cover
Contact Name
Nurul Jannah Asid
Contact Email
jurnalproteksi@unesa.ac.id
Phone
+6287849941119
Journal Mail Official
jurnalproteksi@unesa.ac.id
Editorial Address
Department of Civil Engineering - Faculty of Engineering - Universitas Negeri Surabaya Jl. Kampus Ketintang, Gedung A4, Unesa, Surabaya, 60231
Location
Kota surabaya,
Jawa timur
INDONESIA
Publikasi Riset Orientasi Teknik Sipil (Proteksi)
ISSN : -     EISSN : 26556421     DOI : -
Core Subject : Engineering,
Publikasi Riset Orientasi Teknik Sipil (Proteksi), ISSN No. 2655-6421 is a venue for publicizing scientific research activities in the field of Civil Engineering, necessarily restricted to structures, geotechnic and earthquakes, transportation, highway and railway, construction materials, water resources, hydrology and hydraulic, environment, surveying, monitoring and control systems, health and safety in construction. Proteksi is a peer-reviewed journal that is published by Universitas Negeri Surabaya or the State University of Surabaya in collaboration with Himpunan Ahli Teknik Tanah (HATTI) Cabang Jatim or Soil Engineering Expert (HATTI) East Java Branch. Proteksi is published by the Department of Civil Engineering, Faculty of Engineering, State University of Surabaya - Indonesia with publishing period twice in a year. The articles published in Proteksi been through the editing process and rigorous assessment of third parties who joined as a mitra bebestari. This editing process aims to ensure the accuracy of the content of the article as well as guarantee the accuracy of information as expected by the reader. The article published in Proteksi be accessible online and can be downloaded without charge (free of charge). We invite researchers, academics, and practitioners to publish research results in this journal. The language used in this journal is English and Bahasa Indonesia. Proteksi published by the Department of Civil Engineering, Faculty of Engineering, Universitas Negeri Surabaya (Unesa), Surabaya, East Java, Indonesia. Proteksi published twice a year, in Juni and December, Proteksi includes research in the field of Structures, Geotechnic and Earthquakes, Construction Management, Transportation, Highway and Railway , Construction Materials, Water Resources, Hydrology and Hydraulics, Environment, Surveying, Monitoring, and Control Systems, Health and Safety in Construction. Editors invite research lecturers, the reviewer, practitioners, industry, and observers to contribute to this journal.
Articles 153 Documents
Optimalisasi Jaringan Trayek Suroboyo Bus Berdasarkan Pemetaan OD (Origin Destination) dengan Aplikasi Web App Map Arcgis Wibisono, R. Endro; Susanti, Anita; Supriyatno, Dadang; Widayanti, Ari; Septika, Erisa Widya
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 5 No 2 (2023): Vol. 5 No. 2 (2023)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v5n2.p108-118

Abstract

Pemerintah Kota Surabaya berupaya menanggulangi kemacetan yang ada dengan menyediakan BRT (Bus Rapid Transit) yang dikenal dengan Suroboyo Bus. Pengalihan rute dari Suroboyo Bus kepada BRT lain, menyebabkan banyaknya keluhan oleh pengguna yang meminta penambahan rute di ruas-ruas jalan di Kota Surabaya, agar integrasi rute dan tarif dapat diberlakukan. Berpijak pada permasalahan diatas, maka penelitian mengenai pemetaan origin destination penumpang Suroboyo Bus berbasis web, penting dilakukan dengan tujuan untuk mengetahui gambaran umum pola sebaran perjalanan penumpang yang divisualisasikan menggunakan peta digital. Metode yang digunakan dalam pengambilan data adalah passenger interview dengan sampel 100 responden pada Suroboyo Bus Koridor U-S (Purabaya-Rajawali), dan 98 responden pada Koridor TIJ (Terminal Intermoda Joyoboyo-Terminal Osowilangun), dengan pengolahan Matriks Asal Tujuan (MAT), dan pemetaan menggunakan ArcGIS Online hingga menghasilkan web app map. Hasil penelitian dapat disampaikan bahwa origin destination penumpang Suroboyo Bus ditinjau secara umum melalui moda dan jarak tempuh pada masing-masing koridor, menunjukkan fenomena lokasi asal dan tujuan yang paling diminati, sehingga dapat diperoleh rencana pengembangan rute sebagai upaya optimalisasi kinerja Suroboyo Bus, disarankan pada koridor U-S adalah; Sukodono-Taman-Sepanjang-Waru -Wonokromo -Genteng -Tegalsari – Bubutan – Krembangan – Pabean Cantian, dan pada koridor TIJ adalah; Gedangan – Waru – Wiyung – Lakarsantri – Tandes – Benowo.
Evaluasi Kinerja Saluran Drainase di Jalan Semambung – Sumput Kecamatan Driyorejo dengan Hec-RAS Setyawati, Karina Nova; Amudi, Abdiyah
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 5 No 2 (2023): Vol. 5 No. 2 (2023)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v5n2.p141-153

