Claim Missing Document
Check
Articles

BIAYA TRANSPORTASI AKIBAT ADANYA PARKIR DI BADAN JALAN Bolla, Margareth E.; Bella, Rosmiyati A.; Hale Kore, Desri M.
Jurnal Teknik Sipil Vol 6, No 2 (2017): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (243.204 KB)

Abstract

Parkir di badan jalan (on-street parking) merupakan salah satu permasalahan lalulintas perkotaan yang juga terjadi pada kawasan pertokoan di Kota Kupang yakni di ruas jalan Siliwangi. Penelitianini bertujuan untuk mengetahui berapa besar Biaya Operasional Kendaraan (BOK) yang ditanggungoleh setiap pengendara yang melintasi ruas jalan ini dan berapa besar retribusi parkir akibat adanyakegiatan on-street parking. Survei dilakukan sepanjang 13 jam yaitu dari jam 08.00-21.00 Witaselama 12 hari, pada 2 segmen pengamatan. Perhitungan BOK didasarkan pada metode Manual BOK1995, selanjutnya besaran biaya kemacetan dihitung dengan persamaan Tzedakiz, serta dihitung jugabesarnya biaya yang ditanggung dari retribusi parkir untuk mengetahui besar selisihnya. Dari hasilanalisis, diperoleh nilai BOK terbesar terjadi pada pukul 18.00-19.00 Wita, yaitu sebesar Rp.26,11/jam untuk jenis kendaraan sepeda motor (MC), Rp. 61,85/jam untuk jenis kendaraan mobilpenumpang (LV) dan Rp. 28,24/jam untuk jenis kendaraan berat (HV). Biaya kemacetan yang harusditanggung pengendara setiap melintas ruas jalan Siliwangi adalah sebesar Rp.319,29/kendaraan/jam/puncak/perjalanan dan sebesar Rp. 472.296,06 untuk total jumlah kendaraan/13 jam pengamatan,sementara total biaya retribusi dari on-street parking-nya/13 jam pengamatan adalah sebesar Rp.224.541,67, sehingga selisih antara biaya kemacetan dan biaya retribusi parkir yaitu sebesar Rp.247.754,39. On-street parking is one of the urban traffic problems that occurs in the shopping area in Kupang City which is on Siliwangi road. This study aims to analyze the Vehicle-Operating-Cost (VOC) that is borne by every rider passing through the road and the amount of parking fees due to on-street parking activities. The survey was conducted in 13 hours observation that is from 08.00-21.00 Wita for 12 days, on 2 segment of observation. The calculation of VOC is based on BOK Manual 1995, while the congestion cost is calculated by Tzedakiz equation. The calculation of on-street parking’s retribution is done to know the difference to congestion cost. The analysis showed that the biggest VOC occurred at 18.00-19.00 Wita, that is Rp. 26,11/hour for motorcycle (MC), Rp. 61,85/hour for light vehicle (LV) and Rp. 28.24/hour for heavy vehicle (HV). The congestion cost that must be borne by the rider every pass through Siliwangi road is Rp. 319.29/vehicle/peak hour/ journey, and Rp. 472,296.06 for the entire number of vehicles during 13 hours of observation, while the total cost of retribution from its onstreet parking/13 hours of observation is Rp. 224,541.67, so the difference between congestion cost and parking fees is Rp. 247.754,39.
PERMODELAN TIMBUNAN PADA TANAH LUNAK DENGAN MENGGUNAKAN PROGRAM PLAXIS Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 1, No 2 (2011)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (123.836 KB)

