Analysis Of Early Warning System In Cold Room Vaccine Storage With Iot System Aprilina Gayuh Arniningtyas; Andjar Pudji; Endro Yulianto; Latafat Mikayilzade Ali
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v16i2.487

Abstract

Cold room as a cold room for vaccine storage is an environment with a controlled temperature used to maintain and distribute vaccines in optimal conditions. To maintain the vaccine, it is necessary to pay attention to routine temperature monitoring, temperature data management, and prevention of situations that endanger the vaccine. The results of this review are expected to be a reference for researchers and readers with the development of research using the DS B1820 temperature sensor which will analyze the results of the data logger output and linearity at sensitive locations Cold Room with LCD output and equipped with an IoT system web display on a PC for monitoring and alarm. and notification via telegram when there is a change in temperature approaching and outside the range of 2 - 8 ° C so that this can make it easier for officers to monitor the temperature and quality of the vaccine. In the results of the study, temperature graphs and temperature data can be displayed which are recorded in minutes. Temperature measurement with standard tools produces the largest difference of 0.83. The lowest temperature was 2.06℃ and the highest temperature was 8.31℃ as well as telegram notification of early warning (2.58℃), evacuation vaccine (2.31℃), and exposed vaccine (8.6℃).
The Sensor Occlusion SEN0257 on the Infusion Device Analyzer 2 Channel with TFT Display ensures high accuracy in detecting occlusions. Ach Jiddan Asrori'; Endro Yulianto; Triana Rahmawati
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 3 (2023): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i3.300

Abstract

Syringepump and Infuspump function to provide drugs or fluids that are carried out directly and continuously for a certain period of time through a blood vessel. Often encountered problems of blockage or occlusion in the use of infusion pumps and syringe pumps. Occlusion in the infusion device causes the incoming drug fluid to not flow constantly. Occlusion limit set at 20 Psi according to ECRI. To ensure this, proper calibration is required at least once a year. The purpose of this research is to analyze the accuracy of the pressure sensor on the Occlusion measurement on the Infusion Device Analyzer 2 Channel showing TFT. This study has 2 channels so that it can calibrate 2 tools simultaneously. The design of this module uses a Water Pressure Sensor to measure occlusion and a solenoid valve for pressure simulation. When the sensor is depressed, the sensor detects the pressure and is processed by the Arduino. The pressure results are then displayed on a 7-inch TFT LCD in the form of graphs and numbers in real time and stored on the SD card.
Design and Development of Flow Analyzer for Peak Inspiratory Flow (PIF) and Peak Expiratory Flow (PEF) Parameters. Andri Lazuardi Wahyu Pambudi; Endro Yulianto; Levana Forra Wakidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 3 (2023): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i3.313

Abstract

The PIF and PEF parameters on the ventilator need to be taken into account to monitor the condition of patients undergoing mechanical ventilation. Both of these parameters need to undergo periodic testing to ensure that the ventilator can provide accurate information to its users. The testing of these two parameters can be conducted using a flow analyzer. The objective of this research is to develop a flow analyzer for PIF and PEF parameters using the AFM3000 flow sensor, with the results displayed on an LCD TFT screen in the form of graphs and numerical values. The research measurements were conducted in Volume Control (VC) mode with VT settings of 200, 300, 400, 500, and 600 mL. Data collection was done using two methods to obtain two different types of data. From the first data collection, the largest errors in reading PIF and PEF values were found to be 3.49% and 2.99%, respectively. The second data collection resulted in a sensor's change in reading constant flow of ±0.1 LPM. Overall, the research findings indicate that the AFM3000 sensor has good accuracy and stability. Additionally, the AFM3000 flow sensor has good sensitivity and very short delay, making it suitable for real-time graph display in the module.
A Assistance of Health Personnel in The Implementation of Calibration Results in Public Hospitals Dr. Iskak Tulungagung: Assistance of Health Personnel in The Implementation of Calibration Results in Public Hospitals Dr. Iskak Tulungagung Anita Miftahul Maghfiroh; Endro Yulianto; Syaifudin
Frontiers in Community Service and Empowerment Vol. 2 No. 3 (2023): September
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v2i3.46

