Artesis Journal is scientific journal published periodically every 6 (six) months (in May and November) by Department of Civil Engineering, Faculty of Engineering - Universitas Pancasila. It contains papers related to student or student-lecturer research activities. Artesis Journal has an area of expertise consisting of Structural Engineering, Construction Engineering & Management, Geotechnical Engineering, Water Resources Engineering, and Transportation Engineering.
Articles 183 Documents
ANALISIS PENGENDALIAN PROYEK KONSTRUKSI MENGGUNAKAN METODE EARNED VALUE DAN EARNED SCHEDULE, SERTA MANAJEMEN MATERIAL: Studi Kasus di Proyek Rancang Bangun Rumah Susun Stasiun Tanjung Barat Salsabilla, Kesha; Andreas, Azaria
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5918

Abstract

Dalam pelaksanaannya suatu proyek konstruksi memerlukan manajemen waktu dan biaya untuk mengendalikan proyek agar tercapainya pelaksanaan proyek yang memiliki nilai efisiensi, kinerja, dan yang lebih baik. Metode pengendalian pda penelitian ini ialah Metode Earned Value dan Earned Schedule. Metode Earned Value dapat memberikan peramalan durasi akhir proyek menggunakan ruang lingkup biaya dan waktu, sedangkan Metode Earned Schedule memiliki unsur utama dalam analisisnya menggunakan jadwal proyek sebagai alat ukur efisiensi kinerja proyek yang berbasis waktu. Penelitian ini bertujuan untuk mengetahui faktor penyebab Proyek Rancang Bangun Rumah Susun Stasiun Tanjung Barat mengalami keterlambatan, menganalisa pencapaian kinerja pelaksanaan proyek dengan peramalan durasi akhir proyek dapat terselesaikan dengan perbandingan dari dua metode pengendalian, dan penerapan manajemen material proyek. Hasil wawancara bersama dengan Manager Engineer dapat disimpulkan bahwa dari total 43 variabel faktor penyebab keterlambatan proyek ditemukan 31 variabel berpengaruh terhadap kinerja waktu proyek. Berdasarkan hasil perhitungan pada Metode Earned Value estimasi durasi akhir pelaksanaan proyek pada perhitungan EAC(t) di minggu ke-312 selesai di minggu ke-342 dimana sesuai dengan perencanaan. Sedangkan pada Metode Earned Schedule estimasi durasi akhir pelaksanaan proyek pada perhitungan IEAC(t) di minggu ke-312 selesai di minggu ke-340 dengan 2 minggu lebih cepat dari perencanaan. Tren grafik perhitungan SV dan SV(t) menghasilkan nilai positif menunjukkan durasi akhir pelaksanaan lebih cepat dari perencanaan, sedangkan tren grafik perhitungan SPI dan SPI(t) menghasilkan >1 menunjukkan durasi akhir pelaksanaan pada minggu kontrol lebih cepat dari perencanaannya. Sehingga Metode Earned Schedule dinilai lebih akurat dalam memberikan penilaian kinerja terhadat estimasi durasi Proyek.
ANALISIS PERENCANAAN SISTEM DRAINASE DALAM UPAYA PENANGGULANGAN BANJIR: Studi Kasus: Perumahan Villa Mutiara Cibitung Ariyani, Dwi; Ahmad Alghazali, Aldi
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5919

