Claim Missing Document
Check
Articles

Central Monitor Based Personal Computer with SpO2 and Body Temperature Parameters Via Wireless Xbee Pro Oka, I Komang Yogi Mahardika; Pudji, Andjar; Mak’ruf, Muhammad Ridha
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 2 No. 1 (2020): February
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i1.258

Abstract

Central patient monitor that is not real-time and continues will cause inaccuracies monitoring results and also sending data that is still using cable will cause limited distance. The purpose of this research is to design a central monitoring based personal computer via Xbee Pro. The contribution of this research is, the system works in real-time and continues, more parameters, using wireless, longer transmission distances. So that monitoring can be done in real-time and continue via wireless with more distance, then the wireless system uses the Xbee Pro module which has larger output power and uses the same number of wireless modules between transmitter and receiver. Body temperature was measured using the LM35 sensor and oxygen saturation in the blood was measured using the MAX30100 sensor. Data is sent using Xbee Pro and displayed on a personal computer. At the distance of receiving data approximately 25 meters with a wall divider, obtained results of smooth monitoring without any loss of data. The results showed that the average SpO2 error value was 0.34% in module 1 and 0.68% in module 2. The average value of body temperature error was 0.46% in module 1 and 0.72% in module 2. The results of this research can be implemented in a centralized patient monitoring system at the hospital, making it easier for health workers to monitor multiple patients, with the results of monitoring in real-time and continue, more parameters, via wireless with greater distance.
TRAINING OPERATION AND MAINTENANCE OF FETAL DOPPLER TO MAINTAIN THE HEALTH OF MOTHERS AND CHILDREN AT THE COMMUNITY HEALTH CENTER IN THE SOUTH KREMBANGAN, SURABAYA: TRAINING OPERATION AND MAINTENANCE OF FETAL DOPPLER TO MAINTAIN THE HEALTH OF MOTHERS AND CHILDREN AT THE COMMUNITY HEALTH CENTER IN THE SOUTH KREMBANGAN, SURABAYA Ridha Makruf, Muhammad; Pudji, Andjar
Frontiers in Community Service and Empowerment Vol. 4 No. 4 (2025): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v4i4.113

Abstract

This community service activity focuses on counseling and training related to the operation and maintenance of fetal Doppler devices as an effort to improve maternal and child health services in the South Krembangan Village area, Surabaya. Fetal Doppler is a critical medical device used to monitor fetal heart rate and ensure the well-being of the fetus during pregnancy. However, its effectiveness greatly depends on the users' knowledge and skills, particularly among midwives and health workers at Community Health Centers (Puskesmas). The activity involved structured training sessions combining theoretical explanations and practical demonstrations, aiming to enhance participants’ understanding of safe device operation, routine maintenance procedures, and early detection of equipment malfunctions. The results showed increased competency among participants in both operating the device and performing basic troubleshooting. This initiative not only supports the continuity of quality antenatal care but also strengthens local health capacity in the effort to reduce maternal and infant morbidity and mortality. Continuous follow-up and evaluation are recommended to sustain the impact of the program.
QRS Complex Detection on Heart Rate Variability Reading Using Discrete Wavelet Transform Arga Wihantara; I Dewa Gede Hari Wisana; Andjar Pudji; Sari Luthfiyah; Vijay Anant Athavale
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.159

Abstract

Heart Rate Variability or heart rate in humans is used to monitor the function of the human heart. This research designed a tool to compare the results of heart rate readings using the discrete wavelet transform method to facilitate the detection of R peak. This can be obtained by evaluating and studying each decomposition result from level 1 to level 4 on Discrete Wavelet Transform processing using Haar mother wavelets. This study further used a raspberry pi 3B as the microcontroller of the data processor obtained from the ECG module. Based on the results obtained in this study, it can be concluded that in heart rate readings, level 2 decomposition details coefficient had the best value as data processing that helps the heart rate readings with an error value of 0.531% compared to HRV readings that obtained 0.005 using phantom tools and a standard deviation of 0.039. Furthermore, the advantage obtained from this tool is a good precision value in HRV and BPM readings. In reading the HRV of the respondent, it was found that each initial condition of the patient's HRV would be high due to the respondent's unstable condition. The disadvantage of this tool is a delay in running the program and no display in the form of a signal in real time.
Training on The Operation And Maintenance Of Ultrasonography (USG) Equipment For Healthcare Workers to Improve Diagnostic Services at Community Health Centers in South Krembangan Surabaya Muhammad Ridha Makruf; Andjar Pudji; Priyambada Cahya Nugraha; I Dewa Gede Hariwisana
Frontiers in Community Service and Empowerment Vol. 5 No. 3 (2026): September
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Ultrasonography (USG) is one of the most widely used diagnostic imaging modalities because it is non-invasive, free from ionizing radiation, relatively affordable, and capable of providing real-time anatomical information. In primary healthcare facilities (Puskesmas), USG has become increasingly important, particularly for maternal health services, abdominal examinations, and early disease screening. However, many healthcare workers have limited competence in operating USG equipment and performing routine maintenance, resulting in suboptimal utilization of available equipment. This community service program aimed to improve the knowledge and practical skills of healthcare workers regarding the proper operation and preventive maintenance of Ultrasonography (USG) equipment. The activity employed an educational-participatory approach consisting of lectures, demonstrations, hands-on practice, discussions, and evaluations using a one-group pretest-posttest design. Fifteen healthcare workers, including general practitioners, midwives, nurses, and electromedical technicians, participated in the training. The average knowledge score increased from 61.8 during the pretest to 90.7 after the training, representing a 46.8% improvement. Practical competency evaluation showed that 80% of participants reached the "Excellent" category, while the remaining 20% were classified as "Good." Participants expressed high satisfaction with both the theoretical and practical components of the training. The training significantly improved participants' competence in operating and maintaining USG equipment, thereby supporting the enhancement of diagnostic services at primary healthcare facilities.
Development of a Real-Time Spirometry Diagnostic Device for Pulmonary Function Assessment Using Flow Sensor and Android Display Mak’ruf, Muhammad Ridha; Pudji, Andjar; Fauzi, Ekha Rifki
Journal of Electrical Engineering and Computer (JEECOM) Vol 8, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v8i3.17038

