Claim Missing Document
Check
Articles

Leveraging Geographic Information Systems for Polio Surveillance and Eradication: A Systematic Review Ahmed, Salmana; Imran, Mohammad; Ullah, Shafi; Azhar , Shanila; Mohammad Ashraf; Zahilah , Raja
Journal of Information Systems Engineering and Business Intelligence Vol. 12 No. 1 (2026): February
Publisher : Universitas Airlangga

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Background: The eradication of Polio virus is one of the important public health issues. In order to remove this virus, some well-planned methods are required. Objective: The aim of this paper is to assess GIS usage in different aspects of surveillance of polio virus. Specifically, the focus of this research is GIS applications, their practical challenges, and limitations in the context of polio viruses. Methods: Based on the systematic review of 36 peer reviewed studies across several academic research databases, we evaluated how GIS is used in polio control and eradication. Results: The findings include applications of GIS in several aspects. Few of these include vaccination coverage, analysis of disease patterns, and integration with existing healthcare information networks. Moreover, several important obstacles were also identified in context of shortcomings of data, infrastructure and expertise. Conclusion: The findings of this study offer useful guidance for healthcare workers and policymakers involved in eradication of polio viruses.   Keywords: Challenges, Geographic Information Systems (GIS), Polio virus, Surveillance, Systematic Review
Perencanaan Drainase di Jalan Goropaa RT 01/RW 01 Kelurahan Bugis Kota Gorontalo Ikhsan, Muhammad; Imran, Mohammad
Journal of Applied Geoscience and Engineering Vol 4, No 2 : Desember 2025
Publisher : Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37905/jage.v4i2.38266

Abstract

This study aims to formulate a practical drainage plan for Goropaa Street RT 01/RW 01, Bugis Village, Gorontalo City, based on field conditions and local construction costs. The study used a quantitative descriptive approach through site surveys, visual documentation, and direct measurement of the planned channel alignment. The technical design adopted the existing channel dimensions on the opposite side of the road to maintain flow continuity and simplify construction. Work volumes were calculated using basic geometric formulas for excavation, sand bedding, stone masonry, and plastering. Cost estimation was prepared using the work coefficients in the Circular Letter of the Directorate General of Construction Development Number 68/SE/Dk/2024 and local unit prices for materials and labor. The results show that the planned drainage channel length of 60.8 m requires an estimated budget of IDR 20.875.831,17. The plan is considered applicable because it uses dimensions that fit the site, relies on locally available materials, and can be implemented with relatively simple construction methods.
Analisis Instalasi Listrik Ruang Laboratorium Komputer Arsitektur Bangunan Gedung di Kampus 2 Universitas Negeri Gorontalo Imran, Mohammad; Teguh Isima, Mohamad
Journal of Multi Technology (J-Multitechno) Vol. 2 No. 1 (2026): Journal of Multi Technology (J-Multitechno)
Publisher : CV. Dalle' Deceng Abeeayla

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.69623/j-multitechno.v2i1.260

Abstract

Penelitian ini bertujuan untuk menganalisis instalasi listrik ruang laboratorium komputer Arsitektur Bangunan Gedung di kampus 2 Universitas Negeri Gorontalo dalam mendukung pengadaan komputer. Penelitian ini menggunakan pendekatan deskriptif kuantitatif untuk mengetahui kesesuaian kapasitas MCB dan sistem proteksi terhadap beban listrik dari 7 unit komputer dan 1 printer. Hasil analisis menunjukkan bahwa kapasitas MCB C50 (11000 W) berada pada batas maksimum dengan beban total sekitar 2050 W, tanpa adanya sistem pentanahan maupun ELCB. Disimpulkan bahwa secara teknis instalasi saat ini masih mampu menopang dan memenuhi standar keamanan.