Abstract

ABSTRACTIn civil construction frequently encountered problems in soft soils, such as lowbearing capacity and large settlement if given the burden. It is because the soft soilgenerally has low shear strength, low permeability and large compressibility. Thestudy was conducted to compare the speed of settlement and stability problemsembankment on soft soil due to the method of preloading and vertical drains. Theuse of the method of preloading and vertical drains on the embankment canimprove the stability of the construction.ABSTRAKDalam pembangunan konstruksi sipil sering dijumpai permasalahan padajenis tanah lunak, antara lain daya dukung tanah yang rendah dan penurunan(settlement) yang besar jika diberi beban. Hal ini disebabkan karena tanah lunakumumnya memiliki kuat geser dan permeabilitas yang rendah sertakompresibilitas yang besar. Kajian ini dilakukan untuk membandingkan kecepatanpenurunan konsolidasi dan masalah stabilitas timbunan di atas tanah lunak akibatdari metode prapembebanan dan drainase vertikal. Hasil yang diperoleh adalahpenggunaan metode prapembebanan dan drainase vertikal dapat meningkatkankestabilan pada konstruksi timbunan.
PENGGUNAAN PASIR WEOL SEBAGAI BAHAN CAMPURAN MORTAR DAN BETON STRUKTURAL Kadimas, Irenius O.R; Pah, Jusuf J.S.; Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 6, No 1 (2017)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (387.599 KB)

Abstract

Concrete is formed from a mixture of water, cement, sand and coarse aggregate. The quality of sand affects the quality of the concrete. Weol sand is aggregate in the subdistrict Ruteng, Manggarai district, which is used by people for mortar and non-structural concrete. This is because the location of which is closer than the other sand. This study aims to determine the compressive strength of mortar and concrete using Weol sand.The method of implementation refers to the SNI 03-2834-2000 (BSN 2000) about Manufacturing Process Plan Mixture for Normal Concrete and SNI 03-6825-2002 (BSN 2002b) about The Test Method of Compressive Strength Portland Cement Mortar. The mortar cube has size 5x5x5 with composition 1PC: 2Psr, 1PC: 4Psr, 1PC: 6Psr and 1PC: 8Psr. The diameter and high of cylindrical concrete is 15 cms and 30 cms. Mortar compressive strength testing performed at 3 days, 7 days, 14 days and 28 days while the concrete at 7 days, 14 days and 28 days.The test results show that the compressive strength of mortar using Weol sand for each composition and the compressive strength of concrete using Weol sand for each quality plan is larger than mortar and concrete using Takari sand.
PENGARUH WAKTU DAN TEMPAT PENYIMPANAN TERHADAP SIFAT FISIK DAN MEKANIS TANAH PASIR Bella, Rosmiyati A.; Jati, Robertus H.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 3, No 2 (2014): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (278.884 KB)

Abstract

Hasil analisis sifat teknis tanah berupa sifat fisik dan mekanisdi laboratorium merupakan gambaran keadaan sesungguhnya di lapangan. Pada kenyataannya penetapan parameter sifat fisik dan mekanis tanah sering tidak mewakili keadaan sesungguhnya.Tujuannya adalah untuk mengetahui pengaruh waktu dan tempat penyimpanan terhadap sifat fisik dan mekanis. Analisa data dilakukan dengan membuat perhitungan berdasarkan hasil pengujian kadar air dan kuat geser. Pendekatan regresi linear digunakan pada analisis kadar air untuk mengetahui pola penurunan kadar air. Akibat lama waktu penyimpanan terhadap sifat fisik adalah terdapat dua pola penurunan kadar air. Pola 1 adalah penurunan kadar air secara signifikan pada range hari ke-0 sampai hari ke-6 dan pola 2 adalah penurunan kadar air secara landai pada hari ke-6 sampai hari ke-27. Penurunan kadar air yang terbesar terjadi pada sampel yang disimpan pada ruang bebas,yakni 6.03% pada sampel Tarus dan 9.29% pada sampel Namosain, sedangkan yang terkecil adalah sampel yang disimpan pada box sampel yakni 3.39% pada sampel Tarus dan 3.88% pada sampel Namosain. Persentase perubahan kekuatan geser yang terbesar dari hari ke-0 hingga hari ke-27 adalah 4.79% pada sampel Tarus dan 0.89% pada sampel Namosain.
PERHITUNGAN DEBIT SIMULASI DENGAN DEBIT TERUKUR PADA DAS MANIKIN Nomleni, Rosany A.; Nasjono, Judi K.; Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 8, No 2 (2019): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (238.234 KB)

