Design of Vital Sign Monitor with ECG, BPM, and Respiration Rate Parameters Gede Aditya Mahendra Oka; Andjar Pudji
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i1.6

Abstract

Vital sign monitor is a device used to monitor a patient's vital sign, in the form of a heartbeat, pulse, blood pressure, temperature of the heart's pulse form continuously. Condition monitoring in patients is needed so that paramedics know the development of the condition of inpatients who are experiencing a critical period. Electrocardiogram (ECG) is a physiological signal produced by the electrical activity of the heart. Recording heart activity can be used to analyze how the characteristics of the heart. By obtaining respiration from outpatient electrocardiography, which is increasingly being used clinically to practice to detect and characterize the abnormal occurrence of heart electrical behavior during normal daily activities. The purpose of this study is to determine that the value of the Repiration Rate is taken from ECG signals because of its solidity. At the peak of the R ECG it has several respiratory signals such as signals in fluctuations. An ECG can be used to determine breathing numbers. This module utilizes leads ECG signals to 1 lead, namely lead 2, respiration rate taken from the ECG, BPM in humans displayed on a TFT LCD. This research module utilizes the use of filters to obtain ECG signals, and respiration rates to display the results on a TFT LCD. This module has the highest error value of 0.01% compared to the Phantom EKG tool. So this module can be used for the diagnosis process.ECG, Respiration Rate, Filter
Design an Infusion Device Analyzer with Flow Rate Parameters using Photodiode Sensor Andjar Pudji Pudji; Anita Miftahul Maghfiroh; Nuntachai Thongpance
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.1

Abstract

Infusion devices are the basis for primary health care, that is to provide medicine, nutrition, and hydration to patients. One of the infusion devices is a syringe pump and an infusion pump. This device is very important to assist the volume and flow that enters the patient's body, especially in situations related to neonatology or cancer treatment. Therefore, a comparison tool is needed to see whether the equipment is used or not. The purpose of this research is to make an infusion device analyzer (IDA) design with a flow rate parameter. The contribution of this research is that the tool can calculate the correct value of the flow rate that comes out of the infusion pump and syringe pump. The water released by the infusion pump or syringe pump will be converted into droplets which are then detected by the sensor. This tool uses an infrared sensor and a photodiode. The results obtained by the sensor will come by Arduino nano and code it to the 16x2 Character Liquid Crystal Display (LCD) and can be stored on an SD Card so that it can be analyzed further. In setting the flow rate for the syringe pump of 100 mL / hour, the error value is 3.9, 50 ml / hour 0.02, 20 mL / hour 0.378, 10 mL / hour 0.048, and 5 mL / hour 0.01. The results show that the average error of the syringe pump performance read by the module is 0.87. The results obtained from this study can be implemented for the calibration of the infusion pump and the syringe pump so that it can be determined whether the device is suitable or not
Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode Vanda Catur Kirana; Dwi Herry Andayani; Andjar Pudji
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.6

Abstract

The uneven distribution of the baby incubator temperature can cause the temperature in the baby incubator to be different at each point. The purpose of this study was to analyze the effect of the door closed and opened to the temperature at each point of sensor placement that has been determined. The study was conducted as an experimental research design. In this experiment, an Incu Analyzer comparison was used as a calibrator unit, a baby skin temperature thermistor sensor, and four LM35 sensors for baby incubator room temperature with one LM35 sensor as a PID control system carried out by trial-and-error method. Based on the results of measurements was made with the design, when the chamber is open, it produces an average error value of T1 4.083%, T2 6.06%, T3 3.78%, T4 4.88%, and T5 1.48%, while when the chamber is closed, it produces an average error value T1 0.75. %, T2 0.88%, T3 1.15%, T4 0.74%, and T5 0.87%. Measurement of skin temperature using a thermometer has an average error value of 1.1%. The results showed that uneven heat transfer, lack of air distribution, different sensor placements at each point, and non-standard chamber sizes were factors that were uneven at each point. Based on the results of the study, it was found that the use of a working system on this device can be implemented to control the temperature of the baby incubator by knowing the temperature distribution at each point
A Modified Electrosurgery Unit Based on High Frequency Design with Monopolar and Bipolar Method Edo Rafsanzani; Tri Bowo Indrato; Andjar Pudji; Shengjie Yan; Sergey A. Bogavev
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 4 (2021): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i4.1

