Claim Missing Document
Check
Articles

Analysis of the Effects of Spark Plug Type and Electrode Gap on Exhaust Emission Performance: A Case Study of the Toyota Limo Arsy Sulaiman; Risal Abu; Mukhnizar Mukhnizar
The Future of Education Journal Vol 5 No 2 (2026)
Publisher : Lembaga Penerbitan dan Publikasi Ilmiah Yayasan Pendidikan Tumpuan Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61445/tofedu.v5i2.1991

Abstract

The transportation sector is the largest contributor to air pollution in urban areas due to the extensive use of fossil fuels. This study aims to analyze the effect of spark plug types and variations in electrode gap distance on the exhaust emission levels of Carbon Monoxide (CO) and Hydrocarbons (HC) in a 2008 Toyota Limo. The testing parameters utilized three types of spark plugs nickel, platinum, and iridium with variations in gap distances: standard (0.9 mm–1.1 mm), narrow (0.5 mm), and wide (1.5 mm) across various engine speeds (RPM). ​The research method involved direct testing using a Gas Analyzer at the Motor Vehicle Testing Technical Service Unit (UPT-PKB) in Padang Pariaman Regency. The collected data, comprising CO and HC emission results, were analyzed to determine the combustion efficiency within the combustion chamber. ​The results indicate that the spark plug gap distance has a more significant impact on emissions than the spark plug material itself. Using the standard gap distance consistently yielded the best emission results across all spark plug types. Overall, the iridium spark plug with a 1.1 mm standard gap produced the lowest emission levels, specifically 0.36% for CO and 55 ppm for HC at 2000 RPM. This proves that premium electrode materials produce a more focused and powerful spark, leading to more complete and environmentally friendly combustion, provided they are supported by the manufacturer's recommended gap distance
Performance Evaluation of a Centrifugal Pump at the Gunung Pangilun Drinking Water Treatment Installation, Padang Regional Public Water Utility Company Rama Pranata; Risal Abu; Mukhnizar Mukhnizar
The Future of Education Journal Vol 5 No 2 (2026)
Publisher : Lembaga Penerbitan dan Publikasi Ilmiah Yayasan Pendidikan Tumpuan Bangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61445/tofedu.v5i2.2111

Abstract

The availability of clean water is a fundamental need that must be continuously ensured. The Regional Drinking Water Company (Perumda) of Padang City utilizes centrifugal pumps to distribute water from the intake to the reservoir. However, decreased pump performance can lead to an imbalance between water supply capacity and demand. This study aims to analyze the performance of centrifugal pumps at the Gunung Pangilun Water Treatment Unit, particularly in terms of flow capacity, efficiency, and power consumption. The results show that the combined actual discharge of two pumps was 2250 m³/h, which is 24.24% lower than the specified capacity of 2970 m³/h. The average head was 42 meters with a discharge pressure of 4.2 bar. The pump efficiency decreased compared to the design condition due to flow losses and equipment aging factors. It can be concluded that the pump performance is still within an acceptable range but has experienced a decline in capacity and efficiency. Therefore, regular maintenance and system evaluation are required to improve operational performance and energy efficiency.
INSTALLATION OF PUBLIC FACILITIES LIGHTING IN PASA LIMAU PARIT MALINTANG Muknizar, Muknizar; mallisza, Danyl Mallisza; Slamet Riyadi; Risal Abu; Dewirman Prima Putra; Ahmad Fikri; Niko Zainuddin Muchtar; Muhammad Alimuddin Hafidz; Raden Roro Anggun Tutur Winasis; Raka Putra Hanafi; Asrul, Asrul; Putra Hajril Fajri; Refnaldi Pramana
Journal of Community Service Vol 8 No 1 (2026): JCS, June 2026
Publisher : Ikatan Dosen Menulis

