Claim Missing Document
Check
Articles

Found 34 Documents
Search

Stabilitas Whole Blood Control Tiga Level Yang Disimpan Pada Suhu 2-8oC Menggunakan Alat Hematology Analyzer Caesaria, Adela; Handayati, Anik; Puspitasari, Ayu
Jurnal Analis Kesehatan Vol. 12 No. 1 (2023): JURNAL ANALIS KESEHATAN
Publisher : Department of Health Analyst, Politeknik Kesehatan, Kementerian Kesehatan Tanjungkarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26630/jak.v12i1.3492

Abstract

Quality assurance is important to ensure that the quality system runs properly and guarantees the results of laboratory tests, one of which is the inspection of control materials. The control material requirement is to have long stability, blood-like characteristics and low price. From these conditions, commercial control materials have a longer stability than fresh blood but are expensive. In practice, commercial control materials are still used even after the expiry date of the materials has passed. This is because the availability of materials is often delayed, the procurement of materials takes a long time and the price is relatively expensive. Therefore, this study aims to determine the stability of commercial whole blood control stored at 2-8oC. This research is an experimental analytic study with a cross sectional research design. The sample in this study was commercial whole blood control with 3 levels, namely normal, low abnormally and abnormally high levels which were stored at 2-8oC and checked every week for 10 weeks. Based on the test results obtained p-value for each parameter at all levels on the parameters of the number of erythrocytes, leukocyte count, hematocrit, hemoglobin and platelet count. Based on the results, it can be concluded that there is no change in the stability of whole blood control with storage for 10 weeks at a temperature of 2-8oC on the parameters of abnormally low and normal leukocyte count levels, abnormally low and abnormally high hematocrit levels, and all levels on the parameters of leukocyte count, hemoglobin and platelet count. Meanwhile, in the normal level of hematocrit parameters and abnormally high leukocyte count, there is a change in stability.
PERBANDINGAN HASIL LAJU ENDAP DARAH METODE WESTERGREN DENGAN MENGGUNAKAN ANTIKOAGULAN EDTA DAN NATRIUM SITRAT 3,8% PADA WANITA MENSTRUASI Atsania Putri , Puji Lestari; Anik, Handayati; Sri Sulami , Endah Astuti
Analis Kesehatan Sains Vol. 10 No. 1 (2021): Analis Kesehatan Sains
Publisher : Politeknik Kesehatan Kementerian Kesehatan Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The Erythrocyte sedimentation rate is a routine blood test performed to monitor the course of the disease where high values ​​are likely to be associated with the presence of inflammation. ICSH (International Council for Standardization in Hematology) recommends the Westergren method as a method for examining LED with several developments in terms of the anticoagulants and diluents used. Anticoagulants that can be used are Sodium Citrate 3,8% anticoagulant and EDTA (Ethylene Diamine Tetra-Acetid-Acid) anticoagulant. This study aims to determine the differences in the erythrocyte sedimentation rate of the westergren method using EDTA anticoagulants and sodium citrate 3.8%.This study uses primary data collection techniques with comparative research type. The research was conducted at the Health Analyst Laboratory of Poltekkes Kemenkes Surabaya, in January-April 2021. The sample of the study was 50 menstruating women who had met several criteria, who would be examined for LED values ​​using the Westergren method using EDTA anticoagulants in purple vacuum tubes and sodium citrate 3,8 % on a black vacuum tube.The results showed that the mean of sedimentation rate with EDTA anticoagulant was 27.66 mm/hour and 22.04 mm/hour for sodium citrate 3,8% anticoagulant. The statistical test was carried out by using the paired sample t-test which showed the sig (p) value = 0.000 0.05, so it could be concluded that there was a difference between the EDTA anticoagulant LED and the sodium citrate anticoagulant LED. Thus the EDTA anticoagulant can still be used as an anticoagulant in examining the erythrocyte sedimentation rate
HUBUNGAN JUMLAH SEL NEUTROFIL DENGAN KADAR TROPONIN I PADA PENDERITA INFARK MIOKARD AKUT Hikma , Candra Triana; Anik, Handayati; Sri Sulami , Endah Astuti
Analis Kesehatan Sains Vol. 10 No. 2 (2021): Analis Kesehatan Sains
Publisher : Politeknik Kesehatan Kementerian Kesehatan Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36568/anakes.v10i2.20