Abstract

Electrosurgery Unit is some machine to human body surgery. Electrosurgery Unit is uses a high frequency to human body tissue surgery, that causes blood who came out can be dicrease during surgery. When using a conventional scalpel is something that is highly avoided because it will cause contraindications to lack of blood which will be very dangerous for the patient. The purpose of this study is to design a tool that is used to replace a conventional scalpel with a tool that utilizes high frequency (400 KHz) generated by the oscillator circuit. In this study. The researches used Monopolar method and used two modes Cutting and Coagulation in order to eliminate faradic effects on body tissues causes high frequency, there is the high frequency will be adjusted to the duty cycle which aims to obtain various types of surgery required by doctor which is cutting 100% on and coagulation 6% on 94% off where is set it with arduino program. In this study, the researchers took advantage of the type of heat effect produced by high frequencies which were concentrated at one point so that it could be used to carry out the process of surgery on body tissues so as to minimize the occurrence of large blood loss. The result of this study is will be centered at one point on an object there is show up the depth difference of the cutting mode and the wide large difference of the coagulation mode. The module design resulted the power lowest at 300Ohm ESU Analyzer setting is 30Watt and the highest at 300Ohm setting too is 68Watt. The module design resulted the power lowest at 300Ohm ESU Analyzer setting is 30Watt and the highest at 300Ohm setting too is 68Watt at mode Cutting and the highest and lowest Coagulation mode using impedance setting the same there is 300 Ohm is constant 3Watt power result’s. The weaknesses at this research is the power still lower then the Electrosurgery Unit where is in the hospital. It can be fix for the next research using increase the final amplifier and maybe increase the frequency where is gonna make the voltage of the final amplifier be much better then this research
Analysis of Changes in Flow Setting Against Rise Time Using Gas Board 7500E Sensor on Bubble CPAP Andjar Pudji; Farid Amrinsani; Sari Luthfiyah; Lusiana Lusiana; Shubhrojit Misra; Nur Hasanah Ahniar; Yenda Mita Barus; Lamidi Lamidi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.8

Abstract

Respiratory distress in neonates is one of the biggest problems encountered on a daily basis. Respiratory distress looks like rapid breathing in a newborn. CPAP Bubble is the right treatment in this case. Rise time is the time for airway pressure to reach the maximum standard value. A fast time value can make it possible to bring the breath pressure to a standard level. This study aims to analyze changes in setting flow to rise time using a gasboard sensor 7500E on a CPAP bubble device. The main advantage of this proposed method is that the results are displayed in the form of graphics, portable and there is data storage. This design uses a Gasboard 7500E sensor as a detector of oxygen concentration, a TFT LCD as a graphic display and an SD Card as data storage. The data collection is in the form of the average rise time of oxygen concentration followed by changes in its rate. Data were taken five times with three different CPAPs. The results showed that the increase in the rate affect the rise time of the CPAP oxygen concentration.
Analysis of Temperature Stability and Accuracy on the Design of Thermometer Calibrator Based on Fuzzy Logic And On/Off Control Yunik Pujiastuti; Andjar Pudji; Singgih Yudha Setiawan; Farid Amrinsani; Khongdet Phasinam
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 3 (2022): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i3.244

Abstract

A thermometer is a medical device used to measure body temperature. To maintain the accuracy of the thermometer measurement results, periodic calibration is required. Calibration is an activity to determine the conventional correctness of the indicator values of measuring instruments and measuring materials by comparing them with measurement standards that can be traced to national and international standards for units of measure and/or international and certified reference materials. Based on the results of the identification of chronological problems that have been observed, a body thermometer that measures body temperature is needed so and a calibrator is needed to maintain the accuracy of the thermometer. The purpose of this study was to analyze the Temperature Stability and Accuracy of the Body Thermometer Calibrator Based on on-Off Control and Fuzzy Logic Control. The contribution of this research to this tool will use the development of a fuzzy logic control method to produce temperature stability in the Body Thermometer Calibrator (Digital). The method used in this study used fuzzy control and on-off control. The results of this study from the suitability test obtained a maximum error of 0.2% in the fuzzy control and 0.6% in the On-Off control. The average rise time difference for the two controls was 13.53 Seconds. The average settling time difference is 130.46 seconds. The results of this study can be concluded that the Fuzzy System is better than the On / Off system so the Fuzzy system is more suitable for thermometer calibration media.
ECG Simulator Based on Microcontroller Equipped with Arrhythmia Signal M. Ridha Mak'ruf; Andjar Pudji; Bedjo Utomo; I Dewa Gede Hari Wisana; Torib Hamzah; Lamidi Lamidi; Denis Kurniar Wicaksono; Sedigheh Ashgari Baighout
Jurnal Teknokes Vol 15 No 2 (2022): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v15i2.244

