PERBAIKAN JALAN LINGKUNGAN PERUMAHAN MENGGUNAKAN PERVIOUS CONCRETE BANJAR WIJAYA RW 07 KELURAHAN CIPETE, KECAMATAN PINANG, KOTA TANGERANG Kushartomo, Widodo; Owen, Frigion; Kurniawan, Rivaldo; Saputra, Stenley Jordan
Jurnal Bakti Masyarakat Indonesia Vol. 7 No. 1 (2024): Jurnal Bakti Masyarakat Indonesia
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jbmi.v7i1.31802

Abstract

Pervious concrete is highly porous concrete used for work applications that allows water from rainfall and other sources to pass through easily. The use of permeable concrete can reduce water runoff and can replenish groundwater levels. Pervious concrete is traditionally used in parking areas, low-traffic areas, walkways and greenhouses and contributes to sustainable construction.  PkM collaboration partners are in the RW 07 Cipete Village, Pinang District, Tangerang City, with problems faced in the form of damage to environmental roads. The community asked for help in overcoming this problem, so the PkM TEAM from Tarumanagara University offered a solution using pervious concrete to overcome the problem of damaged roads.  In the PkM carried out, the Pervious concrete offered was the result of research at the UNTAR Concrete Technology laboratory using a cement to water ratio of 0.3 gravel using 19-10 sized gravel with a ratio of 1.3 : 0.9, without using sand, and using a superplasticizer 0.5% of cement weight. The resulting pervious concrete has a cavity volume ranging from 18% - 35% with a compressive strength of 20 MPa. Mixing of materials at the PKM location is carried out using a molen truck with a volume of 7.5 m3. The area of ​​the repaired road measures 6 m x 24 m with a thickness of 0.06 m. The results of PkM's work show that Pervious Concrete was successfully used to repair potholes in Banjar Wijaya Housing RW 07, Cipete Village, Pinang District, Tangerang City. ABSTRAK Beton tembus air adalah beton berpori tinggi yang digunakan untuk aplikasi pekerjaan yang memungkinkan air dari curah hujan dan sumber lain dapat melewatinya dengan mudah. Penggunaan beton tembus air dapat mengurangi limpasan air dan dapat mengisi kembali permukaan air tanah. Beton tembus air secara tradisional digunakan di area parkir, area dengan lalu lintas rendah, jalur pejalan kaki, dan rumah kaca serta berkontribusi terhadap konstruksi berkelanjutan.  Mitra kerjasama PkM ada di wilayah RW 07 Kelurahan Cipete Kecamatan Pinang Kota tangerang dengan permasalah yang dihadapi berupa kerusakan jalan lingkungan. Masyarakat memerlukan bantuan dalam mengatasi persoalan tersebut sehingga TIM PkM dari Universitas Tarumanagara menawarkan solusi penggunaan pervious concrete atau beton tembus air guna mengatasi persoalan jalan yang rusak tersebut.  Pada PkM yang dilakukan, Pervious concrete yang ditawarkan merupakan hasil penelitian di laboratorium Teknologi Beton UNTAR menggunakan  perbandingan semen terhadap air sebesar 0,3 kerikil menggunakan kerikil berukuran 19-10 dengan perbandingan 1,3 : 0,9, tanpa menggunakan pasir, dan menggunakan superplasticizer  0,5% terhadap berat semen. Pervious concrete yang dihasilkan memiliki volume rongga berkisar antara 18% - 35% dengan kuat tekan 20 MPa. Pencampuran material di lokasi PKM dilakukan menggunakan truk molen dengan volume 7,5 m3. Luas jalan yang diperbaiki berukuran 6 m x 24 m dengan tebal 0,06 m. Hasil kerja PkM menunjukkan Beton Pervious berhasil digunakan untuk pengecoran perbaikan jalan berlubang di Perumahan Banjar Wijaya RW 07 Kelurahan Cipete, Kecamatan Pinang, Kota Tangerang.
PENGARUH UKURAN BENDA UJI KUBUS TERHADAP NILAI KUAT TEKAN RECATIVE POWDER CONCRETE Kushartomo, Widodo; Sutandi, Arianti; Wijaya, Jevin
JMTS: Jurnal Mitra Teknik Sipil Volume 7, Nomor 4, November 2024
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v7i4.32035

