi, Imam; Guntur, Harus Laksana; Wirjodirdjo, Budisantoso; Djalal, Muhammad Ruswandi; Prakasa, Mohamad Almas; Ramadhani, Akhmad; Imam, Muhammad Taufik; Dian, Faizal; Al Irsad, Muhammad Afif; Muchyiddin, Muhammad Imam; Imron, Khafit; Natha, Kanidra; Kurniawan, Muhammad; Aulia, Dzacky; Himawari, Waseda; Haque, Gabriel
Sewagati Vol 8 No 6 (2024)
Publisher : Pusat Publikasi ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j26139960.v8i6.2240

Abstract

Sistem Pembangkit Listrik Tenaga Surya (PLTS) berbasis fotovoltaik merupakan teknologi yang paling mudah diimplementasikan oleh berbagai kalangan. PLTS memiliki berbagai aplikasi di sektor-sektor seperti perumahan, industri, dan lingkungan akademik. Lingkungan akademik dianggap sebagai tempat yang ideal untuk eksperimen test-bed karena banyaknya akademisi yang memiliki semangat dan kemampuan yang tinggi. Oleh karena itu, pengenalan Energi Baru Terbarukan (EBT) perlu diperkuat di tingkat pendidikan dasar, khususnya di Sekolah Dasar (SD). Tujuannya adalah untuk mempersiapkan sumber daya manusia yang mulai tertarik dalam pengembangan teknologi EBT sejak dini. Dalam kegiatan pengabdian ini, diusulkan program Pengabdian Kepada Masyarakat (PKM) yang menerapkan trainer PLTS sebagai media pembelajaran di SD Muhammadiyah 4 (Mudipat) Surabaya. Tujuan dari pengabdian ini adalah mendukung proses pengembangan dan pembelajaran bagi siswa dan tenaga pendidik, serta mensosialisasikan pentingnya EBT kepada masyarakat. Trainer PLTS ini merupakan replika sistem PLTS stand-alone dalam skala laboratorium yang cukup untuk keperluan pembelajaran. Trainer ini terdiri dari tiga modul, yaitu modul kontrol utama, modul solar panel, dan modul lampu halogen. Metode pelaksanaan kegiatan mencakup sosialisasi dan implementasi trainer PLTS. Hasil dari pelaksanaan program ini menunjukkan peningkatan pemahaman dan keterampilan siswa serta guru terkait pemanfaatan teknologi EBT melalui trainer PLTS.
Mixed-Integer Linear Programming for Optimal Operation of Integrated Electricity and Natural Gas System Considering Take or Pay Agreements Nooraini, Ervina; Prakasa, Mohamad Almas; Djalal, Muhammad Ruswandi; Wibowo, Rony Seto; Robandi, Imam
JUTI: Jurnal Ilmiah Teknologi Informasi Vol.23, No.2, July 2025
Publisher : Department of Informatics, Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j24068535.v23i2.a1265

Abstract

This paper is proposed to demonstrate the implementation of Mixed-Integer Linear Programming (MILP) for solving the optimal operation of the Integrated Electricity and Natural Gas System (IENGS). The MILP is used to realize an economical and reliable power electricity system based on Dynamic Optimal Power and Gas Flow (DOPGF) considering Take or Pay (TOP) agreements for natural gas. This method is simulated on the integrated 6-bus electricity and 6-node natural gas systems. By using MILP, the best costs for optimal operation of IENGS are obtained in three scenarios. The superiority of the MILP is validated by suppressing the increasing best cost for optimal operation to be below 10%. In the first case, the best cost is $735,405.37 without the TOP agreement. In the second scenario, the best cost ranges from $748,399.30 to $760,320.57 with the TOP agreement implemented in one-by-one generators, which is 1.77% to 3.39% higher than the first scenario. In the third case, the best cost is $791,833.04 with the TOP agreement in all of the generators, which is 7.67% higher than the first scenario. In addition, the MILP can perform the DOPGF for IENGS without violating the problem constraints regarding the load demand fulfillment and power system limitations in both coal-fired and gas-fired generators.                                                        
Optimasi DF Berbasis Posisi Jendela Menggunakan Estetika Asimetris Rizal, Yose; Robandi, Imam; Yuniarno, Eko Mulyanto
Jurnal Teknologi Informasi dan Ilmu Komputer Vol 7 No 3: Juni 2020
Publisher : Fakultas Ilmu Komputer, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25126/jtiik.2020733160

