Claim Missing Document
Check
Articles

Found 20 Documents
Search

Model Desain Healing Garden pada Ruang Publik dan Penataannya pada Halaman Rumah Tinggal bagi Peningkatan Kualitas Hidup di Perumahan Bumi Telukjambe, Karawang: Healing Garden Design Model in Public Spaces and Its Arrangements on the Household Page for Increasing the Quality of Life in Bumi Telukjambe Housing, Karawang Ina Krisantia; Qurrotu Aini Besila; Silia Yuslim; Riana Ayu Kusumadewi; Nur Intan Mangunsong; Olivia Seanders; Reza Fauzi
PengabdianMu: Jurnal Ilmiah Pengabdian kepada Masyarakat Vol. 8 No. 1 (2023): PengabdianMu: Jurnal Ilmiah Pengabdian kepada Masyarakat
Publisher : Institute for Research and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33084/pengabdianmu.v8i1.3019

Abstract

Bumi Telukjambe Housing, Karawang is a Perumnas (National Housing) area dominated by 21/60 house types. Houses with a limited area and the COVID19 pandemic create boredom and stress for residents because almost all of the resident's time is spent working at home. To minimize the feeling of boredom and stress of residents, efforts are needed to overcome them. Many studies reveal that one way to improve mental health and quality of life is to connect with nature. Healing garden is one way to make it happen. Community Service (Program Pengabdian kepada Masyarakat, PkM) of Department Landscape Architecture will conduct counseling on healing gardens, training on healing gardens on residential yards, and create a design model Healing Garden in public spaces to be used jointly by residents. The benefits felt by residents from PkM activities can be seen from questionnaires distributed to PkM participants, namely representatives of the Family Welfare Guidance Programme (Pembinaan Kesejahteraan Keluarga, PKK) women and RW/RT representative (RW 19’s Chief and RT 04’s Chief). The results of this PkM show that from all the statements answered by the participants, 100% of the participants felt that all the PkM activities they carried out were beneficial.
Analysis of the Load Carrying Capacity of BOD and COD Pollutants in The Krukut River Ody Nata Nugraha; Diana Hendrawan; Riana Ayu Kusumadewi
Journal of Community Based Environmental Engineering and Management Vol. 7 No. 1 (2023): Vol. 7 No.1, March 2023
Publisher : Department of Environmental Engineering - Universitas Pasundan - Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23969/jcbeem.v7i1.7251

Abstract

Krukut River is one of the rivers that has an important role to support the activities of the residents of Jakarta City. Krukut River has a length of 44.3 km. In 2015 the Krukut River was the target of a master plan for improving river water quality in Jakarta by Regional Environmental Management Agency (BPLHD) DKI Jakarta but in fact there was a decline in river water quality due to increasing population growth so that monitoring activities are needed. The purpose of the study is to identify the polluting sources of the Krukut River, analyze the water quality of the river, determine the pollutant load. The research parameters used are Biological Oxygen Demand (BOD) and Chemical Oxygen Demand (COD). Sampling in the Krukut River was carried out using the grab sampling method in September, October, November 2021 divided into 9 segments consisting of 9 non-point sources and 5 point sources. Non-point sources of pollutants are obtained from domestic waste dominated by residential areas, as well as food stalls, point source of pollutants are obtained from drainage channels, Mampang River, Ciliwung River, Cideng Channel and Krendang River. Pollutant load carrying capacity for BOD and COD concentrations in the Krukut River were respectively 292.896-622.592 kg/day and 2440.8-13521.6 kg/day. The pollutant load for BOD and COD concentrations in the Krukut River were respectively 2601.3-13792.2 kg/day and 3139.1-16542.6 kg/day.
The Use of A Static Mixer for The Coagulation Unit in The Duren Seribu II Water Treatment Plant Sheryline Putri Chandra Sari; Riana Ayu Kusumadewi; Winarni Winarni
Journal of Community Based Environmental Engineering and Management Vol. 7 No. 1 (2023): Vol. 7 No.1, March 2023
Publisher : Department of Environmental Engineering - Universitas Pasundan - Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23969/jcbeem.v7i1.7260

