cover
Contact Name
David Setiawan
Contact Email
dsetia@unilak.ac.id
Phone
-
Journal Mail Official
dsetia@unilak.ac.id
Editorial Address
-
Location
Kota pekanbaru,
Riau
INDONESIA
Jurnal Teknik
ISSN : 18584217     EISSN : 2622710X     DOI : -
Core Subject : Art, Engineering,
Jurnal Teknik has an area of expertise consisting of : 1. Civil Engineering such as Structural Engineering, Construction Engineering & Management, Geotechnical Engineering, Water Resources Engineering, Transportation Engineering and Ocean Engineering. 2. Electronical Engineering such as Electrical Engineering Materials, Electric Power Generation, Transmission and Distribution, Power Electronics, Power Quality, Power Economic, FACTS, Renewable Energy, Electric Traction, Electromagnetic Compatibility, High Voltage Insulation Technologies, High Voltage Apparatuses, Lightning Detection and Protection, Power System Analysis, SCADA, Electrical Measurements. 3. Architectural such as Indonesian Architectural Design, Housing and Urban Design and Development, Vernacular Architecture, Islamic Architecture, Architectural Science & Technology, Interdisciplinary Architecture, and other Indonesian Architecture discourses.
Arjuna Subject : -
Articles 170 Documents
Evaluasi Kualitas Mutu Pembangunan Infrastruktur Pedesaan Khusus Alokasi Dana Desa (ADD 2019) Studi Kasus : Kecamatan Depati Tujuh Glodea Aura Zalsa; Ade Nurdin; M Nuklirullah
JURNAL TEKNIK Vol. 16 No. 2 (2022): Edisi Oktober 2022
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.9900

Abstract

Sebagai Engineer kualitas suatu pembangunan dilihat dari perencanaan dan pengendalian pekerjaan agar mencapai pembangunan yang baik. Kualitas produk akhir dan tidak terpenuhi, bangunan berimplikasi pada umur struktur di karenakan Penyimpangan prosedur pekerjaan yang seringkali diabaikan oleh masyarakat, menjadikan harapan kualitas akhir produk tidak dapat tercapai. Dalam menunjang kesejahteraan masyarakat desa maka perencanaan dan pengadaan meliputi identifikasi kebutuhan dalam bentuk fasilitas konstruksi yang berkualitas yang bisa di gunakan dalam umur panjang untuk tercapainya keinginan masyarakat yang di harapkan oleh pemerintah desa. Untuk itu di harapkan dalam penggerakan pengujian mutu harus diutamakan dalam bidang struktur agar infrastruktur yang di harapkan tercapai pada umur rencana dan memuaskan. di wilayah Kecamatan Depati Tujuh yang terletak di kabupaten kerinci yang merupakan wilayah pertanian memerlukan perhatian dari aspek mutu pembangunan yang di terapkan pada perencanaan dan pelaksanaan. Pelaksanaan pembangunan pada pedesaan yang merupakan pembangunan lepas yang biasanya sering di lakukan oleh pihak desa saja tidak ada penggunaan jasa manajemen konstruksi. Bertepatan dari hal itu maka pengendalian proyek yang di lakukan oleh desa dilakukan dengan seadanya, dan mengandalkan pendamping desa untuk mengendali pelaksanaan proyek.
Karakteristik Beton Crumb Rubber dan Abu Sekam Menggunakan Air Gambut Sebagai Pencampur dan Perawatan Beton Nur Alfikri; Monita Olivia; Gunawan Wibisono
JURNAL TEKNIK Vol. 16 No. 2 (2022): Edisi Oktober 2022
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.9905