Abstract

The testing of reactive powder concrete (RPC) in the laboratory aims to obtain compressive strength values that represent the quality of the concrete being tested. This testing must adhere to established standards, including international regulations such as ASTM (American Standard for Testing Materials), BS (British Standard), and national regulations like SNI. According to BS 1881 Part 108, the concrete samples must be cube-shaped with dimensions of 15 cm x 15 cm x 15 cm. For high-strength concrete such as RPC, it is impractical to use cylindrical specimens with a diameter of 15 cm and a height of 30 cm due to the maximum capacity of the compression testing machine. This study investigates the correlation between compressive strength for cube specimens of 5x5x5 cm³, 10x10x10 cm³, and 15x15x15 cm³. The target compressive strengths are set at K400, K500, and K650, with 10 samples produced for each size and strength class. Compressive strength tests were conducted at 28 days, with the samples cured through immersion in water at 25°C for 26 days. The results indicate that specimen size influences compressive strength values, with smaller specimens exhibiting higher compressive strengths. Conversely, larger specimens are more prone to defects, which may reduce the compressive strength. Abstrak Pengujian RPC di laboratorium bertujuan untuk mendapatkan nilai kuat tekan yang mewakili mutu dari beton yang diujikan. Pengujian harus mengikuti standar-standar yang telah ditentukan seperti bentuk dan ukuran yang  sesuai dengan peraturan internasional seperti ASTM (American Standart for Testing Materials), BS (British Standard), dan peraturan nasional yaitu SNI. Berdasarkan BS 1881 part 108 tentang sampel beton berbentuk kubus, mensyaratkan ukuran benda uji 15 cm x 15 cm x 15 cm. Pada beton dengan mutu sangat tinggi seperti RPC, tidak memungkinkan membuat benda uji silinder berukuran diameter 15 cm tinggi 30 cm, ini berkaitan dengan kapasitas maksimum mesin yang digunakan untuk melakukan pengujian tekan. Pada penelitian ini dicari korelasi kuat tekan ukuran kubus  5x5x5 cm3, 10x10x10 cm3 terhadap 15x15x15 cm3. Kuat tekan beton yang direncanakan K400, K500 dan K650, masing masing ukuran dan mutu benda uji dibuat sebanyak 10 buah. Pengujian benda uji kubus dilakukan pada umur 28 hari, pemeliharan dengan teknik perendaman dalam air bertemperatur 25oC selama 26 hari. Berdasarkan pengujian yang dilakukan ukuran benda uji mempengaruhi nilai kuat tekan, semakin kecil ukuran benda uji maka nilai kuat tekan yang ditunjukkan juga semakin besar. Semakin besar benda uji kubs yang digunakan, kemungkinan terjadinya cacat juga semakin besar.
PENGARUH PENGGUNAAN PALM OIL FUEL ASH SEBAGAI SUBSTITUSI SILICA FUME PADA REACTIVE POWDER CONCRETE Kushartomo, Widodo; Saputra, Stanley Jourdan
JMTS: Jurnal Mitra Teknik Sipil Volume 8, Nomor 2, Mei 2025
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v8i2.33128

Abstract

Concrete is an essential component in building and infrastructure construction, used for both structural and non-structural purposes. The innovation of using palm oil fuel ash (POFA) in reactive powder concrete (RPC) is expected to enhance the compressive and flexural strength of RPC as well as its workability. This research includes five types of RPC mixtures: 100% silica fume & 0% POFA, 75% silica fume & 25% POFA, 50% silica fume & 50% POFA, 25% silica fume & 75% POFA, and 0% silica fume & 100% POFA. The POFA used is pre-burned at 1000°C and sieved using a no.200 sieve. The tests conducted in this study include compressive strength tests, flexural strength tests, and slump tests. The results indicate that the use of POFA leads to a decrease in the compressive strength of RPC by 56.93% and flexural strength by 34.8%, while the workability increases with the higher amount of POFA in the RPC mixture. Abstrak Beton adalah komponen penting dalam konstruksi bangunan dan infrastruktur, digunakan baik untuk keperluan struktural maupun non-struktural. Inovasi penggunaan palm oil fuel ash (POFA) pada reactive powder concrete (RPC) diharapkan dapat meningkatkan kuat tekan dan kuat lentur pada RPC serta meningkatkan workabilitasnya. Pada penelitian ini terdapat 5 jenis campuran RPC yaitu 100% silica fume & 0% POFA, 75% silica fume & 25% POFA, 50% silica fume & 50% POFA, 25% silica fume & 75% POFA, dan 0% silica fume & 100% POFA. POFA yang akan digunakan dibakar terlebih dahulu pada suhu 1000°C dan disaring menggunakan saringan no.200. Pengujian yang dilakukan pada penelitian ini meliputi pengujian kuat tekan, pengujian kuat lentur, dan slump test. Hasil pengujian yang sudah dilakukan menunjukkan bahwa penggunaan POFA mengakibatkan penurunan kekuatan tekan RPC sebesar 56,93% dan lentur RPC sebesar 34,8%, sedangkan pada workabilitas terjadi peningkatan seiring bertambahnya POFA yang digunakan dalam campuran RPC.
Pembatasan dalam Pemanfaatan Air Hasil Daur Ulang IPAL pada Universitas Kurniawan, Vittorio; Kushartomo, Widodo; Kevin
Jurnal Rekayasa Konstruksi Mekanika Sipil Vol 6 No 2 (2023): Volume 6 Nomor 2 Tahun 2023
Publisher : Fakultas Teknik Universitas Katolik Santo Thomas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54367/jrkms.v6i2.2938