Abstract

Electrocardiograph (ECG) is one of the diagnostic sciences that is often studied in modern medicine, used to detect damage to the components of the heart or disorders of the heart rhythm called arrhythmias. The purpose of this research is to develop an Electrocardiograph simulator that is equipped with arrhythmia. The main design consists of an Arduino Mega 2560 microcontroller, MCP4921 DAC (Digital to Analog Converter) circuit, a network resistor, and a sensitivity selection circuit. The MCP4921 type DAC converts the digital signal data into analog data which will then be forwarded to the resistor network circuit as a signal formation for each lead. The basic signal image data used for the formation of normal Electrocardiograph and arrhythmias were taken from the Electrocardiograph recorder using Phantom Electrocardiograph. Based on the readings on the Beat Per Minute setting of the module to the Beat Per Minute printout on the Electrocardiograph recorder, the error rate value for the Normal Sine Rhythm parameter is 0.790% for Beat Per Minute 30, 0.383% for Beat Per Minute 60, 0.535% for Beat Per Minute 120, 0.515% for Beat Per Minute 180 and 0.593% for Beat Per Minute 240. The error rate for the Arrhythmia parameter is 2.076% for ventricular tachycardia Beat Per Minute 160 and 0.494% for Supraventricular Tachycardia Beat Per Minute 200. The design of the Electrocardiograph simulator can simulate the signals of the human body and it can be used as a medium in the learning process in the world of health
The Effect of Lost Data on the IoT Platform on the Formation of Fetal Heart Rate Graphs for Remote Diagnostic Purposes Boy Pribowo; Andjar Pudji; Muhammad Ridha Mak’ruf; Vugar Abdullayev
Jurnal Teknokes Vol 15 No 4 (2022): December
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v15i4.489

Abstract

FHR is the fetal heart rate from bpm recording detected by doppler, FHR monitoring is very important to monitor fetal health to avoid fetal distress or fetal death, FHR provides more in-depth information about how the baby is doing compared to traditional monitoring of the baby. IoT media is a medium for monitoring remote sensor values ​​using internet connections, but there are several obstacles, namely there are doubts about the data displayed by IoT media, namely the risk of missing or unsent data, this will be very dangerous if the data that is should be monitored by doctors as a reference for medical diagnosis and treatment is lost or not displayed on the IoT, because if there is missing data it will cause inaccurate diagnosis or health treatment decisions by doctors. The aim of this study to analyze the effect of lost data on the formation of the Fetal Heart Rate graph on the IoT platform as a medium for remote diagnosis. In addition, FHR data can be saved for further diagnosis by a doctor if needed. This study uses an ESP32 microcontroller which will also be used to send data to IoT (Thinger.io). The independent variable used in this study is FHR data before it is uploaded to the IoT, and the dependent variable is FHR data when it is uploaded to the IoT. The greatest data loss is at the farthest distance of 30 meters with a value of 62.47%. Based on the research that has been done, this study has the advantage that the results obtained from Doppler are close to the BPM value in humans. And also this research has developments that can be done in the future such as adding storage to the website that is used for monitoring, and placing the right position on Doppler so that the results are more stable.
QRS Complex Detection On Heart Rate Variability Reading Using Discrete Wavelet Transform Arga Wihantara; I Dewa Gede Hariwisana; Andjar Pudji; Sari Luthfiyah; Vijay Anant Athavale
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.236

Abstract

Heart Rate Variability or heart rate in humans is used to monitor the heart rate in humans, the function of the heart rate monitor is to monitor the human heart rate. The purpose of making this tool is to compare the results of heart rate readings using the discrete wavelet transform method to facilitate the detection of R peak. This can be learned by evaluating and studying each decomposition result from level 1 to level 4 on Discrete Wavelet Transform processing using Haar mother wavelets. This study uses a raspberry pi 3B as a microcontroller as a data processor that is obtained from the ECG module. From this study, it can be concluded that in heart rate readings, level 2 decomposition details coefficient has the best value as data processing that helps for heart rate readings with an error value of 0.531%, HRV readings of 0.005 in comparison with phantom tools and a standard deviation of 0.039. The advantage of this tool is a good precision value in HRV and BPM readings. In reading the HRV of the respondent, it was found that each initial condition of the patient's HRV would be high due to the respondent's unstable condition. The disadvantage of this tool is that there is a delay in running the program, there is no display in the form of a signal in real time.
A Analysis of The Capture Result of Flat Panel Detector Design with Arduino-Based BPW34 Photodiode Sensor against mA and kV Settings Muhammad Rois Amin; Muhammad Fajar Wahyudi; Muhammad Ridha Makruf; Tri Bowo Indrato; Andjar Pudji; Satheeshkumar Palanisamy
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 3 (2022): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i3.242

