Claim Missing Document
Check
Articles

MODIFIKASI PANEL KONTROL SISTEM PENYEDIA AIR DINGIN PADA SISTEM VENTILASI ZONA RADIASI MENENGAH Paulus Sihombing; Nur Hanifah Yuninda; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 2 No 1 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0021.02

Abstract

This research aims to design and make modifications to the control panel of cold water supply system in the ventilation system into the radiation zone semi-automatic medium so as to increase the value of the effectiveness and efficiency of the operation pattern 3 cold water supply system. This study uses research and development and implemented in PRSG GAS BATAN, PUSPIPTEK SERPONG in november 2015 until June 2016. Modification of the control panel is used, CDAQ NI 9132, NI 9205, and 14.0 Labview software which will display chiller work in real time in graphs and nominal. Hardware input consists of, selector to choose the working water supply system cold, RTD PT100 as readers temperature of water entering the inlet pipe and the temperature of the water that comes out of the chiller, and sensor current transformer as a reader of electric current in the circulation pump, the output device is composed of pilot working as an indication lamp chiller and a thermostat to control the chiller via the inlet pipe. The steps to create the control panel modification of the draft, the control panel wiring, wiring input NI 9205, a program in Labview, then perform tests on the device. Based on the results of testing known that the thermostat is able to control the chiller in accordance with the limits of the temperature setting on the thermostat. In the test results of pembacan incoming water temperature at the inlet pipe through the display labview program has a percentage error of 0.52%, while data readings out of the water temperature chiller 1 has a percentage of the reading error of 0.57%, the second chiller is 0 , 41% and chiller 3 is 0.45% and the data of electric current readings on the circulation pump shown in labv iew program has a percentage of error of 1.24% in chiller 1, and 1.62% in the chiller 2, and 1.27% the chiller 3. Once the system has been tested as a whole, so that it can be concluded that the modification of the control panel of the cold water supply system can work properly according to the principles of work that has been made Abstrak Sistem penyedia air dingin yang berjumlah 3 unit pada PRSG GAS BATAN sebagai penghasil air dingin memiliki pola pengoperasian secara manual yang kurang efektif dan efesisen sehingga kurang optimal. Penelitian ini bertujuan untuk merancang dan membuat modifikasi panel kontrol sistem penyedia air dingin pada sistem ventilasi zona radiasi menengah menjadi semi otomatis sehingga dapat meningkatkan nilai efektifitas dan efesiensi dari pola pengoperasian 3 sistem penyedia air dingin. Penelitian ini menggunakan metode penelitian dan pengembangan dan dilaksanakan di PRSG GAS BATAN, PUSPIPTEK SERPONG pada bulan november 2015 sampai juni 2016. Modifikasi panel kontrol ini menggunakan, CDAQ NI 9132, NI 9205, dan software Labview 14.0 yang akan menampilkan kerja chiller secara real time dalam bentuk grafik dan nominal. Peralatan input terdiri dari, selektor untuk memilih kerja sistem penyedia air dingin, RTD PT100 sebagai pembaca suhu air yang masuk pada pipa inlet dan suhu air yang keluar dari chiller, dan sensor current trafo sebagai pembaca listrik pada pompa sirkulasi, peralatan output terdiri dari pilot lamp sebagai indikasi kerja chiller dan thermostat untuk mengontrol chiller melalui pipa inlet. Langkah-langkah pembuatan modifikasi panel kontrol dari membuat rancangan, wiring panel kontrol, wiring input NI 9205, program pada Labview, kemudian melakukan uji coba pada alat. Berdasarkan hasil dari pengujian diketahui bahwa thermostat mampu mengontrol chiller sesuai dengan batas setting suhu pada thermostat. Pada hasil pengujian dari pembacan suhu air yang masuk pada pipa inlet melalui tampilan program labview memiliki presentase kesalahan sebesar 0,52%, sedangkan data hasil pembacaan suhu air keluar dari chiller 1 memiliki presentase kesalahan pembacaan sebesar 0,57%, pada chiller 2 ialah 0,41% dan chiller 3 ialah 0,45% dan data hasil pembacaan listrik pada pompa sirkulasi yang ditampilkan dalam program labview memiliki presentase kesalahan 1,24% pada chiller 1, dan 1,62% pada chiller 2, dan 1,27% pada chiller 3. Setelah sistem diuji secara keseluruhan, sehingga dapat disimpulkan bahwa modifikasi panel kontrol sistem penyedia air dingin dapat bekerja dengan baik sesuai prinsip kerja yang telah dibuat
PENINGKATAN EFESIENSI ENERGI GEDUNG L2 FAKULTAS TEKNIK UNIVERSITAS NEGERI JAKARTA MELALUI AUDIT ENERGI KELISTRIKAN DALAM RANGKA DETEKSI DINI TERHADAP BAHAYA KEBAKARAN Massus Subekti; Irzan Zakir; Imam Arif Raharjo
Journal of Electrical Vocational Education and Technology Vol 2 No 1 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0021.04