Abstract

Suatu bangunan memerlukan air setiap hari untuk memenuhi kebutuhan penghuninya. Di tengah masalah kekurangan air, salah satu solusi yang ada adalah pemanfaatan air yang didaur ulang oleh instalasi pengolahan air limbah (IPAL). Artikel ini mempelajari seberapa optimal air olahan IPAL dapat digunakan untuk memenuhi kebutuhan air sehari-hari pada suatu universitas. Penelitian dilakukan di suatu universitas di DKI Jakarta, Indonesia. Data yang dipakai adalah ketersediaan air dari IPAL dan kebutuhan air total dari PDAM. Data kebutuhan air dipecah berdasarkan tipe penggunaan yaitu untuk penghuni (toilet dan non-toilet), penyiraman tanaman, kebersihan bangunan, dan kolam. Hasil penyelidikan memperkirakan, bila air daur ulang IPAL akan dimanfaatkan, hanya 28,20 % yang bisa dipakai sedangkanya sisa 71,80 % harus dibuang. Ini tidak ideal karena sebaiknya air daur ulang mampu dimanfaatkan semaksimal mungkin untuk mengurangi pemakaian sumber daya air yang makin terbatas. Ada berbagai faktor penyebab yaitu persepsi publik yang buruk mengenai air daur ulang IPAL, mutu air yang tidak memenuhi persyaratan, dan jaringan pipa eksisting yang mencampur sistem pembilasan toilet dengan air bersih lainnya.
PENGARUH PENAMBAHAN SERAT BARCHIP 48 DALAM PENGUJIAN KUAT TARIK LENTUR DAN KUAT TEKAN BETON Suryana, Laurensius Evan; Kushartomo, Widodo
JMTS: Jurnal Mitra Teknik Sipil Volume 8, Nomor 3, Agustus 2025
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v8i3.34136

Abstract

Concrete has high compressive strength, but is weak against tensile or flexural forces. Therefore, concrete is often reinforced with additional materials such as steel reinforcement or fiber to increase its flexural strength. In this study, concrete was added with polypropylene fiber in the form of BarChip with a length of 48 mm and a diameter of 0.3 mm in an effort to increase its flexural strength. Variations of BarChip fiber added 2%, 5%, and 7% of the weight of the concrete, the test object was made in the form of a block measuring 400 mm x 100 mm x 100 mm as a flexural test object and a cylinder measuring 100 mm x 200 mm as a compression test object, the maintenance technique used the immersion method with a temperature of 20ºC, the test was carried out at the age of 28 days. The test results showed that the addition of 4 kg of BarChip fiber per m3 could increase the flexural strength by 48.8%. The more BarChip fiber added, the lower the workability of the mixture. The flexural strength results obtained were 4.1 MPa, 4.6 MPa, 5.3 MPa, and 6.1 MPa, while the compressive strengths obtained respectively were 22.1 MPa, 21.6 MPa, 18.4 MPa, and 16.7 MPa. Abstrak Beton memiliki kekuatan tekan yang tinggi, tetapi lemah terhadap gaya tarik atau lentur. Oleh karena itu, beton sering diperkuat dengan bahan tambahan seperti tulangan baja atau serat untuk meningkatkan kekuatan lenturnya. Pada penelitian ini beton di tambahkan bahan berupa serat polypropilena berbentuk BarChip dengan panjang 48 mm dan diameter 0,3 mm dalam upaya menaikan kuat lentur nya. Variasi serat BarChip yang di tambahkan 2%, 5%, dan 7% dari berat betonya, benda uji di buat dalam bentuk balok berukuran 400 mm x 100 mm x 100 mm sebagai benda uji lentur dan silinder berukuran 100 mm x 200 mm sebagai benda uji tekan, teknik pemeliharaan menggunakan metode perendaman dengan temperatru 20ºC, pengujian di lakukan pada umur 28 hari. Hasil pengujian menunjukan penambahan serat BarChip sebanyak 4 kg per m3 dapat meningkatkan kuat lentur sebesar 48,8 %. Semakin banyak serat BarChip yang di tambahkan maka akan menurunkan workabilitas adukan. Secara berturut turut hasil kuat lentur nya yang di dapat adalah 4,1 MPa, 4,6 MPa, 5,3 MPa, dan 6,1 MPa, sedangkan kuat tekan yang di dapat secara berturut adalah 22,1 MPa, 21,6 MPa, 18,4 MPa, dan 16,7 MPa.
Dampak Penambahan Fly Ash Pada Campuran Beton Terhadap Kuat Tekan dan Durabilitas Beton Akibat Serangan Sulfat Kushartomo, Widodo; Wildan, Vanessa Adistya; Prabowo, Andy
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 31, Nomor 1, JULI 2025
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/mkts.v31i1.71566