Abstract

Acute Myocardial Infarction (AMI) is a heart disease condition due to heart muscle cells not getting enough blood flow and oxygen due to atherosclerosis of the coronary arteries. When the condition of atherosclerosis gets worse, it will cause an inflammatory reaction, causing an increase in neutrophils. Inflammation due to atherosclerosis will worsen blood flow to the heart, resulting in heart muscle necrosis which causes an increase in biochemical markers, namely cardiac troponin. The aim of this research is to determine the relationship between the number of neutrophil cells and troponin I levels in patients with Acute Myocardial Infarction.This type of research is a cross-sectional analytic observational with a retrospective approach. This research was conducted on patients with Acute Myocardial Infarction at the RSPAL dr. Ramelan Surabaya who performed a complete blood count and troponin I level with a period of January 1st 2020 – May 3rd 2021, taken by purposive sampling. The results showed that male respondents were 29 patients (63%) while female respondents were 17 patients (37%). Respondents aged 65 years amounted to 28 (61%) people, while respondents aged 65 years were 18 (39%) people. The results of the hypothesis test have a sig value of 0.000 < (0.05), so there is a relationship between the number of Neutrophil cells and Troponin I level in patients with Acute Myocardial Infarction. In hypothesis testing, the correlation coefficient value is 0.594, which means that there is a moderate relationship with a positive direction.
Indeks Eritrosit dan Kadar Retikulosit Hemoglobin (Ret-He) pada Ibu Hamil dengan Anemia Defisiensi Besi Fridayanti, Ni Made Risma; Handayati, Anik; Rahayuningsih, Christ Kartika
Jurnal Penelitian Kesehatan SUARA FORIKES 2022
Publisher : FORIKES

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33846/sf13nk352

Abstract

Anemia of pregnancy is a condition of the body with hemoglobin levels in the blood <11g% in the 1st and 3rd trimesters. The erythrocyte index is used as a screening test to diagnose anemia based on its morphology. Ret-He is a new parameter that functions to assess iron in the body. This study aims to analyze the relationship between red blood cell index and reticulocyte hemoglobin (Ret-He) levels in pregnant women with iron deficiency anemia. The study design was cross-sectional involving 15 pregnant women at Wangaya Hospital, Denpasar. The measurement results data were then analyzed using the Pearson correlation test. The results showed that the mean MCV = 70.04 fL, average MCH = 24.05 pg, average MCHC = 27.48 g/dL, average Ret-He = 23.64 pg. The results of statistical analysis on the correlation between Ret-He and MCV, MCH and MCHC, showed p values were 0.004 for MCV, 0.001 for MCH and 0.793 for MCHC respectively. The conclusion of this study is that there is a relationship between Ret-He and MCV and MCH.Keywords: erythrocyte index; Ret-He; iron deficiency anaemia ABSTRAK Anemia kehamilan adalah kondisi tubuh dengan kadar hemoglobin dalam darah <11g% pada trimester 1 dan 3. Indeks eritrosit digunakan sebagai pemeriksaan penyaring untuk mendiagnosis terjadinya anemia berdasarkan morfologinya. Ret-He merupakan suatu parameter terbaru yang berfungsi menilai zat besi dalam tubuh. Penelitian ini bertujuan untuk menganalisis hubungan antara indeks eritrosit dengan kadar retikulosit hemoglobin (Ret-He) pada ibu hamil dengan anemia defisiensi besi. Rancangan penelitian ini cross-sectional yang melibatkan 15 ibu hamil di RSUD Wangaya, Denpasar. Data hasil pengukuran selanjutnya dianalisis menggunakan uji korelasi Pearson. Hasil penelitian menunjukkan bahwa rerata MCV = 70,04 fL, rerata MCH = 24,05 pg, rerata MCHC = 27,48 g/dL, rerata Ret-He = 23,64 pg. Hasil analisis statistik pada korelasi antara Ret-He dengan MCV, MCH dan MCHC, menunjukkan nilai p masing-masing adalah 0,004 untuk  MCV, 0,001 untuk MCH dan 0,793 untuk MCHC. Kesimpulan penelitian ini adalah ada hubungan antara Ret-He dengan MCV dan MCH.Kata kunci: indeks eritrosit; Ret-He; anemia defisiensi besi
The Relationship Between TSH and Indirect Bilirubin Levels in Neonates Suspected of Having Jaundice Alizah, Nur; Handayati, Anik; Museyaroh, Museyaroh; Suhariyadi, Suhariyadi
Health Dynamics Vol 1, No 10 (2024): October 2024
Publisher : Knowledge Dynamics

