Claim Missing Document
Check
Articles

Gas-Liquid Separator Modified on CV-AAS System for Determination of Total Hg in the Industrial Wastewater Samples Sujito, Sujito; Pasaribu, Subur P; Wirawan, Teguh; Panggabean, Aman Sentosa
Molekul Vol 17 No 3 (2022)
Publisher : Universitas Jenderal Soedirman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.jm.2022.17.3.5039

Abstract

The research about the utilization of modified gas-liquid separators in the determination of Hg ions by using the Cold Vapor Atomic Absorption Spectrophotometer (CV-AAS) method has been done. To optimize the measurement results, several parameters that affect the hydride generator have been studied. Some specified essential parameters are the type and concentration of acid, the level of SnCl2 as a reducing agent, sample volume and the analytical performance such as linearity (r), detection limit (LOD) and quantitation limit (LOQ), repeatability (% RSD), and accuracy have been studied. The results of the research showed the gas-liquid separator modified can be used instead of commercial gas- liquid separators. It was showed by the repeatability value as % RSD < 2/3 CV Horwitz values, the LOD was 0.2530 μg/mL, and the LOQ was 0.8432 μg/mL. The accuracy of this method was good shown by a recovery percentage of 101.6%. Based on the result of this research, the modified of gas-liquid separator can be used for the determination https://www.adenomyosisadviceassociation.org/hysterectomy of Hg ions by using the CV-AAS method with valid results
ANALISA KADAR AMONIA DAN UJI LOGAM BERAT (Fe dan Mn) PADA AIR LIMBAH DOMESTIK Tentriati Cahaya; Aman Sentosa Panggabean; Moh Syaiful Arif
PROSIDING SEMINAR KIMIA Vol 4 No 1 (2025): Prosiding SNK 2025
Publisher : Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A study entitled Analysis of Ammonia Levels and Heavy Metals (Fe and Mn) in Domestic Wastewater has been conducted. This research aimed to determine the concentrations of ammonia and heavy metals (Fe and Mn) in domestic wastewater from the drainage channel on Jalan H. M. Ardans (AL 1) and the wastewater treatment plant of PT. LAB (AL 2). Ammonia levels were analyzed using the phenate spectrophotometric method, while heavy metal concentrations (Fe and Mn) were determined using the Atomic Absorption Spectrophotometry (AAS) method. Based on the analysis results, ammonia levels were found to be 0.45 mg/L in AL 1 and 0.08 mg/L in AL 2. The concentration of iron (Fe) was 3.17 mg/L in AL 1 and 0.50 mg/L in AL 2. The concentration of manganese (Mn) was 15.07 mg/L in AL 1 and 0.30 mg/L in AL 2. The ammonia levels in both AL 1 and AL 2 complied with the quality standard of 10 mg/L. The Fe concentrations in AL 1 and AL 2 also met the quality standard of 5 mg/L. The Mn level in AL 2 met the quality standard of 2 mg/L, whereas the Mn level in AL 1 exceeded the permissible limit. Keywords: ammonia, iron (Fe), domestic wastewater, manganese (Mn)
Preconcentration of Cr (VI) Using Ca-Alginate-EDTA Microcapsules in a Column System for UV-Vis Spectrophotometric Analysis Lianasari, Ika Yekti; Panggabean, Aman Sentosa; Farlianti, Resma Lita
KOVALEN: Jurnal Riset Kimia Vol. 11 No. 2 (2025): December Edition
Publisher : Chemistry Department, Mathematics and Natural Science Faculty, Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/kovalen.2025.v11.i2.17918

Abstract

This study introduces optimized Ca-Alg-EDTA microcapsules specifically designed as a high-performance column filler for the preconcentration and sensitive detection of toxic Cr(VI) in aquatic systems. Monitoring Cr(VI) at trace levels is critical due to its high toxicity and environmental persistence. Unlike previous alginate-based sorbents, this work focuses on a synergistic EDTA integration within a column-switching framework to enhance retention efficiency (74.73 %) and capacity (0.3995 mg/g). Analytical validation using UV-Vis spectrophotometry demonstrated excellent linearity (R2 = 0.9995) with a low detection limit of 0.014 mg/L, ensuring reliability for samples with minimal analyte concentrations. The method’s robustness was confirmed through Mahakam River water analysis, yielding a 93.05 % recovery in compliance with AOAC 2002 standards. This optimized microencapsulation approach provides a cost-effective and sustainable solution for routine environmental monitoring of heavy metal contamination.
Validasi Metode Penentuan Benzena, Toluena dan Xilena pada Sampel Udara dan Tanah Menggunakan Kromatografi Gas Panggabean, Aman Sentosa; Widyastuti, Tika; Hindryawati, Noor
ALCHEMY Jurnal Penelitian Kimia Vol 15, No 1 (2019): March
Publisher : UNIVERSITAS SEBELAS MARET (UNS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (398.077 KB) | DOI: 10.20961/alchemy.15.1.25522.177-189