Abstract

Banjir kerap terjadi di Perumahan Villa Mutiara Cibitung, yang mana pada tahun 2016 peristiwa banjir terparah pernah terjadi di lokasi ini dengan ketinggian mencapai 80 cm. Banjir tersebut telah menyebabkan kerugian yang signifikan bagi warga yang tinggal di perumahan ini. Adapun penelitian ini bertujuan untuk menganalisis penyebab terjadinya banjir pada lokasi ini dan menemukan solusi untuk mengatasi masalah tersebut. Analisis yang dilakukan berupa Analisa Hidrologi meliputi Uji Konsistensi menggunakan metode RAPS (Rescaled Adjusted Partial Sums), Analisa Curah Hujan dengan menggunakan Metode Distribusi Gumbel, Analisa Intensitas Hujan menggunakan hujan harian rencana atau Metode Mononobe dengan kala ulang 5 tahun, Analisa Debit Banjir Rencana menggunakan Metode Rasional dan Intensitas Hujan yang digunakan sesuai dengan Waktu Konsentrasi. Debit rencana yang didapat dari analisa memiliki nilai yang berbeda disetiap saluran, dimana rentang nilai dari terkecil berada pada Kuarter 34 dengan nilai sebesar 0,1378 m3/detik dan 1,1371 m3/detik pada Sekunder 1. Setelah dilakukan perbandingan antara debit banjir rencana dengan debit saluran didapat 14 saluran drainase yang tidak mampu mengatasi angka Debit Banjir yang tinggi. Maka diperlukan desain baru pada saluran-saluran tersebut dengan merubah tinggi saluran (h) dengan metode trial and error agar mampu menampung debit hujan rancangan, rentang tinggi perubahan saluran pada setiap saluran yang tidak sesuai adalah 0,05 m pada Kuarter 50 hingga 0,30 m pada Sekunder 1. Setelah mendapatkan desain saluran yang baru diharapkan akan dapat menjadi solusi efektif dalam mengatasi permasalahan banjir di Perumahan Villa Mutiara Cibitung.
ANALISIS SISTEM VENTILASI DAN PENGKONDISIAN UDARA PADA KONSEP GREEN BUILDING DI GEDUNG FAKULTAS TEKNIK UNIVERSITAS PANCASILA UNTUK MENINGKATKAN KENYAMANAN Airunnisa Virginia, Nur; Herzanita, Ayu
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5923

Abstract

Kondisi suhu yang panas membuat ruangan tidak nyaman sehingga memanfaatkan air conditioner (AC) namun tentunya hal ini berdampak pada lingkungan antara lain pemanasan global (Global Warming) dan penipisan lapisan ozon. Oleh karena itu pengaruh ini dapat dikurangi semaksimal mungkin dengan menggunakan sumber daya alam yang efisien sehingga tercipta bangunan yang sehat, hemat energi dan ramah lingkungan. Pada bangunan dengan konsep green building, pengkondisian suhu udara agar nyaman dapat dilakukan dengan membuka ruang terbuka, ventilasi, tanaman hijau dan masih banyak lagi yang akan dianalisis dalam penelitian ini. Gedung Fakultas Teknik Universitas Pancasila yang berlokasi di Srengseng Sawah, Jakarta Selatan berdiri sejak 1988. Gedung ini belum temasuk green building yang tersertifikasi, sertifikasi untuk green building di Indonesia dinamakan greenship. Salah satu aspek green building adalah kenyamanan dengan kriteria tata suhu ruangan. Sesuai dengan standar nasional Indonesia suhu 25 - 27° C sebagai setting suhu ruangan. Tujuan dari penelitian ini adalah untuk menganalisis sistem ventilasi dan pengkondisian udara untuk retrofitting green building di gedung Fakultas Teknik Universitas Pancasila. Metode kuantitatif eksplanatif yang dilakukan pada penelitian ini berkaitan dengan tata suhu pada gedung Fakultas Teknik Universitas Pancasila. Variabel yang ditinjau pada penelitian ini adalah sistem ventilasi, sistem pengkondisian udara dan kenyamanan, benchmarking dilakukan pada Universitas Multimedia Nusantara. Berdasarkan variabel tersebur dilakukan pengamatan kondisi eksisting di gedung Fakultas Teknik Universitas Pancasila, diperoleh hasil pada area lobby bersuhu 29,8°, koridor bersuhu 30,1°, ruang kelas bersuhu 28,3°, area tangga bersuhu 29,1°. Untuk memaksimalkan peran ventilasi dan pengkondisian udara pada ruangan, direkomendasikan penggunaan roster, penerapan double skin, pengukuran aliran udara, penggunaan teknologi untuk pengukuran suhu, kelembaban dan penerapan smart room, Untuk penerapan green building di gedung Fakultas Teknik Universitas Pancasila maka diperlukan pengubahsuaian (retrofitting) yaitu salah satu bidang ilmu konstruksi yang mengacu pada metode atau teknik yang digunakan untuk membawa bangunan ke potensi penuh dengan memodifikasi, memulihkan, atau menambahkan komponen atau peralatan baru yang dianggap penting karena tidak tersedia pada saat pembuatan.
KEPUASAN PEJALAN KAKI DALAM MENGGUNAKAN JEMBATAN PENYEBRANGAN ORANG: Studi Kasus Jembatan Penyebrangan di Stasiun Bogor Meutia, Wita; Osly, Prima Jiwa; Dino Wichaksana, Isfan
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5924