Abstract

The exposure factor is the factor that determines the intensity and quality of X-rays received by the patient. Exposure factors that can be controlled are: tube voltage (kV), tube current (mA), irradiation time (second), and distance of the X-ray tube to the film (FFD). The purpose of this study was to capture X-rays at a relatively affordable manufacturing price and to obtain a difference in value from the detector's catch between dark and light by utilizing the response of the BPW34 photodiode sensor. The contribution of this study is that the system can display grayscale and numerical on an 8x8 pixel matrix using the Matrix Laboratory (MATLAB) Application. This study was able to convert images taken from analog data after taking measurements on X-rays. The measurements are carried out by 2 methods, there are range used was 32-63mA, with a tube voltage of 50 kV at an irradiation duration of 1 second and 50 - 70 kV, with a tube current of 40 mA and an irradiation duration of 1 second. From the measurement results, it shows that the Flat Panel Detector Design Tool after being compared with the Philips brand DR is able to respond to differences in dose and object thickness. The results of this study indicate that this tool can be used to capture X-rays so that the degree of blackness of the film can be known.
Co-Authors Achmad Rizal Achmad Rizal Ahmad Fanani Ahmad Fanani Ahmad Zaky Ma'arif Ahniar, Nur Hasanah Alfina Nadhirotussolikah Ali, Latafat Mikayilzade Alievya Brillianty Anugrah Kusuma Amrinsani, Farid Andayani, Dwi Herry Anggara Trisna Nugraha Anita Miftahul Maghfiroh Aprilina Gayuh Arniningtyas Arga Wihantara Arniningtyas, Aprilina Gayuh AskA Putri Hermawan Aulia, Farahun Nisa Bambang Guruh Irianto Barus, Yenda Mita Bogavev, Sergey A. Boy Pribowo Cantika Melinda Denis Kurniar Wicaksono Des, Sima Dwi Herry Andayani Dwi Herry Andayani Dwi Widyaningtyas Edo Rafsanzani Endro Yulianto Erwin L. Rimban Fajar, Fathul Faraz Masood Fathul Fajar Fauzi, Ekha Rifki Fiqih Fahrur Ramadhan Forra Wakidi, Levana Gede Aditya Mahendra Oka Hermawan, Aska Putri I Dewa Gede Budi Whinangun I Dewa Gede Hari Wisana I Dewa Gede Hariwisana I Dewa Gede Hariwisana Ichwan Syahrul Bahtiar Indrato, Tri Bowo Indrato, Tri Bowo Khongdet Phasinam Kirana, Vanda Catur Laily Nurrohmah Lamidi, Lamidi Latafat Mikayilzade Ali Liliek Soetjiatie Lizarazu Maulidil Li Kharis Lusiana Lusiana Lusiana Lusiana Luthfiyah, Sari M. Ridha Mak'ruf M. Ridha Makruf Mak’ruf, Muhammad Ridha Melinda, Cantika Misra, Shubhrojit Mochammad Sofyan Mohamad Adam Firdaus Mufarid, Muhammad Nezar Abdullah Muhammad Fajar Wahyudi Muhammad Nezar Abdullah Mufarid Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Makruf Muhammad Ridha Mak’ruf Muhammad Ridha Mak’ruf Muhammad Ridha Mak’ruf Muhammad Rois Amin Novella Lasdrei Anna Leediman Nuntachai Thongpance Oka, Gede Aditya Mahendra Oka, I Komang Yogi Mahardika Priyambada Cahya Nugraha Rafsanzani, Edo Ramadhan, Fiqih Fahrur Rizhky, Ayu Nissa Berlianri Sapty Taurisita Fauziah Satheeshkumar Palanisamy Sedigheh Ashgari Baighout Sergey A. Bogavev Setiawan, Singgih Yudha Shengjie Yan Shubhrojit Misra Shubhrojit Misra Sofyan, Mochammad Sumber, Sumber Syaifudin Syaifudin Syaifudin, Syaifudin Thongpance, Nuntachai Torib Hamzah Triwiyanto Triwiyanto Ullah, Naqeeb Utomo, Bedjo Vanda Catur Kirana Vijay Anant Athavale Vugar Abdullayev Widyaningtyas, Dwi Yan, Shengjie Yenda Mita Barus Yunik Pujiastuti