Abstract

In the drinking water treatment plant involves a significant component i.e., coagulation, which distributed coagulants vastly and equally through rapid stirring for destabilizing colloids and suspended particles in the raw water. In water treatment plants, coagulation units are often classified into mechanical and hydraulic coagulation.  This study aimed to discover the use of and in-line static mixers as coagulation in designing the Duren Seribu II Drinking Water Treatment Plant (WTP). The design criteria for coagulation unit in Duren Seribu II WTP was determined by comparing several data obtained from literature studies and evaluation of the existing conditions of Duren Seribu I WTP. Duren Seribu I WTP was evaluated by direct measurement in the field. From the results of data analysis, the design criteria appropriate for Duren Seribu II WTP, the G value is 2078.07 sec-1, the detention time (td) is 4 sec, and the G.td value is 8352.19.
PENERAPAN TANAMAN BUAH DALAM POT (TABULAMPOT) UNTUKKONSEP ECOMASJID DI MUSHOLA AL-AMIN DEPOK Hendrawan, Diana Irvindiaty; Rinanti, Astri; Wijayanti, Asih; Kusumadewi, Riana Ayu; Besila, Qurrotu 'Aini; Istri Anindya, Anak Agung; Sabrina, Lucky Maulina
JUARA: Jurnal Wahana Abdimas Sejahtera Volume 5, Nomor 2, Juli 2024
Publisher : Jurusan Teknik Lingkungan Fakultas Arsitektur Lanskap dan Teknologi Lingkungan, Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/dwpnw881

Abstract

Mushola Al-Amin merupakan sarana ibadah di RW 12 lingkungan perumahan Taman Duta, Cisalak, Depok. Mushola Al-Amin selain sebagai tempat ibadah juga melakukan kegiatan kemasyarakatan lainnya. Permasalahan mitra adalah belum memahami konsep ecomasjid dan belum dimanfaatkannya lahan di sekitar Mushola Al-Amin. Pengabdian Kepada Masyarakat (PKM) ini bertujuan memberikan penyuluhan tentang konsep ecomasjid dan memberikan pelatihan Tanaman Buah dalam Pot (tabulampot) sebagai implementasi konsep ecomasjid. Sasaran kegiatan adalah Lurah Cisalak, pengurus RW 12, pengurus RT, pengurus DKM Mushola Al-Amin dan ibu-ibu PKK RW 12.  Tabulampot adalah teknologi budidaya tanaman dengan memanfaatkan taman kecil yang produktif di dalam pot. Metode PKM adalah Penyuluhan dan Pelatihan. Materi PKM terdiri dari penyuluhan konsep ecomasjid dan tanaman buah dalam pot serta pelatihan menanam buah dalam pot. Hasil yang dicapai oleh peserta adalah meningkatnya pemahaman peserta tentang konsep ecomasjid dan dapat diterapkan pada Mushola Al-Amin sesuai dengan kondisinya dan meningkatnya pemahaman peserta tentang teknis tabulampot, sebagai pendukung konsep ecomasjid dan sebagai upaya kelestarian lingkungan. Hasil yang dicapai oleh komunitas yaitu lahan terbuka yang dimanfaatkan untuk tabulampot dan sebagai area rekreasi. Penghijauan pada lahan di sekitar Mushola AlAmin menerapkan konsep ecomasid ke 4 yaitu penanaman tanaman dan buah-buahan di sekitar masjid.  
PERBANDINGAN BIJI PEPAYA (Carica papaya l.) SEBAGAI BIOKOAGULAN DAN POLY ALUMUNIUM CHLORIDE (PAC) SEBAGAI KOAGULAN KIMIAWI PADA PENGOLAHAN AIR TANAH, KELURAHAN KOTA BAMBU SELATAN, JAKARTA BARAT Cahyaningrum, Nadia Amalia; Kusumadewi, Riana Ayu; ., Winarni; Aphirta, Sarah
Jurnal Reka Lingkungan Vol 12, No 3 (2024)
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/rekalingkungan.v12i3.299-313

