cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota bandar lampung,
Lampung
INDONESIA
Jurnal Rekayasa Sipil dan Desain
Published by Universitas Lampung
ISSN : 23030011     EISSN : 27150690     DOI : -
Core Subject : Engineering,
Arjuna Subject : -
Articles 840 Documents
ANALISIS UDARA AMBIEN POLUTAN CO KENDARAAN BERMOTOR TERHADAP TUTUPAN LAHAN DI LINGKUNGAN UNIVERSITAS LAMPUNG Hamzah, Budi; Sulistiyorini, Rahayu; Putri Ofrial, Siti Anugrah; Herianto, Dwi
Jurnal Rekayasa Sipil dan Desain Vol 11, No 1 (2023): Edisi Maret 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study aims to see the effect of the number of vehicles on the amount of Carbon Monoxide (CO) emissions in the University of Lampung environment after there is land cover and the amount of ambient air concentration of Carbon Monoxide (CO) Pollutants in the University of Lampung environment after there is land cover.  The location of this study is at the University of Lampung, the stages of data collection in this study are carried out in two stages, namely primary data collection and secondary data collection, then analyzed through complications and tabulation activities as well as analysis of air quality levels at the University of Lampung after land cover. The results of research and data analysis show that overall the air quality of Carbon Monoxide (CO) in the University of Lampung environment after land cover is in the good category because it has a range of air pollution between 1 - 50 according to air quality standards set by the government through regulations. Minister of Environment and Number P.14/MENLHK/SETJEN/KUM.1/7/2020 concerning Air Pollutant Standard Index.CO concentration is still at the threshold value required by Government Regulation Number 41 of 1999 concerning ambient air quality standards even though most of the land in the University of Lampung is land cover. Key words : Ambient Air, Carbon Monoxide (CO), Land Cover.
Pengaruh Abu Ketel sebagai Bahan Penambah Campuran Beton Normal terhadap Kuat Tekan Hidayatullah, Hadi; Irianti, Laksmi; Helmi, Masdar; Widyawati, Ratna
Jurnal Rekayasa Sipil dan Desain Vol 12, No 1 (2024): Edisi Maret 2024
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Much of the kettle ash waste found in palm oil mills is wasted and can pollute the environment. Therefore, efforts need to be made to handle this waste. One of them is its use as an additional ingredient in concrete mixtures. . This research aims to analyze the effect of kettle ash on the rate of increase in compressive strength through laboratory testing with variations in kettle ash used, namely 0%, 5%, 10%, 15% and 20% of the cement weight. The test specimens have dimensions of 15 cm x 15 cm x 15 cm with testing times at 3 days, 7 days, 14 days, 28 days and 56 days. Based on analysis of research data, it was found that the majority experienced an increase in the compressive strength of concrete without additional materials. Increases occurred at 3 days, 7 days, 14 days and 28 days. The percentage increase in compressive strength for the majority decreased at the age of 3 days, 7 days, 14 days. Meanwhile, at the age of 56 days the majority experienced an increase in the percentage of compressive strength which was caused by a quite significant increase in compressive strength. The highest compressive strength at 56 days was produced by test object code BAK 1 of 38.59 MPa
Penentuan Letak Pengukuran Reflected Temperature dengan Menggunakan Termokopel pada Pengujian Termografi Aktif Terhadap Beton Bertulang Ikromi, Muhammad Fauzan; kartorono, suyadi; Helmi, Masdar; Isneini, Mohd
