Publikasi Riset Orientasi Teknik Sipil (Proteksi)
Publikasi Riset Orientasi Teknik Sipil (Proteksi), ISSN No. 2655-6421 is a venue for publicizing scientific research activities in the field of Civil Engineering, necessarily restricted to structures, geotechnic and earthquakes, transportation, highway and railway, construction materials, water resources, hydrology and hydraulic, environment, surveying, monitoring and control systems, health and safety in construction. Proteksi is a peer-reviewed journal that is published by Universitas Negeri Surabaya or the State University of Surabaya in collaboration with Himpunan Ahli Teknik Tanah (HATTI) Cabang Jatim or Soil Engineering Expert (HATTI) East Java Branch. Proteksi is published by the Department of Civil Engineering, Faculty of Engineering, State University of Surabaya - Indonesia with publishing period twice in a year. The articles published in Proteksi been through the editing process and rigorous assessment of third parties who joined as a mitra bebestari. This editing process aims to ensure the accuracy of the content of the article as well as guarantee the accuracy of information as expected by the reader. The article published in Proteksi be accessible online and can be downloaded without charge (free of charge). We invite researchers, academics, and practitioners to publish research results in this journal. The language used in this journal is English and Bahasa Indonesia. Proteksi published by the Department of Civil Engineering, Faculty of Engineering, Universitas Negeri Surabaya (Unesa), Surabaya, East Java, Indonesia. Proteksi published twice a year, in Juni and December, Proteksi includes research in the field of Structures, Geotechnic and Earthquakes, Construction Management, Transportation, Highway and Railway , Construction Materials, Water Resources, Hydrology and Hydraulics, Environment, Surveying, Monitoring, and Control Systems, Health and Safety in Construction. Editors invite research lecturers, the reviewer, practitioners, industry, and observers to contribute to this journal.
Articles
153 Documents
Analisis Pemanfaatan Serbuk Cangkang Telur Terhadap Kuat Tekan Beton Geopolimer: Analysis of Egg Shell Powder Utilization on the Compressive Strength of Geopolymer Concrete
Sinta Devi, Debby;
Risa Destania, Henggar;
Rizky Cahyadi, Muhammad
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 2 (2024): Vol. 6 No. 2 (2024)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v6n2.p223-227
The recent development of rapid infrastructure has led to an increase in the application of concrete as the main construction material. Concrete has several virtues, such as high compressive strength, durability, and fire resistance, although its use can have environmental impacts, especially related to carbon emissions from cement production. Geopolymer concrete is an alternative environmentally friendly material that does not require Portland cement. Geopolymer concrete uses an alkaline liquid to react with silica and aluminum from materials such as fly ash and eggshell powder. Fly ash and eggshells, which are industrial and domestic wastes, can be recycled to replace cement, reducing the environmental impact of concrete construction. This study evaluates the utilization of eggshell powder and fly ash on the compressive strength of geopolymer concrete using variations of 40:60, 50:50 and 60:40. The compressive strength test results show that geopolymer concrete with 0% eggshell powder is 30.77 MPa, while for all variations of test specimens, the use of 40% eggshell powder and 60% fly ash produces the highest compressive strength which is 32.33 MPa. This increase in strength is due to magnesium, iron, and calcium carbonate as compounds found in eggshell powder and Portland cement.
Pengaruh Retak dan Pelapukan Tanah Terhadap Potensi Kelongsoran Saat Hujan Dengan Uji ERT, IP dan Pemodelan Numerik: The Effect of Cracks and Soil Weathering on Landslide Potential During Rain with ERT, IP and Numerical Modeling Tests
Kumala sari, Putu tantri;
Wardani, Mila Kusuma
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 2 (2024): Vol. 6 No. 2 (2024)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v6n2.p228-233
Landslides occurred in the hilly area of Tulakan-Pacitan, East Java. The landslide location is right under the supplies electricity tower to the Java and Bali. The landslide occurred during the rainy season that the intensity reached 1000 mm/month and the maximum was 300 mm/day. Geotechnical observations and geophysical observations, Electrical Resistivity Tomography (ERT) and Induced Polarization (IP) have been carried out. Geotechnical testing stated that the soil conditions in the hilly area around the landslide tended to be good. The results of the ERT and IP tests showed that there were layers weathering and cracks in the landslide area. The weathered and cracked soil conditions were not captured in geotechnical tests. This study was conducted to determine the causes of landslides, in hilly areas with predominantly good soil but experiencing weathering and cracks. Numerical modeling based on limit equilibrium (LEM) and finite element (FEM) was carried out by modeling the presence of soil weathering and cracks. The results of this study indicate that the presence of soil cracks and weathering can reduce slope stability, especially during heavy rain. The number of cracks and the seepage parameter in weathered soil can also affect the stability of a slope, causing landslides.
