BENEFITS OF STEEPING BLACK TEA AS A NEGATIVE CONTRAST MEDIUM ON CT UROGRAPHY EXAMINATION Yudha, Sagita; Hadisaputro, Suharyo Hadisaputro; Ardiyanto, Jeffri; Mulyantoro, Donny Kristanto; Masrochah, Siti
Journal of Applied Health Management and Technology Vol. 2 No. 2 (2020): April 2020
Publisher : Postgraduate Program , Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jahmt.v2i2.5697

Abstract

The use of water as a contrast medium requires large amounts of water to fill the lumen of the Urinary Tractus and more water is reabsorbed by the body than is secreted into urine. Steeping Black tea contains Caffeine which is able to increase blood flow in the kidneys thus inhibiting the process of absorption of Na, Ca and Mg causing stimulation of the kidneys to increase the amount of urine production. The purpose of this study is to prove that drinking black tea can increase urine production as a negative contrast medium to see differences in the distension and density of the Urinary Tract on CT Urography examination. This type of research uses True Experimental with Pretest-Posttest Control Group Design research design. Patients selected by Simple Random Sampling. Analysis: Paired t test and Independent t test. The results of the study of the use of 600 ml steeping Black Tea as a negative contrast medium on CT Urography examination did not show the difference in mean difference between the left renal Pelvis p value 0.956, Left UVJ 0.640, Right UVJ 0.935 while on the right renal Pelvis p value 0.001 showed differences in mean difference between the left renal Pelvis p value 0.956, Left UVJ 0.640, Right UVJ 0.935 while on the right renal Pelvis p value 0.001 intervention and control group. Hasil pengukuran p value  densitas Vesika urinaria sebesar 0,678. Conclusion: Black tea can be used as a negative contrast medium on CT Urographic examination but when compared with mineral water it does not show a significant difference.
TECHNICAL APPLICATION OF DENOISING KALMAN FILTER FOR ARTIFACT REDUCTION IN MRI ANATOMIC IMAGE INFORMATION Puspitaningtyas, Dyah Ayu; Mulyantoro, Donny Kristanto; Sudiyono, Sudiyono
Journal of Applied Health Management and Technology Vol. 3 No. 1 (2021): January 2021
Publisher : Postgraduate Program , Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jahmt.v1i1.6571

Abstract

Fatsups and BLADE sequences are used to reduce artifacts and clarify anatomical images. Basedon theoretical studies, the STIR, BLADE sequences, the addition or subtraction of parameters, and theaddition of artificial intelligence used still have a weakness, namely increasing the scanning time to belonger. Another technique that can be used and sequences and parameters on MRI is the denoisingKalman filter technique in the Matlab (Matrix Laboratory) program. The denoising technique is appliedafter the scanning process. Denoising will not increase the MRI scanning time. This systematic reviewaims to know the technical application of denoising Kalman filter for reduction artifacts on MRIexamination. The search was done using google scholar, WILEY, IEE Explore, SPRINGER,PERPUSNAS, and Scopus in English with 2004-2020 articles period. The keywords are MRI artifact,reducing artifacts, and the Kalman filter algorithm. A review of 4 articles of filter Kalman intervention onMRI Brain, MRI Abdomen, and MR Cardiac shows that the Kalman filter is good enough to reduceartifacts and improve anatomical information. The Kallman filter could reduce flow artifacts, improveimage quality and clarify anatomical images on MRI.