Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer
ISSN : 23014652     EISSN : 2503068X     DOI : -
Core Subject : Education,
SETRUM : Sistem Kendali Tenaga Elektronika Telekomunikasi Komputer merupakan jurnal yang diterbitkan oleh Jurusan Teknik Elektro, Fakultas Teknik, Universitas Sultan Ageng Tirtayasa (UNTIRTA) sejak 2012 menggunakan sistem Open Journal System (OJS).
Arjuna Subject : -
Articles 294 Documents
Analisis Kinerja Jaringan Internet Banten (JIB) Menggunakan Metode QoS dan RMA Husna, Anisa Nurul; Lufianawati, Dina Estining Tyas
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 1 (2024): Edisi Juni 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/setrum.v13i1.22385

Abstract

Kemajuan teknologi informasi pada saat ini mulai berkembang seiring dengan kebutuhan yang menginginkan kemudahan, kecepatan, dan keakuratan dalam memperoleh informasi. PT. Jaringan Internet Banten (JIB) merupakan penyedia layanan akses internet di Cikande, Serang yang berkomitmen ingin memberikan kualitas yang bagus dalam layanan internet langsung dan internet solusi. JIB ini merupakan penyedia layanan internet yang masih baru, sehingga diperlukan analisis Quality of Service (QoS) berdasarkan parameter troughput, jitter, packet loss, dan delay dengan menggunakan aplikasi Wireshark dan memonitoring kinerja perangkat yang terhubung ke jaringan berdasarkan metode Realibility, Maintainability, Availability (RMA) dengan menggunakan aplikasi Paessler Router Traffic Grapher (PRTG). Penelitian ini dilakukan pada setiap weekend selama 3 minggu. Hasil dari pengukuran QoS ini bahwa nilai rata-rata troughput pada JIB sebesar 33.354 kbit/s (sangat bagus), variasi delay hanya bervariasi disekitar 13 msec (milisecond) sampai dengan 18 msec (milisecond) sehingga dikatakan cukup stabil, tidak adanya packet loss pada JIB sehingga menunjukkan bahwa kualitas jaringan baik dan stabil dalam pengiriman paket data, rata-rata jitter selama rentang waktu yang diberikan berkisar antara 15-18 ms. Hasil pengukuran RMA menunjukkan bahwa pada minggu pertama rata-rata kecepatan lalu lintas sebesar 1.154.776 kbit/s, pada minggu kedua rata-rata kecepatan lalu lintas sebesar 1.116.097 kbit/s, dan pada minggu ketiga rata-rata kecepatan lalu lintas sebesar 1.594.245 kbit/s.
Review Pemodelan Rangkaian Listrik pada Fenomena Partial Discharge Nugraha, Adi; Felycia, Felycia
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 1 (2024): Edisi Juni 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/setrum.v13i1.25690

Abstract

Partial dischrage merupakan suatu peristiwa tembusnya tegangan yang diakibatkan ketidakmampuan suatu insulasi menahan tegangan. Partial discharge dapat terjadi di bagian dalam, permukaan insulasi bahkan dapat menciptakan busur api. Pemodelan PD dikemukakan oleh para ahli dan dianalisis dengan model secara matematis. Percobaan adanya PD dilakukan dalam 3 tipikal yauitu internal discharge, surface discharge dan tip discharge. Diperoleh hasil intensitas PD yang berbeda beda pada masing masing tipikal tersebut
Desain dan Impelementasi Multilevel Inverter Tiga Tingkat Untuk Mereduksi Harmonisa Bagus Afif Nasrudin; Sutedjo Sutedjo; Endro Wahjono
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 12, No 2 (2023): Edisi Desember 2023
Publisher : Fakultas Teknik Elektro - Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/setrum.v12i2.16638

Abstract

Suplai kualitas daya listrik yang baik merupakan elemen yang sangat dibutuhkan bagi peralatan listrik. Umumnya inverter konvensional menghasilkan THD tegangan dan arus yang cukup tinggi yang mana berpengaruh pada meningkatnya rugi-rugi akibat harmonisa sehingga efisiensi yang dihasilkan semakin turun. Oleh karena itu diusulkan sebuah sistem terdiri dari baterai sebagai sumber dc yang digunakan untuk mensuplai multilevel inverter yang merupakan salah satu jenis inverter yang memiliki bentuk gelombang tegangan maupun arus yang bertingkat. Multilevel inverter dimodulasi dengan metode Alternate Phase Opposition Disposition (APOD-PWM) yang mana teknik modulasi ini membutuhkan masing-masing dari empat bentuk sinyal pembawa untuk bentuk gelombang keluaran inverter tiga tingkat dengan masing-masing sinyal pembawa digeser fasanya sebesar 120˚ dari sinyal yang berdekatan secara bergantian. Dari data hasil pengujian, multilevel inverter 3 tingkat dapat mengubah 36 VDC  menjadi 15.6 Vrms AC yang kemudian dinaikkan tegangannya oleh trafo step-up menjadi 215 Vrms AC dengan persentase error 2.2%. Keluaran dari multilevel inverter tiga tingkat setelah melalui filter dengan beban lampu pijar 400 Watt menghasilkan THD tegangan sebesar 7,4% dan THD arus sebesar 7.6%.
Perbandingan Ketebalan Insulasi Jenis Kertas Laminasi Ditinjau dari Tegangan Tembus Transformator pada Dua Kondisi Samsurizal, Samsurizal; Afrianda, Rio; Makkulau, Andi
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 1 (2024): Edisi Juni 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/setrum.v13i1.22789