Abstract

Pada Februari 2023, hujan deras mengakibatkan terjadinya genangan dan banjir dengan ketinggian berkisar 30 hingga 80 cm di sepanjang Jalan Semambung – Sumput Kecamatan Driyorejo Kabupaten Gresik. Permasalahan genangan dan banjir yang ada sampai saat ini belum teratasi secara optimal. Penelitian ini bertujuan untuk mengevaluasi kapasitas saluran drainase dalam menampung aliran permukaan untuk mendapatkan solusi penanganan masalah yang ada sebagai rekomendasi kepada pihak yang berwenang. Evaluasi ini dilakukan menggunakan permodelan menggunakan software Hec-RAS dan perhitungan secara manual. Evaluasi yang dilakukan dengan analisis Hec-RAS dan dikontrol dengan analisis manual mendapatkan hasil bahwa kapasitas saluran yang efektif menampung debit aliran yang mengalir hanya terdapat pada section 1 saluran barat, serta section 1 sampai dengan 4 untuk saluran timur. Pada section 2 sampai 10 pada saluran barat serta section 5 sampai dengan 7 pada saluran timur sudah tidak lagi efektif menampung debit aliran sehingga terjadi pelimpahan. Rekomendadi solusi yang disarankan oleh peneliti dalam penelitian ini meliputi metode struktural. Solusi struktural pemeliharaan yang disarankan adalah normalisasi dan perawatan secara berkala terhadap saluran sehingga mengurangi penumpukan sampah serta tanaman liar yang ada dan memperkecil ukuran saluran. Solusi struktural pembangunan yang disarankan meliputi pengubahan dimensi saluran serta lapis permukaan saluran pada section saluran yang tidak efektif.
Pemanfaatan Abu Tempurung Kelapa Sebagai Substitusi Filler pada Campuran Perkerasan Asphalt Concrete – Binder Course Widyastuti, Silviya; Widayanti, Ari
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 5 No 2 (2023): Vol. 5 No. 2 (2023)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v5n2.p134-140

Abstract

Perkembangan dan pertumbuhan penduduk di Indonesia sangat pesat. Seiring dengan hal tersebut berakibat pada meningkatnya mobilitas penduduk di berbagai daerah. Hal ini menimbulkan berbagai jenis kendaraan terutama kendaraan berat yang melintas di jalan raya. Salah satu prasarana transportasi yang berperan penting dalam mobilitas penduduk sehari-hari adalah jalan. Permasalahan sampah di Indonesia juga merupakan masalah yang belum terselesaikan hingga saat ini. Limbah kelapa sangat banyak di Indonesia dan kurangnya dimanfaatkan oleh manusia. Penelitian ini memanfaatkan limbah di Indonesia untuk material jalan, yaitu abu tempurung kelapa yang digunakan sebagai filler dalam campuran aspal beton. Pemakaian limbah abu tempurung kelapa sebagai filler merupakan salah satu alternatif yang diharapkan akan meningkatkan kinerja campuran perkerasan AC BC (Asphalt Concrete – Binder Course). Filler merupakan bahan berbutir halus yang lolos saringan No.200. Penelitian ini bertujuan untuk mengurangi limbah tempurung kelapa, mengetahui pengaruh penggunaan abu tempurung kelapa sebagai filler pada campuran AC-BC berdasarkan karakteristik Marshall. Karakteristik Marshall yang digunakan sebagai campuran AC-BC dengan penambahan filler abu tempurung kelapa pada kadar yang sudah diujikan dengan variasi filler 3,5% dan 4%. Hasil uji Marshall menunjukkan bahwa nilai stabilitas, VMA, dan MQ dapat memenuhi seluruh parameter Marshall yang disyaratkan, sedangkan nilai flow, VIM, dan VFA masih belum memenuhi spesifikasi.
Kajian Laboratorium Sika Viscocrete Pada Beton Normal Menggunakan Agregat Kasar Batu Karang Lukas, Alva Yuventus; Rafael, Jusuf Wilson Meynerd; AR, Zulfiani
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p1-10

