Claim Missing Document
Check
Articles

REVIEW ARTIKEL: PEMBUATAN DAN KARAKTERISASI MEMBRAN SELEKTIF ION TIPE KAWAT TERLAPIS Cahaya, Tentriati; Panggabean, Aman Sentosa; Arif, Moh. Syaiful
PROSIDING SEMINAR KIMIA Vol 3 No 2 (2025): Prosiding SNKT 2024
Publisher : Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Industry in Indonesia is growing rapidly, causing an increase in waste including heavy metals and dyes that pollute waters. A method that can be used to detect these contaminants is the Coated Wire Type Ion Selective Electrode (ISE). ISE is an electrochemical sensor that is sensitive to ion activity, characterized by reversible potential changes. This method has the advantages of low cost, simple tools, and high selectivity. This study aims to compare membrane compositions to obtain optimal analytical results and examine electrode characteristics such as the price of the Nernst factor, linear concentration range, detection limit, response time, and life time. The results showed that variations in membrane composition affected electrode sensitivity and stability. This research is important for developing more efficient ISE for detecting heavy metals and dyes in polluted environments. Keywords : Ion Selective Electrode, Wire Coated, Potentiometry
Penentuan Validasi Metode Analisa Kadar Tinbal (Pb) Pada Kosmetik Berbagai macam merek dengan menggunakan Spektrofotometer UV-Visible Putri, Amelia; Lianasari, Ika Yekti; Panggabean, Aman Sentosa; Pasaribu, Subur P.; Bohari, Bohari
JURNAL KIMIA MULAWARMAN Vol 22 No 2 (2025)
Publisher : Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30872/jkm.v22i2.1291

Abstract

Penelitian tentang validasi metode penentuan kadar timbal (Pb) pada kosmetik menggunakan spektrofotometer UV-Visible telah dilakukan. Validasi metode dilakukan dengan menentukan parameter validitas yang diuji antara lain yaitu uji linieritas dengan nilai koefisien korelasi sebesar 0,9998; limit deteksi 0,161 mg/L, limit kuantitasi 0,537 mg/L, uji akurasi diperoleh dengan persentase perolehan kembali yang memenuhi syarat keberterimaan yaitu 81,5-93,7% dan uji presisi untuk semua konsentrasi secara keseluruhan masih dapat diterima yaitu < 2%; serta nilai RSD yang diperoleh lebih kecil dari 2/3 CV Horwitz. Hasil analisis dari sembilan sampel diperoleh ada satu sampel yang tidak memenuhi syarat yaitu pada kode sampel B2 dengan kadar timbal sebesar 26,6 mg/kg, sehingga tidak aman untuk digunakan. Sedangkan untuk sampel lainnya masih dinyatakan aman karena memiliki kadar timbal dibawah baku mutu cemaran yang telah ditentukan BPOM yaitu ≤ 20 mg/kg.
Gas-Liquid Separator Modified on CV-AAS System for Determination of Total Hg in the Industrial Wastewater Samples Sujito, Sujito; Pasaribu, Subur P; Wirawan, Teguh; Panggabean, Aman Sentosa
Molekul Vol 17 No 3 (2022)
Publisher : Universitas Jenderal Soedirman

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.jm.2022.17.3.5039

Abstract

The research about the utilization of modified gas-liquid separators in the determination of Hg ions by using the Cold Vapor Atomic Absorption Spectrophotometer (CV-AAS) method has been done. To optimize the measurement results, several parameters that affect the hydride generator have been studied. Some specified essential parameters are the type and concentration of acid, the level of SnCl2 as a reducing agent, sample volume and the analytical performance such as linearity (r), detection limit (LOD) and quantitation limit (LOQ), repeatability (% RSD), and accuracy have been studied. The results of the research showed the gas-liquid separator modified can be used instead of commercial gas- liquid separators. It was showed by the repeatability value as % RSD < 2/3 CV Horwitz values, the LOD was 0.2530 μg/mL, and the LOQ was 0.8432 μg/mL. The accuracy of this method was good shown by a recovery percentage of 101.6%. Based on the result of this research, the modified of gas-liquid separator can be used for the determination https://www.adenomyosisadviceassociation.org/hysterectomy of Hg ions by using the CV-AAS method with valid results
ANALISA KADAR AMONIA DAN UJI LOGAM BERAT (Fe dan Mn) PADA AIR LIMBAH DOMESTIK Tentriati Cahaya; Aman Sentosa Panggabean; Moh Syaiful Arif
PROSIDING SEMINAR KIMIA Vol 4 No 1 (2025): Prosiding SNK 2025
Publisher : Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A study entitled Analysis of Ammonia Levels and Heavy Metals (Fe and Mn) in Domestic Wastewater has been conducted. This research aimed to determine the concentrations of ammonia and heavy metals (Fe and Mn) in domestic wastewater from the drainage channel on Jalan H. M. Ardans (AL 1) and the wastewater treatment plant of PT. LAB (AL 2). Ammonia levels were analyzed using the phenate spectrophotometric method, while heavy metal concentrations (Fe and Mn) were determined using the Atomic Absorption Spectrophotometry (AAS) method. Based on the analysis results, ammonia levels were found to be 0.45 mg/L in AL 1 and 0.08 mg/L in AL 2. The concentration of iron (Fe) was 3.17 mg/L in AL 1 and 0.50 mg/L in AL 2. The concentration of manganese (Mn) was 15.07 mg/L in AL 1 and 0.30 mg/L in AL 2. The ammonia levels in both AL 1 and AL 2 complied with the quality standard of 10 mg/L. The Fe concentrations in AL 1 and AL 2 also met the quality standard of 5 mg/L. The Mn level in AL 2 met the quality standard of 2 mg/L, whereas the Mn level in AL 1 exceeded the permissible limit. Keywords: ammonia, iron (Fe), domestic wastewater, manganese (Mn)
Preconcentration of Cr (VI) Using Ca-Alginate-EDTA Microcapsules in a Column System for UV-Vis Spectrophotometric Analysis Lianasari, Ika Yekti; Panggabean, Aman Sentosa; Farlianti, Resma Lita
KOVALEN: Jurnal Riset Kimia Vol. 11 No. 2 (2025): December Edition
Publisher : Chemistry Department, Mathematics and Natural Science Faculty, Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/kovalen.2025.v11.i2.17918