Abstract

Abstract This study aims to identify the magnitude of energy consumption currently used and identify all possible energy savings including detecting all possible fire hazards based on audit data obtained using Power Quality Analizer (PQA) and Thermal Imager. The methods included include: collection and introduction of historical data, calculating IKE, measuring real power (kW) / apparent power (kVA), power factor, maximum / minimum frequency, voltage / current between phases, voltage / load unbalance, voltage harmonic / flow, checking Energy Consumption Intensity (IKE), recognizing the possibility of Energy Saving Opportunities (PHE), analyzing PHE, Making PHE recommendations and implementing PHE in the field to obtain the value of Energy Consumption Instances according to standards. Based on the measurement results show the carrying frequency, voltage fluctuations, voltage harmonics, and voltage imbalances are still in accordance with the standard. So that it can be concluded that the Faculty of Engineering, Jakarta State University, is still safe from the danger of building fires. Abstrak Penelitian ini bertujuan dilakukan guna mengidentifikasi besarnya konsumsi energi yang saat ini digunakan dan mengidentifikasi segala kemungkinan penghematan energy termasuk mendeteksi segala kemungkinan bahaya kebakaran berdasarkan data audit yang diperoleh dengan menggunakan Power Quality Analizer (PQA) dan Thermal Imager. Metode yang dilakukan meliputi: pengumpulan dan penyusuan data historis, menghitung IKE, melakukan pengukuran daya nyata (kW)/daya semu (kVA), faktor daya, frekwensi maksimum/minimum, tegangan/ antar phasa, unbalance tegangan/beban, harmonik tegangan/ , pemeriksaan Intensitas Konsumsi Energi (IKE), mengenali kemungkinan Peluang Hemat Energi (PHE), menganalisa PHE, Membuat rekomendasi PHE serta mengimplementasikan PHE dilapangan guna mendapatkan nilai Instensitas Konsumsi Energi sesuai standar. Berdasarkan hasil pengukuran menunjukkan bawa frekuensi, fluktuasi tegangan ,harmonisa tegangan, dan ketidakseimbangan tegangan masih dalam sesuai dengan standar . Sehingga dapat disimpulkan bahwa Fakultas Teknik Universitas Negeri Jakarta dari sisi kelistrikan masih aman dari bahaya kebakaran gedung.
PENGEMBANGAN ALAT DESINFEKSI AIR MINUM DENGAN UVGI (ULTRAVIOLET GERMECIDAL IRRADIATION) BERBASIS ARDUINO Harmawan Febrianto; Massus Subekti; Nur Hanifah Yuninda
Journal of Electrical Vocational Education and Technology Vol 2 No 1 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0021.01