Abstract

Jembatan Penyeberangan Orang (JPO) di Stasiun Bogor merpukan jembatan yang menghubungkan antara Stasiun Bogor ke arah Jl. Kapten Muslihat. Pada JPO di Stasiun Bogor terdapat banyak sekali fasilitas dan hambatan pada landasan JPO yang membuat para pengguna JPO teganggu ketika melintasi JPO Stasiun Bogor. Adanya hambatan ini dapat mengurangi keinginan pejalan kaki dalam menggunakan JPO tersebut. Oleh karena itu perlu dianalisis persepsi pengguna JPO agar nantinya adanya beberapa perbaikan di JPO tersebut. Tujuan penelitian ini adalah menganalisis persepsi pejalan kaki terhadap fasilitas penyebrangan tepatnya di JPO Stasiun Bogor serta menilai efektivitas dari penggunaan JPO. Metode penelitian yang digunakan dengan survei lalu lintas pejalan kaki yang menggunakan JPO dan penyebaran kuesioner. Responden dari penelitian ini adalah pejalan kaki yang menggunakan JPO di Stasiun Bogor. Data volume yang diperoleh dianalisis untuk menilai efektivitas penggunaan JPO. Kemudian data persepsi responden diolah dengan menggunakan Index Performance Analysis (IPA) untuk mengetahui variabel yang perlu mendapat perhatian untuk diperbaiki. Hasil kajian memperlihatkan bahwa untuk persentase efektivitas dengan rata rata di atas 80% persen yang berarti JPO ini sangat efektif. Kemudian hasil analisis IPA dari persepsi pengguna memperlihatkan terdapat 5 variabel yang harus di perbaiki yaitu variabel 1 (JPO aman dari aksi kejahatan), 2 (JPO aman dilalui anak-anak), 3 (Landasan JPO tidak licin dan berlubang), 4 (Pegangan anak tangga JPO dalam kondisi baik), dan 16 (Tersedianya fasilitas penyandang disabilitas).
ANALISIS PERBANDINGAN VOLUME DAN BIAYA PADA PEKERJAAN ARSITEKTUR : Studi Kasus Proyek Apartement The Spring Residences Ciputat Agustin, Atika; Plamonia, Nicco; Andreas, Azaria
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5926

Abstract

Pembangunan sebuah proyek diperlukan perencanaan yang baik dengan mempertimbangkan waktu yang efisien, biaya yang efisien dan mutu yang berkualitas sehingga didapat suatu proyek konstruksi yang ekonomis, serta dapat diperhitungkan untuk melakukan sebuah pembangunan proyek agar tidak terjadi adanya perselisihan nilai estimasi yang signifikan dari anggaran yang disusun. Estimator dituntuti mempunyaii keahliani dalam perhitungani volume pekerjaan, penilaiani proyek konstruksi, dan keahliani spesifiki lainnya yang tidak lepas dari bantuan software yang berhubungan dengan perhitungan, pengolahan, dan penyajian data. Tujuan penelitian ini untuk menganalisis perbandingan perhitungan volume dan total biaya pada pekerjaan arsitektur menggunakan Software Autocad dengan Software Planswift dan menganalisis pemilihan metode yang lebih efisien antara Software Autocad atau Software Planswift dari segi waktu,biaya dan user. Metode penelitian dengan melakukan perhitungan quantity pekerjaan pada software autocad dan software planswift pada studi kasus proyek Apartement The Spring Residences Ciputat ini berlokasi di Jl. Otista Raya No.23, Kecamatan Ciputat Kota Tanggerang Selatan, Banten 15311. Proyek ini terdiri dari 24 lantai sedangkan perhitungan sebanyak 10 lantai. Selisih hasil perhitungan volume antara software autocad dan software planswift sebesar 546,21 m2 atau 1,16% untuk pekerjaan dinding dan lantai sebesar 274,61 m2 atau 8,26 %, dan pekerjaan plafond 23,83 m2 atau 0,35%. Total selisih biaya pekerjaan arsitektur sebesar Rp.168.677.357 dimana biaya ini lebih besar software autocad dibandingkan software planswift.
ANALISIS PERBANDINGAN PERCEPATAN PEKERJAAN PROYEK MENGGUNAKAN METODE TIME COST TRADE OFF, PENAMBAHAN SHIFT, DAN FAST TRACK: Studi Kasus Cibinong City Mall Extension Sanjaya, Ario; Dofir, Akhmad
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5927