Abstract

Optimal quality of health services depends on the accuracy of medical devices. In an effort to improve quality standards, Dr. General Hospital Iskak Tulungagung implements a program to assist health workers in understanding and applying the results of medical device calibration. This research aims to increase health workers' knowledge about calibration, strengthen patient confidence, and improve the accuracy of diagnosis and treatment. This research contributes to improving the competency of health workers and increasing patient satisfaction through assistance in implementing calibration results. This contribution is important in building public trust in health services. The mentoring program involves regular counseling, practical workshops, skills training, as well as individual mentoring by a team of calibration experts. A feedback system is also implemented for continuous evaluation and improvement. This research shows a significant increase in health workers' understanding of medical device calibration. Patients report higher levels of satisfaction with services provided by healthcare professionals who use calibrated devices. This mentoring program was successful in increasing health workers' understanding of calibration, building patient trust, and increasing the accuracy of diagnosis and treatment. This success indicates the importance of assistance in the context of implementing calibration results in hospitals. The results of this research have positive implications for improving health service quality standards. These implications extend to the health education sector and clinical practice, strengthening evidence-based practice and increasing public trust in the health system. Thus, the mentoring program becomes a viable model for improving the quality of health services in hospitals and other health institutions
Wheelchair safety system using fuzzy logic controller to avoid obstruction Yulianto, Endro; Salwa, Umaimah Mitsalia Ummi; Triwiyanto, Triwiyanto; Indarto, Tri Bowo
International Journal of Electrical and Computer Engineering (IJECE) Vol 14, No 6: December 2024
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v14i6.pp7001-7012

Abstract

A wheelchair is the primary means of mobility for individuals unable to walk. This study aimed to develop a safety system for electric wheelchairs to help people with tetraplegia avoid obstructions. The main contribution of this study is the implementation of a sensor with a wider reflection angle and the adjustment of the wheelchair's speed based on the distance to the obstruction, eliminating the need for manual speed selection. The safety system utilizes LV-MaxSonarEZ1 ultrasonic sensors, which function as reflectance distance readers placed on the front, rear, right, and left sides of the wheelchair. The output from the sensors is input into an Arduino, which functions as the controller. The safety system employs adaptive speed control based on distance through a fuzzy logic controller. The wheelchair was tested with obstruction distances of 1, 1.8, 3, and 10 m. The wheelchair could stop at a distance of 34.06 cm for forward movement and 45.16 cm for reverse movement. The results of this study successfully demonstrate the creation of a safety system on a wheelchair using ultrasonic sensors to avoid obstructions and detect areas, with more adaptive speed control based on distance through a fuzzy logic controller.
Entrepreneur Approach: Implementation of Telemedicine System for Early Detection of Stunting in Wonoayu Village, Sidoarjo Maghfiroh, Anita Miftahul; Endro Yulianto; Syaifudin
Frontiers in Community Service and Empowerment Vol. 4 No. 1 (2025): March
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v4i1.79

