Claim Missing Document
Check
Articles

Found 29 Documents
Search

Using Board Games as Anti-Corruption and Integrity Learning Media Sandri Justiana; Roto Priyono; Eko Nugroho
Journal of Games, Game Art, and Gamification Vol. 2 No. 2 (2017): Special Issue: International Conference of Games, Game Art and Gamification (IC
Publisher : Bina Nusantara University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21512/jggag.v2i2.7193

Abstract

One of the corruption eradication mandates assigned to the Corruption Eradication Commission (KPK) is to carry out anti-corruption education at each level of education, carry out anti-corruption public campaigns, and promote corruption eradication programmes (Law No 30/2001 on the Corruption Eradication Commission). To make anti-corruption education more effective, alternative media need to be developed that are more interesting and fun but do not detract from the essence and objectives of the learning itself. The KPK developed eight more anti-corruption and integrity board games for a wider audience, including young children, young people, students, educators, business people, and politicians. Board games are an interactive anti-corruption learning media that offer a unique way of looking at something, promote open communication, and challenge the players to work together to achieve results. Board games can be used an alternative learning media to instil anti- corruption values from a young age, and as a media for public anti-corruption promotion and campaign 
Pelatihan Duta UKS Dalam Meningkatkan Kesehatan Remaja Putri Di Boarding School Man 2 Surakarta Tria Puspita Sari; Nevia Zulfatunnisa; Eko Nugroho; Angela Syifa Anindya Faadihilah Purwanto; Romadhani Putri Wahyuningtyas
TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat Vol. 3 No. 2 (2023): TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat
Publisher : Fakultas Teknik, Universitas PGRI Banyuwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36526/tekiba.v3i2.3127

Abstract

The complex reproductive health issues faced by teenagers and the suboptimal implementation of the School Health Efforts (UKS) triad at the high school level have a significant impact on the health of students, particularly in improving reproductive health and promoting a clean and healthy lifestyle (PHBS). Madrasah Aliyah 2 Surakarta (MAN 2 Surakarta) is a private Islamic-based school in the city of Surakarta that has a Boarding School program for girls located not far from the main building. Based on observations, the condition of the UKS room in the girls' boarding school building does not meet the general UKS standards and the management of the UKS triad is not optimal. The aim of this community service is to improve UKS management facilities as a means of optimizing health improvement through trained UKS ambassadors. The method applied in this community service consists of Situational Analysis (Problems), Solutions, and Implementation of UKS Ambassador Training. The results of this community service show that the students were very enthusiastic about participating in the UKS ambassador training and there was an increase in knowledge before (pre-test 86.6%) and after (post-test 94.6%) training by 5%.
Si EMIL (Electric Maternity Belt) Untuk Monitoring Kesejahteraan Janin Dan Ibu Hamil 0-9 Bulan Purwaningsih, Heni; Nurul Istiqomah; Eko Nugroho; Tria Puspitasari; Hery Siswanto
TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat Vol. 5 No. 1 (2025): TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat (Januari)
Publisher : Fakultas Teknik, Universitas PGRI Banyuwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36526/tekiba.v5i1.4600

Abstract

Electric Maternity Belt for monitoring fetal and pregnant women well-being project is an initiative aimed at addressing the issue of inadequate fetal health monitoring in remote or underserved areas. Many expectant mothers face challenges in accessing timely prenatal care, which increases the risks of complications during pregnancy. This project developed an innovative, affordable, and easy-to-use maternity belt equipped with sensors to monitor the fetal heart rate, movement, and uterine contractions, providing real-time data to healthcare providers. The method involves collaboration with local health centers to test and refine the prototype. The maternity belt was introduced to rural clinics and tested on a sample of pregnant women, with training sessions for healthcare staff on how to operate the device. The results showed that the device successfully detected fetal abnormalities, allowing for early intervention and reducing maternal anxiety. Moreover, it contributed to the improvement of healthcare access by enabling remote monitoring, even in areas with limited medical resources. The primary output of this project is a functional prototype that can be mass-produced and distributed to remote areas, helping to ensure the safety of both mother and baby. The project’s contribution lies in its ability to bridge the gap between modern healthcare technology and rural communities, providing an affordable, efficient, and reliable solution for maternal and fetal health monitoring.
Rancang Bangun Alat Thermohygrometer Dilengkapi Sensor Pemantauan Gas Medik Junior Yudha Pamungkas; Weni Hastuti; Setyo Adi Nugroho; Eko Nugroho
Jurnal Mahasiswa Ilmu Kesehatan Vol. 2 No. 2 (2024): April: Jurnal Mahasiswa Ilmu Kesehatan
Publisher : STIKes Ibnu Sina Ajibarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59841/jumkes.v2i2.2667