Abstract

Pertumbuhan pusat perbelanjaan modern merupakan fenomena perdagangan dan jasa yang biasa ditemukan di kota-kota kecil maupun di kota-kota besar di seluruh dunia. Sebuah pusat perbelanjaan modern yang dikenal sebagai "Mall" berkembang di kota-kota di Indonesia. Pada pelaksanaan konstruksi terkadang terjadi keterlambatan, bahkan bisa dikatakan hampir 80% mengalami keterlambatan. Jika proyek mengalami keterlambatan, dapat dipastikan proyek tersebut mengalami keterlambatan dalam penyelesaiannya sehingga dibutuhkan percepatan pelaksanaan proyek. Dengan hal tersebut, maka diperlukan penelitian untuk menganalisis perbandingan terhadap efektivitas biaya anggaran dan waktu pekerjaan proyek menggunakan metode Time Cost Trade Off, penambahan Shift pekerja, dan Fast Track. Dalam studi kasus Cibinong City Mall ini, pengembangan proyek mengalami hambatan di lapangan yang menyebabkan keterlambatan pekerjaan. Dengan membandingkan ketiga metode tersebut dapat membantu manajemen proyek dalam penentuan alternatif yang baik dalam meminimalisir biaya dan waktu penyelesaian proyek, terutama pada situasi di mana pekerjaan kritis selesai secepat mungkin. Hasil durasi waktu percepatan pekerjaan arsitektur hotel menggunakan metode TCTO menghasilkan efisiensi waktu senilai 2.71% dari durasi normal, pada penambahan jam kerja menghasilkan total penambahan biaya 6,677%, sedangkan penambahan tenaga kerja menghasilkan total penambahan biaya 0,12%. Alternatif percepatan dengan metode Shift menghasilkan waktu efisiensi percepatan 18.605%, dengan total penambahan biaya sebesar 1.18%. Alternatif percepatan dengan metode Fast Track menghasilkan efisiensi percepatan 4.264%, dengan overhead senilai 1.852%.
ANALISA KINERJA RUAS JALAN YANG DIPENGARUHI OLEH HAMBATAN SAMPING PADA RUAS JALAN ALTERNATIF CIBUBUR Puspita Andani, Elvina; Tjahjani, A.R. Indra
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5928

Abstract

Kemacetan pada ruas jalan diakibatkan karena adanya hambatan samping, hambatan samping ini sangat mempengaruhi kelancaran arus lalu lintas. Jalan Alternatif Cibubur merupakan jalan utama yang menghubungkan Kota Jakarta Timur, Depok, Bogor, dan Bekasi. Jalan tersebut termasuk kedalam tipe 6/2 D dengan penggunaan samping kanan dan kiri jalan untuk pertokoan dan pusat perbelanjaan. Oleh karena itu, pada jalan tersebut sering terjadi kemacetan atau arus lalu lintas tidak lancar. Penelitian ini bertujuan untuk mengetahui kinerja jalan, kelas hambatan samping, serta solusi yang dapat dilakukan untuk melancarkan arus lalu lintas pada ruas jalan tersebut. Metode analisis yang digunakan pada penelitian ini yaitu menggunakan metode Manual Kapasitas Jalan Indonesia (MKJI) tahun 1997. Berdasarkan analisis perhitungan yang dilakukan maka diperoleh nilai volume lalu lintas maksimum pada segmen 1 sebesar 4402.45 smp/jam, sedangkan untuk segmen 2 sebesar 4397.55 smp/jam. Kemudian diperoleh nilai hambatan samping pada segmen 1 sebesar 1095.9 dengan kelas hambatan samping sangat tinggi, sedangkan untuk segmen 2 sebesar 1092.5 dengan nilai kelas hambatan samping sangat tinggi. Selain itu diperoleh nilai kapasitas pada segmen 1 dan segmen 2 sebesar 4169.88 smp/jam. Berdasarkan hal tersebut maka diperoleh nilai derajat kejenuhan pada segmen 1 sebesar 1.06, sedangkan untuk segmen 2 sebesar 1.05. Sehingga pada Ruas Jalan Alternatif Cibubur memiliki tingkat pelayanan F yang artinya arus yang terhambat, kecepatan rendah, dan volume diatas kapasitas jalan. Berdasarkan hasil perhitungan dan analisis yang dilakukan di wilayah studi, maka direkomendasikan untuk menerapkan solusi kondisi hambatan samping tanpa kendaraan berhenti / parkir, dimana kendaraan tidak boleh berhenti / parkir disepanjang jalur pengamatan.
ANALISIS KERUSAKAN JALAN MENGGUNAKAN METODE INTERNATIONAL ROUGHNESS INDEX : Studi Kasus pada Ruas Jalan Tol Gempol – Pasuruan Jalur A KM 776+000 sampai dengan 810+000 Rafizma Saadah, Syarifah; Hagni Puspito, Imam
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5929