Abstract

The purpose of this study is to make a drinking water desinfector device by irradiating ultraviolet light (UV) based on Arduino. The device can provide information specific to large-intensity UV lamps in optimal perfomance to desinfection drinking water, as well as a signal to the operator if, the intensity of the UV lamps has decreased resulting in water flow will be closed automatically controlled by on Arduino. This study uses a method of Research and Development (Research and Development), which includes planning, requirements analysis, design, and implementation of the system. System requirements necessary in this study are ultraviolet sensor that can measure the magnitude and intensity of ultraviolet rays water rate sensor to measure the flow rate of water entering on this instrument. In this case serves to monitor the UV lamp specifically keoptimalan and Arduino will process the input results for the solenoid valve opens automatically and gives an alarm signal to the operator. These results indicate that the instrument disinfection of drinking water with UVGI-based Arduino has managed to work out where these tools can provide large information intensity of UV rays as well, can give an alarm signal to the operator and the control solenoid valve in order to shut off the flow of water automatically as a follow security if not in accordance with a predetermined set point, namely at the point of maximum 978 lux with a water flow rate 3 L / min based microbial testing in the laboratory. At this point is the most optimal point in reducing bacteria which amounted to 94.57% or the remaining 25 colonies / ml of the total number of bacteria before exposed to UV light that is 460 colonies / ml. It is adjusted by the standard (SNI 7388: 2009-14.1.1.2) with a maximum limit of microbial contamination in drinking water is 100 colonies / ml. Abstrak Tujuan penelitian ini adalah membuat suatu alat desinfeksi air minum dengan penyinaran lampu ultraviolet (UV) berbasis Arduino. Alat ini dapat memberikan informasi secara spesifik terhadap besar intesitas lampu UV dalam keoptimalannya untuk medesinfeksikan air minum, serta memberikan sinyal kepada operator apabila, intesitas lampu UV telah menurun dan akan mengakibatkan aliran air akan tertutup secara otomatis yang dikendalikan dengan Arduino. Penelitian ini menggunakan Metode Penelitian dan Pengembangan (Research and Development) yang meliputi perencanaan, analisis kebutuhan, perancangan, dan implementasi sistem. Kebutuhan sistem yang diperlukan pada penelitian ini adalah : sensor ultraviolet yang dapat mengukur besar intesitas sinar ultraviolet dan sensor laju air untuk mengukur kecepatan aliran air yang masuk pada alat ini. Dalam hal ini berfungsi memantau keoptimalan lampu UV secara spesifik serta Arduino akan memproses hasil input tersebut untuk membuka solenoid valve secara otomatis dan memberikan sinyal alarm kepada operator. Hasil penelitian ini menunjukan bahwa alat desinfeksi air minum dengan UVGI berbasis Arduino telah berhasil bekerja dimana alat ini dapat memberikan informasi besar intesitas sinar UV serta, dapat memberikan sinyal alarm kepada operator dan mengendalikan solenoid valve agar bisa menutup aliran air secara otomatis sebagai tindak keamanan jika tidak sesuai dengan set point yang telah ditentukan, yakni pada titik maksimal 978 lux dengan kecepatan aliran air 3 L/min berdasarkan pengujian mikroba di laboratorium. Pada titik ini adalah titik yang paling optimal dalam mereduksi bakteri yakni sebesar 94,57% atau tersisa 25 Koloni/ml dari angka total bakteri sebelum disinari sinar UV yakni 460 koloni/ml . Hal ini disesuaikan oleh standar (SNI 7388:2009-14.1.1.2) dengan batas maksimum cemaran mikroba pada air minum sebesar 100 koloni/ml.
RANCANG BANGUN TURBIN UAP PADA MAKET PEMBANGKIT LISTRIK TENAGA UAP Muhamad Rizky Septianto; Massus Subekti; Daryanto
Journal of Electrical Vocational Education and Technology Vol 2 No 2 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0022.08

Abstract

The purpose of this study was to produce a prototype steam turbine at maket power plant steam generator torque that can play. The research method used in this research is descriptive analysis by type of engineering. Steam turbine is a Primemover that converts potential energy into mechanical energy in the form of rotation of the turbine shaft. Steam turbine constructed dimensions turbine type used single stage impulse turbine, turbine disc diameter of 33mm, the amount of movement of the blade 30 pieces, the distance between the blade 14,6mm, radious 2,63mm blade, the type of nozzle used convergent, area 3,2cm2 neck cross-section, the cross sectional area of 3,2cm2 side exit. Mockups of the steam turbine can generate 1490 rpm for turbine with a steam generator at a pressure of 4 kg/cm2 using a water volume of 19 liters. Maximum pressure that can be accepted by the steam turbine is 8 kg/cm2 with 11.000rpm, produced according to the process of heating boiler which is the maximum vapor pressure of 8kg/cm2 at a temperature of 1700C. and and be able to turn a generator with a torque of 4.6 Nm with a pressure of 8 kg/cm2 The conclusion of this study is the turbine can be built through the calculations have been carried out and taking into account the performance of the boiler and steam generator.Turbin built to produce 1336.6 rpm to spin the turbine without the steam generator at a pressure of 2 kg / cm2. Steam turbines are built to produce 1408 rpm, and generates a voltage 140.8 volts, and be able to play generatoe torque of 0.6 Nm for turbine with the steam generator at a pressure of 4 kg / cm2. Maximum pressure received by the steam turbine is 8 kg / cm2 at 10 453 rpm for the turbine without a generator, and a voltage of 271.8 volts produces, as well as being able to roll generatoe torque of 0.9 Nm for turbine with a generator on the vapor pressure of the incoming sebesae 8 kg / cm2. Abstrak Tujuan dari penelitian ini adalah untuk menghasilkan prototipe turbin uap yang mampu memutar torsi generator. Metode penelitian yang dipakai dalam penelitian ini adalah analisis deskriptif dengan jenis rekayasa teknik. Turbin uap (steam turbine) adalah penggerak mula yang merubah energi potensial menjadi energi mekanis dalam bentuk putaran poros turbin. Turbin uap yang dibangun memiliki dimensi jenis turbin yang digunakan turbin impuls single stage, cakram turbin berdiameter 33 mm, jumlah sudu gerak 30 buah, jarak bagi antar sudu 14,6mm, jari–jari sudu 2,63mm, jenis nosel yang digunakan konvergen, luas penampang leher 3,2cm2, luas penampang sisi keluar 3,2cm2. Maket turbin uap tersebut dapat menghasilkan 1490 rpm untuk putaran turbin dengan generator pada tekanan uap 4 kg/cm2 menggunakan volume air 19 liter. Tekanan maksimal yang mampun diterima oleh turbin uap ini adalah 8 kg/cm2 dengan 11.000rpm, sesuai yang dihasilkan pada proses memanasan boiler yaitu tekanan uap maksimalnya adalah 8kg/cm2 pada suhu 170oC. serta mampu memutar generator dengan torsi 4,6 N dengan tekanan 8 kg/cm2. Kesimpulan dalam penelitian ini adalah turbin dapat dibangun melalui perhitungan yang telah dilakukan dan dengan mempertimbangkan unjuk kerja antara boiler dan generator.Turbin uap yang dibangun dapat menghasilkan 1336,6 rpm untuk putaran turbin tanpa generator pada tekanan uap 2 kg/cm2. Turbin uap yang dibangun dapat menghasilkan 1408 rpm, dan menghasilkan tegangan 140,8 volt, serta mampu memutar torsi generatoe sebesar 0,6 Nm untuk putaran turbin dengan generator pada tekanan uap 4 kg/cm2. Tekanan maksimal yang diterima oleh turbin uap ini adalah 8 kg/cm2 dengan 10.453 rpm untuk putaran turbin tanpa generator, dan menghasilkan tegangan 271,8 volt, serta mampu memutar torsi generatoe sebesar 0,9 Nm untuk putaran turbin dengan generator pada tekanan uap yang masuk sebesae 8 kg/cm2.
PENGARUH VARIASI BENTUK DAN UKURAN PONTON TERHADAP KETINGGIAN AIR Rotua Bebrianita Palentina; Muhammad Rif’an; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.07

