Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Journal of Infrastructure Planning and Engineering

Column structure strengthening with FRP (Fiber Reinforced Polymer) due to story addition I Wayan Maesa Andreasnata; I Nengah Sinarta; Ni Komang Armaeni; I. P. Ellsa Sarassantika; Dang Thanh Trung; Cintantya Budi Casita; Roro Sulaksitaningrum; Sudarno P. Tampubolon
Journal of Infrastructure Planning and Engineering (JIPE) Vol. 1 No. 1 (2022)
Publisher : Master Program of Infrastructure and Environmental Engineering, Postgraduate Program, Warmadewa University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (874.626 KB) | DOI: 10.22225/jipe.1.1.2022.38-45

Abstract

This study focuses on strengthening scheme of an existing structure with added story. The addition of a new story increases gravitational loading, which affects the seismic and wind responses of the structure and, as a consequence, the loading combination. To ensure the structure’s capacity requirement, the strengthening scheme uses CFRP (Carbon Fiber Reinforced Polymer). In order to adequately define the structure's performance, a series of structural analyses were performed. The structure's state before and after story addition, subsequently the state after CFRP strengthening, were evaluated. It is demonstrated that the additional story to the structure causes an exceedance in internal forces; however, the strengthening with CFRP is sufficient to withstand these forces, proving that the strengthening scheme is effective and beneficial.
The Performance Analysis of High-Rise Building Structure Based on SNI 03-1726-2012 and SNI 03-1726-2019 (Case Study: Tower 1 Transit-Oriented Development Apartment Pondok Cina, Depok) Sudarno Tampubolon; Pinondang Simanjuntak; Gracela P. Tarapandjang; I Putu Ellsa Sarassantika
Journal of Infrastructure Planning and Engineering (JIPE) Vol. 2 No. 1 (2023)
Publisher : Master Program of Infrastructure and Environmental Engineering, Postgraduate Program, Warmadewa University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22225/jipe.2.1.2023.36-41

Abstract

Indonesia has the latest seismic standard, namely SNI 03-1726-2012 which replaces the previous seismic standard, namely SNI 03-1726-2012. This study aims to compare the calculation and analysis of the result of the Transit-Oriented Development (TOD) apartment in Pondok Cina, Depok based on SNI 03-1726-2012 and SNI 03-1726-2019 and find out what parameters make a significant difference between SNI 03-1726-2012 and SNI 03-1726-2012. SNI 03-1726-2019. From the comparison results, there was an increase in the parameter values ​​of SS and S1 in SNI 03-1726-2019, resulting in the influence of the parameter values ​​of SDS and SD1 which became the reference for calculating the acceleration value of the response spectra in SNI 03-1726-2019. The value of the basic static shear force in the X and Y directions in SNI 03-1726-2019 increased by 18% from the value of the basic static shear force in SNI 03-1726-2012 and the value of the dynamic basic shear force in the X and Y directions in SNI 03-1726- 2019 experienced an increase of 15% from the value of the dynamic base shear force in SNI 03-1726-2012. The basic shear force increases because the acceleration spectral design response has a high increase in 03-1726-2019 compared to SNI 03-1726-2012. Based on the control of the performance level of the Transit-Oriented Development (TOD) apartment building, Pondok Cina Depok, is included in the Immediate Occupancy, meaning that when an earthquake occurs, the building does not suffer heavy damage, can still be used and the risk of casualties is very small. Performance-based planning can provide information on how the building behaves during an earthquake and the extent to which the earthquake will affect the structure.