Abstract

Debit air yang mengalir di sungai sangat bergantung pada beberapa faktor antara lain bentuk sungai dan besarnya curah hujan yang turun. Semakin besar curah hujan yang turun maka semakin besar pula debit air di sungai oleh karena itu perlu dilakukan analisis debit maksimum di Daerah Aliran Sungai Manikin. Tujuan dari penelitian ini adalah untuk mendapatkan nilai debit simulasi berdasarkan curah hujan metode Aritmtik, Thiessen dan Isohiet dan debit terukur berdasarkan data tinggi muka air. Debit Simulasi dan terukur diuji menggunakan metode Mean Square Error dan Nash Sutcliffe Efficiency. Dari hasil penelitian diperoleh jumlah nilai hujan maksimum metode Aritmatik tahun 2009-2017 sebesar 681,000 mm, metode Thiessen sebesar 664,080 mm, dan metode Isohiet sebesar 982,111 mm. Nilai debit terukur yang terbesar terjadi pada tahun 2015 sebesar 46,370 m3/dtk. Nilai debit simulasi terbesar menurut metode Aritmatik yaitu pada tahun 2014 sebesar 90,779 m3/dtk, metode Thiessen tahun 2011 sebesar 102,202 m3/dtk, dan metode Isohiet tahun 2015 sebesar 148,940 m3/dtk. Nilai MSE untuk metode Aritmatik sebesar 4439,522 dan nilai NSE sebesar -18,368, nilai MSE untuk metode Thiessen sebesar 4218,128 dan nilai NSE sebesar -17,403, nilai MSE untuk metode Isohiet sebesar 9319,230 dan nilai NSE sebesar -39,657.The discharge water flows in the river depends on several factors, including the shape of the river and the amount of rainfall that falls. The greater the rainfall that falls, the greater the water discharge in the river, therefore the maximum discharge analysis needs to be done in the Manikin Watershed. The purpose of this study is to obtain a simulated discharge value using the Rational method based on rainfall, arrhythmic, thiessen and isohiet methods and measured discharge based on water level data. Simulation and measured discharge were tested using the Mean Square Error and Nash Sutcliffe Efficiency methods. From the results of the study, the maximum rain value of the Arithmetic method in 2009-2017 is 681,000 mm, the Thiessen method is 664,080 mm, and the Isohiet method is 982,111 mm. The largest measured discharge value  occurred in 2015 at 46,370 m3/sec. The simulation discharge value is the largest according to the Arithmetic method, namely in 2014 amounted to 90.779 m3/sec, the Thiessen method in 2011 is 102.202 m3/sec, and the Isohiet method in 2013 is 148.940 m3/sec. The MSE value for the Arithmetic method is 4439,522 and the NSE value is -18,368, the MSE value for the Thiessen method is 4218,128 and the NSE value is -17,403, the MSE value for the Isohiet method is 9319,230 and the NSE value is -39,657.
SOLUSI PENCEGAHAN KECELAKAAN KERJA DALAM PELAKSANAAN KONSTRUKSI GEDUNG DI KOTA KUPANG Messah, Yunita A.; Bella, Rosmiyati A.; Lolo, Teguh A. S.
Jurnal Teknik Sipil Vol 4, No 2 (2015)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (454.333 KB)

