Analysis of Stability and Accuracy of Gas Flow in High Flow Nasal Canule for COVID-19 Patients
Muhammad Ridha Mak'ruf;
Novella Lasdrei Anna Leediman;
Andjar Pudji;
Erwin L. Rimban
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 1 (2023): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/jeeemi.v5i1.277
In December 2019, the world was introduced to a new coronavirus, severe acute respiratory syndrome (COVID-19).The primary strategy for COVID-19 patients is supportive care, using high-flow nasal oxygen therapy (HFNC) reported to be effective in improving oxygenation. Stability is the ability of a medical device to maintain its performance [1]. Medical equipment must have the stability necessary to maintain critical performance conditions over a period of time. Accuracy is the closeness of agreement between the value of a measuring quantity, and the value of the actual quantity of the measuring quantity[2].The purpose of this study is to ensure that the readings of the HFNC device are accurate and stable so that it is safe and comfortable when used on patients. The development of the equipment that will be used by the author adds graphs to the TFT LCD to help monitor stable data in real time so that officers can monitor the flow and fraction of oxygen in the device to be stable. This study uses Arduino Nano while the sensor used is the GFS131 sensor, then the results are displayed on the Nextion TFT LCD. The test is carried out with comparing the setting value of the HFNC tool that appears on the TFT LCD with a gas flow analyzer with a measurement range of 20 LPM to 60 LPM 5 times at each point. Based on measurements on the gas flow analyzer, the HFNC module has an average error (error (%)) of6.40%. Average uncertainty (Ua) 0.05. Conclusion from these results that the calibrator module has a relative error (error value) that is still within the allowable tolerance limit, which is ±10%, the tool is precise because of the small uncertainty and good stability of the stability test carried out within a certain time.
Monitoring the Occurrence of Alarms in High Flow Nasal Cannula (HNFC) Using IoT-Based Thinger.io Platform for COVID-19 Isolation Room
Sapty Taurisita Fauziah;
Muhammad Ridha Mak'ruf;
Andjar Pudji;
Levana Forra Wakidi;
Faraz Masood
Jurnal Teknokes Vol 16 No 1 (2023): March
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/teknokes.v15i4.496
Covid-19 has become a virus that has become a world pandemic and this virus has caused mass deaths because medical personnel have difficulty treating patients when oxygen levels in the blood have fallen to critical levels. HFNC (High Flow Nasal Cannula) is a method of administering additional oxygen to patients with acute respiratory failure. The use of HFNC in recent years has been highly recommended as a solution to provide supplemental oxygen to patients. Administration of HFNC to COVID-19 patients begins at a flow range of 30-60 LPM.Unfortunately, HFNC, which used to exist, can only be monitored manually, resulting in the transmission of HFNC-produced aerosols between patients and staff. So this study aims to analyze errors in HFNC that cause a decrease in flow to HFNC using a flow sensor as a sensor to detect leaks or other flow errors from the HFNC output hose and monitor if there is a blockage through IoT in the form of notifications.This research method uses the Pre-experimental with the After Only Design type. In this design, the researcher only used one group of subjects and only looked at the results without measuring and knowing the initial conditions, but there was already a comparison group. The independent variable in this study was the HFNC error condition. While the dependent variable in this study is the data flow read by the sensor, where IoT notifications and device status show error leaks. The sensors used in this research are MPX5700GP pressure sensors and SEN0343 Differential Pressure sensors as flow sensors. The benefit of this research is that in addition to reducing the burden on medical staff in handling Covid-19 patients, it can also minimize transmission between staff and patients caused by high aerosol production by this HFNC device, this is because HFNC device alarm monitoring can be monitored in the nurse's room via internet technology. In conclusion, to obtain maximum benefits from this research, it is necessary to select a sensor that truly has a high enough resistance to humidity produced by this HFNC humidifier's water vapor.
Monitoring the Occurrence of Alarms in IoT-Based HFNC With Analysis of Signal Increase Before Blockages Error Occurs (Pressure Parameters)
Dwi Widyaningtyas;
Andjar Pudji;
Muhammad Ridha Mak'ruf
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/teknokes.v16i2.456
The workload of medical personnel in handling COVID-19 is quite high due to limited personnel so that medical personnel who are resting are assigned the task of always being ready to carry out clinical monitoring of the use of HFNC. HFNC (High flow Nasal Cannula) is a method of giving supplemental oxygen to patients experiencing acute respiratory failure. The use of HFNC in recent years is highly recommended as a solution to provide additional oxygen to patients. The administration of HFNC to COVID-19 patients begins in the flow range of 30-50 LPM with an oxygen concentration of 92%. This study aims to analyze the error in HFNC which causes a decrease in the flow of HFNC. This study used data collection 10 times by modifying the HFNC output interval. The independent variable in this study is the HFNC error condition. While the dependent variable in this study is the pressure data read by the pressure sensor. In this study using a temperature setting of 34oC with a flow setting of 30-60 LPM. At the flow setting of 30 LPM, the average pressure value before error is 0, in process 2 and after error 0, where the IoT notification and the condition of the tool show a Blockage error. At the flow setting of 30 LPM, the average pressure value before error is 0, in process 1 and after error 0, where the IoT notification and the condition of the tool show a leaking error. In this study, the average error in the conditions of Blokage 3.8 and Leaking 1.5 The shortcomings in this study are can be a pressure sensor which has more sensitive results and also a pressure sensor that has a medical grade standard.
