Inspeksi sambungan las pada pipa steam generator menggunakan metode radiography teknik panoramic (studi kasus di PT. Tachi Jino) Muhammad Zaky; Syukran Syukran; Azwar Azwar
Jurnal POLIMESIN Vol 15, No 2 (2017): Agustus
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v15i2.374

Abstract

Inspeksi Sambungan Las Pada Pipa Steam Generator Menggunakan Metode Radiography Teknik Panoramic (Studi Kasus Di PT. Tachi Jino) dengan membuat perhitungan Exposure Time menggunakan Komputasi. Tulisan ini membahas tentang Penyinaran menggukan teknik Panoramic pada sambungan las pada pipa steam generator yang berukuran 10 inchi (Schedule Pipe-40) yang ada pada PT. Cladteck Bi Metal, Batu Ampar, Batam, Kepualauan Riau. Tujuan dari Inspeksi ini adalah, melakukan Penyinaran dengan teknik panoramic, membuat kalkulasi menggunakan Komputasi pada perhitungan Radiography. Pengoprasian ini di lakukan dengan kamera Radiography tipe Gamma Ammersham 661 Co-60 yang berkapasitas 150 Ci. Dari hasil yang sudah diperhitungkan, waktu penyinaran (Exposure Time) yang digunakan adalah perhitungan dengan menggunakan Komputasi yaitu 81 detik dengan nilai film error 0,88 % lebih sedikit dibandingkan dengan menggunakan rumus teknik (manual) yaitu 71 detik dengan nilai film error sebesar 11,4 %. Pada proses penyinaran Radiography Operator menggunakan perhitungan Komputasi, dari hasil penyinaran yang diketahui bahwa pada posisi 0-15 terdapat Porosity yang cukup signifikan sehingga perlu adanya repair atau pengelasan kembali dan dinyatakan reject oleh Interpreter. Sedangkan pada posisi 15-30 memiliki las-lasan yang cukup memenuhi syarat, sehingga dinyatakan clear oleh Interpreter dan pada posisi 30-0 terdapat Lack Of Fusion yang cukup signifikan sehingga perlu adanya repair atau pengelasan kembali dan dinyatakan reject oleh Interpreter. Pada akhirnya hasil dari film sangat berpengaruh pada waktu Exposure Time.Kata Kunci : Steam Generator, metode radiography teknik panoramic, kamera gamma ammersham   661 Co 60, exposure time, lack of Fusion
Effect of welding repair on mechanical properties of ASTM A36 carbon steel weld joints Azwinur, Azwinur; Syukran, Syukran; Akhyar, Akhyar; Tho, Nguyen Huu; Jaswir, Jaswir
Jurnal Polimesin Vol 20, No 2 (2022): August
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v20i2.3075

Abstract

The welding repair process greatly affects the procedure of a welding process to be able to obtain the results of a connection that is safe and in accordance with its provisions. The strength of the welded joint must be considered and ensured that its strength is at least close to the original strength of the material used. In a welding process, errors or omissions are often made accidentally by the welder or the work environment and the selection of welding variable parameters is not appropriate so that welding defects occur. Welding defects can affect the strength of the weld joint. The purpose of this study was to determine the effect of welding repair on the mechanical properties of ASTM A36 material. The material used in conducting this research and testing is ASTM A36 steel plate. Welding was carried out on 4 specimens with the method without repair, repair 1x, repair 2x and repair 3x. Based on the test results, the number of repairs greatly affects the strength of the material connection. The highest maximum tensile strength value in 1 repair specimen is 501.90 Mpa and the lowest is in unwelded material or base metal of 467.97 Mpa. The results of the highest hardness test on the repair material 1 time of 30.83 HRC in the weld metal area and the lowest hardness value on the repair specimen 3 times in the HAZ area of 21 HRC. The results of the macro photo test on each specimen did not detect any welding defects on the inside of the welded material. the largest HAZ width in the 3 times repair material is 21.5 mm and the smallest HAZ width in the specimen without repair is 18 mm