Abstract

Concrete is the primary choice for construction projects, including its use in aggressive environments such as coastal areas. The high sulfate content in these environments poses a threat to the durability and compressive strength of concrete. The impact of sulfate attack on concrete can result in degradation and a decrease in concrete quality. Several methods have been used to maintain the durability of concrete, such as applying coatings to the surface of the concrete or using pozzolanic materials in the concrete mixture. In this study, Fly Ash was used as a pozzolanic material to reduce the impact of sulfate attack on concrete. The experiment involved adding Fly Ash to the concrete mixture in proportions of 0%, 10%, 20%, 30%, 40%, and 50% by weight of cement. Three test specimens were made for each variation in diameter and height of 10 cm and 20 cm, respectively. The durability test of the concrete used a magnesium sulfate (MgSO4) solution with a dry-wet cycle method according to SNI 3407-2008, which was conducted after curing in water for 28 days. The results of the test showed that adding Fly Ash to the concrete mixture has been proven to reduce damage and minimize the degradation of concrete quality due to sulfate attack compared to normal concrete without the use of Fly Ash. The use of Fly Ash also increased the compressive strength of all test specimens compared to normal concrete without Fly Ash.
ANALISIS PENGGUNAAN ABU CANGKANG SAWIT TERHADAP SIFAT MEKANIS BETON NORMAL Christian, Marco; Kushartomo, Widodo
JMTS: Jurnal Mitra Teknik Sipil Volume 7, Nomor 1, Februari 2024
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v7i1.24906

Abstract

Concrete is one of the most important materials used in building structures. A material that can be used to create normal concrete with this method is to add palm shell ash to the concrete mix. Palm shell ash can be used as a filler material, because the ash has a chemical composition contains silica (SiO2) which is amorphus and highly reactive at room temperature. The use of palm shell ash as an additive to the concrete mixture aims to improve the quality of the concrete which is planned after palm shell ash is added to the concrete mixture. The tests carried out in this study were compressive power, split tensile power, flexural power, and modulus of elasticity at the age of 28 days concrete. The number of samples made was 36 cylinders and 12 blocks for variations in percentage of 0%, 5%, 10%, 15%, 20% and 25%. The treatment of the specimens was done by immersing them for 26 days. The values of compressive power, split tensile power, flexural power, and elastic modulus will decrease when the percentage of palm shell ash in the concrete mixture increases. Abstrak Beton merupakan suatu material yang begitu vital untuk diaplikasikan dalam dunia konstruksi. Suatu materi yang bisa dimanfaatkan untuk menciptakan beton normal dengan metode ini adalah dengan menambahkan abu cangkang sawit ke dalam campuran beton. Abu cangkang sawit bisa dimanfaatkan selaku materi pengisi (filler), sebab abu tersebut memiliki kompenen kimia yang mengandung silika (SiO2) yang bersifat amorphus (bukan kristal) dan sangat reaktif pada temperature kamar. Penggunaan abu cangkang sawit selaku materi tambahan dalam campuran beton bertujuan untuk meningkatkan mutu beton yang direncanakan setelah abu cangkang sawit ditambahkan pada campuran beton. Percobaan yang diselenggarakan pada penelitian berikut adalah kuat tekan, kuat tarik belah, kuat lentur, dan modulus elastisitas terhadap usia beton 28 hari. Jumlah sampel yang dibuat adalah 36 buah berbentuk silinder dan 12 buah berbentuk balok dengan variasi persentase sebesar 0%, 5%, 10%, 15%, 20%, dan 25%. Perawatan materi pengujian dilakukan dengan upaya direndam dalam 26 hari. Hasil kuat tekan, kuat tarik belah, kuat lentur, dan modulus elastisitas menurun ketika persentase abu cangkang sawit pada campuran beton meningkat.
ANALISIS PERBANDINGAN PERAWATAN BETON TERHADAP MUTU BETON Evert, Ezra; Kushartomo, Widodo
JMTS: Jurnal Mitra Teknik Sipil Volume 7, Nomor 1, Februari 2024
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v7i1.24925