Abstract

Jendela merupakan elemen arsitektur yang berfungsi memasukan pencahayaan alami dari luar kedalam bangunan. Distribusi pencahayaan siang yang merata masuk kedalam ruangan dapat meminimalkan penggunaan pencahayaan buatan. Penelitian ini dilakukan untuk mencari optimasi posisi jendela dengan pendekatan kepada distribusi jarak daylight factor (DF) dan estetika komposisi spasial. Analisis dilakukkan berdasarkan kualitatif distibusi DF pada ruangan terhadap posisi bukaan jendela secara estetika komposisional beradasarkan grafik teori kecocokan represetasional. Tahap fitting dan normalisasi pada nilai daylight factor dan estetika asimetri dari teori kecocokan represetasional merupakan langkah awal untuk mendapatakan optimasi nilai faktor yang nantinya akan diberikan suatu nilai faktor bobot ( ) untuk kedua variabel. Hasil studi di dapat  posisi jendela paling optimal berada pada posisi jarak 23% dari lebar bidang dinding bukaan jendela terhadap sisi jendela bagian dalam, dimana nilai faktor bobot  = 0,5. Optimasi dengan menggunakan nilai  dapat digunakan arsitek untuk menentukkan distribusi DF, estetika asimetri atau bahkan keduanya. AbstractThe window is an architectural element that functions to incorporate natural lighting from outside into the building. Even daylight distribution into the room can minimize the use of artificial lighting. This research was conducted to find window position optimization by approaching the daylight factor (DF) distance distribution and spatial composition aesthetics. The analysis was carried out based on the qualitative distribution of DF in the room to the position of the window opening aesthetically compositional based on a graph of the theory of repetational compatibility. The fitting and normalization phase of DF values and the asymmetry aesthetics of the repetational match theory are the first step to get an optimization of the factor values which will be given a weight factor value (α) for both variables. The results of the study in the most optimal window position can be located at a distance of 23% from the width of the window opening wall area to the inner side of the window, where the weight factor value α = 0.5. Optimization using the  can be used by architects to determine the distribution of DF, asymmetry aesthetics or even both.
Co-Authors Adi Soeprijanto Afif Nur Wahyudi Agus Dharma Ahmad Zakaria Hizbullah Akbar Swandaru Al Irsad, Muhammad Afif Alfredo Gusmao Ali Musyafa Andi Imran Angga Prasetya Ardyono Priyadi Atiqah Hilmy Raditya Aulia, Dzacky Bedy Kharisma Benny Prastikha Hadhi Budisantoso Wirjodirdjo Candra Riawan, Dedet Darmansyah Darmansyah Dedet Candra Riawan Dewi Anugrah Rizqi Dian, Faizal Dwi Ajiatmo Dwi Ajiatmo Dwi Ajiatmo Dwi Ajiatmo Dwi Didit Prasetiyo Dwi Lastomo Eko Mulyanto Yuniarno Elza Dwi Rachmayanti Fachrudin Hunaini Farid Dwi Murdianto Firdaus Firdaus Ghazi, Argon Luthfan Gita Dwipermata Sari Haque, Gabriel Harus Laksana Guntur Heri Suryoatmojo Herlambang Setiadi Heryanto Hartra M M Heryanto Hartra M M Hidayat, Muh. Taufik Imam Hidayatul Nurohmah Himawari, Waseda I Made Yulistya Negara I Nyoman Adi Putra Imam, Muhammad Taufik Imron, Khafit Irfan Rashidi Irsad, Muh. Afif Al Kumala, Arimbi Machrus Ali Mauridhi Hery Purnomo Mochamad Ashari Muchyiddin, Muhammad Imam Muhammad Kurniawan Muhammad Ruswandi Djalal Muhammad Siddiq Basid Muhammad Taufiq Ramadhan Muhammad Yusuf Mappeasse Natha, Kanidra Nooraini, Ervina Nur Atiqah Rianty Sari Nyoman Sutantra Ontoseno Penangsang Ontoseno Penangsang Prakasa, Mohamad Almas Pujiantara, Margo R. Dwi Cahyo Ramadhani, Akhmad Ramadoni Syahputra Rodhi Kelvianto Rony Seto Wibowo Rony Seto Wibowo Saputra, Reki Aji Satria, Moch. Adri SATRIYAS ILYAS Seno Aji Seno Aji Sidaryanto Sidaryanto Sjamsjul Anam Soedibyo Soedibyo Soedibyo Soedibyo Suharto Suharto Teguh Yuwono Vita Lystianingrum Wendy Kurniawan Kautsar Yose Rizal Yose Rizal Zainal Abidin