Abstract

Stunting is a serious health problem in Indonesia, especially in rural areas with limited access to health services. Wonoayu Village, Sidoarjo, is one of the areas that still faces challenges in early detection of stunting in children under five. To overcome this problem, the Partner Village Development Program (PPDM) was implemented with the aim of utilizing telemedicine technology through the Pelita application. This application is designed to help Posyandu cadres detect the risk of stunting quickly and accurately, as well as provide more effective health monitoring services. The main contributions of this program include developing the Pelita application, outreach to the community and health workers, providing tablet assistance to support application operations, as well as implementing the application in Posyandu activities. The results of this program show an increase in the capacity of Posyandu cadres in monitoring children's health, easy access to accurate health data, and faster and more efficient early detection of stunting. In conclusion, the implementation of the telemedicine system through the Pelita application has had a positive impact in overcoming the stunting problem in Wonoayu Village. This application facilitates structured monitoring of children's health, enabling early intervention for children at risk of stunting. The implication of this program is the need for continuous maintenance and development so that the application can continue to be used optimally and become a model for other regions in efforts to reduce stunting rates in Indonesia.
STATUS GIZI DAN KADAR GLUKOSA DARAH LANSIA DI POSYANDU ABIYOSO POLKESBAYA Juliana Christyaningsih; Luthfi Rusyadi; Imam Sarwo; Ferry Kriswandana; Sri Utami; I Dewa Gede Hari Wisana; Edy Haryanto; Minarti; Hilmi Yumni; Dwi Wahyu Wulan Sulistyowati; Irwan Sulistio; Taufiqurrahman; Isnanto; Endro Yulianto; Retno Sasongko Wati; Fitri Rokhmalia; Siti Mar'atus; Slamet Wardoyo; Liliek Soetjiatie; Yuni Ginarsih; Ira Rahayu Tiyar Sari; Ira Puspitasari
Jurnal Ilmiah Tatengkorang Vol 8 No 2 (2024): Jurnal Ilmiah Tatengkorang
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat, Politeknik Negeri Nusa Utara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54484/tkrg.v8i2.609