Tinjauan Operasional Kereta Api Barang Yang Melalui Wilayah Perawatan UPT Resor Jalan Rel IV.2 Rejosari
Abdurrohman, Haqiqi;
Abdurrachman, Edi;
Pribadi, Ocky Soelistyo
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 2 (2024): Vol. 6 No. 2 (2024)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v6n2.p161-170
Operasional KA angkutan barang dengan komoditi yang diangkut berupa pulp, semen, dan batubara dalam 6 tahun terakhir mendominasi lalu lintas perjalanan KA pada wilayah perawatan UPT Resor Jalan Rel IV.2 Rejosari di Kabupaten Lampung Selatan, dan hampir setiap tahunnya terjadi peningkatan frekuensi perjalanan KA. Adanya peningkatan frekuensi perjalanan KA berdampak kepada total tonase yang melintas pada wilayah perawatan UPT Resor Jalan Rel IV.2 Rejosari. Total tonase KA tertinggi yang melintas terjadi pada tahun 2023 sebesar 37.526.832 ton, nilai tersebut masih berada dalam range daya angkut lintas tahunan yang ditetapkan untuk jalan kelas I pada Peraturan Menteri Perhubungan Nomor 60 Tahun 2012. Dengan tentu total tonase akan mengalami perbesaran nilai apabila memasukkan faktor pengali dan mempertimbangkan lalu lintas KA penumpang meskipun jumlahnya tidak signifikan, sehingga range daya angkut lintas diatas 20 juta ton untuk kelas jalan I perlu dipertimbangkan kembali mengenai berapa nilai maksimalnya, sebab jika dalam hal ini tidak ada batasan nilai range maksimalnya, akan berpotensi menimbulkan konflik dengan batasan maksimal dari spesifikasi teknis material untuk suatu jalur kereta api.
The LIGHT TRAFFIC MODELING AT UNSIGNALED INTERVIEWS USING THE PTV.VISSIM AND PKJI 2023 APPLICATION (Simpang 3 Jl. Sungai Rupat, Bengkulu City): PEMODELAN TRAFFIC LIGHT PADA SIMPANG TAK BERSINYAL MENGGUNAKAN APLIKASI PTV.VISSIM DAN PKJI 2023 (Simpang 3 Jl. Sungai Rupat Kota Bengkulu )
pramudiya, chendi;
Elly Pujiastutie;
Edito Dwiantoro
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p1-7
The unsignalized intersection on Jl. Sungai Rupat is type 322 intersection that has 3 intersection arms, 2 lanes on minor roads and 2 lanes on roads. At this 3-way intersection, it is an inner-city road that connects roads to the city center, hospitals, offices, school, and worship so has a fairly high density and ultimately the density of traffic volume becomes high. When the morning peak hour occurs, it will cause congestion so that the police are often involved to regulate traffic. This study aims to create a traffic light modeling using PTV Vissim and also the PKJI 2023 method. Data collection for 7 days during peak hours to find the highest traffic volume so that the data can be analyzed using the PKJI 2024 method and simulated using PTV Vissim. The highest traffic volume, namely Tuesday at peak hours in the morning at 7:30 - 9:00 with a traffic volume (Q) of 3450 sec/hour capacity (C) 2844 sec/hour, queue opportunity of 60.08%-122.39% and a delay of 43.65 sec/sec with intersection service level (LOS) E. And the modeling results obtained Delay results at 15.43 sec/sec with a queue length of 11.50-44.79 m with an intersection service level index (LOS) B.