Abstract

Kasus kecelakaan di Provinsi NTT yang terjadi dalam lima tahun terakhir berfluktuasi selama periode tahun 2009 hingga tahun 2013.Dari data terdapat lima jenis kecelakaan yaitu kecelakaan karena tergelincir, terpukul, terkena benda tajam/keras, kecelakaan karena kejatuhan benda, alat pengangkutan dan lalu lintas, jatuh dari ketinggian, dan kecelakaan karena aliran listrik, kebakaran dan ledakan. Tujuan penelitian ini untuk mengetahui persentase penyebab kecelakaan yang paling sering terjadi dan mengetahui cara perusahaan dalam memberikan prioritas penanganan atau solusi jika terjadi kecelakaan kerja pada suatu proyek konstruksi gedung.Penelitian ini menggunakan metode survei kuisioner dengan jumlah sampel 19 perusahaan, di mana terdapat 2 perusahaan BUMN dan 17 perusahaan swasta nasional. Data dianalisis menggunakan metode AHP dengan bantuan Software Expert Choice. Hasil penelitian menunjukan bahwa 36,84 % disebabkan oleh jalan yang licin dan gelap, sedangkan karena pekerja tidak mengenakan topi pelindungsebesar 31.58 %. Untuk solusi pencegahan yaitu cara kerja harus dalam posisi yang benar, tetap hati-hati, teliti dan disiplin,dipasang tanda “Hati-hati, ada pekerjaan di atas”,dipasang jala pengaman di area bawah, dilarang membuang benda yang tidak terpakai ke bawah, penyimpanan peralatan pada tempatnya, mengangkat material/peralatan tidak melebihi batas muatan, pemasangan material/peralatan harus baik, dan cara mengangkat material/peralatan ke atas harus benar. Cases of work accidents in the province of Nusa Tenggara Timur that occurred in the last five years fluctuate during period from 2009 to 2013. From these data, there are five types of accidents are accidents due to slipping, hit, hit by sharp / hard, accidents due to falling objects, accidents due to tool transport and traffic, accidents due to falling from heights, and accidents due to electricity, fire and explosion. The purpose of this study was to determine the percentage of the most frequent causes of accidents occurred in the building construction project and to find out how the company in giving priority treatment in case of an accident or a solution working on a project construction of building.This study uses a questionnaire survey the number of Samper 19 companies, where there are two state-owned companies and 17 national private companies. Results were analyzed data collection using AHP with the aid of Expert Choice Software. The results showed that 36.84%,hit by sharp / hard due to slippery roads and dark, because the workers were not wearing safety helmetof 31.58%. For priority prevention solutions provided by the company, which for this type of accident due to slip, hit, hit by sharp / hard, there are two priority prevention solutions that work the way should be in the position and the right attitude and workers must remain cautious, conscientious and disciplined, installed signs "Be careful, there are jobs at the top", needs to be installed safety nets in the area below, is prohibited from disposing objects unused down, placement of objects or equipment should be in place, lifting equipment does not exceed the load limits, installation material / equipment to be good and in place, and how to lift material / equipment up to be true.
PERBANDINGAN PERSENTASE PENAMBAHAN FLYASH TERHADAP KUAT TEKAN BATA RINGAN JENIS CLC Bella, Rosmiyati A.; Pah, Jusuf J. S.; Ratu, Ariansyah G.
Jurnal Teknik Sipil Vol 6, No 2 (2017): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (172.962 KB)

Abstract

Penelitian ini bertujuan untuk mengetahui densitas, kuat tekan dan serapan pada bata ringan dengan menggunakan fly ash sebagai pengganti semen. Metode yang digunakan dalam penelitian ini adalah metode eksperimen dengan menggantikan semen dengan fly ash dengan variasi penambahannya sebesar 10% hingga 90% dari berat semen dengan kenaikan 10%. Pengujian kuat tekan dan densitas dilakukan pada masa perawatan bata ringan berumur 7, 21, dan 28 hari sedangkan pengujian serapan air dilakukan pada umur 28 hari. Kuat tekan maksimum berada pada variasi fly ash 10%, selama masa perawatan berturut-turut sebesar 0,633 MPa, 0,781 MPa, 0,819 Mpa dengan densitas selama masa perawatan berturut-turut sebesar 750,741 kg/m3, 664,444 kg/m3, 588,519 kg/m3 serta serapan air sebesar 26,256%. Untuk kuat tekan minimum bata ringan dihasilkan pada variasi fly ash 40% berturut-turut sebesar 0,485 MPa, 0,633 MPa, 0,670 MPa, dengan densitas selama masa perawatan berturut-turut sebesar 585,556 kg/m3, 566,296 kg/m3, 549,259 kg/m3 serta serapan air sebesar 38,184%. Variasi fly ash pengganti semen dengan kadar 50% ke atas mengalami gagal/pecah. Berdasarkan penelitian tersebut variasi fly ash sebesar 40% merupakan batas maksimum penambahan fly ash pada bata ringan CLC dikarenakan penambahan fly ash dapat berpengaruh terhadap kekuatan bata ringan itu sendiri akibat tidak adanya ikatan antar agregat. The objective of this research was to find out the density, compressive strength and absorption of lightweight brick by using fly ash as the substitute of cement. The method used in this research was experimental method by substituting cement with fly ash. The variations were 10% to 90% of cement weight with 10% increment. The compressive strength test was conducted when the lightweight brick was 7,21 and 28 days for the water absorption. The maximum compressive strength was achieved in the 10% of fly ash variation, during the treatment of 0,633 MPa, 0,781 MPa, 0,819 MPa with the density of 750,741 kg/m3, 664,444 kg/m3, 588,519 kg/m3 and 38,184% of water absorption. Whereas, the variation of 50% fly ash as the substitution of cement was failed or cracked. This research indicated that the 40% variation of fly ash was the maximum limit to be added to the CLC lightweight brick for the reason that the addition of fly ash could affect the strength of the brick as the consequence of the non-existent aggregate bonds.
PROGRAM DESAIN PENULANGAN DINDING PENAHAN TANAH (RETAINING WALL) MENGGUNAKAN PERANGKAT LUNAK VISUAL BASIC .NET 2008 Star, Anastasia; Bella, Rosmiyati A.; Cornelis, Remigildus
Jurnal Teknik Sipil Vol 1, No 4 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2081.667 KB)

