PLC Implementation as a Flow Computer for Calculation of Saturated Steam Mass Meetings with the Linear Divided Regression Method (Application: PT. XYZ - Kuala Tanjung) Dedy AP; Muhammadi Fitra Zambak; Ahmad AA; Suwarno Suwarno
Journal of Computer Science, Information Technology and Telecommunication Engineering Vol 1, No 1 (2020)
Publisher : Universitas Muhammadiyah Sumatera Utara, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (384.883 KB) | DOI: 10.30596/jcositte.v1i1.4361

Abstract

In supporting of production quality improvement, industry must be supported by reliable process system. Reliable measurement system also included in one system which is expected realibility. Specially for saturated steam flow measurement and calculation which is mostly done in the industry in relation to control production cost, should also be able to show accurate results. Now PLC has taken an important role in industry, beside as a control system, PLC also can be used to calculation a formula. This paper aims to use PLC as flow computer to calculate saturatedsteam density by adopting linear regression method which is divided into “n” section to increase the accuration with pressure as a input parameter. The results show a relatively small error value around 0,2% if we compare with standart linear regression method, where the value around 0,9%.
Monitoring of Electrical Energy during the Covid-19 Pandemic Using SMS on Microcontrollers Muhammad Fitra Zambak
Journal of Computer Science, Information Technology and Telecommunication Engineering Vol 1, No 2 (2020)
Publisher : Universitas Muhammadiyah Sumatera Utara, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (647.148 KB) | DOI: 10.30596/jcositte.v1i2.4968

Abstract

PT. PLN (Persero) has been getting prepaid and postpaid electricity program services, but in postpaid electricity programs, human errors often occur when officers read the kwh meter and PLN officials do not go down to residents' homes to record consumer usage due to the co-19 pandemic. In this research, an electrical energy monitoring tool was built using SMS (short massage service) based on the ATMEGA 2560 microcontroller that can measure and monitor the electrical energy consumption in real time using a voltage sensor and current sensor SCT013-030. The results of the current and voltage sensor readings will be forwarded to the ATMEGA 2560 microcontroller to be converted to the amount of electrical energy consumption and the amount of payment in accordance with the rates set by the PLN.