Abstract

Abstract. This study aims to determine the influence of the shape and size of the buoy to the height of the air.The research method used is the method of development. Development of PLTA-GL.By changing the shape of the buoy with 3 variations of form, ie: kubu, tube, and ball but the volume size is fixed and by changing the size of buoy with 3 variationd size of from; 0,1m3, 0,125m3, dan 0,15m3 but the shape is fixed. From the research results obtained that the highest water level on the buoy ball with 0,15m3 whit water height of 28,1575251 meters and the lowest water level is on the buoy shaped cubes with volume 0,1m3with water level of 14,01078389 meters Abstrak Penelitian ini bertujuan untuk mengetahui pengaruh bentuk dan ukuran ponton terhadap ketinggian air. Metode penelitian yang digunakan merupakan metode Pengembangan. Pengembangan dilakukan Pada Pembangkit Tenaga Air-Laut (PLTA-GL). Dengan mengubah-ubah bentuk ponton dengan 3 variasi bentuk yaitu, kubus, tabung, dan bola namun ukuran volume tetap dan dengan mengubah-ubah variasi ukuran volume ponton ke dalam 3 variasi yaitu; 0,1m3, 0,125m3, dan 0,15m3 namun bentuk tetap. Dari hasil penelitian di dapatkan bahwa ketinggian air tertinggi pada ponton bola dengan volume 0,15 m3 dengan ketinggian air sebesar 28,1575251 meter, dan ketinggian air terendah terdapat pada ponton kubus dengan volume 0,1 m3 dengan ketinggian air sebesar 14,01078389 meter.
PENGARUH KETEBALAN BATU ANDESIT TERHADAP KELUARAN TERMOELEKTRIK Ary Akbar Nugraha; Massus Subekti; Imam Arif Rahardjo
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.05