Analysis Of Early Warning System In Cold Room Vaccine Storage With Iot System
Aprilina Gayuh Arniningtyas;
Andjar Pudji;
Endro Yulianto;
Latafat Mikayilzade Ali
Jurnal Teknokes Vol 16 No 2 (2023): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/teknokes.v16i2.487
Cold room as a cold room for vaccine storage is an environment with a controlled temperature used to maintain and distribute vaccines in optimal conditions. To maintain the vaccine, it is necessary to pay attention to routine temperature monitoring, temperature data management, and prevention of situations that endanger the vaccine. The results of this review are expected to be a reference for researchers and readers with the development of research using the DS B1820 temperature sensor which will analyze the results of the data logger output and linearity at sensitive locations Cold Room with LCD output and equipped with an IoT system web display on a PC for monitoring and alarm. and notification via telegram when there is a change in temperature approaching and outside the range of 2 - 8 ° C so that this can make it easier for officers to monitor the temperature and quality of the vaccine. In the results of the study, temperature graphs and temperature data can be displayed which are recorded in minutes. Temperature measurement with standard tools produces the largest difference of 0.83. The lowest temperature was 2.06℃ and the highest temperature was 8.31℃ as well as telegram notification of early warning (2.58℃), evacuation vaccine (2.31℃), and exposed vaccine (8.6℃).
Experimental Measurement and Analysis: Collimation and Illumination for Conformity Measuring Instrument Design in X-ray Modality
Fathul Fajar;
Muhammad Ridha Makruf;
Andjar Pudji;
Achmad Rizal
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v5i2.273
Each radiology or X-ray device is required to perform a functional or performance test of an X-ray aircraft in accordance with the radiation safety standards of the International Nuclear Energy Agency (IAEA). The suitability test has several parameters and parts. In the X-ray Aircraft Suitability Test, there are X-ray beam collimation tests, X-ray generators and tubes, and AEC. However, the illumination and collimation test still uses the manual method. The purpose of this research is to develop the simplest method, which is to measure the illumination at four points simultaneously and store the measurement data directly. This module is designed to use the HC-SR04 sensor as a distance meter and the TSL2561 sensor as a light meter. This module is designed using the HC-SR04 sensor as a distance meter and TSL2561 sensor as a lux meter. In this research, the module has been tested and compared with the results of a comparison tool (Digital Light Meter) and got an error value of 1.55% with a module efficiency of 98.45% in the illumination test, and an error of 1.8% with a module efficiency of 98.2% in the collimator test. From this research, it can be concluded that the light sensor TSL2561 can be used to measure the illumination area of the collimator lamp. The contribution of this research is expected to be more efficient tool testing, and the data will be saved until the next testing time
Comparative Analysis of Water and Oil Media on Temperature Stability in PID Control-Based Digital Thermometer Calibrator
Mochammad Sofyan;
Syaifudin Syaifudin;
Andjar Pudji;
Anggara Trisna Nugraha;
Bedjo Utomo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v5i2.274
Digital thermometers are measuring instruments needed to perform temperature measurement actions and must be calibrated periodically according to standard measurement methods. The purpose of developing this tool is to add PID control to the calibration media where PID control aims to regulate the stability of the temperature setting to be achieved. This is achieved by studying and evaluating the effect of temperature stability on the heater and LM35DZ temperature sensor. This research method uses the Arduino Nanosystem for data processing and PID system control. The LM35DZ temperature sensor on the heater is regulated by a 2 Channel SSR module using a PID system then the temperature generated by the heater will be read by the LM35DZ and displayed on the LCD. The results of this study, digital thermometer calibrator measurements have been successfully carried out by comparing 3 digital thermometers with different brands, namely Omron 343F, Omron 245, and ThermoOne. The difference in error values in oil media is 3-4% and in water media 2-4% with the value of time stability in water media for 3-3.3 minutes and in oil media for 1-2 hours. With this comparison of calibration media, it is hoped that it can help in measuring temperature with better and more effective results. find methods, results, conclusions.
Analysis of Flatness and Alignment in the Design of Wireless X-Ray Conformance Test Tool.