Abstract

Air tanah di Kelurahan Kota Bambu Selatan mengandung kekeruhan dan TDS yang tinggi, sehingga harus diolah terlebih dahulu. Tujuan dari penelitian ini adalah untuk membandingkan hasil dan biaya pengolahan air tanah menggunakan biokoagulan biji pepaya dan koagulan PAC untuk menyisihkan parameter kekeruhan dan TDS. Metode yang digunakan adalah koagulasi dengan variasi G.td koagulasi 17.000, 34.000, 48.000, dan 96.000; flokulasi G.td 28.000; variasi dosis biokoagulan 100-500 mg/L; dan variasi dosis PAC 5-25 mg/L. Hasil dari pengolahan menggunakan biokoagulan biji pepaya telah menyisihkan kekeruhan dan TDS sebesar 96,54% dan 44,86%, sedangkan hasil dari PAC telah menyisihkan kekeruhan dan TDS sebesar 75,93% dan 17,57%. Penggunaan biokoagulan biji pepaya membutuhkan biaya sebesar Rp 254,26/liter dan penggunaan koagulan PAC membutuhkan biaya sebesar Rp 350,18/liter. Berdasarkan hasil tersebut dapat disimpulkan bahwa hasil penyisihan kekeruhan dan TDS pada air tanah dengan menggunakan biokoagulan biji pepaya lebih baik dibandingkan dengan menggunakan koagulan PAC dan juga penggunaan biokoagulan biji pepaya memiliki biaya yang lebih ekonomis dibandingkan dengan penggunaan koagulan PAC.
Pollutant Load Capacity of Rawa Besar Lake, Depok, West Java Junita, Alfira; Hendrawan, Diana Irvindiaty; Kusumadewi, Riana Ayu; Aphirta, Sarah
Journal of Community Based Environmental Engineering and Management Vol. 8 No. 2 (2024): September 2024
Publisher : Department of Environmental Engineering - Universitas Pasundan - Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23969/jcbeem.v8i2.12742

Abstract

Depok City has dozens of lakes and one of them is Lake Rawa Besar. The Depok government gives priority to Rawa Besar Lake to be development as a tourist destination. At this time the waters of Rawa Besar Lake are in a polluted condition caused by domestic waste, land use change, chicken farming and floating net caramba. The study aims to analyze water quality, determine the carrying capacity of pollutant loads and provide recommendations for pollutant load reduction. The calculation of the Pollution Load Capacity refers to Minister of Environment Regulation No. 28 of 2009. Based on water quality analysis, 5 parameters exceed the quality standard, such as BOD, COD, total phosphate, total nitrogen, and total coliform. Using the model and calculation of the pollutant load capacity of lake and/or reservoir.  The pollutant load capacity of Lake Rawa Besar for BOD parameters is 50.26 kg/year while the existing load is 262.76 kg/year, COD is 418.81 kg/year existing load is 1150.41 kg/year, phosphate is 0.50 kg/year existing load 26.45 kg/year, nitrogen 12.56 kg/year existing load 85.88 kg/year and total coliform 8.4 x 104 amount/year existing load 9.6x106 amount/year. The burden of incoming pollutants exceeds the pollutant load capacity of Lake Rawa Besar. Pollution control efforts are carried out by implementing communal wastewater treatment systems such as an Anaerobic Baffled Reactor (ABR).
Heat Transfer Analysis and Water Quality in Saline Water Desalination Using Solar Energy in Vacuum Condition Riana Ayu Kusumadewi; Suprihanto Notodarmodjo; Qomarudin Helmy
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY Volume 2, Number 1, October 2018
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v2i1.3556

Abstract

The continues deficiency of consumable water is a significant issue in developing countries, and contaminated water can result in various diseases, which are often lethal. Solar desalination seems to be a promising method and alternative way for supplying fresh water. Aim: The aim of this research is to study heat transfer in desalination system and the quality of feed water, distilled water and brine compared to the quality standard. Feed water consists of salinity 12‰ and 38‰ salinity. Methodology and Result: At first, initial characterization of feed water was conducted, then temperature on fourteen points was measured using thermocouples and thermometer so heat transfer rate can be calculated. After that, the final characterization of water production was conducted. From the  observation, it was found that evaporative heat transfer for vacuum pressure of -0.05, -0.1, -0.15, -0.2, -0.25, and -0.3 bar respectively were 173.77, 180.07, 190.79, 481.66, 242.57, and 246.24 W/m2. The result of water quality test of distilled water produced from saline water desalination for some parameters respectively were pH 7.4; turbidity 2.73 NTU; TDS 27.45 mg/L; chloride 84.98 mg/L; Fe 2.13 mg/L; total hardness 0.1698 mg/L; and Escherichia coli 12 cell/mL . Conclusion, significance and impact study: It can be concluded that distilled water produced by desalination system was met drinking water quality standard according to Minister of Health Regulation No. 492 of 2010.
TEMPORAL VARIATION OF GROUNDWATER QUALITY IN SLEMAN, YOGYAKARTA, INDONESIA Yureana Wijayanti; Markus Fittkow; Riana Ayu Kusumadewi; Oki Setyandito
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 1, OCTOBER 2021
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i1.10746