Abstract

Abstract. This research aimed to create and utilize video-based learning media on motor control course and also to determine whether the video-based learning media on motor control course is effective or not. The making of the video-based learning media using several stages, namely, literature study, analysis needs, product planning, product making, instrument making feasibility and feasibility studies that are conducted by the experts, media specialists and students in order to determine the feasibility of the media created. Furthermore, to test the effectiveness of video-based learning media on motor control course, students are given the post- test questions that the validity and reliability have previously been tested by using an experimental model. The results of the feasibility test got a score > 80%, subject experts got a score of 94.23%, media experts 91,66%, and students 86.13%. The results of the feasibility test obtained, video-based learning media on motor control course is said to be very good and fit for use as a media of learning. The average value of students post test using a video-based learning media is 83, while students who do not use a video-based learning media have an average of 80.56. These data showed that value of post test results of motor control course that uses video-based learning media is higher than value of post test results that does not use a video-based learning media. The difference in post test results show that a video-based learning media on motor control course is an effective media of learning. Abstrak Tujuan penelitian ini adalah untuk mengetahui pengaruh ketebalan batu andesit terhadap keluaran termoelektrik. Penelitian ini menggunakan metode penelitian eksperimen dengan pendekatan kuantitatif. Subjek penelitian ini ialah ketebalan batu andesit. Ketebalan batu andesit yang digunakan yaitu ketebalan 1 cm, 2 cm, dan 3 cm. Penelitian ini dilakukan pengujian laju kalor konduksi dan keluaran termoelektrik berdasarkan ketebalan batu andesit. Teknik analisis data yang digunakan yaitu analisis deskriptif dengan teknik pengumpulan data yaitu observasi laboratorium dan observasi lapangan. Hasil penelitian ini menunjukkan bahwa batu andesit ketebalan 1 cm menghasilkan laju kalor konduksi tertinggi dibandingkan ketebalan 2 cm dan 3 cm. Begitu juga dengan keluaran yang dihasilkan termoelektrik. Batu andesit ketebalan batu 1 cm menghasilkan keluaran paling besar dibandingkan ketebalan batu 2 cm dan 3 cm. Tegangan keluaran V0 (tanpa beban) dan V1 (dengan hambatan 100 ohm) yang dihasilkan termoelektrik pada ketebalan batu 1 cm berturut- turut sebesar 1.40 V dan 1.08 V, ketebalan batu 2 cm sebesar 1.37 V dan 0.98 V, dan ketebalan batu 3 cm sebesar 1.22 V dan 0.94 V. Berdasarkan hasil data pengujian tersebut dapat disimpulkan bahwa ada pengaruh ketebalan batu andesit terhadap keluaran termoelektrik.
PENGARUH KELEMBABAN TANAH TERHADAP TAHANAN PENTANAHAN STUDI KASUS PADA GARDU INDUK KEMAYORAN 150 kV Rahmawati Fajri Latiefa; Irzan Zakir; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.04

Abstract

Abstract The value of grounding resistance at the substation should be 0 Ω or less than 1 Ω. The value of grounding resistance is influenced by the resistivity and the grounding system method used. the resistivity is influenced by external factors, one of which is the soil moisture. The purpose of this research are (i) to find the effect of soil moisture to grounding resistance with; (a) compare the actual measurements of grounding resistance between wet soil conditions and dry soil conditions; (b) compare actual measurement results, manual calculations, and ETAP 12.6 software on grid resistance between wet soil conditions and dry soil conditions. (ii) to find the effect that would occur if the grounding station resistance exceeds the IEEE Std 80-2000 standard value of less than 1 Ω. The research method is comparative quantitative. This research is measuring grounding resistance with driven rood system and with grid system during wet and dry soil conditions, and then calculate grid resistance of Kemayoran 150 kV Substation in dry and wet soil conditions using manual calculating based on IEEE Std 80 -2000, and calculating using ETAP 12.6 software. The result of measument grounding resistance with driven rood system show the value of grounding resistance is 27,72 Ω when dry soil condition and 18,92 Ω when wet soil condition, the measurement result of grounding resistance with grid system show the value of grounding resistance is 0.076 Ω when the soil condition is dry and 0.049 Ω during wet soil conditions, the manual calculation of grid resistance is 0.078 Ω for dry soil conditions and 0.056 Ω, and the ETAP calculation of grid resistance is 0.071 Ω for dry soil conditions and 0.051 Ω for wet soil conditions. Based on the results of this research, the conclusion is soil moisture can affect the value of grounding resistance, based on this research the dry soil condition of the earth resistance value is higher than the wet soil conditions. The value of earthquake grounding shall be less than 1 Ω due to minimize the earth potenial value (Ground Potensial Rise) which can cause dangerous voltage for humans. Abstrak Nilai tahanan pentaahan pada Gardu Induk harus mendekati 0 Ω atau kurang dari 1 Ω, dan dipengaruhi oleh tahanan jenis tanah dan metode sistem pentanahan yang digunakan. Tahanan jenis tanah dipengaruhi oleh faktor eksternal, salah satunya adanya kelembaban tanah. Tujuan dari penelitian ini adalah mengetahui pengaruh kelembaban tanah terhadap nilai tahanan pentanahan, dan mengetahui pengaruh yang akan terjadi jika tahanana pentanahan gardu induk melebihi nilai standar IEEE Std 80-2000 yaitu kurang dari 1 Ω. Penelitian ini melakukan pengukuran aktual tahanan pentanahan dengan sistem driven rood dan tahanan pentanahan dengan sistem grid saat kondisi tanah basah dan tanah kering, serta perhitungan tahanan pentanhan grid Gardu Induk Kemayoran 150 kV dalam kondisi tanah kering dan tanah basah dengan menggunakan perhitungan manual berdasarkan IEEE Std 80-2000, dan perhitungan menggunakan software ETAP 12.6. Dalam penelitian ini ditemukan bahwa kelembaban tanah dapat mempengaruhi nilai tahanan pentanahan, dengan berdasarkan saat kondisi tanah kering nilai tahanan pentanahan lebih tinggi dibandingkan saat kondisi tanah basah Hasil pengukuran tahanan pentanahan dengan sistem driven rood menunjukkan nilai tahanan pentanahan adalah 27,72 Ω saat kondisi tanah kering dan 18,92 Ω saat kondisi tanah basah, hasil pengukuran tahanan pentanahan dengan sistem grid menunjukkan nilai tahanan pentanahan adalah 0,076 Ω saat kondisi tanah kering dan 0,049 Ω saat kondisi tanah basah, hasil perhitungan manual tahanan grid adalah 0,078 Ω untuk kondisi tanah kering dan 0,056 Ω, dan hasil perhitungan ETAP tahanan grid adalah 0,071 Ω untuk kondisi tanah kering dan 0,051 Ω untuk kondisi tanah basah.
ANALISIS PERBANDINGAN TINGKAT AKURASI AVOMETER SEKOLAH MENENGAH KEJURUAN DENGAN DUNIA USAHA DAN INDUSTRI MENGGUNAKAN MC5 Reymond Alexander; Parjiman; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.06