Jurnal Rekayasa Sipil dan Desain Vol 11, No 4 (2023): Edisi Desember 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstrakPengujian termografi aktif merupakan salah satu pengujian non-destruktif yang menggunakan kamera inframerah sebagai perekam dan menghasilkan termogram. Termogram merupakan interpretasi energi panas yang diterima oleh sensor termal kamera inframerah yang masih mengandung noise. Reflected temperature (Trefl) merupakan salah satu noise yang muncul dari pengujian termografi aktif dan akan digunakan sebagai nilai koreksi. penelitian ini menyajikan suatu metode untuk mencari posisi pemasangan termokopel di sekitar sumber panas, sehingga nilai suhu pada posisi tersebut digunakan sebagai nilai Trefl untuk memperbaiki noise pada termogram. Sampel beton berbentuk kubus dengan ukuran 10x10x15 cm diukur suhu permukaannya menggunakan termokopel dan kamera inframerah sejauh 1 meter. Hasil penelitian menunjukkan selisih hasil pengukuran menggunakan termokopel dan termografi sebesar 2,349 ℃, lalu rata-rata nilai Trefl yang didapatkan dari pengujian termografi aktif sebesar 51,649℃ terletak 13 cm dari atas papan grid sebesar dan 5 cm di depan lampu halogen. Suhu permukaan beton sebelum dikoreksi memiliki nilai yang lebih tinggi karena memiliki noise, namun setelah dilakukan analisis perhitungan suhu mengalami penurunan dan mendekati suhu hasil pengukuran termokopel dengan analisis kesalahan (ΔTerr) rata-rata didapatkan 1,448%. Berdasarkan hasil analisis terebut menunjukkan akurasi data kesalahan tergolong bagus karena nilai rata-rata analisis kesalahan (ΔTerr) <5%.Kata kunci : Reflected Temperature, Termografi aktif, Pengujian Non-destruktif
Pengaruh Pasir Laut Sebagai Campuran dan Air Laut Untuk Curing Terhadap Kuat Tekan Beton Zikrillah, Daffa; Helmi, Masdar; Isneini, Mohd; Alami, Fikri
Jurnal Rekayasa Sipil dan Desain Vol 11, No 3 (2023): Edisi September 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstrakIndonesia merupakan negara maritim Namun dikarenakan belum meratanya akses masyarakat terhadap air bersih dan langkanya pasir yang sesuai standar, membuat banyak pembangunan yang dilakukan di pesisir pantai dilakukan dengan material yang tidak sesuai dengan standar dan mengakibatkan berubahnya kekuatan beton. Dalam penelitian ini dibahas kuat tekan beton yang menggunakan material pasir laut dan curing menggunakan air laut dimana didapatkan hasil bahwa pasir laut dan curing dengan air laut memiliki dampak negatif terhadap kuat tekan beton dibandingkan menggunakan pasir sungai dan curing dengan air tawar menggunakan sample beton kubus 15x15x15 cm sejumlah 48 sample dengan 2 variasi campuran dan 2 metode curing diuji di umur 7, 14, 28, dan 56 hari. Hasil kuat tekan beton yang menggunakan material pasir laut dan curing menggunakan air laut dimana didapat hasil BPLCT memiliki kuat tekan yang lebih rendah dibanding BNCT senilai 336,1 kg/cm2 dan BNCT senilai 355,9 kg/cm2 pada umur 28 hari dan curing dengan air laut memiliki dampak negatif terhadap kuat tekan beton dibandingkan menggunakan pasir sungai dan curing dengan air tawar dengan nilai BNCL 331,2 kg/cm2 dibanding BNCT senilai 355,9 kg/cm2 pada umur 28 hari. Dapat disimpulkan bahwa penggunaan pasir laut sebagai pencampur beton dan air laut sebagai curing beton menghasilkan pengaruh buruk terhadap kuat tekan beton.Kata kunci : pasir laut, air laut, dan kuat tekan
Karakteristik Arus Lalu Lintas Pada Jalan 2/2 Tidak Terbagi Sari, Yulianti Dewi Manda; Putra, Sasana; Sulistyorini, Rahayu; Herianto, Dwi
Jurnal Rekayasa Sipil dan Desain Vol 11, No 1 (2023): Edisi Maret 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The conditions of volume, speed, and density are influenced by the interaction of the driver and the vehicle with the road and the environment. One of the way to understand traffic behavior is by describing it in mathematical and graphical form.Through analysis of the relationship between volume, speed, and density can be known information about the current traffic flow conditions. The Greenshield model is used to represent the mathematical relationship between volume, speed, and density. The purpose of the study to analyze the characteristic relationship on 2/2 roads with an undivided type. Based on the results of calculating the mean speed, the service level of this road is type E. The mean speed in the morning is 28.78 km/hour towards Teluk and 25.44 km/hour towards Tanjung Karang. It concluded that the mean speeds of vehicles at this research location are not according to the Regulation of the Minister of the Republic of Indonesia Number 96 of 2015, where for secondary arterial roads with a service level of at least C, namely 60 km/hour.Based on the analysis of the relationship between traffic characteristics using the Greenshield model obtained (r2) = 0,276.