Abstract

Penelitian tentang validasi metode penentuan kadar benzena, toluena dan xilena pada sampel udara dan tanah dengan menggunakan kromatografi gas telah dilakukan. Untuk mendapatkan hasil pengukuran yang valid, beberapa parameter penting yang berpengaruh dalam validasi metode telah ditentukan. Beberapa parameter penting yang dilakukan adalah penentuan besaran dasar kromatografi yang meliputi: waktu retensi, kapasitas (k’), faktor selektivitas (α) dan kinerja analitik yang meliputi: penentuan linearitas (r), limit deteksi (LOD), limit kuantitasi (LOQ), presisi dan akurasi. Hasil penelitian penentuan kinerja analitik sangat baik ditunjukkan oleh nilai presisi sebagai % KV < 2/3 nilai KV Horwitz, LOD untuk masing-masing senyawa benzena, toluena dan xilena adalah 0,02 mg/L; 0,59 mg/L dan 0,08 mg/L serta LOQ untuk masing-masing senyawa benzena, toluena dan xilena adalah 0,07 mg/L; 1,99 mg/L dan 0,27 mg/L. Akurasi  metode ini sangat baik ditunjukkan dengan nilai presentase perolehan kembali masing-masing senyawa benzena, toluena dan xilena untuk sampel tanah sebesar 102,61 ± 4,61%; 101,65 ± 7,41%; 102,15 ± 4,15%, dan untuk sampel udara masing-masing senyawa sebesar 101,69 ± 5,77%; 102,08 ± 5,43% dan 98,55 ± 5,11%. Berdasarkan hasil penelitian ini, metode kromatografi gas dapat digunakan dalam penentuan benzena, toluena dan xilena pada sampel udara dan tanah dengan memberikan hasil yang valid.Validation Method on The Determination of Benzene, Toluene and Xylene in Air and Soil Samples Using Gas Chromatography. The present study investigated the method for the determination of the content of benzene, toluene, and xylene in air and soil samples using gas chromatography. To obtain a valid measurement result, several important parameters that influence the method validation have been determined. The several important parameters carried out are the determination of the basic chromatographic such as retention time, capacity factor (k'), selectivity (α) and analytical performance measurement includes: the determination of linearity (r), limit of detection (LOD), limit of quantitation (LOQ), precision and accuracy. The result of analytical performance of the research are well verified, in which the value of precision was % CV < 2/3 CV Horwitz value, LOD for benzene, toluene, and xylene compound were 0.02 mg/L, 0.59 mg/L, 0.08 mg/L, respectively, and LOQ for benzene, toluene and xylene compounds was 0.07 mg/L, 1.99 mg/L and 0.27 mg/L respectively. This method achieved high accuration, indicated by a percentage of recovery value of benzene, toluene, and xylene for soil samples of 102.61 ± 4.61%; 101.65 ± 7.41%; 102.15 ± 4.15%, and for air samples was 101.69 ± 5.77%, 102.08 ± 5.43%, and 98.55 ± 5.11% respectively. Based on the results of this research, the method presented in this study can be applied for the determination of benzene, toluene, and xylene using gas chromatography in air and soil samples with valid results.
Prakonsentrasi Ion Cd(II) dalam Sampel Pupuk Nitrogen, Fosfor dan Kalium (NPK) Menggunakan Alumina Teraktivasi sebagai Material Pengisi Kolom Lossi Hotmaida Simanjuntak; Erwin Erwin; Aman Sentosa Panggabean
ALCHEMY Jurnal Penelitian Kimia Vol 16, No 2 (2020): September
Publisher : UNIVERSITAS SEBELAS MARET (UNS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20961/alchemy.16.2.39363.152-162