Abstract

Abstract For measurement of voltage, the avometer that meets the standard of the tolerance limits set by the user of calibration measurements with MC5 is 17 avometer samples (89.5%) of the 19 samples avometer studied, including 9 avometer SMK and 8 avometers World Business Partners and Industries. For the measurement of the current, the avometer that meets the standards of the tolerance limits set by the user guide of each avometer at the time of calibration measurements with MC5 is 14 avometer samples (73.68%) of 19 samples avometer studied, including 6 avometer SMK and 7 avometers World Business Partners and Industries.. 3 pieces of avometer or 30% of which have exceeded the tolerance limit set by the manufacturer standard in the manual (user guide). From all the avometer samples that have been studied both analog and digital avometers available in Business Partners and Industries it can be concluded that 7 sample avometers (77.8%) that meet all the standards of tolerance limits set by the user guide are each avometer of flat the measurement of the voltage, current, and resistance of the 9 samples of the avometer studied. 2 pieces of avometer or 22.2% of them have exceeded the tolerance limit set by the manufacturer standard in the manual (user guide). Abstrak Untuk pengukuran tegangan, avometer yang memenuhi standar dari batas toleransi yang telah ditetapkan menurut user guide masing – masing avometer pada saat dilakukan pengukuran kalibrasi dengan MC5 yaitu 17 buah sample avometer (89,5%) dari 19 sample avometer yang diteliti, diantaranya 9 avometer SMK dan 8 avometer Dunia Mitra Usaha dan Industri. Untuk pengukuran arus, avometer yang memenuhi standar dari batas toleransi yang telah ditetapkan menurut user guide masing – masing avometer pada saat dilakukan pengukuran kalibrasi dengan MC5 yaitu 14 buah sample avometer (73,68%) dari 19 sample avometer yang diteliti, diantaranya 6 avometer SMK dan 7 avometer Dunia Mitra Usaha dan Industri. Untuk pengukuran hambatan, avometer yang memenuhi standar dari batas toleransi yang telah ditetapkan menurut user guide masing – masing avometer pada saat dilakukan pengukuran kalibrasi dengan MC5 yaitu 16 buah sample avometer (84,2%) dari 19 sample avometer yang diteliti, diantaranya 8 avometer SMK dan 8 avometer Dunia Mitra Usaha dan Industri. Dan dari 7 sample avometer (70%) yang memenuhi semua standar dari batas toleransi yang telah ditetapkan menurut user guide masing–masing avometer dari rata-rata pengukuran tegangan, arus, maupun hambatan dari 10 sampel avometer yang diteliti. 3 buah avometer atau 30% diantaranya sudah melewati batas toleransi yang telah ditetapkan standar pabrikan dalam buku manual (user guide). Dari semua sample avometer yang telah diteliti baik avometer analog maupun digital yang ada di Mitra Usaha dan Industri dapat disimpulkan bahwa 7 sample avometer (77,8%) yang memenuhi semua standar dari batas toleransi yang telah ditetapkan menurut user guide masing–masing avometer dari rata-rata pengukuran tegangan, arus, maupun hambatan dari 9 sampel avometer yang diteliti. 2 buah avometer atau 22,2% diantaranya sudah melewati batas toleransi yang telah ditetapkan standar pabrikan dalam buku manual (user guide).
PENGARUH PENERIMAAN TEKNOLOGI INFORMASI DAN KOMUNIKASI TERHADAP EFEKTIVITAS MANAJEMEN SEKOLAH DARYANTO; Parjiman; Massus Subekti
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.09