Abstract

The retaining wall usually used to resist lateral pressure which is caused by backfill material. The stability of retaining wall is obtained mainly from its weight and the weight of the soil at the toe and the heel of retaining wall. The purpose of this research is make a program to design the semi gravity wall and the cantilever wall by using Visual Basic. NET 2008 program. SC Wall 2011 is a result of this research that using programming language of Visual Basic .NET 2008 that used to calculate the stability and reinforcement of the cantilever and semi gravity wall. Based on the output of SC Wall 2011, it shows that the program can be used to design the cantilever wall and the semi gravity wall, because its calculation is faster than the manual calculation. This program needs approximately 1.5 minutes to solve a simple problems.
PENGARUH VARIASI UKURAN BUTIRAN AGREGAT TERHADAP KUAT TEKAN BATA RINGAN JENIS CLC Pah, Jusuf J. S.; Sehandi, Krisogonus; Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 8, No 1 (2019): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (171.117 KB)

Abstract

Bata ringan CLC adalah bata yang memiliki berat jenis lebih ringan daripada bata pada umumnya dengan komposisi semen, pasir, air dan foam agent. Penelitian ini bertujuan mencari nilai kuat tekan dan berat volume bata ringan CLC menggunakan beberapa variasi ukuran butiran agregat. Variasi yang digunakan yaitu variasi A (1,18 < d ≤ 2,36 dan 4,75 < d ≤ 9,50), variasi B (0,60 < d ≤ 1,18 dan 2,36 < d ≤ 4,75), variasi C (0,30 < d ≤ 0,60 dan 1,18 < d ≤ 2,36), dan variasi D (d ≤ 4,75). Metode dalam penelitian ini yaitu pengujian laboratorium dengan membuat bata ringan CLC menggunakan pasir Takari yang telah diayak sesuai ukuran variasi yang direncanakan. Pengujian kuat tekan dan berat volume dilakukan pada bata ringan CLC berumur 7, 14, 21 dan 28 hari. Kuat tekan maksimum berasal dari variasi D sebesar 0,719 MPa, 0,753 MPa, 0,842 MPa, 0,897 MPa secara berturut-turut selama masa perawatan. Sementara berat volume maksimum juga dari variasi D selama masa perawatan secara berturut-turut sebesar 0,656 gr/cm3, 0,607 gr/cm3, 0,575 gr/cm3, 0,559 gr/cm3. Bata ringan dengan kinerja total terbaik berdasarkan perbandingan kuat tekan terhadap densitas dalam penelitian ini adalah bata ringan yang dibuat dengan menggunakan variasi B.CLC is a brick that has lighter density compared to usual brick composed by cement, sand, water and foam agent. This research aimed to search compressive strength value and lightweight brick CLC density using several variations of aggregate grain size. Variations used are variation A (1.18 <d≤ 2.36 and 4.75 <d≤ 9.50), variation B (0.60 <d≤ 1.18 and 2.36 <d≤ 4.75 ), variation C (0.30 <d≤ 0.60 and 1.18 <d≤ 2.36), and variation D (d ≤ 4.75). This research used laboratory testing method by making lightweight bricks CLC using sifted Takari sand according to variation size that has been planned before. Testing towards compressive strength and density tested on lightweight bricks CLC aged 7, 14, 21 and 28 days. Maximum compressive strength made using variation D in the amount of 0.719 MPa, 0.753 MPa, 0.842 MPa, 0.897 MPa in a row during treatment period. While the maximum density also came from variation D during treatment period in a row in amount of 0.656 gr/cm3, 0.607 gr/cm3, 0.575 gr/cm3, 0.559 gr/cm3. Lightweight brick with the best quality based on the ratio of compressive strength to density in this research is a lightweight brick that made using variation B.
EVALUASI KINERJA ANGKUTAN UMUM TRAYEK TERMINAL OEBOBO - TERMINAL KUPANG PP DAN TERMINAL KUPANG - TERMINAL NOELBAKI PP Safe, Yohanes T.; Udiana, I Made; Bella, Rosmiyati A.
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (253.743 KB)