Abstract

An insulation layer is used to cover the transformer winding in a transformer. Commonly used insulations in transformers include oil insulation and paper insulation. Paper insulation is soft and flexible, adapting to any desired shape. The crucial factors to consider in insulation are strength and durability. This research was conducted through testing with two conditions: varying the thickness of the paper and the condition of the paper when dried and immersed in insulation oil. The test results show that insulation paper with a thickness of 1.04 mm in a dry state has an average breakdown voltage of 6.7 kV. When immersed in oil, the same thickness has a breakdown voltage of 23.82 kV, indicating that insulation paper with the immersion method has a better breakdown voltage than dry insulation paper.
Pemanfaatan Teknologi Dengan Esensial Sensor GSM dan GPS Guna Meminimalisir Angka Kecelakaan Di Indonesia Samsurizal, Samsurizal; Qori, Syrojul; Ardian, Irfan; Mangende, Indrani; Ananda, Shafia
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.27603

Abstract

Kecelakaan lalu lintas merupakan masalah serius di Indonesia yang mempengaruhi banyak orang setiap tahunnya. Tingkat kecelakaan yang tinggi disebabkan oleh berbagai faktor, termasuk kurangnya kepatuhan terhadap aturan lalu lintas dan infrastruktur jalan yang tidak memadai. Kampanye kesadaran keselamatan lalu lintas telah dilakukan oleh pemerintah, tetapi kesadaran akan pentingnya keselamatan belum merata di semua lapisan masyarakat. Faktor manusia menjadi penyebab utama kecelakaan, diikuti oleh faktor kendaraan dan faktor prasarana. Salah satu masalah utama adalah pengendara bermotor yang enggan menggunakan helm, meskipun penggunaan helm dapat melindungi dari cedera serius atau kematian. Sebagai solusi inovatif, Metode yang digunakan untuk mengatasi masalah kecelakaan di Indonesia dengan membuat prototype  yang terintergrasi dengan sensor Gsm dan GPS Dalam Upaya percepatan pertolongan pada korban kecelakaan.Hasil yang di dapat Bahwa sensor GSM dan GPS mampu memberikan respon cepat pada situasi darurat hal ini terbukti pada percaan yang dilakukan dimana sensor ini mampu bekerja pada magnitudo 70 M
Ensuring Relay Protection Device Reliability by Setting Value and Time Delay Verification (10Kv Motor Differential Current Protection) Kamal, Ahmad Ilham; Dona, Nur Rahma
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.29325

Abstract

Protection relay devices are very important in the electrical system where they act as voltage breakers when there is a disturbance in the electrical system so that electrical equipment and those connected to it are not damaged. Based on the IEC 60255 standard, protection relay devices are required to be reliable, fast, and selective so that the electrical system is protected from disturbances and works properly without miss-operation. The standard tolerance for the verification value deviation is not more than 5% of the setting value, this refers to the IEC 60255 standard. This journal explains the testing of setting valuesand time delays on protection relay devices that focus on differential current protection. The results of this test can be concluded whether the protection relay is still suitable for use or not with a standard tolerance deviation of ≤5%.
Dampak Penyambungan PLTM Bayang Nyalo ke Sistem 20 kV PLN ULP Painan, Sumatera Barat Nasir, Muhammad; Kamil, Insannul; Adrianti, Adrianti; Syafdini, Riki
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.28185

Abstract

The electric power distribution system will change very quickly along with the growth of the load which tends to increase every year. The increase of electricity demand must be anticipated with the addition of the number of generating plants that will integrate to the system in order to carry out continuous and optimal system operations. Before adding new generators to the system, a feasibility study will be conducted to provide optimal results using simulation of power flow studies. The connection of the Bayang Nyalo Hydro Power (BNHP) to the medium voltage 20 kV electricity system of the PLN with several operating scenarios provide significant results. The most optimal results have been obtained with scenario 2-2, which the operating voltage changed from 0.80 pu to 0.95 pu and power losses decreased from 2.04 MW to 1.67 MW. This provides a recommendation that the operating scheme of scenario 2-2 should be applied when the Bayang Nyalo Power Plant connects the PLN 20 kV system because this scenario does not require additional new investment from PLN.
Sistem Otentikasi Biometrik Multimodal Berbasis Fitur Tekstur Garis Telapak dan Pembuluh Darah Punggung Tangan dengan Metode BPNN Yudono, Muchtar Ali Setyo; Nugraha, Adi; Franata, Nauval; Ramadhani, Ahmad; Erlindriyani, Ratu Verlaili; Zulfiqar, Danial; M.Syam, Fajar; Futri, Dila Aura; Fauzan, Akmal Nuur
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.29589