Abstract

This study introduces optimized Ca-Alg-EDTA microcapsules specifically designed as a high-performance column filler for the preconcentration and sensitive detection of toxic Cr(VI) in aquatic systems. Monitoring Cr(VI) at trace levels is critical due to its high toxicity and environmental persistence. Unlike previous alginate-based sorbents, this work focuses on a synergistic EDTA integration within a column-switching framework to enhance retention efficiency (74.73 %) and capacity (0.3995 mg/g). Analytical validation using UV-Vis spectrophotometry demonstrated excellent linearity (R2 = 0.9995) with a low detection limit of 0.014 mg/L, ensuring reliability for samples with minimal analyte concentrations. The method’s robustness was confirmed through Mahakam River water analysis, yielding a 93.05 % recovery in compliance with AOAC 2002 standards. This optimized microencapsulation approach provides a cost-effective and sustainable solution for routine environmental monitoring of heavy metal contamination.
Co-Authors -, Yasrin Adha, Laila Sufina Adhi Surya Pranata Surya Pranata Adhi Surya Pranata Surya Pranata, Adhi Surya Pranata Surya Adhitya Rinaldi Akhmad Rifani Akkas, Erwin Ali Murtopo Alimuddin Alimuddin - Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alimuddin Alya Yuni Maulana Amrina Rosyada Anggun Ridha Avitri Ani Trisnawati Anwar, Adliah Arif, Moh. Syaiful Arifin Syam Surya arifin syam syam Az Zahra, Upi Fathimah Bagus Muliawan Bayu Iskandar Bohari - Bohari Bohari Bohari Bohari Bohari Yusuf Bohari Yusuf Buchari Buchari Buchari Buchari Budiono, May Cahaya, Tentriati Chairul Saleh Darmin - Darwin, Chepy Dirgarini Julia Nurlianta Subagyono Eka Apriska S Kusuma Erwin - Erwin Erwin Erwin Erwin Erwin Erwin Erwin Erwin Erzha, Nutfahryza Fadilah Ramadhani Farida Kristiana Farlianti, Resma Lita Fatimah Islamunisa Filus, Tio Fitriana, Mila Friscylia Friscylia Gaanty Pragas Maniam, Gaanty Pragas Hariati, Hariati Hariati, Hariati Harum Widyastuti Hening Ayu Marinda Hutagalung, Sandi Christopher Idris Mandang, Idris Irviansyah, Alfian Iskandar, Bayu Joni Rahman Josephine Josephine, Josephine Juntia Kirana Pratiwi Khasanah, Manja’a Kumalasari, Anisa Kurniasih, Ririn Feby Kusmiaty, Prilianda Leonardus Lewo Hayon Lianasari, Ika Yekti Lossi Hotmaida Simanjuntak Lumban Gaol Veronica Destiana M. Bachri Amran Manja’a Khasanah Margaretta D. R. N. S Marvin Horale Pasaribu May Budiono Mayang, Julia Agustin Menono, Fera Friskaneke Mila Fitriana Moh Syaiful Arif Muhammad Asfian Nur Muhammad Bachri Amran Muhammad Rizky Muhammad Robiansyah Nanang Tri Widodo Nanang Tri Widodo Nauval Dwi Fadillah Nazaratun Thaiyibah Noor Hindryawati Noor Hindryawati, Noor Nur, Nana Septiana Nurhasanah Nurhasanah Oktavia, Dwina Putri Oktaviani, Reka pakasi, Resy Prayuda, Adif Putri, Amelia Putri, Rinda Anisyah RAHMAT GUNAWAN Rahmat Gunawan Rani Novia Ulya Rida Awliyani Rientha Septiana Rika anggraini Rina Rina Ristia Asri Fidayana Rita Hairani Rudi Kartika, Rudi Rumengan, Nur Khamillah Sadijah Achmad Saepudin Suwarsa Saibun Sitorus Saibun Sitorus Sandi Christopher Hutagalung Sari, Ermalia Lintang Sari, Ika Yekti Liana Sari, Rahma Juwita Septiana, Rientha Shintia Alifah R Soerja Koesnarpadi Soerja Koesnarpadi Subagyono, Dirgarini Julia Nurlianti Subur P Pasaribu Sujito Sujito Teguh Wirawan Teguh Wirawan, Teguh Tentriati Cahaya Tika Widyastuti Tio Filus Trisnawati, Ani Victoria, Stefanie Willem Hendrik G Wirdhaningsih Wirdhaningsih Yasser Arafat Yulianti Kartika Yulieta, Afifah Nur Yusuf, Irfan Maulana