Abstract

Ketersediaan air bersih yang terbatas di lingkungan gambut menjadi permasalahan yang sangat serius. Hal ini menyebabkan penggunaan air gambut menjadi alternatif pemenuhan air untuk pembuatan beton di provinsi Riau tidak dapat dihindari. Tujuan penelitian ini adalah Mengkaji pengaruh air gambut sebagai air campuran dan perawatan beton dengan mutu rencana f’c 35 MPa. Pada penelitian ini, beton Portland Composite Cement (PCC) digunakan sebagai beton kontrol. Sedangkan beton PCC CR RHA menggunakan crumb rubber sebesar 5% dari volume agregat halus, dan abu sekam padi sebanyak 10% dari volume semen. Pengujian kuat tekan, kuat tarik, dan kuat lentur dilakukan dengan perendaman selama 56 hari di air normal maupun di air gambut. Hasil pengujian menunjukkan kuat tekan, kuat tarik, dan kuat lentur beton PCC dan beton PCC CR RHA meningkat dengan bertambahnya umur beton, baik itu dilakukan dengan pencampuran air normal maupun pada saat perendaman dengan air gambut. Berdasarkan hasil pengujian yang dilakukan, beton PCC CR RHA memiliki kuat tekan, kuat tarik, dan kuat lentur yang lebih tinggi dibandingkan dengan beton PCC pada kondisi air gambut sebagai air pencampuran dan perawatan sehingga dapat disimpulkan bahwa crumb rubber dan abu sekam padi dapat meningkatkan ketahanan beton di lingkungan gambut.
TATA MASSA BANGUNAN SEKOLAH TINGGI SENI PERTUNJUKAN : Pendekatan Arsitektur Metafora repi, repi; Masrul, Wati
JURNAL TEKNIK Vol. 17 No. 2 (2023): Edisi Oktober 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.10293

Abstract

Sekolah Tinggi Seni Pertunjukan merupakan fasilitas pendidikan yang berfokus pada bidang seni pertunjukan. Sekolah tinggi dirancang dengan tujuan menyediakan sarana pendidikan seni pertunjukan dalam bentuk Sekolah Tinggi bagi masyarakat Provinsi Riau yang memiliki minat dan bakat seni pertunjukan. Sekolah tinggi seni pertunjukan terdiri dari tiga program studi yaitu program studi seni musik, seni tari, dan seni teater. Dengan adanya Sekolah Tinggi Seni Pertunjukan di Pekanbaru, diharapkan dapat memenuhi kebutuhan pendidikan formal yang memadai dibidang seni pertunjukan. Metode Penelitian yang akan dipakai yaitu metode kualitatif dengan melakukan analisis terhadap beberapa aspek yaitu aspek manusia dan bangunan yang akan dijelaskan secara naratif. Hasil penelitian ini berupa konsep sekolah tinggi seni pertunjukan dengan menerapkan tema metafora dari nilai-nilai yang terkandung di dalam tepak sirih terhadap pola tata massa bangunan yaitu menata massa bangunan utama sesuai dengan fungsi, urutan cembul dan makna yang terkandung di dalam cembul pada tepak sirih
Model Rancangan Apartemen Dengan Pendekatan Arsitektur Bioklimatik Firdaus, Rahmatan; Masrul, Wati; Silva, Hendri
JURNAL TEKNIK Vol. 17 No. 1 (2023): Edisi April 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.10391

Abstract

Apartemen merupakan hunian masa depan masyarakat yang memiliki aktifitas dan rutinitas masyarakat perkotaan, dimana ketersediaan lahan di tengah kota semakin berkurang dan kebutuhan akan hunian pada pusat kota semakin bertambah. Apartemen untuk keluarga muda menjadi solusi hunian yang merupakan tempat pembinaan bagi keluarga muda yang baru memulai hidup mandiri dan menentukan sendiri orientasi hidupnya, maka fasilitas yang terdapat didalamnya menunjang untuk tujuan tersebut. Untuk mendukung produktivitas orang muda dalam bekerja, maka memerlukan lokasi yang strategis yang menjangkau tempat bekerja. Dipilihnya lokasi tersebut dilatar belakangi oleh tujuan untuk mempersingkat jarak tempuh penghuni ke tempat bekerja yaitu di pusat-pusatkota Pekanbaru juga memperbaiki kualitas lingkungan sekitar sehingga menjadikan hunian yang sehat namun tetap terjangkau oleh keluarga muda. Diharapkan dengan adanya apartemen bagi para keluarga muda diharap mampu meningkatkan kualitas hidupnya serta mendorong hidup sehat yang sesuai dengan karakter penghuni yaitu golongan muda yang produktif.
Kerusakan Jalan Pada Jalan Maredan Kecamatan Tualang Kabupaten Siak Dengan Metode Pavement Conditon Index (PCI) STA 41+770 – STA 46+770 Munziri; Winayati; Rahmat, Hendri
JURNAL TEKNIK Vol. 17 No. 1 (2023): Edisi April 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.10968