Analisis Variasi Layout Shearwall Dengan SNI 1726-2019 Terhadap Perilaku Bangunan Bertingkat (Studi Kasus: Gedung Pelayanan Publik Satu Atap Bandar Lampung) Setiawan, Andi; Isneini, Mohd.; Noorhidana, Vera Agustriana; Husni, Hasti Riakara
Jurnal Rekayasa Sipil dan Desain Vol 11, No 2 (2023): Edisi Juni 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Earthquake resistant buildings are not designed only by strengthening the resistance of the structure, but are also designed to reduce earthquake forces. One of the structural reinforcement elements that can reduce earthquake forces is shearwall. The variation of shearwall layout will have a different effect on the performance level of the structure. This study aims to determine the performance level of the structure with a variety of shearwall layouts in a building structure model using the pushover analysis method. Determining the level of structural performance using pushover analysis is carried out using the help of structural analysis programs based on SNI 1726-2019, SNI 1727-2020, SNI 2847-2019 and ATC-40. From the research results it was found that the structural performance level according to ATC-40 (1996), for model 1 and model 6 were included in the damage control category, while for model 2, model 3, model 4 and model 5 were included in the immediate occupancy category. Placement of shearwall which has the optimum value according to ATC-40 for the X direction occurs in model 2 with the shearwall installed in an L shape which is placed near the center of mass of the building. Whereas in the Y direction it occurs in model 3 with the shearwall installed in an L shape which is placed away from the center of mass of the building. Key words : shearwall, model, structure performance level, pushover analysis.
Pemetaan Ekowisata Terumbu Karang Berbasis Geographic Information System (GIS) di Pulau Pahawang Madany, Orista Ammar; Herison, Ahmad; Romdania, Yuda; Ashruri, A
Jurnal Rekayasa Sipil dan Desain Vol 11, No 2 (2023): Edisi Juni 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

AbstractCoral reef ecosystems are threatened with extinction. Along with the development of technology, the distribution of coral reefs can be reviewed only by looking at an information map. The purpose of this research is to map coral reef ecotourism on Pahawang Island. So that it is expected to provide information to the community and also island developers related to the condition of the coral reef ecosystem on Pahawang Island. The method used in map processing is sentinel 2A image data processing with the guided classification method in ArcGIS software, while the analysis method is descriptive, which describes the results of the coral reef cover map. The results of the analysis and discussion found that Geographic Information System (GIS) based remote sensing with processed sentinel 2A imagery is very helpful in the process of finding information on the distribution of coral reefs on Pahawang Island. Data processing in ArcGIS software using guided classification methods can be used in order to produce coral cover maps. The results of the coral reef distribution map have an area of 128.64 Ha. The conclusion is that Geographic Information System (GIS) based remote sensing with ArcGIS software can be used to produce coral cover maps. On Pahawang Island, the coral reef cover area of 128.64 Ha was obtained.
Evaluasi Kekuatan Struktur Gedung Bertingkat Terhadap Pengaruh Beban Gempa Menggunakan Analisis Dinamik Respon Spektrum (Studi kasus: Gedung MAN Insan Cendikia, Serpong) Restiawan, Arie Dwie; Bayzoni, Bayzoni; Husni, Hasti Riakara; Isneini, Mohd
Jurnal Rekayasa Sipil dan Desain Vol 11, No 3 (2023): Edisi September 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Indonesia is a region that is at risk of earthquakes. The impact of an earthquake is bad for the building structure, not only causing damage to the building, but also can cause the building to collapse. Therefore, to reduce the adverse effects obtained from earthquakes, it is necessary to design and evaluate the strength of building structures with resistance to earthquake loads. The method used in this study is dynamic response spectrum analysis to obtain the magnitude of the earthquake load. Evaluation of the strength of the building structure is carried out using structural analysis software to make it easier to do the analysis. This study aims to determine the ratio of the required strength in conditions without earthquake loads and conditions due to earthquake loads to the designed strength of the structure. Based on the results of this study, it can be concluded that the required strength obtained in conditions without an earthquake load reaches 8.33% to 90.62% of the designed strength, whereas in conditions due to strong earthquake loads the required strength obtained reaches 12.57% to 153.31% of the designed strength.Keywords: earthquakes, structural strength, dynamic analysis, response spectrum.