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56670/jcs.v8i1.444

Abstract

Korong Pasa Limau is one of the villages in Nagari Parit Malintang, where the village has a surau (prayer hall) that has just been built and is located among the Guci community. The problem faced by the residents of Korong Pasa Limau is the safety of residents who want to pray at the newly built surau, named Surau Sungsang. Before Surau Sungsang was built by the residents of Korong Pasa Limau, the korong already had a surau located downhill, so residents who wanted to pray had to walk down and were at risk of falling or slipping on the descending path leading to that surau. Student Real Work Lecture (KKN-PPM) community service activities are carried out to solve problems that occur in the environment. One of them is by providing public facilities in the form of lighting at Surau Sungsang for residents to be able to start worshiping there. Students from Group 22 of KKN-PPM UNES 2024 installed lighting for Surau Sungsang using an electric power source from PLN, with a total of 8 light installation points at Surau Sungsang, Korong Pasa Limau.
Analisis Kerusakan Hydraulic Cylinder Bucket Excavator Caterpillar Cat 336 E L Aditya Ferira; Muknizar Muknizar; Zulkarnain Zulkarnain; Risal Abu; Veny Selviyanty
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 3 (2026): July
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i3.62330

Abstract

An excavator (specifically a pull-shovel) is a machine designed to excavate material located below its own operating level. Hydraulic cylinders are critical components that actuate attachments such as the boom, arm, and bucket. Among these attachments, the bucket cylinder is the most prone to failure because it interacts directly with the material being excavated. Frequent failures lead to increased downtime and disrupt production processes. The primary causes of bucket cylinder failure in the Caterpillar Cat 336 EL excavator are seal and O-ring damage, as well as oil contamination, both of which result in cylinder leakage. Maintenance measures taken to address these failures include: (i) replacing the seal kit on the cylinder head and piston to prevent pressure loss; (ii) inspecting the internal brass bushing—if the bushing is worn or damaged (which can cause new seals to leak), it must be replaced; and (iii) cleaning the cylinder and rectifying issues related to oil contamination. 
Analisis Pengaruh Proses Quenching Menggunakan Media Pendingin Terhadap Kekerasan Baja ST 37 Rizki Rivo Ramadhan; Risal Abu; Mukhnizar Mukhnizar
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64211

Abstract

Carbon steel is widely used in the manufacture of tools, automotive components, and household items. Operational use causes deformation in the metal's structure. This study aimed to determine the effect of quenching—using vinegar, mature coconut water, and Sunlight soap solution as cooling media—on the hardness of ST37 steel subjected to heat treatment at 800°C. Following the quenching process, hardness testing was conducted using a Micro-Vickers tester. The hardness value of the untreated steel was 192.33 HV, while the values ​​obtained using vinegar, mature coconut water, and Sunlight solution were 198.88 HV, 159.66 HV, and 134.88 HV, respectively. Specimens quenched in vinegar showed a hardness increase of 6.55 HV, whereas those quenched in mature coconut water and Sunlight solution showed decreases of 32.67 HV and 57.45 HV, respectively. The percentage changes in hardness for ST37 steel were +3.14% for vinegar, -16.99% for mature coconut water, and -29.87% for Sunlight solution.
Analisis Pengaruh Variasi Arus Pengelasan Terhadap Kekuatan Tarik Las SMAW dengan Elektroda E7014 Pada Baja Karbon Menengah Bintang Tri Wardana; Risal Abu; Zulkarnain Zulkarnain
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64212