Abstract

Thermohygrometer is a tool that functions to measure room temperature and humidity. The temperature and humidity in the operating room are set in the temperature range of 19˚C - 24˚C and humidity of 45% - 65%. Therefore, the operating room requires a good temperature and humidity control system to avoid damage to electronic components due to temperatures that are too low and humidity that is too high which causes corrosion. In addition, the influence of high concentrations of medical gas accelerates the rate of corrosion. Because medical gas consisting of CO and CO₂ gas contains oxygen as an oxidant gas. Therefore, a tool such as a Thermohygrometer is needed but equipped with a medical gas reading. This tool aims to read the conditions of temperature, humidity, and medical gas (CO & CO₂) so that it can be analyzed by Electromedics to regulate the air conditioning system. In addition, a Thermohygrometer system is made to allow data access from outside the operating room. The Thermhygrometer tool is made using two sensors, namely DHT22 and MQ-135. DHT22 is used to read temperature and humidity parameters, while the MQ-135 sensor is used to read the concentration of CO and CO₂ gases. The reading results are displayed on the I2C LCD screen. The components are integrated with ESP32 for data processing and as hardware that can be used to create a WiFi connection system. WiFi connectivity is needed to send data to the Blynk application. Testing by calibrating the DHT22 sensor and testing the suitability of the MQ-135 sensor with the gas analyzer. Based on the tests carried out, the temperature error value was obtained at -0.02% and humidity at -0.02%. While the error value was 0.32% for CO gas and -0.16% for CO₂ gas. The error value is still within the tolerance limit
EFEKTIVITAS PENYULUHAN MANAJEMEN PERALATAN MEDIS DALAM MENINGKATKAN KOMPETENSI TENAGA KESEHATAN Muh Hafid Alkarim; Eko Nugroho; Ipin Prasojo; Setyo Adi Nugroho
JURNAL MUTIARA ELEKTROMEDIK Vol. 9 No. 1 (2025): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v9i1.6323

Abstract

Peralatan Peralatan kesehatan merupakan komponen penting dalam peningkatan mutu pelayanan, sehingga diperlukan manajemen yang baik untuk menjamin keamanan dan efisiensi penggunaannya. Pengelolaan yang kurang tepat dapat menurunkan kualitas layanan dan membahayakan pasien, sehingga diperlukan intervensi edukasi berupa penyuluhan bagi tenaga kesehatan. Penelitian ini bertujuan mengetahui efektivitas penyuluhan manajemen peralatan medis dalam menurunkan kesalahan pengelolaan di Puskesmas Jayengan Surakarta. Penelitian menggunakan desain kuasi-eksperimental pre-post test one group tanpa kontrol dengan sampel total 30 tenaga kerja. Intervensi berupa penyuluhan selama 1 jam meliputi perencanaan, pengoperasian, pemeliharaan, kalibrasi, dan penghapusan peralatan. Instrumen berupa kuesioner 15 soal pre-test dan post-test, dianalisis menggunakan uji Wilcoxon Signed-Rank. Hasil menunjukkan rata-rata kesalahan menurun dari 3,03 menjadi 0,83 atau sebesar 72,5%, dengan p-value = 0,0000 yang menandakan perbedaan signifikan. Dengan demikian, penyuluhan manajemen peralatan medis terbukti efektif meningkatkan pemahaman tenaga kesehatan dan disarankan dilakukan rutin sebagai pengabdian masyarakat untuk mendukung mutu pelayanan.
Rancang Bangun Compact Automatic Tissue Processor dengan Arduino & Kontrol Suhu Realtime Tegar Pandu Atmojo; Eko Nugroho; Setyo Adi Nugroho; Nita Yunianti Ratnasari
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 4 No. 2 (2024): Juli: Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v4i2.6022

Abstract

Automatic tissue processor is a tool used in pathological examinations. Processing complex tissue can be quite troublesome for operators if done manually, considering that the tissue processing stage requires precision and precise timing. To reduce time inaccuracies which can cause tissue sample results to be less than optimal, an Automatic Tissue Processor tool was created. However, the existing Automatic Tissue Processor tools are usually designed with a large shape so that reagent consumption during tissue processing is also large, this is an obstacle in some small anatomical pathology labs or small hospitals with few patients, besides that real-time temperature monitoring is rare. is in the tool so that the user often does not know what the real-time temperature is, causing control of the quality of the paraffin reagent to be difficult. Starting from this, using the research and development (RND) method, this research designed an automatic tissue processor with 4 Chambers, the last 1 Chamber being The paraffin Chamber is equipped with a Heater and temperature controller, using a DHT-22 temperature sensor. where the Chamber is made with a compact size so as to save on the use of reagents, the temperature in the Chamber is set at a cutoff temperature of 60o C. The research results show that the tool can work well for temperature sensor accuracy which is obtained at a value of 100% with an error rate of 0%, then for The Timer accuracy level was obtained at 99.57% with an error rate of 0.43%..
Rancang Bangun Alat Blanket Warmer Berbasis Arduino Uno dengan Menggunakan Sensor DS18B20 M. Qi Bagus Maulana; Septi Aprilia; Eko Nugroho; Ida Untari
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 4 No. 2 (2024): Juli: Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v4i2.6024