Aska Putri Hermawan;
Andjar Pudji;
Muhammad Ridha Mak’ruf
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v5i2.275
A surface's verticality or horizontalness can be determined as well as its flatness using a waterpass or spirit level. The alignment and flatness of the X-ray tube and bucky table, which determine the perpendicularity of the X-ray beam, is one of the factors for the Conformance Test, according to PERKA BAPETEN No. 2 of 2018. A traditional waterpass is typically used to obtain that conclusion, but the measurement outcome is still subject to human error because there is no set value. To achieve exact alignment, A digital waterpass using the MPU6050 sensor is made, which produces precise X-Ray images, reduces noise in the form of shadow magnification, and investigates the function of the waterpass in the compliance of the X-Ray unit. Arduino is used as the data processor in this investigation. The output is then shown on an LCD and transmitted over Bluetooth to a computer where it is displayed using Delphi before being saved in Excel. With the deviation standard value of 10 degrees, we have obtained an error value from this research between 2% and 3%, minimum, which is 0.04 for sensor 1 and 0.25 for sensor 2. Sensors 1 and 2 measure 14 degrees at 0.089 and 0.054, respectively. The MPU6050 sensor can be utilized in this study to determine how flat the X-Ray tube and bucky table are about one another. This study's contribution is anticipated to be more effective tool testing, and the data will be kept on file until the next testing session.
Anc Bed For Preeclamsi Early Detection Using Web System
Fiqih Fahrur Ramadhan;
Andjar Pudji;
Muhammad Ridha Mak’ruf;
Shubhrojit Misra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 3 (2023): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v5i3.288
One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. One of the efforts that can be made to improve services for pregnant women is with a web-based ANC examination. The purpose of this study is to analyze NIBP and BMI data sent and received by IoT media so that they are useful for the diagnostic process. The contribution of this research is knowing the response of NIBP and BMI data sent and received via IoT media. The procedure for achieving this goal is with the MPX5050 sensor and Loadcell whose output will be processed and displayed on a web page. From this study it can be concluded that the sending of IoT-based NIBP and IMT data affects lost data or delays received. The findings from this study are expected to be developed in further research. So that it can be said that the use of the ESP32 module as the delivery of ANC BED inspection results resulted in no loss of data found in sending ANC inspection results with 100% data results being sent without any data loss and delay with an average of 2 seconds.
ECG and NIBP Simulators in One Device Display on TFT Nextion
Cantika Melinda;
I Dewa Gede Hari Wisana;
Andjar Pudji;
Triwiyanto Triwiyanto
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 3 (2023): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ijeeemi.v5i3.293
Accurate monitoring of NIBP (Non-Invasive Blood Pressure) parameters using vital sign monitors is crucial for patient care. Therefore, calibration of vital sign monitors is essential to ensure their safety and reliability. The purpose of this study is a vital sign simulator was developed, integrating ECG and NIBP parameters with a TFT Nextion display, to calibrate ECG and NIBP readings on vital sign monitors. The system utilized the Arduino Mega 2560 as the central controller and the MPX5050GP sensor for NIBP measurement and motor pump control. The NIBP parameters were measured at two settings: 60/30 and 80/50. The results showed a maximum systolic error of 3.5% and a diastolic error of 5.6% for the NIBP setting of 80/50. The largest standard deviation value of 2.05 was observed at the NIBP setting of 60/30. The highest uncertainty value of 0.5 was also found in the NIBP 60/30 setting. The obtained data indicated stable module readings within the acceptable threshold for vital sign monitor calibration. The developed vital sign simulator offers a reliable means of calibrating NIBP parameters, enabling accurate blood pressure measurements. Further research and refinement can be conducted to enhance the system's precision and expand its capabilities for calibration of additional vital sign parameters. By ensuring accurate calibration, healthcare professionals can rely on vital sign monitors for effective patient monitoring and diagnosis.
Educational for Technical Personnel of Krembangan Health Center in order to increase Awareness on Leakage Current Measurement for Medical Equipment and Patient Safety
Ridha Makruf, Muhammad;
Priyambada Cahya Nugraha;
Pudji, Andjar
Frontiers in Community Service and Empowerment Vol. 3 No. 4 (2024): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.35882/ficse.v3i4.85
The electrical safety of medical equipment is crucial to prevent hazards that endanger both healthcare workers and patients. Krembangan Health Center faces significant challenges due to staff's limited knowledge about electrical safety, including leakage current detection. The aim of this study was to enhance staff skills in ensuring electrical safety through a focused training program. The program covered the basics of electrical safety, leakage current risks, and practical use of a digital multimeter for inspections. Field surveys and practical training were conducted to inspect and measure electrical systems across the health center. Results revealed inadequate grounding, uneven load distribution, and leakage voltage up to 99 volts AC in the new building, while the old building had minor leakage issues. The conclusion emphasized the need for regular maintenance, comprehensive electrical safety audits, and ongoing staff training to ensure long-term safety. These efforts aim to create a safer healthcare environment, improving the reliability of medical equipment and safeguarding patient care.