Abstract

Prakonsentrasi ion Cd(II) dalam sampel pupuk nitrogen, fosfor dan kalium (NPK) menggunakan alumina teraktivasi sebagai material pengisi kolom telah dilakukan. Alumina terlebih dahulu diaktivasi dengan NaOH pada pH 8 sebelum dimasukkan ke dalam kolom. Beberapa parameter penting dalam tahapan prakonsentrasi yang dapat meningkatkan kinerja analitik pengukuran telah ditentukan menggunakan instrumen spektrofotometer serapan atom (SSA). Hasil penelitian menunjukkan kondisi optimum tahapan prakonsentrasi ion Cd(II), adalah pada volume sampel 10 mL, volume HNO3 adalah 4 mL pada konsentrasi 0,5 M, dengan nilai kapasitas retensi adalah 1,4113 mg Cd(II)/g alumina. Kinerja analitik pengukuran metode sangat baik, ditunjukkan dengan nilai batas deteksi metode adalah 2,7997 μg/L. Presisi metode dinyatakan sebagai persentase koefisien variansi adalah 4,03%. Penggunaan alumina sebagai bahan pengisi kolom dapat meningkatkan signal sebesar 2,5 kali dibandingkan dengan pengukuran ion Cd(II) secara langsung. Akurasi metode ini sangat baik, dengan nilai persen perolehan kembali adalah 91,67 – 103,49%, menunjukkan bahwa matriks sampel tidak  mempengaruhi hasil pengukuran, sehingga metode ini dapat digunakan untuk analisis ion Cd(II) dalam sampel pupuk NPK. Estimasi ketidakpastian metode ini juga telah dihitung dan ditunjukkan dengan nilai persen ketidakpastian adalah 14,16%.Preconcentration of Cd(II) Ion in Nitrogen, Phosphor, and Kalium (NPK) Fertilizer Sample Using Activated Alumina as a Column Filler Material. The research about preconcentration of Cd(II) in NPK fertilizer using activated alumina as a column filler material was done. The column used a filler material of alumina previously activated using NaOH at pH 8. Some important parameters in the preconcentration stage are able to increase the analytical performance, determined using atomic absorption spectrophotometer (AAS). The result of the research shows the optimum condition of preconcentration stage Cd(II) ion are volume of the sample was 10 mL, the volume of eluent HNO3 was 4 mL with a concentration of 0.5 M, with the retention of capacity value was 1.4113 mg Cd(II)/g alumina. The analytical performance of this method is good, shown with the limit of detection value was 2.7997 μg/L. The precision of this method was indicated by the percentage of the coefficient variance of 4.03%. Alumina used as a filler column can increase the signal up to 2.5 times for direct Cd(II) ions measurement. The accuracy of this method is excellent, with the recovery percentage value was 91.67 – 103.49%, indicating that the matrices of NPK fertilizer give no effect on the results of measurements, and this method was capable of analyzing Cd(II) ions in NPK fertilizer. The uncertainty of this method was estimated as the percentage of the uncertainty of 14.16%.
Co-Authors -, Yasrin Adha, Laila Sufina Adhi Surya Pranata Surya Pranata Adhi Surya Pranata Surya Pranata, Adhi Surya Pranata Surya Adhitya Rinaldi Akhmad Rifani Akkas, Erwin Ali Murtopo Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alya Yuni Maulana Amrina Rosyada Anggun Ridha Avitri Ani Trisnawati Anwar, Adliah Arif, Moh. Syaiful Arifin Syam Surya arifin syam syam Az Zahra, Upi Fathimah Bagus Muliawan Bayu Iskandar Bohari - Bohari Bohari Bohari Bohari Bohari Yusuf Bohari Yusuf Buchari Buchari Budiono, May Cahaya, Tentriati Chairul Saleh Darmin - Darwin, Chepy Eka Apriska S Kusuma Erwin - Erwin Erwin Erwin Erwin Erwin Erwin Erwin Erwin Erzha, Nutfahryza Fadilah Ramadhani Farida Kristiana Farlianti, Resma Lita Fatimah Islamunisa Filus, Tio Fitriana, Mila Friscylia Friscylia Gaanty Pragas Maniam, Gaanty Pragas Hariati, Hariati Hariati, Hariati Harum Widyastuti Hening Ayu Marinda Hutagalung, Sandi Christopher Idris Mandang, Idris Ika Yekti Lianasari Irviansyah, Alfian Iskandar, Bayu Joni Rahman Josephine Josephine, Josephine Juntia Kirana Pratiwi Khasanah, Manja’a Kumalasari, Anisa Kurniasih, Ririn Feby Kusmiaty, Prilianda Leonardus Lewo Hayon Lossi Hotmaida Simanjuntak Lumban Gaol Veronica Destiana M. Bachri Amran Manja’a Khasanah Margaretta D. R. N. S Marvin Horale Pasaribu May Budiono Mayang, Julia Agustin Menono, Fera Friskaneke Mila Fitriana Moh Syaiful Arif Muhammad Asfian Nur Muhammad Bachri Amran Muhammad Rizky Muhammad Robiansyah Nanang Tri Widodo Nanang Tri Widodo Nauval Dwi Fadillah Nazaratun Thaiyibah Noor Hindryawati Noor Hindryawati, Noor Nur, Nana Septiana Nurhasanah Nurhasanah Oktavia, Dwina Putri Oktaviani, Reka pakasi, Resy Prayuda, Adif Putri, Rinda Anisyah RAHMAT GUNAWAN Rahmat Gunawan Rani Novia Ulya Rida Awliyani Rientha Septiana Rika anggraini Rina Rina Ristia Asri Fidayana Rita Hairani RR Dirgarini Julia Nurlianti Subagyono Rudi Kartika, Rudi Rumengan, Nur Khamillah Sadijah Achmad Saepudin Suwarsa Saibun Sitorus Saibun Sitorus Sandi Christopher Hutagalung Sari, Ermalia Lintang Sari, Ika Yekti Liana Sari, Rahma Juwita Septiana, Rientha Shintia Alifah R Soerja Koesnarpadi Soerja Koesnarpadi Subagyono, Dirgarini Julia Nurlianti Subur P Pasaribu Sujito Sujito Teguh Wirawan Teguh Wirawan, Teguh Tentriati Cahaya Tio Filus Trisnawati, Ani Victoria, Stefanie Widyastuti, Tika Willem Hendrik G Wirdhaningsih Wirdhaningsih Yasser Arafat Yulianti Kartika Yulieta, Afifah Nur Yusuf, Irfan Maulana