Claim Missing Document
Check
Articles

Found 1 Documents
Search
Journal : Jurnal Polimesin

Energy and exergy performance of R290 as a substitute for R404A in freezers: experimental investigation Akmal, Muhammad; Sumeru, Kasni; Tohir, Toto; Hikmat, Yudi Prana; Nuryati, Neneng; Sulaimon, Shodiya
Jurnal Polimesin Vol 23, No 2 (2025): April
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v23i2.6153

Abstract

The refrigeration sector significantly contributes to global warming due to the high Global Warming Potential (GWP) of commonly used refrigerants. This study experimentally investigates the feasibility of using R290 as a low-GWP substitute for R404A in freezer applications. Although R290 and R404A have similar normal boiling points, their GWP values differ significantly (3 for R290 vs. 3922 for R404A), making R290 a more environmentally friendly alternative. Experiments were conducted on a freezer originally designed for R404A with a 1/3 HP compressor and a refrigerant charge of 170 g. After baseline testing with R404A, the system was retrofitted with R290, using an optimized charge of 62.9 g. The system's performance was analyzed over 120 minutes, with energy and exergy evaluations conducted at 60 minutes, when the cabin temperature stabilized. Results from energy analysis indicate that replacing R404A with R290 led to a 6.1% increase in cooling capacity, a 6.0% reduction in power consumption, and a 12.4% improvement in COP. Exergy analysis showed that total irreversibility decreased from 318.1 W (R404A) to 289.8 W (R290), with compressor irreversibility being the dominant factor (50.8% for R404A vs. 51.3% for R290). The findings confirm that R290 enhances system performance by reducing irreversibility and energy consumption. These results highlight R290 as an energy-efficient and environmentally friendly alternative to R404A, providing both operational cost savings and reduced environmental impact. However, to achieve optimal performance, compressor lubricant replacement is recommended when transitioning to R290.
Co-Authors Abdullah Assegaf Adithia Maulady Adnan Rafi Al Tahtawi Aghnia Nur Zahrah Agriyani, Fioni Ahmad Sofyan Ahmad Yusuf Aisyah Indah Almira Ambar Susanto Anisa Dyah Lestari Annisa Nurul Sholihah Anwar, Hadrian Arifal Triprasetyo Adi Ashshidiqi, Hasbi Ayu, Aninda Framesti Ratna Azzahra Salsabila Baisrum Baisrum, Baisrum Bambang Puguh Manunggal Bimo Fajrie Alwaaritsi Brian Fadilah Susanto Budi Setiadi Budi Setiadi, Budi Budi Triyono Budi Utomo, Heri Dandy Nugraha Darwati, Endang Dedi Aming Destri Muliastri Dey Ravena Dian Ekawati Diki Diki Dwi Septiyanto, Dwi Endang Habinuddin Fadilah, Rizal Fazrin, Rifki Rizkullah Febi Ariefka Septian Putra Fikri Sofhani Habinuddin, Endang Handayani Nur Jamilah Hasan Surya Icha Marsya Ramadhani Ichwan Latif Fajari Ilman, Sofyan M. Kartono W. Kasni Sumeru Kumar, Saurav Laras Nurul Syamsy Mauludin, Luthfi Muhammad Melisa Mulyadi Mohamad Firdaus bin Sukri Mufidi, M. Faiz Muhamad Alwi Muhamad Fahmy Muhammad Akmal Muhammad Reihan Iskandar Mujiman Mujiman, Mujiman Muliawan, Rizki MULYONO, NANANG Nabila, Edlyna Syahda Neni Emrida Panjaitan Nisrina Nurul Fadlilah Nuriyadi, Muhammad Nurohmah, Restu Nuryati, Neneng Pramudantoro, Triaji Pangripto Putra, Pahreza Ridwan Putri, Amelia Ocktriviani Rena Reinita Ridwan Solihin Robert Adriaan Philipus Robert Adrian Rully Syahrul Mucharom, Rully Syahrul Sapto Prajogo Shodiya Sulaimon Sirait, Togar SISWOYO Sofian Yahya Sophia Latifah Aulia Sri Nugroho SRI UTAMI Sudrajat Sudrajat Sudrajat Sudrajat SUNARTO Sunarto Sunarto Sunarto Sunarto Supriyadi, Tata Supriyanto Supriyanto Suhono Supriyanto Supriyanto Susanto Susanto Syarif Hidayat Trisnawiyana Trisnawiyana Trisnawiyana, Trisnawiyana Utomo, Heru Budi Wiguna, Tessa Ananta Wijayanti, Linda Winata, Moh Tomi Yosep Santosa Yoseph Santosa Yudi Prana Hikmat