Abstract

Jalan Maredan is one of the access roads to Perawang Village which is located in Maredan Village, Tualang District, Siak Regency, Riau Province. The road was severely damaged, especially at STA 41+770 to STA 46+770, there were many types of road damage, such as potholes, subsidence, longitudinal cracks, and crocodile skin cracks. The purpose of this study was to determine the level of road damage on Jalan Maredan, Tualang District, Siak Regency, STA 41+770 to STA 46+770 using the Pavement Condition Index method and how to handle each road damage. From the results of the analysis, it was found that the accumulative PCI value starting from STA 41+770 to STA 46+770 was 35,78 % and the pavement condition was in poor condition. As for the handling that can be done in overcoming road damage, it is necessary to carry out routine road maintenance, periodic road maintenance, road rehabilitation, or road reconstruction.
Kegagalan Poros Input Gearbox Screw Decanter pada Unit Pengolah Limbah Kelapa Sawit adi, Adi Febrianton; Sepfitrah; Romiyadi; Yuvendius, Hazra; Irwan, Purnama
JURNAL TEKNIK Vol. 17 No. 1 (2023): Edisi April 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.11049

Abstract

The use of Centrifuge Decanter as a waste treatment in industry has been widely used. Centrifuge Decanter separates waste in the form of a mixture of solids and liquids (slury) by utilizing the centrifugal force generated by the difference in the rotation of the tube (bowl) and screw conveyor. The rotation of the screw conveyor is reduced through a cycloidal gearbox. The shaft in the cycloid breaks during operation, for that it is necessary to conduct research to determine the cause of this shaft fracture. This research starts from a literature study that discusses the working mechanism of the decanter and the causes of the failure of the cycloidal gearbox shaft. For completeness of the analysis, data collection includes data on engine operation, physical and mechanical properties of the shaft material, fractography of the shaft and the stresses acting on the shaft. From the results of data analysis, it is known that the shaft has ductile fracture due to overload. The load that causes the shaft to break is the torsional load that comes from the rotation of the decanter tube at the initial start of the engine. Torque due to the rotation of the tube produces a shear stress that exceeds the yield stress of the shaft material plus a stress concentration factor in the fractured shaft fillet area.
Sistem SCADA Pada Jaringan Distribusi PT.PLN (Persero) UP2D Pekanbaru Samuel Dwi Wirayanto; Arlenny Arlenny; Elvira Zondra
JURNAL TEKNIK Vol. 16 No. 2 (2022): Edisi Oktober 2022
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v16i2.11094