Abstract

Beberapa ruas jalan pada Trayek Terminal Oebobo-Terminal Kupang PP dan trayek Terminal Kupang-Terminal Noelbaki PP, pada jam-jam puncak angkutan umum yang ada cenderung digunakan melebihi kapasitas maksimumnya. Keadaan sebaliknya terjadi pada jam non-puncak, kendaraan umum setengah kosong dan harus melakukan kompetisi dengan angkutan umum lainnya untuk mendapatkan penumpang. Tujuan dari penelitian adalah mengetahui kinerja pelayanan angkutan umum, kebutuhan angkutan umum dan membuat rekomendasi terkait dengan hasil evaluasi kinerja pelayanan pada kedua trayek ini. Dalam penelitian ini indikator kinerja angkutan umum yang dinilai adalah faktor muat, waktu perjalanan, frekuensi pelayanan, waktu antara, waktu tunggu, jumlah kendaraan yang beroperasi, dan waktu pelayanan. Indikator-indikator tersebut diperoleh dari hasil survey dinamis dan survey statis. Dari hasil evaluasi standar pelayanan angkutan umum menurut Dirjen Perhubungan Darat, kinerja pelayanan angkutan umum pada trayek Terminal Oebobo-Terminal Kupang PP dan Terminal Kupang-Terminal Noelbaki PP termasuk kategori baik. Kebutuhan jumlah angkutan umum pada trayek Terminal Oebobo-Terminal Kupang PP adalah 22 unit, sedangkan untuk trayek Terminal Kupang-Terminal Noelbaki PP sebanyak 40 unit. Berdasarkan hasil evaluasi diberikan rekomendasi diantaranya: jumlah angkutan umum yang sudah ada dipertahankan saja atau dikurangi hingga mendekati nilai rata-rata jumlah kendaraan beroperasi setiap hari serta perlunya pembinaan pada pengemudi tentang kesadaran berlalu lintas yang baik di jalan raya. Sometimes in Oebobo Station-Kupang Station route and Kupang Station-Noelbaki Station route, over capacity for public transportation happened in the peak time especially in several roads. While, in peak off time, most of public transportation have no passanger, so they had to compotate with the other transportation the get the passanger. Service operational planning of public transportation should be evaluate as soon as possible to know how about the performance of public transportation services. The goal of this research are to know about public transportation services performance, fleet necessity of public transportation and make recommendations relating to the results of the performance evaluation of services on this route both. The indicators of this research are public transportation performance, load factor, time journey, frequency, time line, passenger time waiting, the quantity of vehicle operated, and time services. All of these indicators get from dinamyc and statistic survey. From the results of the public transport service standards evaluation by the Directorate General of Land Transportation, the performance of public transport services on the Oebobo Station-Kupang Station Route and Kupang Station-Noelbaki Station Route including good categories. The needs of public transport fleet on the Oebobo Station-Kupang Station Route is 22 units, whereas for Kupang Station-Noelbaki Station Route 40 units. Based on the results of the evaluation given recommendations are: for while the number of existing public transport or retained only if necessary, be reduced to close to the average value of the number vehicles in operation each day as well as the need for guidance drivers about traffic awareness good on the highway.