Abstract

Blanket warmer is a tool to maintain the stability of the patient's body temperature when experiencing hypothermia, the blanket warmer will warm the patient until it reaches a normal body temperature of 36 - 37 °C. Some of the temperature setting options on the blanket warmer are 32°C, 38°C, and 43°C. To be able to design an Arduino-Based Warmer Blanket tool by using DS18B20 sensors.This study uses the research and development (RnD) method, which is a method used to make a product and test its effectiveness from the results of the product. The results of this study had a measurement difference of the instrument that could be used for patients with the highest temperature difference, namely 32°C = 0.11°C, 38°C = 0.20°C, 43°C = 0.11°C, the lowest measurement difference was 32°C = 0°C, 38°C = 0.01°C, 43°C = 0.02°C by comparing with a temperature measuring instrument. The average of all measurements in patients was 32°C = 32.64°C, 38°C = 38.70°C, 43°C = 43.72°C. The highest average error value from the 3 experiments was 1.45% and the lowest average error value from the 3 experiments was 0.26%. The Blanket Warmer tool using sensors DS18B20 safe for patients to use.
Pelatihan Peduli Sejiwa Dalam Optimalisasi Peran Duta UKS dan Tenaga Pendidik MAN 2 Surakarta Tria Puspita Sari; Wiwik Puspita Dewi; Eko Nugroho; Kania Alfa Anggara; Muthi’ah Nurul Jannah; Ekka Nur Cahyaningrum
TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat Vol. 6 No. 1 (2026): TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat (Januari)
Publisher : Fakultas Teknik, Universitas PGRI Banyuwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36526/tekiba.v6i1.6273

Abstract

Adolescents face increasingly complex health problems, particularly related to mental health, thus systematic efforts are needed to help them think critically and address the issues they experience. One strategy to improve students’ health status is by optimizing the School Health Efforts (UKS) integrated with the role of accompanying teachers. Madrasah Aliyah 2 Surakarta (MAN 2 Surakarta) is a private Islamic-based school where a situational analysis revealed low access to mental health information and suboptimal management of guidance and counseling services. Data show that around 80–90 students sought counseling in the past year with various problems such as learning motivation, family conflicts, and peer conflicts that required referral to psychiatrists. Although a counseling room facility is available, access to mental health literacy remains limited. Most students have not yet received adequate information on mental health, and teacher training in managing adolescent mental health is also still very limited. The purpose of this community service is to enhance and optimize the roles of School Health Ambassadors (Duta UKS) and educators through the *PEDULI SEJIWA* Program (Center for Self-Education and Mental Literacy for Adolescents with a Healthy Mind and Body) as an effort to improve students’ mental health. This activity is carried out through training, development of educational modules, and improvement of counseling room facilities. The methods applied in this program include situational analysis, socialization, and PEDULI SEJIWA training. The training results showed a 9% increase in knowledge from before (pre-test 91%) to after (post-test 100%).
Rancang Bangun Alat Lux Meter BH1750 Dengan Sensor Jarak HC-SR04 Untuk Uji Kesesuaian Kolimator Fitri Anindyahadi; Eko Nugroho; Setyo Adi Nugroho
Jurnal Kendali Teknik dan Sains Vol. 1 No. 1 (2023): Januari : Jurnal Kendali Teknik dan Sains
Publisher : International Forum of Researchers and Lecturers

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59581/jkts-widyakarya.v1i1.3150

Abstract

This research is based on the Regulation of the Nuclear Energy Supervisory Agency of the Republic of Indonesia Number 2 of 2018 concerning Conformity Tests for Diagnostic and Interventional Radiology One component that must be tested with a minimum passing standard of ≥ 100 lux at a distance of 100 cm. Data collection is obtained at the Calibration Agency to obtain accurate results. The purpose of this tool, the Lux Meter is equipped with a distance sensor to measure the light intensity of a collimator lamp with an intensity that must be ≥ 100 within a distance of 100 cm from the light source. So, making a tool that can be used to measure the amount of collimator illumination is accompanied by measuring the distance, so that it can ensure the results are in accordance with the limits that have been determined with a Lux Meter equipped with a distance sensor using the BH1750 module and the HC-SR04 module. For testing the tool made, it was compared with a Standard Lux Meter with the HIOKI brand, an average error value of 0.021 at a distance of 50cm, an error of 00.020 at a distance of 100cm, and an error of 0.022 was obtained, while for testing the distance sensor it was compared with a Standard Meter with the FLUKE brand. The average percentage error value is 0.002 at a distance of 50cm, an error of 0.011 at a distance of 100cm, and an error of 0.008 at a distance of 130cm.