Abstract

Currently, the percentage of the elderly population in Indonesia has increased much higher than in previous years. As people age, their immune system decreases and they are more likely to be affected by diabetes mellitus. In Indonesia, diabetes mellitus currently ranks as the third most prevalent cause of mortality following cardiovascular disease. Diabetes mellitus is closely associated with blood glucose levels. People with high blood glucose levels have a tendency to be overweight or obese. The increasing prevalence of diabetes mellitus in the elderly, it will have an impact on hampering the development of the country. To improve the quality and life expectancy in the elderly, preventive measures are needed to increase excess glucose levels in the body. From these problems, community service activities were conducted in the form of health checks on nutritional status and blood glucose in elderly participants. The activity took place at the Abiyoso Integrated service post Polkesbaya on May 3, 2023. From the results of the examination, it was found that most of the elderly participants who participated in the activity had excess nutritional status but had normal blood glucose in the body. From this it can be concluded that high blood glucose levels in the body are not always determined by a person's nutritional status, but also lifestyle, and diet. Saat ini, presentase penduduk lanjut usia di Indonesia telah meningkat jauh lebih tinggi dari tahun-tahun sebelumnya. Seiring bertambahnya usia pada seseorang, daya tahan tubuh manusia akan semakin menurun dan cenderung menderita diabetes melitus. Di Indonesia, penyakit diabetes melitus menempati posisi ketiga sebagai pemicu kematian tertinggi setelah penyakit kardiovaskular. Penyakit diabetes melitus memiliki kaitan erat dengan kadar glukosa dalam darah. Seseorang yang memiliki kadar glukosa dara tinggi cenderung memiliki berat badan berlebih atau obesitas. Dengan semakin meningkatnya prevalensi penderita diabetes melitus pada masa lansia, akan mengakibatkan dampak terhambatnya pembangunan negara. Untuk meningkatkan kualitas dan harapan hidup pada masa lansia diperlukan tindakan pencegahan kenaikan kadar glukosa berlebih dalam tubuh. Dari permasalahan tersebut dilakukan kegiatan pengabdian masyarakat dalam bentuk pemeriksaan kesehatan status gizi dan glukosa darah pada peserta lansia. Kegiatan berlangsung di posyandu Abiyoso Polkesbaya pada tanggal 3 Mei 2023. Berdasarkan hasil pemeriksaan didapatkan bahwa sebagian besar peserta lansia yang mengikuti kegiatan memiliki status gizi berlebih tetapi memiliki glukosa darah yang normal dalam tubuh. Dari hal ini dapat disimpulkan tingginya kadar glukosa darah dalam tubuh tidak selalu ditentukan dari status gizi seseorang, melainkan juga gaya hidup, dan pola makan
Analysis Of Early Warning System In Cold Room Vaccine Storage With Iot System Arniningtyas, Aprilina Gayuh; Pudji, Andjar; Yulianto, Endro; Ali, Latafat Mikayilzade
Jurnal Teknokes Vol. 16 No. 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Cold room as a cold room for vaccine storage is an environment with a controlled temperature used to maintainand distribute vaccines in optimal conditions. The results of this review are expected to be a reference for researchers andreaders with the development of research using the DS B1820 temperature sensor which will analyze the results of the datalogger output and linearity at sensitive locations Cold Room with LCD output and equipped with an IoT system web displayon a PC for monitoring and alarm and notification via telegram when there is a change in temperature approaching and outsidethe range of 2 - 8 ° C so that this can make it easier for officers to monitor the temperature and quality of the vaccine. In theresults of the study, temperature graphs and temperature data can be displayed which are recorded in minutes. Temperature measurement with standard tools produces the largest difference of 0.83. The lowest temperature was 2.06°C and the highest temperature was 8.31°C as well as telegram notification of early warning (2.58°C), evacuation vaccine (2.31°C), and exposed vaccine (8.6°C). With this research a Warning System was obtained which was achieved with telegram notifications namely early warning, evacuation vaccines and exposed vaccines to maintain vaccine quality.
Exploration of Biomechanical and Biooptical Sensors on Cardiac Monitor on Carotid Pulse Putra, Wahyu Ramadhan; Yulianto, Endro; Faizal, Ajesh