Abstract

Abstract. The success of the adoption (adoption) of Information and Communication Technology (ICT) in education management is determined by the technological and organizational aspects. The technological aspect in question is user behavior which includes perceptions of the usefulness and ease of ICT, attitudes, intentions, and actual use. While the organizational aspect is the ability of management to develop the application of ICT to support the school management function. This study aims to develop ICT acceptance models in improving school management. New innovations in the development of the ICT acceptance model at Open SMP were carried out through a survey of 29 Open SMPs in DKI Jakarta with 178 respondents. Literature study and empirical study through observation were carried out to produce findings of factual models of the use of ICT in the targeted Open Junior High School. Based on the factual model, a development model design and development model are formulated. Then a group discussion is held to validate the design of the initial model. The next step is to make improvements to the model based on the results of the discussion of the group to produce a hypothetical model. The results showed that the acceptance of ICTs had a positive and significant effect on the effectiveness of school management in Open Junior High Schools (SMPT) in DKI Jakarta. While perceptions of ease of use of ICTs have a very low effect on perceptions of uses, attitudes to use ICTs, and behavioral intentions in using ICTs in Open Junior High Schools (SMPT) in DKI Jakarta, although the influence exerted remains positive and significant. Based on this, there is a need for reform and repositioning of perceptions and attitudes in the use of ICTs. Abstrak Keberhasilan penerimaan (adopsi) Teknologi Informasi dan Komunikasi (TIK) dalam manajemen pendidikan ditentukan oleh aspek teknologi dan organisasi. Aspek teknologi yang dimaksud adalah perilaku pengguna yang meliputi persepsi terhadap kegunaan dan kemudahan TIK, sikap, niat, dan penggunaan yang sebenarnya. Sedangkan aspek organisasi merupakan kemampuan manajemen untuk mengembangkan penerapan TIK untuk mendukung fungsi manajemen sekolah. Penelitian ini bertujuan untuk mengembangkan model penerimaan TIK dalam meningkatkan manajemen sekolah. Inovasi baru dalam pengembangan model penerimaan TIK di SMP Terbuka dilakukan melalui survei di 29 SMP Terbuka yang ada di DKI Jakarta dengan responden sebanyak 178 orang guru. Studi kepustakaan dan kajian empirik melalui observasi dilakukan untuk menghasilkan temuan model faktual pemanfaatan TIK di SMP Terbuka yang menjadi sasaran. Berdasarkan model faktual tersebut kemudian dirumuskan desain model pengembangan dan menyusun perangkat model. Selanjutnya dilakukan kegiatan diskusi kelompok terpumpun untuk memvalidasi desain model awal. Langkah berikutnya adalah melakukan perbaikan model berdasarkan hasil diskusi kelompok terpumpun tersebut untuk menghasilkan model hipotetik. Hasil penelitian menunjukkan bahwa penerimaan TIK berpengaruh secara positif dan signifikan terhadap efektifitas manajemen sekolah di Sekolah Menengah Pertama Terbuka (SMPT) di DKI Jakarta. Sedangkan persepsi kemudahan dalam penggunaan TIK berpengaruh sangat rendah terhadap persepsi kegunaan, sikap untuk menggunakan TIK, dan niat perilaku dalam menggunakan TIK di Sekolah Menengah Pertama Terbuka (SMPT) di DKI Jakarta, meskipun pengaruh yang diberikan tetap positif dan signifikan. Berdasarkan hal tersebut perlu adanya reformasi dan reposisi persepsi serta sikap dalam penggunaan TIK.
PENGEMBANGAN MODUL ELEKTRONIK BERBASIS LECTORA INSPIRE PADA MATA PELAJARAN INSTALASI MOTOR LISTRIK Hervina Kiruna; Massus Subekti; Purwanto Gendroyono
Journal of Electrical Vocational Education and Technology Vol 3 No 1 (2018): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0031.03

