Comparison Analysis of Seismic Base Shear 23 Regencies in Aceh Province Based on SNI 03-1726-2012 and SNI 03-1726-2019 Rahmaini Rahmaini; Fitri Arianggi; Maizuar Maizuar; David Sarana; Khairullah Yusuf
International Journal of Engineering, Science and Information Technology Vol 2, No 3 (2022)
Publisher : Master Program of Information Technology, Universitas Malikussaleh, Aceh Utara, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (521.272 KB) | DOI: 10.52088/ijesty.v2i3.310

Abstract

Aceh is one of the most earthquake-prone regions in Indonesia. It is, therefore, essential to design seismic resistance structures according to applicable standards. To reduce damage to building structures, the Indonesian government has updated the seismic-resistant design code for building and non-building structures. The seismic resistant design standard has been updated from SNI 03-1726-2012 to SNI 03-1726-2019 due to a significant change in spectrum response data. The purpose of this study was to evaluate and compare the impacts on the seismic base shear and the cross-sectional area of columns, beams, and tie beams of buildings in 23 regencies in Aceh Province based on SNI 03-1726-2012 and SNI 03-1726-2019. A typical five-story office building with medium-type soil is used in the study. For structural analysis, a particular moment-resistant frame was considered. The determination of the design response spectra is carried out by using coordinates and soil types through the website “indo spectra”. The method used is spectrum response analysis. Some different requirements in the two standards include the spectrum response curve, mass participation, and dynamic base shear. The study’s results revealed that the dynamic base shear in Sabang City had grown by 192.05 percent. Aceh Barat Daya Regency was observed to have the smallest increase in dynamic base shear, which was only 8.16 percent. The required cross-sectional area of structural columns, beams, and tie beams in Sabang City increased by 96%, 40%, and 44.44%, respectively; in the meantime, the required cross-sectional area of columns, beams, and tie beams in several regencies in Aceh province remained unchanged.
The Effect of The Use Of Foam Agent and Clam Shell Powder on The Compressive Strength and Absorbency of Concrete Teuku Ikmal; Sari Indah Manik; Khairullah Yusuf; David Sarana; Amalia Amalia
International Journal of Engineering, Science and Information Technology Vol 2, No 3 (2022)
Publisher : Master Program of Information Technology, Universitas Malikussaleh, Aceh Utara, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (268.162 KB) | DOI: 10.52088/ijesty.v2i3.315

Abstract

A foaming agent is a concentrated solution of surfactant material that must be dissolved in water before mixing with other concrete material. The foaming agent is used to produce lightweight concrete with a density is £ 1.900 kg/m³. Using foam agents may affect the compressive strength and absorbency of the concrete. Hence, adding clam shells is expected to improve the compressive strength of the foam concrete. In addition, it is also essential to investigate the effects of utilizing foam agents and clam shells on the density of the foam concrete. Nine concrete mixes namely 1 variation of standard concrete, four variations of concrete mixes with foam agent, and four variations of concrete with foam agent and calm shell have been studied to investigate the parameters.The variation of foam agents in the eight concrete mixes were 5%, 10%, 15%, and 20% by water weight. The last four variations contained clamshell of 5% by weight of fine aggregate. The foam agent wasfoamingduced by mixing with a ratio of water and foam agent of 40:1. The experimental results show that at the variation of 20% foam agent, the density reduced by 34.55% and 26.89% for foam concrete with and without clam shell compared to normal concrete. I contrast, adding clamshell also lowered down the compressive strength of foam concrete by 79.86% and 74.96% for the variations. Meanwhile, the highest absorption rate of 1.65% or increased about 6.45% from normal concrete occurred at a variation foam agent of 15% mixed with clamshell. It was concluded that the use of clam shell in the foam concrete seems to decrease the strength of the foam concrete. However, in terms of density, the use of clam shells benefits foam concrete by lowering the self-weight of concrete.