Jurnal Teknokes Vol. 17 No. 3 (2024): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Cardiovascular diseases are a significant global health concern, often requiring timely and accurate monitoring for effective management. Traditional heart monitoring devices face limitations, such as inadequate real-time data and suboptimal accuracy. This study aims to enhance the detection of carotid pulse signals by comparing the performance of two sensor types: piezoelectric sensors and SEN0203 sensors. The methodology involved designing a cardiac monitoring device that integrates both sensors to simultaneously capture carotid pulse and phonocardiograph (PCG) signals. Data collection was conducted on 10 respondents, where both sensors were applied alternately to the carotid artery, and the signals were analyzed using an oscilloscope. The results demonstrated that the piezoelectric sensor outperformed the SEN0203 sensor in terms of signal clarity and amplitude. Specifically, the average amplitude of the carotid pulse recorded by the piezoelectric sensor was 5.3 mV, while the SEN0203 sensor recorded an average amplitudeof only 3.2 mV. Additionally, the correlation analysis revealed a strong relationship between the carotid pulse and PCGsignals, with a correlation coefficient of 0.87, indicating a high degree of reliability in the measurements obtained fromthe piezoelectric sensor. In conclusion, the findings of this study suggest that piezoelectric sensors are more effectivefor monitoring carotid pulse signals compared to SEN0203 sensors, providing clearer and more reliable data. Thisadvancement in sensor technology has the potential to improve early detection of cardiovascular abnormalities, leadingto better patient outcomes. Future research should focus on the development of portable monitoring devices thatincorporate these sensors, facilitating widespread clinical application and enhancing the overall quality of cardiovascularcare.
Growth Monitoring System Using Infant Length to Determine Nutritional Status in Children Aged 0-12 Months. Yulia Ningrum, Churie Nurhaeni; Yulianto, Endro; Rahmawati, Triana
Jurnal Teknokes Vol. 17 No. 3 (2024): September
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research addresses the pressing issue of monitoring the growth and nutritional status of infants aged 0-12months, a critical period for health and development. Inadequate growth monitoring can lead to undetected nutritionaldeficiencies and long-term health consequences. To tackle this problem, the study developed an innovative Growth MonitoringSystem that utilizes length, weight, and head circumference as key indicators of nutritional status. The system integratesadvanced technology, including an ESP-32 microcontroller, load cell sensors for weight measurement, ultrasonic sensors forheight measurement, and infrared sensors for head circumference measurement. The methodology involved collecting datafrom 30 respondents, where the system automatically recorded measurements and generated growth curves displayed on aweb-based platform. The accuracy of the measurements was evaluated, revealing significant variability in error rates.Specifically, the highest error in head circumference measurement was recorded at 25.38%, while the weight measurementexhibited a lower error rate of -20.47%. These results highlight the challenges in achieving precise measurements but alsodemonstrate the system's capability to provide essential data for assessing infant growth. In conclusion, the developed GrowthMonitoring System represents a significant advancement in child health monitoring, offering a reliable and efficient methodfor tracking the growth of infants. Despite the observed measurement errors, the system's automated data collection andanalysis capabilities provide valuable insights into nutritional status. The research emphasizes the potential for broaderimplementation of such systems in pediatric clinics and national health programs, ultimately contributing to improved healthoutcomes for infants. By enhancing the accuracy and accessibility of growth monitoring, this research paves the way for moreeffective interventions in early childhood nutrition and health.
Co-Authors ., Sumber Abd Kholiq Abhishek Mishra Ach Jiddan Asrori' Achmad Rizal Adhi Susanto Ahmad Kamil Solihin Ali, Latafat Mikayilzade Andjar Pudji Andri Lazuardi Wahyu Pambudi Anggraeni Dara Pratiwi Anita Miftahul Maghfiroh Aprilina Gayuh Arniningtyas Arifah Putri Caesaria Arniningtyas, Aprilina Gayuh Ashish Bhatt Bahaa Eddine ELBAGHAZAOUI Bambang Guruh Irianto Caesar Febri Nugroho Dimas Adi tya Dwi Herry Andayani Edy Haryanto Fadilla Putri Devito Nur Azizah Fahmi Ardhi Faizal, Ajesh Ferry Kriswandana Ginarsih, Yuni Her Gumiwang Ariswati Herlina Candra Putri Hilmi Yumni I Dewa Gede Hari Wisana Imam Sarwo Indarto, Tri Bowo Ira Puspitasari Irwan Sulistio Isnanto Juliana Christyaningsih K. K. Mujeeb Rahman Kholiq, Abd Lamidi Lamidi Latafat Mikayilzade Ali Levana Forra Wakidi Liliek Soetjiatie Luthfi Rusyadi Luthfiyah, Sari Luthfiyah, Sari Maduka Nosike MINARTI Moh. Amin Nasrullah Muhammad Fauzi Muhammad Iqbal Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Nadiya Garnis Sallyfan Nur Fildzah Hidayati Priyambada Cahya Nugraha Priyambada Cahya Nugraha Pudji, Andjar Putra, Wahyu Ramadhan Raden Duta Ikrar Abadi Rahmawati, Triana Ramadhan, Bahrurrizki Retno Sasongko Wati Rifky Maulana Fuadi Rokhmalia, Fitri Salwa, Umaimah Mitsalia Ummi Sambhrant Srivastava Samekto Wibowo Sandeep Kumar Gupta Sari Luthfiyah Sari, Ira Rahayu Tiyar Sella Octa Ardila Siti Mar'atus Slamet Wardoyo SRI UTAMI Sulistyowati, Dwi Wahyu Wulan sumber sumber Syaifudin Syaifudin Taufiqurrahman Thomas Sri Widodo Torib Hamzah Tri Bowo Indrato Triana Rahmawati Triana Rahmawati Triwiyanto Triwiyanto Vishwajeet Shankhwar Vugar Abdullayev Wahyu Caesarendra Wahyu Pratama Yulia Ningrum, Churie Nurhaeni