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33846/hd11006

Abstract

Background: Congenital hypothyroidism (CH) is a condition of thyroid hormone deficiency that occurs at birth. The TSH (thyroid-stimulating hormone) test is crucial for diagnosing hypothyroidism. CH is known to cause prolonged unconjugated hyperbilirubinemia. Therefore, this study aimed to analyze the relationship between TSH and indirect bilirubin levels in neonates suspected of having jaundice. Methods: This is a non-experimental, retrospective study conducted at Lombok Dua Dua Lontar Mother and Child Hospital in Surabaya. The study involved data collection on neonates aged 2–7 days suspected of jaundice, whose TSH and indirect bilirubin levels were measured between November 2022 to April 2024. Results: Among 100 neonates, 62% were aged 2-4 days, while 38% were aged 5-7 days. The majority were male (56%), with female comprising 44%. Of the 100 neonates, only 1 (1%) had borderline TSH levels, while 99% had normal TSH levels. Hyperbilirubinemia was observed in 94% of the neonates, while 6% had normal indirect bilirubin levels. Statistical analysis using the Spearman correlation showed no significant link between TSH and indirect bilirubin levels (p = 0.802). Conclusions: While this study did not find a clear connection between TSH and indirect bilirubin levels in neonates suspected of having jaundice, one case of borderline TSH was identified. This neonate required referral to pediatric endocrinology, as untreated congenital hypothyroidism can lead to mental retardation. Despite limited research linking TSH and bilirubin levels in jaundiced neonates, routine screening for congenital hypothyroidism using TSH testing should be reconsidered. Future studies could benefit from focusing on specific causes of neonatal jaundice to help narrow down research questions in this area.
Correlation between ESR and hs-CRP Levels with HbA1c in diabetes mellitus patients Farah Adelia Qotrunnada; Anik Handayati; Museyaroh; Lully Hanni Endarini
JHeS (Journal of Health Studies) Vol. 8 No. 2 (2024): September
Publisher : Universitas 'Aisyiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31101/jhes.3747

Abstract

Subclinical inflammation and almost every indication of systemic inflammation, which is defined by elevated levels of inflammatory markers in the blood, are seen in patients with diabetes mellitus (DM). Understanding the relationship between inflammatory markers and glycemic control is essential for creating comprehensive management strategies to avoid diabetes-related complications. The aims of this study were to determine the correlation between erythrocyte sedimentation rate (ESR) and high-sensitivity C-reactive protein (hs-CRP) and glycated hemoglobin (HbA1c) in DM patients. This was an analytical observational study with a cross-sectional design that was conducted on 35 DM patients from the DM prolanis group at the Bangkalan Regency First-Level Health Facility. HbA1c and hs-CRP levels were measured using the fluorescence immunoassay (FIA) method, while ESR was assessed using the Westergren method. Statistical analysis was performed using the Spearman correlation test. Regarding the biomarkers, all respondents (100%) had HbA1c levels >8.0%, 43% had elevated hs-CRP levels associated with cardiovascular risk, and 80% had abnormal ESR values. A significant relationship was found between ESR and HbA1c (p = 0.019; r = 0.394), but no significant relationship was observed between hs-CRP and HbA1c (p = 0.351; r = 0.163). The relationship between inflammation and glycemic control in DM can be understood through the correlation of ESR, hs-CRP, and HbA1c. These findings offer practical value, particularly in monitoring disease progression and managing diabetes-related complications. Future research should investigate the effects of interventions aimed at reducing inflammation, e.g lifestyle modifications or anti-inflammatory medications, on ESR, hs-CRP, and HbA1c levels.
Variance Index Score (Vis) Evaluation Of Homemade And Commercial Control Sera On Ast And Alt Assays Rahmania, Adelia Prisma; Handayati, Anik; Museyaroh, Museyaroh; Haryanto, Edy
Jurnal Riset Kesehatan Vol 13, No 2 (2024): NOVEMBER 2024
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jrk.v13i2.11778

Abstract

Control materials are used as indicators of monitoring the performance of laboratory examinations so that the results issued are valid. Method of assessing the implementation of External Quality Assurance (EQAS) used Variance Index Score (VIS). This study aims to determine difference between pooled sera, homemade and commercial lyophilizates on AST and ALT parameters based on VIS. This research used comparative descriptive with quantitative approach in December 2023-May 2024. Homemade lyophilizates performed at UBAYA technobiology laboratory, determination of true value performed at 2 reference laboratories and clinical chemistry laboratory Poltekkes Surabaya, and determination of VIS performed at 10 primary level clinical laboratories in Surabaya Raya which determined by purposive sampling. The statistical analysis results showed no difference between homemade and commercial control materials based on VIS to the true value and all participating laboratories, so it was concluded that homemade control materials could be used as a substitute in implementing EQAS.
Pap Smear Diagnostic Test Towards Gold Standard Histopathology In Cervic Cancer: Uji Diagnostik Pap Smear Terhadap Gold Standard Histopatologi Pada Kanker Serviks Anik Handayati; Putri, Tiara Dewanti; Sri Sulami Endah Astuti
Medicra (Journal of Medical Laboratory Science/Technology) Vol. 7 No. 2 (2024): December
Publisher : Universitas Muhammadiyah Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/medicra.v7i2.1655