Abstract

There are many factors that affect the strength of concrete. Most of them are the constituent materials as well as concrete maintenance. The purpose of concrete maintenance is to maintain the concrete in a predetermined condition after opening the formwork. With concrete maintenance, the strength of concrete is expected to approach or reach the planned strength in the mix design. This study aims to understand the effect of the treatment method on the plan concrete with 20 MPa and 30 MPa on the compressive strength of concrete. The test specimens in this test are cylinders having a diameter of 10 cm and a height of 20 cm. The compressive strength test is carried out when the concrete is 14 and 28 days old. concrete treatment methods are divided into 3 variations, namely soaking, watering, and without treatment. The strength or quality of concrete obtained from this study for 20 MPa concrete of age 28 is 9.74 MPa for the treatment method left, 11.44 MPa for the treatment method watered, and 16.39 MPa for the treatment method soaked. The compressive strength obtained from this study for 30 MPa concrete at the age of 28 days was 20.53 MPa for the left treatment method, 30.34 MPa for the watered treatment method, and 32.32 MPa for the soaked treatment method. Abstrak Terdapat banyak faktor yang mempengaruhi kekuatan beton. Sebagian besarnya adalah material penyusunnya serta perawatan beton. Tujuan dari pemeliharaan beton untuk memelihara beton dalam kondisi yang sudah ditetapkan setelah pembukaan bekisting. Dengan adanya perawatan beton, kekuatan beton diharapkan mendekati atau mencapai kekuatan rencana dalam perencanaan campuran atau mix design. Studi ini bertujuan untuk memahami pengaruh metode perawatan pada beton rencana dengan mutu 20 MPa dan mutu 30 MPa terhadap kuat tekan beton. Benda uji dalam pengujian ini berbentuk silinder yang memiliki diameter 10 cm dan tinggi 20 cm. Uji kuat tekan dilakukan saat beton berumur 14 dan 28 hari. metode perawatan beton dibedakan menjadi 3 variasi yaitu perendaman, penyiraman, dan tanpa perawatan. Besar kekuatan atau mutu beton yang diperoleh dari penelitian ini untuk beton mutu 20 MPa umur 28 adalah 9,74 MPa untuk metode perawatan dibiarkan, 11,44 MPa untuk metode perawatan disiram, dan 16,39 MPa untuk metode perawatan direndam. Besar kuat tekan yang diperoleh dari penelitian ini untuk beton mutu 30 MPa umur 28 hari adalah 20,53 MPa untuk metode perawatan dibiarkan, 30,34 MPa untuk metode perawatan disiram, dan 32,32 MPa untuk metode perawatan direndam.
ANALISIS PENGGUNAAN SERAT RAMI TERHADAP SIFAT MEKANIS SELF COMPACTING CONCRETE (SCC) Hernandez, Hizkia; Kushartomo, Widodo
JMTS: Jurnal Mitra Teknik Sipil Volume 6, Nomor 4, November 2023
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v6i4.25048