Abstract

ABSTRAK Pada jaringan distribusi PT. PLN (Persero) UP2D Pekanbaru Penyulang eksisting sudah terkoneksi dengan sistem SCADA, namun jika dilihat dari infrastruktur pendukungnya, integrasi sistem SCADA dengan jaringan distribusi PT. PLN (Persero) UP2D Pekanbaru masih belum optimal, sehingga pada tugas akhir ini akan dibahas perbaikan kinerja sistem SCADA untuk meningkatkan keandalan jaringan distribusi PT. PLN (Persero) UP2D Pekanbaru Penggunaan SCADA (Supervisory Control and Data Aquisition) pada jaringan sistem distribusi UP2D Pekanbaru sangat berpengaruh kepada tingkat indeks keandalan SAIDI (system average interruption duration index),SAIFI (system average interruption frequency index ) dan CAIDI CAIDI (customer average interruption duration index), Indeks keandalan SAIDI pada jaringan Distrbusi UP2D Pekanbaru mengalami penurunan dari nilai indeks 2.115 menit/pelanggan sebelum terintegrasi dengan SCADA menjadi 1.802 menit/pelanggan setelah terintegrasi dengan sistem SCADA, sedangkan untuk indek SAIFI mengalami penurunan nilai indeks 23,164 kali/pelanggan sebelum terintegrasi dengan sistem SCADA menjadi 21,685 kali/pelanggan setelah terintegrasi dengan sistem SCADA, untuk indeks CAIDI dari nilai indeks 85,805 menit/pelanggan sebelum terintegrasi dengan sistem SCADA, mengalami penurunan nilai indeks menjadi 85,561 menit/pelanggan setelah terintegrasi dengan sistem SCADA. Sistem Distribusi UP2D Pekanbaru mengalami peningkatan indeks keandalan sistem Distribusi setelah terintegrasi dengan sistem SCADA, dengan parameter indeks SAIDI, SAIFI dan CAIDI, perhitungan analisis indeks SAIDI yaitu sebesar 14,799% dan SAIFI sebesar 6,384%, sedangkan untuk indeks CAIDI yaitu sebesar 0,337%.
Penerapan Keselamatan dan Kesehatan Kerja Pada Pekerjaan Pemeliharaan Pumping Unit PT Vadhana Internasional Lubis, Fadrizal; Ferdiansyah, Hendrik; Anggraini , Muthia
JURNAL TEKNIK Vol. 17 No. 1 (2023): Edisi April 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v17i1.13251

Abstract

Pekerjaan Pemeliharaan Pumping Unit adalah proses pemeliharaan salah satu alat pompa minyak bumi yang digerakan secara mekanik dengan memakai sumber energi listrik. Tingginya potensi bahaya dalam pekerjaan Pemeliharaan Pumping Unit ini menuntut penerapan Keselamatan dan Kesehatan Kerja (K3) yang baik. Berdasarkan Standar AS/NZS 4360:2004, level resiko terhadap pekerjaan yaitu mulai level yang terendah hingga resiko tertinggi yang bisa terjadi. Tujuan penelitian bagaimana penerapan Keselamatan dan Kesehatan Kerja pada Pekerjaan Pemeliharaan Pumping Unit di PT. Vadhana Internasional.merujuk pada PP No.50 Tahun 2012 dan Metode Kano. Metode penelitian yang diberikan kepada responden yang terkait pada pekerjaan mulai dari level terendah hingga level supervisor. Hasilnya menunjukkan tingkat pencapaian nilai 95,31 % tergolong dalam kategori nomor 3 yaitu level penerapan memuaskan, sebagai kategori awal dengan pemenuhan 61 kriteria dari total 64 kriteria dan terdapat 3 kriteria yang tidak terpenuhi dengan nilai 4,69% kategori kurang. Pada Metode Kano dalam bentuk program Visual studio.net berbasis aplikasi yang secara otomatis akan memberikan hasil perhitungan dari kuisoner yang telah dikumpulkan dari responden menunjukkan nilai memuaskan artinya perusahaan masih memenuhi terhadap penerapan Sistem Manajemen Keselamatan dan Kesehatan Kerja (SMK3) yang dapat dilihat nilai Better masih lebih besar dari nilai Worse .
Analisis Kerusakan Jalan dengan Metode Bina Marga dan Respon Pengguna Jalan terhadap Perbaikannya (Studi Kasus Ruas Jalan Jurong Bonai Darussalam) saleh*, alfian; Muzki, Deni; Winayati
JURNAL TEKNIK Vol. 18 No. 1 (2024): Edisi April 2024
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v18i1.10964