Abstract

Coral limestone oleh masyarakat Nusa Tenggara Timur disebut Batu Karang adalah batuan yang tersebar diseluruh Pulau Timor terkhusus wilayah Kupang Barat, namun potensinya tidak termanfaatkan baik untuk kebutuhan industri konstruksi, hanya sebatas bahan pengisi untuk pekerjaan pondasi. Sedangkan superplasticizer adalah aditif yang memiliki efek mengurangi air dan meningkatkan workability campuran beton, sehingga kekuatan beton dapat meningkat. Penelitian yang dilakukan sebelumnya menunjukan 25% batu karang menggantikan kerikil tanpa superplasticizer menghasilkan nilai kuat tekan beton hingga fc’ = 33 Mpa, namun belum adanya data terkait nilai kuat tekan beton yang menggunakan superplasticizer, sehingga diperlukan pengembangan penelitian penggunaan coral limestone, dengan inovasi penambahan superplasticizer. Tujuan penelitian adalah untuk mengetahui kuat tekan beton menggunakan superplasticizer Sika ViscoCrete-3115N serta hubungan pengaruh penambahan superplasticizer yang tepat terhadap nilai kuat tekan beton tersebut. Metode penelitian bersifat experiment laboratorium dengan variasi superplasticizer 0%, 0,3%, 0,5%, 0,8%. Hasil penelitian menunjukan penggunaan Superplasticizer Sika Viscocrete-3115N memberikan peningkatan nilai kuat tekan beton diusia 28 hari sebesar 24,72 Mpa, 25,86 Mpa, dan 26,23 Mpa, namun peningkatannya lebih kecil dari benda uji tanpa menggunakan superplasticizer
Studi Kelayakan Rencana Pengembangan Pembangunan Gedung F Universitas Dr. Soetomo Surabaya Hastono, Klotok Budi; Apriliani, Rizki Astri; Bustamin, Maulidya Octaviani; Kuncaravita, Sekar Ayu
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p18-29

Abstract

Building F Dr. University Soetomo Surabaya has several main functions consisting of a Library Room, Lecturer Room, Classroom and Auditorium which has been established since 1981, so it is necessary to assess the condition of the building as material for further evaluation. The research was carried out with a building survey to review such as carrying out investigations on the building, measuring or checking. The results of the research obtained are, firstly, technical architecture including aspects of comfort, health, safety, Building F, Dr. University. Soetomo has fulfilled all assessment points well. Second, the structural technical test results obtained using the Hammer Test show that the average compressive strength value of concrete in the building structure of building F gives a value below 250 kg/cm2 which is the minimum concrete quality value used in building structures, so this shows that the strength of the concrete is not meets the requirements when used for multi-storey building structures. Third, the technical utility shows that the strong current electrical system functions well and can be operated safely. The main electrical equipment, labels on panels, good and neat electrical installation lines are not well organized, maintenance is needed to tidy up the electrical cable lines.
Redesain Sistem Drainase Area Gedung A,B,C,D,E dan F di Kampus UNITOMO Asid, Nurul Jannah; Zuraidah, Safrin; Susilo, Yunus; Nugroho, Wisnu Abiarto; Ridlwan, Yusuf
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p11-17

Abstract

Gedung A, B, C, D, E, dan F adalah Gedung yang digunakan untuk perkuliahan dan kantor bagi aktivitas dosen dan tendik di Universitas Dr Soetomo. Pada saat terjadi hujan dengan intesitas yang lama sering terjadi banjir. Banjir menyebabkan aktivitas terganggu dan rentan untuk merusak dokumen dan peralatan penting yang ada pada Gedung tersebut. Banjir terjadi karena saluran drainase yang tidak berfungsi dengan baik, beda tinggi lahan yang tidak beraturan, beda tinggi dengan saluran pembuangan yang lebih rendah, sehingga mengakibatkan air cenderung tidak berjalan dan menggenang. Studi ini akan mengkaji saluran drainase yang ada untuk mengetahui kondisi eksisting saluran dilanjutkan dengan analisa hidrologi untuk mengetahui limpasan debit yang harus ditampung, analisa hidrolika untuk menentukan dimensi saluran, dan analisis kontur tanah untuk menentukan arah aliran air. Berdasarkan temuan analisis, penelitian akan didapatkan rencana drainase terbaru dan rekomendasi sumur resapan. Hasil penelitian didapatkan dari 21 Saluran 17 Saluran memiliki dimesi yag tidak bias menampung air limpasan. Perencanaan ulang desain saluran drainase terbuat dari U-Ditch dengan ukuran 0,3 x 0,3 m – 0,5 x 0,7 m. a. Kebutuhan sumur resapan pada area lapangan Gedung f sampai pintu masuk kampus adalah 40 titik dengan ukuran panjang 1,2 m, lebar 1 m dan tinggi 3 m.
Evaluasi Tingkat Pelayanan Jalan Pada Ruas Jalan Desa Gumawang Kecamatan Belitang Kabupaten Ogan Komering Ulu Timur Singgih, Gian; Nisumanti, Sartika; Qubro, Khodijah Al
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p39-44

