Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Journal of Renewable Energy, Electrical, and Computer Engineering

Economic Dispatch Analysis Using Equal Incremental Cost Method with Linear Regression Approach Hasibuan, Arnawan; Kurniawan, Robi; Isa, Muzamir; Mursalin, Mursalin
Journal of Renewable Energy, Electrical, and Computer Engineering Vol 1, No 1 (2021): March 2021
Publisher : Institute for Research and Community Service, Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i1.3617

Abstract

The use of fuel is one thing that needs special attention, because most of the operating costs of a plant are fuel costs. One of the efforts to minimize the cost of generating fuel is called Economic dispatch. In this study, an Equal Incremental Cost method with a Linear Regression approach will be presented to obtain a minimum generation cost. The case taken is the Pangkalan Susu PLTU which operates two generating units. Based on the results of calculations using the Equal Incremental Cost method with the Linear Regression approach, the cost is -0.033% or an average of -13,111 $/hour.
The Effect of Distributed Generator Injection with Different Numbers of Units on Power Quality in the Electric Power System Kurniawan, Robi; Nasution, Ardiansyah; Hasibuan, Arnawan; Isa, Muzamir; Gard, Muskan; Bhunte, Shrikant Vasantrao
Journal of Renewable Energy, Electrical, and Computer Engineering Vol 1, No 2 (2021): September 2021
Publisher : Institute for Research and Community Service, Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i2.5236

Abstract

Distributed Generation (DG) is a small capacity generator located in the electricity distribution system and is usually placed on buses that are connected directly to the load. Placement of distributed generation is one of the technical efforts to reduce voltage drop and power losses in the system. In addition, load flow analysis is a study to plan and determine the amount of power in an electric power system. The results of power losses after adding distributed generation were the best in the fifth experiment on bus 149, where the system experienced a total loss of active power (P) previously of 720,822 kW, to 682,939 kW and total loss of reactive power (Q) previously of 530.02 kVar, to 405.835 kVar. From the results of the calculation of the power flow using ETAP software (Electrical Transient Analyzer Program). So, it can be concluded that the electrical network system can be said to be good. The results obtained are the more DG (wind turbine generator) that is input into the bus it will reduce the voltage drop that occurs. After simulating the overall voltage drop, it still meets the standards according to the results of the Text Report on ETAP.