Abstract

Concrete is a commonly used material in the field of building construction, nowadays many projects use self-compacting concrete (SCC). Concrete usually has high compressive strength but has weak tensile and flexural strength, Low strength of concrete can be increased by adding fiber as an additive. In this research, jute fiber is used as an ingredient to increase the tensile strength of concrete, considering that jute fiber is a natural fiber that is easily available, high tensile strength and cheap. In this research, the type of concrete made is SCC in the form of cylinders and beams with a volume variation of adding jute fiber as much as 0%, 1%, 1,5%, 2%, 2,5%. The number of samples made consisted of 6 cylinders and 3 beams for each volume variation of jute fiber used. Tests were conducted in the form of flexural strength, modulus of elasticity, split tensile strength, and compressive strength. Treatment of test objects is done by immersion. The test results showed that the split tensile and flexural strength of SCC concrete using jute fiber increased up to 2% volume. At the same time, the compressive strength and modulus of elasticity of SCC concrete continued to decrease with increasing jute fiber variation compared to normal SCC concrete. Abstrak Beton termasuk bahan yang umum digunakan dalam bidang konstruksi bangunan, Saat ini banyak proyek yang menggunakan beton yang bisa memadat sendiri (SCC). Beton biasanya memiliki kekuatan tekan yang tinggi tetapi memiliki kekuatan tarik dan lentur yang lemah, Kekuatan beton yang rendah dapat ditinggikan dengan ,menambahankan serat sebagai tambahan. Pada penelitian yang dikerjakan ini digunakan serat rami sebagai bahan untuk meningkatkan kuat tarik beton, mengingat serat rami merupakan serat alam yang mudah didapat, kuat tarik tinggi dan murah. Pada penelitian yang dikerjakan ini jenis beton yang dibuat berupa SCC bentuk silinder dan balok dengan variasi volume penambahan serat rami sebanyak 0%, 1%, 1,5%, 2%, 2,5%. Jumlah sampel yang dibuat yang terdiri dari 6 silinder dan 3 balok untuk setiap variasi volume serat rami yang digunakan. Pengujian yang dilakukan berupa, kuat lentur, modulus elastisitas kuat tarik belah, dan kuat tekan. Perawatan benda uji dilakukan dengan cara perendaman. Hasil pengujian menunjukkan kekuatan tarik belah dan lentur beton SCC menggunakan serat rami mengalami peningkatan sampai volume 2 %. Pada saat yang sama, kuat tekan dan modulus elastisitas beton SCC terus menurun dengan peningkatan variasi serat rami dibandingkan dengan beton SCC normal.
ANALISIS BETON HONEYCOMB DI PROYEK GW10 William, Lie Jorge; Kushartomo, Widodo
JMTS: Jurnal Mitra Teknik Sipil Volume 7, Nomor 1, Februari 2024
Publisher : Prodi Sarjana Teknik Sipil, FT, Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jmts.v7i1.26629

Abstract

The analysis of concrete honeycomb is a significant study in the field of civil engineering that aims to comprehend, identify, and address honeycomb issues in concrete structures. Honeycomb is a condition where there are voids or defects on the concrete surface, which can result in a decrease in the strength and durability of the structure. In this research, concrete samples experiencing honeycomb from various construction projects were collected and subsequently, tested by various non-destructive testing methods such as ultrasonic testing and radar penetration. The analysis revealed that factors such as inadequate compaction during concrete mixing, insufficient care during curing, and problems during the construction process can be the causes of honeycomb formation. By understanding the causes and consequences of this phenomenon, recommendations to prevent such defect are provided, together with the structural repair to ultimately enhanc the integrity and lifespan of concrete structures. Abstrak Analisis mengenai beton keropos adalah sebuah penelitian yang sangat penting dalam bidang rekayasa sipil. Tujuannya adalah untuk memahami, mengidentifikasi, dan mengatasi masalah yang berkaitan dengan fenomena keropos pada struktur beton. Keropos adalah keadaan di mana terdapat ruang kosong atau ketidaksempurnaan pada permukaan beton, yang dapat menyebabkan penurunan kekuatan dan daya tahan struktur tersebut. Dalam penelitian ini,  sampel beton yang mengalami keropos dari berbagai proyek konstruksi dikumpulkan dan  diuji menggunakan berbagai teknik pengujian non-destruktif, seperti ultrasonik dan radar penetrasi. Hasil analisis menunjukkan bahwa faktor-faktor seperti ketidakmerataan pemadatan selama proses pencampuran beton, perawatan yang kurang memadai selama proses pengerasan, serta masalah dalam pelaksanaan konstruksi dapat menjadi penyebab terbentuknya keropos. Dengan memahami penyebab dan dampak dari fenomena ini, saran untuk mencegahnya , yang pada akhirnya akan meningkatkan kekokohan dan umur panjang pada struktur beton tersebut.