Abstract

Cervical cancer is the second most common cancer in the world. Screening examination plays an important role in early detection of cervical cancer so that it can reduce mortality. Pap smear is an initial examination to detect the presence of abnormal cells in the cervix. This study aims to determine the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of pap smear examination by comparing them to histopathological examination as the gold standard. The design of this study was an observational study with secondary data obtained from the medical records of cervical cancer patients who had performed pap smears as well as histopathological examinations at the Anatomical Pathology Laboratory Installation, RSPAL dr. Ramelan Surabaya for the period January 2020 to March 2022. The data will be sorted based on inclusion and exclusion criteria. Data that pass the inclusion criteria will be tested using crosstabulation and then proceed to the diagnostic test. The sensitivity value is 97%, specificity value is 88%, accuracy value is 96%, positive predictive value is 98%, and negative predictive value is 79%. Pap smears have a fairly good diagnostic value for diagnosing cervical cancer.
Pemberdayaan Kader Kesehatan Dan Keluarga Pasien Tuberkulosis Dalam Pemanfaatan Sambiloto Sebagai Imunomodulator Untuk Keberhasilan Pengobatan Pasien Tuberkulosis Di Wilayah Kerja Puskesmas Gading Kecamatan Tambaksari Kota Surabaya Pestariati, Pestariati; Handayati, Anik; Suhariyadi, Suhariyadi
Sewagati Vol 9 No 3 (2025)
Publisher : Pusat Publikasi ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j26139960.v9i3.2276

Abstract

Indonesia memiliki beban kasus tuberkulosis tertinggi ketiga di dunia. Tahun 2021, jumlah kasus tuberkulosis di Indonesia 824.000 kasus, hanya 402.502 kasus (49%) dari target 85% berhasil ditemukan dan diobati . Indikator keberhasilan pengob- atan di Jawa Timur tahun 2020 sebesar 87,1% (Target renstra Kemenkes 90%). Hal ini disebabkan salah satunya rendahnya pemahaman kader kesehatan, keluarga dan pasien tuberculosis tentang penyakitnya, termasuk bahaya resistensi OAT dan dukun- gan keluarga terhadap kesembuhan pasien. Sambiloto memiliki kandungan senyawa andrografolida, sebagai imunomodulator, meningkatkan keberhasilan pengobatan TB. Kader kesehatan berperan mengedukasi masyarakat tentang TB, memberikan dukungan dan motivasi kepada pasien TB,memfasilitasi kolaborasi antara pasien TB. Setiap Kelurahan Wilayah Puskesmas Gading memiliki Kader Kesehatan yang khusus menangani TB Pada Kelurahan di wilayah Puskesmas Gading, warga memi- liki tanaman Sambiloto baik dilakukan di Pot atau masuk di dalam TOGA RT. Pengabdian memberikan edukasi tentang tuberkulosis dan pemanfaatan sambiloto sebagai imunomodulator kepada kader kesehatan /TB dan keluarga pasien TB. Pen- ingkatan pemahaman kader dan keluarga pasien TB tentang sambiloto (N-Gain > 0,7) berhasil menurunkan angka BTA positif dari 84% menjadi 37,5%, sehingga edukasi (KIE) berkelanjutan sangat diperlukan.
Korelasi Kadar Troponin I dengan Serum Glutamic Oxaloacetic Transaminase (SGOT) dan Low Density Lipoprotein (LDL) Pada Penderita Penyakit Jantung Koroner Di RSUD Haji Provinsi Jawa Timur Amania, Salsabila; Handayati, Anik; Museyaroh
Journal of Indonesian Medical Laboratory and Science Vol 6 No 2: Oktober 2025
Publisher : Asosiasi Institusi Pendidikan Tinggi Teknologi Laboratorium Medik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53699/joimedlabs.v6i2.279

Abstract

Background: Coronary Heart Disease (CHD) is a condition caused by atherosclerosis, which leads to reduced blood supply to the heart muscle. This condition occurs due to the buildup of plaques resulting form elevated levels of LDL.  Atherosclerosis can trigger myocardial infarction, leading to heart muscle damage and the release of biomarkers such as Troponin I and Serum Glutamic Oxaloacetic Transaminase (SGOT). Objectives: This Study aims to determine the correlation between Troponin I levels and SGOT as well as LDL levels in patients with CHD at Haji General Hospital in East Java Province. Materials and Methods: This study used an analytical observational study with a cross-sectional and purposive sampling. Results: The study results show that the majority of participants were aged 46–65 years (57%) and male (57%). Most patients had high Troponin I levels (70%), normal SGOT levels (63%), and high LDL levels (100%). The correlation analysis using the Spearman test showed a statistically significant correlation between Troponin I and SGOT levels with p value 0.046 and correlation coefficient r= 0.367, but the correlation between Troponin I and LDL levels was not statistically significant with p value 0.330 and correlation coefficient = 0.184. Conclusions:  The study found a correlation between Troponin I and SGOT in patients with CHD and no correlation between Troponin I and LDL in patients with CHD.