Abstract

Welding plays a crucial role as it determines the strength, safety, and service life of a structure. One method employed is Shielded Metal Arc Welding (SMAW). Electric current is a primary parameter affecting weld quality; an excessively low current results in insufficient penetration, while an excessively high current can reduce the tensile strength of the joint. This study aims to investigate the effect of varying current on the tensile strength of welded joints in AISI 1045 medium-carbon steel, using 3.2 mm diameter E7014 electrodes. The research was conducted by varying the current—110 A, 130 A, and 150 A—using direct current electrode positive (DCEP) polarity in the flat (downhand) welding position. The results indicate that increasing the welding current influences the tensile strength of the welded joints. The highest tensile strength was obtained at 150 A (322.09 N/mm²), while the lowest was recorded at 110 A (136.83 N/mm²); a current of 130 A yielded an intermediate value of 239.88 N/mm². This is because an increase in heat input improves both penetration and the homogeneity of the weld metal structure.
Analisis Coefficient of Performance (COP) Sistem Refrigerasi R404a pada Cold Storage di Ramayana Plaza Andalas Padang Darus Samin; Risal Abu; Mukhnizar Mukhnizar
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64629

Abstract

Cold storage is a low-temperature storage facility that plays a crucial role in maintaining product quality within the food industry and modern commerce. The refrigeration system in this facility utilizes R404A refrigerant, a replacement for the original R22 refrigerant; yet, to date, no specific study has been conducted on the system's Coefficient of Performance (COP). Measurements and analysis indicate a refrigeration effect of 100.2 kJ/kg and a compressor work input of 65.5 kJ/kg. Although the COP value suggests that the system is capable of performing its cooling function effectively (maintaining a temperature of −20 °C), it is not yet operating optimally. An analysis of operational parameters shows that the superheat on the suction side (9.1 °C) and the evaporator air temperature differential (4.8 °C) remain within the normal range. However, a subcooling value in the liquid line approaching 0 °C suggests that the refrigerant retrofit process—from R22 to R404A—has not been fully optimized, particularly regarding the refrigerant charge quantity and the compatibility of the lubricating oil. This is believed to be one of the factors contributing to the system's suboptimal COP.
Analisis Variasi Kuat Arus terhadap Kekuatan Uji Tarik Pengelasan SMAW pada Pelat Baja Karbon Rendah AISI 1020 Tri Yuli Padrji; Risal Abu; Azmil Azman
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64681

Abstract

Welding is a joining method in which the quality of the weld joint is influenced by a specific heat input. Electric current determines the depth of penetration as well as the microstructure within the heat-affected zone (HAZ). This study aims to analyze the effect of varying welding currents 90 A, 110 A, and 130 A on the tensile strength ( of AISI 1020 steel joints. The test results show tensile strength ( values ​​of 304.91 N/mm² at 90 A, 341.47 N/mm² at 110 A, and 311.97 N/mm² at 130 A. The corresponding yield strength ( ) values ​​are 213.55 N/mm², 239.04 N/mm², and 218.40 N/mm², while the strain (ε) values ​​are 6.00%, 6.53%, and 4.00%, respectively. It can be concluded that a current of 110 A is the optimal parameter for achieving maximum tensile strength. Using a current of 90 A results in incomplete penetration, whereas a current of 130 A leads to excessive heat input, which widens the heat-affected zone and degrades the material's mechanical properties due to coarse grain growth.
Analisis Kerusakan Kompresor HVAC untuk Tindakan Perawatan di PT. Supreme Energy Muara Labuh Egi Candra Adrial; Risal Abu; Mukhnizar Mukhnizar
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 4 (2026): October
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i4.64721

Abstract

An HVAC system serves not only to regulate room temperature but also to maintain air quality, humidity, and the overall comfort and safety of the work environment. The reliability of an HVAC system depends on the performance of its key components. However, inadequate maintenance can lead to minor issues that may eventually escalate into serious problems. This study aims to analyze the failures that occur, evaluate the current maintenance system, and propose an improved maintenance approach. Based on an analysis using the Failure Mode and Effects Analysis (FMEA) method, five potential failures in an HVAC compressor were identified: low suction pressure, high discharge pressure, refrigerant leakage, expansion valve failure, and compressor overheating. The calculated Risk Priority Number (RPN) values ​​are as follows: high discharge pressure (216), compressor overheating (200), low suction pressure (192), refrigerant leakage (160), and expansion valve failure (140).