ANALISIS KOMBINASI CAMPURAN 3D DRAMIX DAN KAWAT BENDRAT PADA SELF COMPACTING CONCRETE (SCC) Zahra, Ainaya Maudia; Isneini, Mohd; Irianti, Laksmi; Widyawati, Ratna
Jurnal Rekayasa Sipil dan Desain Vol 11, No 3 (2023): Edisi September 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

SCC is fresh concrete that is able to flow through the reinforcement and fill the entire space in the mold without requiring manual compaction or mechanical vibration. SCC has a shortage of weak tensile strength values as in other concrete. So an innovation was made, namely the addition of fiber to the concrete. In this study, using a combination of bendrat wire and 3D Dramix with a length of 6 cm and a diameter of 0.8 mm, the volume fraction of the mixture amounted to 1% and 1.5% with a total of 8 combinations.  The compressive strength test object was a cylinder with a diameter of 150 mm and a height of 300 mm totaling 24 pieces and the flexural tensile strength test was a beam with a length of 400 mm, a width of 100 mm, and a height of 100 mm totaling 24 pieces. Tests were conducted at the age of 28 days. From the test results, the highest compressive strength occurred in BSV, namely a combination of 1.25% bendrat wire and 0.25% 3D Dramix with an increase in compressive strength of 15.04% of normal concrete. In the flexural tensile strength test, the maximum increase was obtained in BSV, namely the combination of 1.25% bendrat wire and 0.25% 3D Dramix with a percentage increase of 1206.5% from normal concrete.  This shows that the addition of 3D Dramix and bendrat wire increases the compressive strength and flexural strength of SCC. However, the more fiber in SCC causes the workability of the concrete to decrease and the pores in the concrete to increase.
Pemodelan Gedung Perawatan Neurologi RSUD Dr. H. Abdul Moeloek Provinsi Lampung Menggunakan Building Information Modeling (BIM) Khasanah, Felin; Husni, Hasti Riakara; Bayzoni, Bayzoni; Siregar, Amril Ma'ruf
Jurnal Rekayasa Sipil dan Desain Vol 11, No 1 (2023): Edisi Maret 2023
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Building Information Modeling (BIM) merupakan salah satu teknologi yang mempresentasikan digital dari karakteristik fisik dan fungsional dari suatu bangunan yang memuat informasi mengenai bangunan tersebut. Salah satu software yang mendukung konsep Building Information Modeling ialah software Autodesk Revit. Tujuan dari penelitian ini ialah memodelkan Gedung Perawatan Neurologi RSUD Dr. H. Abdul Moeloek Provinsi Lampung dengan menerapkankonsep BIM serta mendapatkan output volume pada pekerjaan cat dinding, pintu, dan jendela untuk setiap ruangan tiap lantai sebagai referensi pengambilan keputusan pada pemeliharaan dan perawatan. Pada penelitian ini menggunakan data as built drawing dan juga tinjauan lapangan. Pemodelan diawali dengan mengatur satuan, membuat grid dan level, membuat family struktur serta memodelkannya, membuat