Abstract

Kebutuhan akan sistem otentikasi yang aman terus meningkat seiring perkembangan teknologi digital. Sistem autentikasi biometrik berbasis ciri khas manusia, seperti pengenalan wajah dan sidik jari, menawarkan solusi namun masih rentan terhadap manipulasi. Penelitian ini mengembangkan sistem autentikasi biometrik multimodal dengan menggabungkan fitur garis telapak tangan dan pola pembuluh darah punggung tangan, memanfaatkan Backpropagation Neural Network (BPNN) untuk klasifikasi dan Tapis Gabor untuk ekstraksi ciri. Sistem ini dirancang untuk meningkatkan akurasi, sensitivitas, dan spesifisitas autentikasi. Pada data pelatihan, sistem mencapai akurasi sebesar 98,1%, sensitivitas 100% pada kelas tertentu, dan spesifisitas optimal. Sementara pada data pengujian, akurasi tercatat sebesar 91%, dengan sensitivitas tertinggi mencapai 95% dan spesifisitas tetap tinggi pada kelas tertentu. Hasil ini menunjukkan bahwa sistem autentikasi multimodal berbasis BPNN dan Tapis Gabor dapat diandalkan dalam aplikasi keamanan digital, karena mampu memanfaatkan dua sumber biometrik berbeda untuk meningkatkan keakuratan dan daya tahan terhadap teknik pemalsuan.
Feasibility Power Control on Cognitive Radio Network with Fixed Power of Primary User Amalia, Norma; Hikmaturokhman, Alfin
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.29004

Abstract

Frequency spectrum is a limited resource that is strictly determined by static spectrum policy. As every part of the spectrum is already allocated to several certain services, only a portion can be obtained. On the other hand, as the user’s demand for reliable communication systems is increasing rapidly, a new paradigm of communication systems is needed. It is compulsory for existing spectrum can handle the increasing number of users, as cognitive radio technology could well address this issue. One crucial key of this technology is its power control. In this paper, the power control based on a feasible solution is studied. The PU has fixed power, the SU power is controlled using the power control method. The non-negative power vector is limited by the initial power . The output parameters of this simulation are the FSPC effect to the performance of SU and PU, the SU’s  impact on the feasible solution, and the feasible solution probability. In the  constraint, the PU SIR  rises from 14 dB to 22 dB upon implementing a FSPC. The PU SIR is contrary to the SIR of SU. When the target of the SU’s SIR is increased, the SIR value of the PU is decreased. As well as when the  value of the SU increases, the greater the SIR of the SU, the lower the SIR of the PU. If the power control is feasible, both PU and SU can simultaneously meet the target SIR. Considering the primary user's (PU) power remains fixed, the PU, as the main user, can determine its own power without being influenced by the SU power. 
Analisis Sistem Proteksi Motor Induksi 6KV Pada Circulating Water Pump (CWP) Menggunakan Relay Overcurrent dan Short Circuit Unit 1-4 PT. PLN Indonesia Power UBP Suralaya Otong, Muhamad; Albantani, Maulana Ilham
Setrum : Sistem Kendali-Tenaga-elektronika-telekomunikasi-komputer Vol 13, No 2 (2024): Edisi Desember 2024
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62870/setrum.v13i2.29800

Abstract

Pembangkit Listrik Tenaga Uap (PLTU) dilengkapi dengan Circulating Water Pump (CWP) yang berguna untuk mensirkulasikan air pendingin (menggunakan air laut) pada kondensor. Circulating Water Pump (CWP) memiliki peran penting karena jika CWP mengalami penurunan performa saat memompa air pendingin maka uap yang dikondensasikan juga akan berkurang sehingga perlu penambahan biaya produksi untuk siklus menjadi normal kembali. Circulating Water Pump (CWP) digerakan oleh motor induksi 6 kV 3 fasa. Motor induksi dalam CWP bertanggung jawab untuk memutar baling-baling (pompa) yang terdapat di dalam CWP sehingga air pendingin (air laut) mengalir. Proteksi sistem tenaga listrik, khususnya pada proteksi motor induksi tiga fasa di PLTU Suralaya menggunakan dua relay yang dapat mendeteksi gangguan arus lebih (overcurrent) dan hubung singkat (short circuit). Relay yang digunakan untuk proteksi motor pada PLTU Suralaya unit 1-4 menggunakan Relay IMM 7000. Relay ini dapat memutus aliran listrik ketika mendeteksi gangguan yang melebihi ambang batas pada motor.