Abstract

The aims of this study are to : (1) find the necessity of electronic module, (2) find the process of the development module, (3) find the expediency, and (4) find the effectiveness of the electronic module based on Lectora Inspire on the subject Electric Motor Installation. The research method used is Research and Development method, while the product development model uses the ADDIE (Analysis,Design, Development, Implementation, and Evaluation). This study uses questionnaire and questions test as the technique of collection data. The results of the study find that : (1) the analysis of the necessity of electronic module shows that as many 100% of the students have not used the electronic module yet, (2) the process of developing the learning as module is done in fivemain stages, which are Analysis,Design, Development, Implementation, and Evaluation, (3) feasibility testing is obtained on average 3,5 with the criteria “Very feasible” and concludes that the electronic module based on Lectora Inspire on teh subject Electric Motor Installation is feasible for learning., and (4) the effectiveness test is done by comparing the posttest grade of the experimental class with the posttest grade of the control class has the result of Tcount = 5,74 with the conlusion that the effectiveness of the use of Electronic Module based Lectora Inspire is higher or equal to the students that do not use the module in improving the learning outcomes of Electronic Motor Installation. Abstrak Penelitian ini bertujuan untuk: (1) mengetahui kebutuhan modul elektronik (2) mengetahui proses pengembangan modul, (3) mengetahui kelayakan dan (4) mengetahui keefektifan modul elektronik berbasis Lectora Inspire pada mata pelajaran Instalasi Motor Listrik. Metode penelitian yang digunakan adalah metode penelitian dan pengembangan (Research & Development) sedangkan model pengembangan produk yang digunakan adalah model ADDIE (Analysis,Design,Development,Implementation, dan Evaluation). Teknik pengumpulan data pada penelitian ini menggunakan angket dan soal tes. Hasil penelitian menunjukan bahwa: (1) analisis kebutuhan mengatakan sebanyak 100% siswa belum menggunakan modul elektronik (2) proses pengembangan modul pembelajaran dilakukan dalam lima tahapan utama yaitu Analysis,Design,Development,Implementation, dan Evaluation; (3) pengujian kelayakan didapatkan rata-rata 3,5 dengan kriteria “sangat layak” dan modul elektronik berbasis Lectora Inspire pada mata pelajaran Instalasi Motor Listrik layak digunakan untuk proses pembelajaran; dan (4) pengujian keefektifan dilakukan dengan membandingkan nilai posttest kelas eksperimen dengan nilai posttest kelas kontrol didapatkan hasil nilai
Co-Authors Achmad Abi Rafdi Adung Prawira Adinata Ady Wartono Ahmad Hambali, Ahmad Ahmad Ramadhan Putra Amanda, Early Ardianto, Agus Ari Saputra, Ari Aris Sunawar Aris Sunawar Sunawar Aris Sunawar, Aris Ary Akbar Nugraha ARY AKBAR NUGRAHA Azhari Jum’atullah Bayu Prabowo Bayu Suryo Wiranto Brenden F.I Chaerul Rozikin Daryanto Daryanto Daryanto Daryanto Deffi Meidiasha DENY KURNIAWAN Dewi Rahmawati Diah Yuni Purwitaingsih Diarsyah Amarullah Djaohar, Mochammad Dwi Setyawan Eka Mardiana Eka Nur Wulandari Faried Wadjdi Farried Wadjdi Fijrianto, Ari Jodiansyah Fiyanto, Roy Oktaf Galang A F Galang Adi F Gendroyono, Purwanto Hadi Nasbey Hajar Nur Qibtyah Hanum Isfaeni Harmawan Febrianto Hervina Kiruna Hidayat, Rahmat Nur Hikmatul Mardiyah Hogan, Stevent Imam A. Rahardjo Imam Arif R IMAM ARIF RAHARDJO Imam Arif Raharjo Imam Arif Raharjo Imam Mahir Irzan Zakir Irzan Zakir Irzan Zakir Irzan Zakir Zakir Izzah Nur Maulidah Abdul Salam Izzani, Sabila Fiqra Lutfiah, Tia M Djaohar M Sami M. Djaohar M. Febrian Ristiyanto M. Rif’an Maria Michelle Cindy Maya Firanti Putri Mochammad Djaohar Monantun, Readysal Muhamad Rizky Septianto Muhammad Iqbal Muhammad Rifan Muhammad Rifan Muhammad Rif’an Muhammad Rif’an Muhammad Rif’an Rif’an Muksin Nasruloh, Agan Nur Hanifah Nur Hanifah Yuninda Nur Octaviani Nuraini, Syifa Nuvita Retna Sari Parjiman Parjiman Parjiman Parjiman Paulus Sihombing Permana, Yusuf A Priyono Purwanto Gendroyono Putriansyah Rahardjo, Imam Arif Raharjo, Imam Arif Rahmawati Fajri Latiefa Raja Ingan Budi Rega Sundawa Putra Reymond Alexander Rian Pratama Rifani, Mohammad Arif Rizqy Zaputra, Dhafin Rotua Bebrianita Palentina Rozikin, Chaerul Rudy Prihantoro Sakirah Shanty Muflihawati Siahaan, David Kevin Immanuel Silvia, Chendy Slamet Raharjo Soeprijanto Soeprijanto Suyitno Suyitno Suyitno Sya’bani, Bagus Fajar Syah, Tim Abyah Syifa Nuraini Syufrijal, Syufrijal Wibawa, Bayu Addysa Wibisono, Salsa Alifianti Widodo Widodo