family arsitektur serta memodelkannya, membuat identity data, melakukan clash check, selanjutnya mengeluarkan hasil volume sesuai tujuan penelitian. Dari penelitian ini dapat disimpulkan bahwa memodelkan Gedung Perawatan Neurologi RSUD Dr. H. Abdul Moeloek Provinsi Lampung menggunakan konsep Building Information Modeling (BIM) lebih efektif karena output volume yang didapatkan tidak hanya secara menyeluruh tetapi dapatdikhususkan pada lantai maupun ruangan tertentu.Kata kunci : Building Information Modeling (BIM), Autodesk Revit, Pemeliharaan dan Perawatan

Filter by Year

2013 2024


Filter By Issues
All Issue Vol 12, No 1 (2024): Edisi Maret 2024 Vol. 12 No. 1 (2024): Edisi Maret 2024 Vol 11, No 4 (2023): Edisi Desember 2023 Vol. 11 No. 4 (2023): Edisi Desember 2023 Vol. 11 No. 3 (2023): Edisi September 2023 Vol 11, No 3 (2023): Edisi September 2023 Vol. 11 No. 2 (2023): Edisi Juni 2023 Vol 11, No 2 (2023): Edisi Juni 2023 Vol. 11 No. 1 (2023): Edisi Maret 2023 Vol 11, No 1 (2023): Edisi Maret 2023 Vol. 10 No. 4 (2022): Edisi Desember 2022 Vol. 10 No. 3 (2022): Edisi September 2022 Vol 10, No 2 (2022): Edisi Juni 2022 Vol. 10 No. 2 (2022): Edisi Juni 2022 Vol 10, No 1 (2022): Edisi Maret 2022 Vol. 10 No. 1 (2022): Edisi Maret 2022 Vol 9, No 4 (2021): Edisi Desember 2021 Vol. 9 No. 4 (2021): Edisi Desember 2021 Vol. 9 No. 3 (2021): Edisi September 2021 Vol 9, No 3 (2021): Edisi September 2021 Vol. 9 No. 2 (2021): Edisi Juni 2021 Vol 9, No 2 (2021): Edisi Juni 2021 Vol. 9 No. 1 (2021): Edisi Maret 2021 Vol 9, No 1 (2021): Edisi Maret 2021 Vol. 8 No. 4 (2020): Edisi Desember 2020 Vol 8, No 4 (2020): Edisi Desember 2020 Vol 8, No 3 (2020): Edisi September 2020 Vol. 8 No. 3 (2020): Edisi September 2020 Vol. 8 No. 2 (2020): Edisi Juni 2020 Vol 8, No 2 (2020): Edisi Juni 2020 Vol 8, No 1 (2020): Edisi Maret 2020 Vol. 8 No. 1 (2020): Edisi Maret 2020 Vol 7, No 4 (2019): Edisi Desember 2019 Vol. 7 No. 4 (2019): Edisi Desember 2019 Vol 7, No 3 (2019): Edisi September 2019 Vol 7, No 2 (2019): Edisi Juni 2019 Vol 7, No 1 (2019): Edisi Maret 2019 Vol 6, No 4 (2018): Edisi Desember 2018 Vol 6, No 3 (2018): Edisi September 2018 Vol 6, No 2 (2018): Edisi Juni 2018 Vol 6, No 2 (2018): Edisi Juni 2018 Vol 6, No 1 (2018): Edisi Maret 2018 Vol 6, No 1 (2018): Edisi Maret 2018 Vol 5, No 4 (2017): Edisi Desember 2017 Vol 5, No 3 (2017): Edisi September 2017 Vol 5, No 3 (2017): Edisi September 2017 Vol 5, No 2 (2017): Edisi Juni 2017 Vol 5, No 1 (2017): Edisi Maret 2017 Vol 5, No 1 (2017): Edisi Maret 2017 Vol 4, No 4 (2016): Edisi Desember 2016 Vol 4, No 3 (2016): Edisi September 2016 Vol 4, No 2 (2016): Edisi Juni 2016 Vol 4, No 2 (2016): Edisi Juni 2016 Vol 4, No 1 (2016): Edisi Maret 2016 Vol 3, No 3 (2015): Edisi September 2015 Vol 3, No 2 (2015): Edisi Juni 2015 Vol 3, No 1 (2015): Edisi Maret 2015 Vol 3, No 1 (2015): Edisi Maret 2015 Vol 1, No 1 (2013): Edisi Maret 2013 More Issue