Abstract

Jurong road is a road which is located in Bonai Darussalam District, Rokan Hulu province. It is a road of 111 km (11 mi) long, and 6 m (20 ft) wide, it is a road leading to the pangararsand, where large cars often drive. Across the jurong road line, a vast range of road damage was found, at exactly 1, ooo to 1, ooo. The purpose in this study is to know the rate of road damage, and the effect of road damage on road use on jurong street, bonai darussalam district, upper rokan district, (sta 16+000 to sta 18+000) using clan building methods. Got results from jurong road damage survey with the kinds of cracked crocodile skin, buckskin, and holes. From the results of the damage analysis using clan building methods, results from the rate of damage or priority order (up) value are 9 which means that jurong street belongs to the regular maintenance category. And the results of the jurong road damage survey analysis using a likert scale method with a total of 50 respondents found at a percentage increase of 83,68 %, and based on the assessment interval of road conditions according to clan building values, it is between 80% % - 100 %, indicating that road damage is important to road users and that people are more than willing to make road improvements
STUDI EKSPERIMENTAL PENAMBAHAN ZAT ADDITIF MASTERSURE 1007 TERHADAP KUAT TEKAN BETON SILINDER FC'30: STUDI EKSPERIMENTAL PENAMBAHAN ZAT ADDITIF MASTERSURE 1007 TERHADAP KUAT TEKAN BETON SILINDER FC'30 Kurniawan*, Mahadi; Ahmadi, Heri; Syarif, Firman; Hartati Dewi, Sri; Rachmat Setiawan, Panji; Kahrywal, Kahrywal
JURNAL TEKNIK Vol. 17 No. 2 (2023): Edisi Oktober 2023
Publisher : JURNAL TEKNIK UNILAK

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31849/teknik.v17i2.12231

Abstract

ABSTRAK Beton adalah campuran antara semen portland atau semen hidrolis lainnya, agregat halus, agregat kasar dan air dengan atau tanpa bahan tambahan, membentuk massa padat, kuat, dan stabil. Dalam proses pembuatan beton yang mempunyai jarak pengecoran yang jauh dan membutuhkan waktu lama pada saat pengecoran maka diperlukan suatu bahan tambah kimia pada campuran beton salah satunya zat additif Mastersure 1007. Bahan tambah ini dapat berfungsi memperlambat proses pengikatan beton, menaikkan nilai slump, mengurangi pemakaian air, dan meningkatkan kuat tekan beton dalam satu waktu. Penelitian ini menggunakan sampel silinder. Persentase bahan tambah Mastersure 1007 yang digunakan ada 4 varian yaitu 0%, 0.8%, 1% dan 1.2% dari total berat semen. Metode yang digunakan untuk pehitungan campuran beton (mix design) berdasarkan SNI 03-2834-2000. Pengujian dilakukan pada umur 3 hari, 7 hari dan 28 hari. Penelitian dilakukan dengan bahan tambah Mastersure 1007 dengan dosis 0%, 0,8%; 1%; 1,2% dari total berat semen, apakah dapat menahan nilai slump pada beberapa waktu pengadukan dan peningkatan kuat tekan pada dosis 0%; 0,8%; 1%; dan 1,2%. Dari hasil pengujian slump yang telah dilakukan ternyata semakin besar dosis bahan tambah Mastersure 1007 nilai slump yang didapat semakin rendah. Hal ini terjadi akibat reaksi retarder yang terkandung di dalam bahan tambah pada semen tidak bereaksi secara maksimal pada dosis tinggi. Dari hasil pengujian beton yang telah dilakukan, proses pembentukan beton pada umur 3 hari lebih cepat dari pada beton dengan umur 7 hari dan 28 hari. Hasil kuat tekan beton dari penambahan Mastersure 1007 semakin besar dosis bahan tambah yang di tambahkan maka semakin tinggi nilai kuat tekan yang diperoleh. Tetapi pada umur pengujian 7 hari diperoleh hasil yang tidak stabil. Hasil yang diperoleh tersebut membuktikan bahwa kuat tekan beton dengan penambahan Mastersure 1007 pada dosis yang tinggi akan menurunkan nilai slump pada beton sedangkan untuk dosis yang semakin tinggi maka kuat tekan akan semakin meningkat. Kata Kunci: Beton, Mastersure 1007, kuat tekan, beton silinder, slump