Abstract

Jalan Tol Gempol – Pasuruan yang terhitung 6 tahun lamanya beroperasi yang dimulai pada maret 2017 ini memiliki 2 jalur/arah, memiliki bentang panjang dengan jumlah keseluruhan sepanjang 34,50 kilometer, dengan kilometer awal pada KM 776 + 000, dan kilometer akhir pada KM 810 + 000. Berdasarkan data yang didapatkan dari Balai Besar Pelaksanaan Jalan Nasional Jawa Timur – Bali terdapat 5 jenis kerusakan yaitu, lubang, retak, lubang L1 dan L2, retak melintang, retak memanjang. Dan menggunakan Alat Hawkeye menunjukkan bahwa pada Ruas Jalan Gempol-Pasuruan Jalu A KM 776+000 sampai dengan 810+000 sebesar 82,61% memiliki kondisi baik pada permukaan perkeraannya, memiliki 13,04% kondisi sedang pada permukaan dan memiliki sebesar 4,35% kondisi rusak ringan pada permukaan perkerasannya dan memiliki sebesar 0% kondisi rusak berat pada permukaan perkerasannya. Dengan demikian diperlukan cara lain untuk mendapatkan persentase hasil kerusakan jalan dengan cara perhitungan manual untuk mendapatkan perbandingan, dengan metode International Roughness Index (IRI) sehingga di dapatkan hasil untuk permukaan perkerasan sebesar 78,26 % memiliki kondisi baik pada permukaan perkeraannya, memiliki 17,39 % kondisi sedang pada permukaan dan memiliki sebesar 4,35 % kondisi rusak ringan pada permukaan perkerasannya dan memiliki sebesar 0 % kondisi rusak berat pada permukaan perkerasannya. Dari 2 hasil nilai IRI terdapat perbedaan yang selisihnya sangat kecil sehingga hasil IRI yang didapatkan dengan alat ada kemungkinan terdapat kesalahan karna tidak dilakukan pemeriksaan kalibrasi sedangkan hasil nilai IRI dari perhitungan manual kemungkinan tidak akuratnya disebabkan oleh hasil perhitungan dari nilai roughness yang masih keliru dalam membaca angkanya. Dimana rata-rata nilai kerusakan jalan menunjukan kepada kondisi baik, sehingga hanya di perlukan penangganan seperti pemeliharaan rutin saja.
ANALISIS STABILITAS LERENG DENGAN GEOGRID DAN BRONJONG Dedy Pratama1, Dimas; Trisno Lestari, Rini; Purnama Putra, Paksitya
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5930