Abstract

Accurate and convenient measurement of lung function is an important requirement in medical diagnosis. This research was previous research by changing the pressure sensor to develop a flow meter sensor and using an Android display on an Android server. The spirometer tool was developed using an ESP32 microcontroller and a flow meter sensor, the measurement results of which are displayed in real-time on the Nextion LCD and Android server. The measured data includes FVC and FEV1 parameters, with hotspots used to connect the device to the server. Measurements using this tool show the highest error of 0.36% in the FVC parameter and 0.86% in the FEV1 parameter. The lowest error was recorded at 0.01% for FVC and 0.13% for FEV1. Real-time measurement results can be viewed via the Nextion LCD and also accessed via Android devices. The patient's lung volume can be measured accurately and visualized in graphical form. The use of a flow meter sensor connected to an ESP32 microcontroller has proven effective for detecting changes in air flow during patient breathing. The measurement results are stable with a very small error rate. Integration with Android servers makes it easy to monitor results digitally and in real-time. Overall, this device offers a practical and efficient solution for the diagnosis of pulmonary conditions. It can be concluded that the flow meter sensor used in this spirometer can measure lung volume accurately with a very small error rate. This tool can be an effective alternative for real-time and easily accessible FVC and FEV1 measurements.
Co-Authors Achmad Rizal Achmad Rizal Ahmad Fanani Ahmad Fanani Ahmad Zaky Ma'arif Ahniar, Nur Hasanah Alfina Nadhirotussolikah Ali, Latafat Mikayilzade Alievya Brillianty Anugrah Kusuma Amrinsani, Farid Andayani, Dwi Herry Anggara Trisna Nugraha Anita Miftahul Maghfiroh Aprilina Gayuh Arniningtyas Arga Wihantara Arniningtyas, Aprilina Gayuh AskA Putri Hermawan Aulia, Farahun Nisa Bambang Guruh Irianto Barus, Yenda Mita Bogavev, Sergey A. Boy Pribowo Cantika Melinda Denis Kurniar Wicaksono Des, Sima Dwi Herry Andayani Dwi Herry Andayani Dwi Widyaningtyas Edo Rafsanzani Endro Yulianto Erwin L. Rimban Fajar, Fathul Faraz Masood Fathul Fajar Fauzi, Ekha Rifki Fiqih Fahrur Ramadhan Forra Wakidi, Levana Gede Aditya Mahendra Oka Hermawan, Aska Putri I Dewa Gede Budi Whinangun I Dewa Gede Hari Wisana I Dewa Gede Hariwisana I Dewa Gede Hariwisana Ichwan Syahrul Bahtiar Indrato, Tri Bowo Indrato, Tri Bowo Khongdet Phasinam Kirana, Vanda Catur Laily Nurrohmah Lamidi, Lamidi Latafat Mikayilzade Ali Liliek Soetjiatie Lizarazu Maulidil Li Kharis Lusiana Lusiana Lusiana Lusiana Luthfiyah, Sari M. Ridha Mak'ruf M. Ridha Makruf Mak’ruf, Muhammad Ridha Melinda, Cantika Misra, Shubhrojit Mochammad Sofyan Mohamad Adam Firdaus Mufarid, Muhammad Nezar Abdullah Muhammad Fajar Wahyudi Muhammad Nezar Abdullah Mufarid Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Mak'ruf Muhammad Ridha Makruf Muhammad Ridha Mak’ruf Muhammad Ridha Mak’ruf Muhammad Ridha Mak’ruf Muhammad Rois Amin Novella Lasdrei Anna Leediman Nuntachai Thongpance Oka, Gede Aditya Mahendra Oka, I Komang Yogi Mahardika Priyambada Cahya Nugraha Rafsanzani, Edo Ramadhan, Fiqih Fahrur Rizhky, Ayu Nissa Berlianri Sapty Taurisita Fauziah Satheeshkumar Palanisamy Sedigheh Ashgari Baighout Sergey A. Bogavev Setiawan, Singgih Yudha Shengjie Yan Shubhrojit Misra Shubhrojit Misra Sofyan, Mochammad Sumber, Sumber Syaifudin Syaifudin Syaifudin, Syaifudin Thongpance, Nuntachai Torib Hamzah Triwiyanto Triwiyanto Ullah, Naqeeb Utomo, Bedjo Vanda Catur Kirana Vijay Anant Athavale Vugar Abdullayev Widyaningtyas, Dwi Yan, Shengjie Yenda Mita Barus Yunik Pujiastuti