Abstract

Ruas Jalan Desa Gumawang Kecamatan Belitang Kabupaten Ogan Komering Ulu Timur sebagai Jalan lintas Kota Terpadu Mandiri (KTM) dimana di sekitar daerah tersebut terdapat aktivitas pasar, dan pertokoan di sepanjang ruas jalan tersebut yang memiliki panjang kurang lebih 2 km. Ruas jalan ini sering mengalami kemacetan disebabkan oleh kurangnya kesadaran masyarakat dalam berkendara. Penelitian ini bertujuan untuk mengetahui tingkat pelayanan jalan menggunakan metode MKJI (1997). Dari hasil Analisa Nilai kapasitas dengan rumus Manual Kapasitas Jalan Indonesia 1997 untuk ruas jalan Desa Gumawang Kabupaten Oku Timur pada titik AB sebesar 1927,363 smp/jam , sedangkan nilai kapasitas untuk ruas jalan Desa Gumawang Kabupaten Oku Timur pada titik CD sebesar 1969,262 smp /selai. Dari hasil penelitian juga dapat tingkat pelayanan ruas jalan Desa Gumawang Kabupaten Oku Timur pada titik AB dengan nilai rasio V/C = 0,26 termasuk dalam kategori tingkat pelayanan jalan arteri kelas B, sedangkan pelayanan tingkat ruas jalan Desa Gumawang Kabupaten Oku Timur pada titik CD dengan nilai rasio V/C = 0,12 termasuk dalam kategori tingkat pelayanan jalan arteri kelas A Kata Kunci: Tingkat Pelayanan Jalan ; Kapasitas Jala ; , Ruas Jalan
Analisis Nilai Durabilitas Lataston HRS-WC dan Laston AC-WC menggunakan Material Agregat Bulat pada Pemadatan Sedang Bela, Krisantos Ria
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p30-38

Abstract

Durabilitas campuran aspal merupakan faktor penting dalam menentukan kualitas infrastruktur jalan. Penelitian ini bertujuan untuk menganalisis nilai durabilitas dari campuran beraspal panas, baik Hot Rolled Sheet-Wearing Course (HRS-WC) maupun Asphalt Concrete-Wearing Course (AC-WC), menggunakan agregat bulat pada pemadatan sedang. Metode uji laboratorium dilakukan untuk menguji durabilitas dengan fokus pada parameter Indeks Kekuatan Sisa (IKS), Indeks Keawetan Pertama (IDP), dan Indeks Keawetan Kedua (IDK). Hasil penelitian menunjukkan bahwa penambahan agregat bulat mengakibatkan penurunan nilai IKS pada kedua campuran, hanya nilai Indeks Kekuatan Sisa (IKS) 1 hari dengan variasi pencampuran batu bulat 0% dan 10% yang memenuhi syarat Spesifikasi Bina Marga Tahun 2018 Revisi 2. Selain itu, campuran AC-WC menunjukkan variasi signifikan dalam IDP pada waktu perendaman 48 jam dengan penambahan batu bulat hingga 30%, nilai IDP yang dihasilkan melebihi 1%, menandakan bahwa campuran AC-WC pada kondisi tersebut tidak dapat dianggap durable. IDK menunjukkan kecenderungan penurunan nilai seiring bertambahnya waktu perendaman, menandakan peningkatan kehilangan kekuatan. Kesimpulannya, penggunaan agregat bulat dalam campuran beraspal panas mempengaruhi durabilitasnya, menekankan pentingnya pertimbangan matang dalam penggunaan material untuk meningkatkan kualitas infrastruktur jalan.
Analisis Kestabilan Dinding Penahan Tanah Tower Sutet 500 KV Ungaran – Pemalang Cahyono, Muhammad Shofwan Donny; Darmawan, Kevin Candra; Wibisono, R. Endro; Ningrum, Rina Cahyanti
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p45-50