Abstract

Lokasi penelitian ini berada Purwakarta dimana lokasi konstruksi peternakan ini berada tepat di tepi lereng tebing. Kondisi stabilitas lereng pada lokasi penelitian ini tidak stabil, hal ini dikarenakan pada saat masa konstruksi tanah dan bangunan tersebut amblas dan terjadi kelongsoran. Berdasarkan hal tersebut perlu dilakukan perkuatan lereng untuk meningkatkan daya dukungnya. Analisis yang pertama dilakukan yaitu dengan mengecek apakah lereng tersebut aman atau tidak dengan menggunakan software berbasis Limit Equilibrium Method (LEM) dimana dihasilkan nilai Safety Factor (SF) sebesar 1,06 yaitu kurang dari 1,5 dari SF rencana. Berdasarkan analisis tersebut diperlukan alternatif metode perkuatan lereng, metode perkuatan lereng yang digunakan pada penelitian ini yaitu dengan alternatif pertama dengan menggunakan material geogrid, alternatif kedua dengan material bronjong dan alternatif ketiga yaitu kombinasi keduanya. Alternatif pertama yaitu perencanaan geogrid dilakukan dengan menghitung kebutuhan yang akan dipasang dimana dihasilkan Tipe geogrid Biaxial Geogrid 200/50 F dengan nilai Ultimate Tensile Strength (MD/CM) sebesar 200/50 kN/m dengan jarak pemasangan 0,5 meter dengan nilai MR komulatif sebesar 2,512.820513 kN/m sebanyak empat lapisan dengan total panjang geogrid yang dibutuhkan sebesar 10,8791 m. Alternatif kedua yaitu dengan material bronjong yang dianalisis dengan software dihasilkan nilai safety factor sebesar 0,20 sehingga kurang aman. Alternatif yang ketiga yaitu dengan menggunakan kombinasi kedua nya dimodelkan dengan software dihasilkan deformasi sebesar 0,07127 meter. Pemilihan analisis perhitungan dari ketiga alternatif tersebut dihasilkan alternatif yang ketiga yaitu dengan kombinasi kedua material geogrid dan bronjong.
EVALUASI DESAIN STRUKTUR DENGAN SNI 1726:2019 DAN SNI 2847:2019 PADA GEDUNG 4 LANTAI Ardian Putra, Bagas; Nur Arini, Resti
Jurnal ARTESIS Vol. 3 No. 2 (2023): JURNAL ARTESIS
Publisher : Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/artesis.v3i2.5931

Abstract

Kota semarang sebagai salah satu kota pelajar di Indonesia terus melakukan pembangunan rumah susun mahasiswa guna mengakomodir fasilitas mahasiswa salah satunya Rusun XYZ Semarang yang dibangun pada tahun 2022 namun perencanaanya pada tahun 2017 sehingga belum menggunakan SNI 1726: 2019 dan SNI 2847: 2019 meskipun pelaksanaan nya tahun 2022. Dalam proses mendapatkan kepastian kelayakan keamanan struktur yang terbangun perlu dilakukan evaluasi menggunakan SNI terbaru. Evaluasi dilakukan guna mendapatkan mengetahui kelayakan struktur akibat gempa, menganalisis dimensi struktur, menganalisis penulangan struktur, serta menganalisis tinjauan perkuatan struktur yang diperlukan akibat penerapan SNI 1726:2019 dan SNI 2847:2019. Metode yang digunakan ialah melakukan re-modelling pada SAP2000 yang bedasarkan gambar kerja yang didapatkan dari konsultan pengawas dan menghitung ulang mengikuti beberapa tinjuan sesuai dengan SNI 1726: 2019 dan SNI 2847: 2019. Hasil yang didapatkan berupa kelayakan struktur terhadap beberapa resiko keruntuhan akibat gempa dan tabel cross check hitungan antara kuat rencana struktur dengan gaya dalam yang terjadi pada proses permodelan menggunakan SAP2000. Dari hasil yang diperoleh masih dalam kondisi struktur kolom, balok serta pelat masih memiliki kelayakannya setelah ditinjau menggunakan SNI 2847:2019, serta pengecekan desain existing masih dalam kategori layak ketahanan gempa yang ditinjau terhadap penskalaan gempa diatas 85%, ketidakberaturan horizontal dan vertikal, simpangan antar lantai dan P-delta. Serta pada review terhadap performance level rumah susun XYZ Semarang dalam kategori kinerja Immediate Occupancy dikarenakan hasil perhitungan yang didapatkan terhadap drift ratio > 1% yaitu tidak ada kerusakan pada komponen struktur, hanya kerusakan minor pada komponen non struktur. Sehingga bangunan masih aman untuk difungsikan.