The Effect of Compressive Strength of Concrete with Styrofoam Waste Cement Coating on Acid Solution and Water Permeability: Pengaruh Kuat Tekan Beton Dengan Coating Cement Limbah Styrofoam Terhadap Larutan Asam Dan Permeabilitas Air
Sarjano, Belany Try Aji;
Aswadi, Lalu Samsul;
Yuwana, Dwi Sat Agus
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p8-16
This research analyze the effect of styrofoam cement coating as a protective layer on normal concrete in terms of physical quality and compressive strength when exposed to Natrium Sulfat acidic solution. Styrofoam-based cement coating is chosen due to water-resistant physical properties and its ability to reduce difficult-to-decompose waste. The method related to the effect of cement styrofoam coating as a liner with cylindrical concrete test objects measuring 15 cm in diameter and 30 cm in height and a quality of fc' 20 MPa, where its implementation is based on SNI 7656-2012. The cement coating used utilizes various mixture ratios of 0%, 40%, 50%, and 60% of the solvent weight in the form of Pertalite. The process of immersion in sodium sulfate acid solution, compressive strength testing, and permeability testing were conducted in the Laboratory, Universitas Tidar. The results indicate that the addition of styrofoam cement coating can reduce the corrosive impact of Natrium Sulfat acidic solution. The 60% styrofoam mixture variation showed the best results in three testing aspects: a post-curing compressive strength test value of 21.3621 MPa, a post-immersion in Natrium Sulfat acidic solution compressive strength test value of 20.7680 MPa, and a permeability test value of 7.03x10-9.
The Performance Assessment of Irrigation System on Tertiary Irrigation Network of Jabung Irrigation Area, East Lampung Regency: Performance Assessment of Irrigation System on Tertiary Irrigation Network of Jabung Irrigation Area, East Lampung Regency
Mahardika, Siti;
Dyah Indriana Kusumastuti;
Endro Prasetyo Wahono;
Nur Arifaini
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
Jabung Irrigation Area is one of the irrigation areas located in East Lampung Regency with an area of 7,288 hectares. Jabung Irrigation Area has a problem of uneven water distribution. This problem occurs in the downstream area due to damage to physical infrastructure, especially in tertiary irrigation canals, and sub-optimal operation and maintenance activities. Therefore, based on the Minister of Public Works and Housing Regulation No. 12/PRT/M/2015 concerning the Exploitation and Maintenance of Irrigation Networks, a study was conducted on determining the Irrigation System Performance Index (IKSI) of the tertiary network in the Jabung Irrigation Area. The purpose of this study is to assess the performance of the tertiary irrigation system of the Jabung Irrigation Area which is useful for formulating follow-up programs such as repair, rehabilitation, and maintenance of the irrigation network. The research method was carried out using a qualitative descriptive method and direct assessment in the field as well as interviews. The assessment covers 6 aspects, namely the condition of physical infrastructure, crop productivity, supporting facilities, personnel organization, documentation, and Farmers' Water Users Association (P3A). The results showed that the performance of the tertiary irrigation network in the Jabung Irrigation Area is in good condition (70.54%).
Labor Productivity Analysis Using Productivity Rating and Time Study Methods: Analisis Produktivitas Tenaga Kerja Menggunakan Metode Productivity Rating Dan Time Study
Kristiana, Retna;
Ridhwan Gilang Ramadhan
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p23-30
Ability of all individuals and well-organized companies to produce goods or services is a broad definition of productivity. Following the field observation procedure, data analysis was carried out using time study and Productivity Ranking techniques. Research methodology helps in systematic data collection and application of facts to solve problems. For three weeks, observations were made on the beam and floor slab formwork work using a daily field observation form that had been made previously. Ensuring that the worker's actions are in accordance with the observation by providing a checklist and recording the observation findings in the form. Calculating the results of the observation presentation. The beam and floor slab formwork work is a type of visible work. Labor efficiency level with a total average of three weeks of all work utilities, or LUR value, is known to be 66.30% based on the analysis results. Since labor is considered to have achieved effective or satisfactory time if it exceeds the LUR value or worker utility factor above 50%, the labor efficiency level is functioning successfully or satisfactorily. For a 40 m2 beam formwork work, productivity measurements such as scaffolding installation activities require a worker coefficient of 0.0182 m2/OH worker per day.