Abstract

Lereng di T.388 Sutet Ungaran – Pemalang merupakan lereng tanah dengan kedalaman 30 m dan jarak dengan sutet sangatlah dekat, sehingga perlu dilakukan analisis kestabilan lereng pada tanah di Ungaran – Pemalang. Untuk mengetahui faktor keamanan pada lereng serta langkah pencegahan guna menghindari kelongsoran berikutnya yang akan berdampak pada sutet T.388. Jenis Penelitian ini adalah penelitian kasus/lapangan. Dalam memperoleh data teknis peneliti menggunakan metode observasi pada lokasi dan objek penelitian dengan mengamati objek penelitian dan mencatat secara sistematik. Dari beberapa simulasi perkuatan lereng yang dilakukan pada program plaxis ditemukan bahwa kestabilan lereng didapatkan pada nilai 1,78 > 1,5, dimana nilai tersebut dianggap kondisi lereng masih dalam kondisi stabil, perkuatan dengan cara membuat terasiring tanah + DPT dapat menambah kestabilan lereng hingga mencapai 3,19, perkuatan dengan cara menyusun geoteksil secara terasiring + DPT tidak menambah SF daripada lereng tersebut, tetap pada nilai 1,78, perkuatan dengan cara membuat kontur tanah menjadi terasiring + slope + DPT menambah SF daripada lereng tersebut, tetap pada nilai 3,32, perkuatan dengan bore pile 40 cm sedalam 9 m menambah SF daripada lereng tersebut, tetap pada nilai 3,08. Dari beberapa simulasi yang dilakukan, didapatkan kontur tanah yang dibuat terasiring ternyata mampu menambah SF daripada kestabilan lereng tersebut.
Evaluasi Risiko Likuifaksi Berdasarkan Karakteristik Ukuran Butir Tanah dan Hasil Tahanan Standart Penetration test (N-SPT) Studi kasus Bandara Yogyakarta Internasional Airport Diana, Nur Ayu; Soemitro, Ria Asih Aryani; Ekaputri, Januarti Jaya; Satrya, Trihanyndio Rendy; Warnana, Dwa Desa
PUBLIKASI RISET ORIENTASI TEKNIK SIPIL (PROTEKSI) Vol 6 No 1 (2024): Vol. 6 No.1 (2024)
Publisher : Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26740/proteksi.v6n1.p51-58

Abstract

Salah satu bentuk kerusakan pada struktur tanah adalah likuifaksi, di mana tanah berubah dari keadaan padat menjadi cair karena tekanan air pori meningkat dan tekanan efektif tanah menurun akibat beban siklis dinamis. Efeknya bisa sangat signifikan terutama pada tanah berpasir yang sudah jenuh. Penelitian ini bertujuan untuk mengevaluasi kemungkinan likuifaksi berdasarkan data N-SPT serta mengidentifikasi hubungan antara karakteristik tanah dan gempa terhadap risiko likuifaksi. Penelitian dilakukan di area Yogyakarta International Airport (YIA). Metode analisis potensi likuifaksi dimulai dengan menggunakan persamaan dari National Center For Earthquake Engineering Research (NCEER) USA, yang menggunakan data N-SPT untuk menilai potensi likuifaksi secara deterministik menggunakan rasio tahanan siklik tanah (CRR), rasio tekanan siklik beban gempa (CSR), dan koefisien variansi dari kedua rasio tersebut. Hasil analisis menunjukkan bahwa area penelitian memiliki potensi tinggi untuk likuifaksi terdapat pada permukaan tanah hingga pada kedalaman data SPT 15 m . Korelasi antara parameter tanah menunjukkan bahwa peningkatan nilai N-SPT berhubungan dengan peningkatan nilai CRR, namun peningkatan nilai CRR. Selain itu, peningkatan magnitudo gempa berhubungan dengan peningkatan potensi likuifaksi, dimana pada magnitudo gempa 6,5 SR, nilai CRR lebih besar dibandingkan pada magnitudo 7,5 SR dan 8,5 SR. Semakin besar nilai CRR, semakin kecil potensi likuifaksi.