Abstract

Groundwater quality evaluation is important to gain an insight of contamination source. It can later be utilized to review the implementation of a water resource management policy in a specific region. Aim: This study evaluate the short-term temporal variation of groundwater quality and its possible contamination source in Sleman, Yogyakarta. Methodology and Results: the statistical approach was utilized using boxplot, principle component analysis (PCA) and correlation matrices, to the data for 50 sampling sites. The data of groundwater quality are available from the local environmental authority of Environmental Agency Sleman.The box plots revealed that groundwater quality might largely influenced by rainfall in the area. The factor loading of PCA presented that the ratio of concentration of both chloride and TDS are the most varied of all samples, and the less variable parameter is fluoride. The pair of groundwater quality parameter which had strong correlation were varied in each year, except for TDS and chloride that showed strong correlation in all three years. Nitrite had strong correlation with iron in 2017 and, nitrite also had strong correlation with both manganese and fluoride in 2019. The existence of fluoride in correlation with other parameter might give an insight of contamination from livestock wastes, where in the study area there are many poultry and cow farms, and small scale chicken slaughter industries. Conclusion, significant and impact study: This study gives preliminary understanding on temporal variation of groundwater quality, for further research on groundwater quality in Sleman, Yogyakarta.
STUDY OF MODIFIED PERFORATED BREAKWATER AS RENEWABLE ENERGY DEVICE Oki Setyandito; Novandy Novandy; Nizam Nizam; Martin Anda; Riana Ayu Kusumadewi; Yureana Wijayanti
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 5, NUMBER 2, APRIL 2022
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v5i2.13536

Abstract

Aim: This study investigates to determine the influence of wave steepness, relative freeboard, and breaker parameters on overtopping discharge at a perforated breakwater. Methodology and results: The research method used was using both a numerical model simulations on three-dimensional computational fluid dynamics (CFD) modelling software namely FLOW-3D; and empirical equation computation. The evaluation of both approaches were performed for understanding the characteristics of wave discharge that overtopping the perforated breakwater. The experimental results of modified perforated breakwater revealed that the lowest slope possible with the highest porosity possible can generate the highest value of dimensionless overtopping discharge for wave energy harvesting. Conclusion, significance and impact study: The findings of this study formulated the optimum slope and porosity to the highest wave energy harvested. Further studies recommend that data collection from onsite trials of modified perforated breakwater are performed.
ASSESSING GROUNDWATER QUALITY IN NORTH JAKARTA: A STATISTICAL APPROACH Yureana Wijayanti; Riana Ayu Kusumadewi; Nicholas Albert Wijaya; Lisma Safitri; Risky Ayu Kristanti
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY VOLUME 8, NUMBER 1, APRIL 2025
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/urbanenvirotech.v8i1.18152

Abstract

Aims: This study investigates the groundwater quality in North Jakarta. Methodology and results: The groundwater data from thirty-one sampling sites were analyzed for physical and chemical parameters such as total dissolved solids (TDS), pH, turbidity, nitrate (NO3), sulfate (SO4), chloride (Cl), manganese (Mn), fluoride (F), and iron (Fe). Principal Component Analysis (PCA) and Spearman’s correlation matrix were utilized to evaluate the contamination sources. Conclusion, significance, and impact study: The findings reveal significant variability in chloride and total dissolved solids (TDS) concentrations, while fluoride levels remained stable. Strong correlations were found between TDS and chloride, as well as, turbidity and iron, suggesting contamination from seawater intrusion and industrial activities. PCA identified four key components explaining 77% of the total variance. The first component, dominated by TDS, turbidity, iron, and chlorine, indicates ongoing seawater infiltration in the coastal aquifer. The second component, associated with turbidity, nitrate, and fluoride, indicates contamination from human activities. This study shows the value of multivariate statistical techniques like PCA, in assessing groundwater quality. The correlation matrix further confirms the influence of seawater on groundwater salinity and the presence of heavy metals, possibly due to soil disturbance. Moreover, there is an influence of geological and geographical factors, particularly the excessive groundwater extraction leading to seawater intrusion and groundwater quality deterioration.