Design of Reinforced Concrete Structure for The Earthquake-Resistant 9-Story Green Hexa Hotel Using a Dual System in Pontianak: Perancangan Struktur Beton Bertulang Gedung Hotel Green Hexa 9 Lantai Tahan Gempa Dengan Menggunakan Sistem Ganda di Kota Pontianak
Rahmasari, Puspita;
Nikita Putri, Asha;
Rizaldi;
Supardi, Iwan
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p31-40
Pontianak City is undergoing substantial growth in the tourism sector, as evidenced by the increasing number of tourists annually, making the presence of hotels increasingly crucial. From 2011 to 2019, West Kalimantan itself experienced six earthquakes, making earthquake-resistant building planning a necessity as a mitigation against earthquake disasters. This research aims to obtain a safe and comfortable design for an earthquake-resistant hotel building in Pontianak based on SNI 1726: 2019. The Green Hexa Hotel consists of 9 floors with a total height of 36 m and an area of 1286 m2 using a reinforced concrete structure. The building is designed using SRPMM combined with shear walls. The loading refers to SNI 1727:2020. The structural analysis using ETABS and 2D working drawings using AutoCAD software. All structural components are designed using concrete with the fc' 30 MPa and fy 420 MPa rebar. The design results include a 150 mm solid slab floor and a 120 mm floor slab; 6 types of beams, BI.1 35cmx65cm, BA.1 30cmx50cm, BI.2 30cmx55cm, BA.2 24cmx45cm, elevator beam 24cmx45cm, landing beam 24cmx45cm; 2 types of columns, K.1 60cmx60cm, K.2 40cmx40cm, a type of 30 cm shear wall; 7 types of foundations, P.1 140cmx140cmx50cm, P.2 140cmx260cmx50cm, P.3 260cmx260cmx60cm.
Evaluation of Parking Characteristics and Parking Demand with PTV Vissim 8.0 at Rejowinangun Market, Magelang: Evaluasi Karakteristik dan Kebutuhan Parkir Menggunakan PTV Vissim 8.0 di Pasar Rejowinangun Magelang
Soebari, Hashifah Putri;
Woro Partini Maryunani;
Lalu Samsul Aswadi
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p41-46
Rejowinangun Market is traditional market in Magelang City. Volume of vehicles in the parking area is also expected to increase. Therefore, this study aims to evaluate the characteristics, layout arrangement, and parking needs in the Rejowinangun market to better understand the current situation in the parking area. Research was conducted using the cordon survey method and direct observation at 06.00-08.00 and 12.00-14.00 on three days. The results indicate that the highest occupation of the parking area occurred of 1,468 motorcycles and 40 cars parked during the observation period. The number of parked vehicles at 489 motorcycles and 23 cars. The parking turnover rate at 3.231 and 3.778 for motorcycles and cars. Importantly, the parking index that the current parking area is overloaded with cars (index value of 115%), which is not the case for motorcycles (index value of 46%). Parking model with PTV Vissim shows the highest occupancy on the second floor, with values of 54.63% and 52.35% for motorcycles and cars. The highest level of parking block space (0.04%) was found in the motorcycle parking area on the second floor. The validity further shows that the parking model is valid and therefore the results of this study are reliable.
Analysis Of The Effect Of The Use Of Coral Reefs As A Substitute For Fine Aggregates On The Compressive Strength Of Concrete: ANALISIS PENGARUH PENGGUNAAN TERUMBU KARANG SEBAGAI SUBTITUSI AGREGAT HALUS TERHADAP KUAT TEKAN BETON
Ramadhan, Muhammad Fathur;
Minaka, Utari Sriwijaya;
Febriyandi
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 7 No 1 (2025): Vol 7 No 1 (2025)
Publisher : Universitas Negeri Surabaya
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.26740/proteksi.v7n1.p47-52
Eco-friendly materials are in the spotlight of the world because they have a very influential impact on the development and advancement of technology today. Construction made of eco-friendly materials doesn’t damage nature, is lighter and use recycled materials. Coral reefs are a type of waste that can used to increase the compressive strength of concrete. This study analyzes the effect of using coral reef waste fragments as fine aggregate substitution of 70%, 75%, and 80%. The comparison was made against normal concrete without coral reef waste fragments. Compressive strength results were obtained in normal concrete of 25.93 MPa at the age of 28 days, while in concrete variations of coral reef waste fragments as fine aggregate substitution at the age of 28 days with variation of 70% of 28.18 MPa, variation of 75% of 26.48 MPa, and variation of 80% of 26.65 MPa. These results show that the use of coral reef waste fragments as fine aggregate substitution of 70% is the optimal result, and the use of coral reef waste fragments more than that can reduce the compressive strength of concrete, due to the excessive chemical compounds contained in coral reef waste, it can reduce the resistance to concrete.