Claim Missing Document
Check
Articles

Found 15 Documents
Search
Journal : Foristek

SISTEM DETEKSI DINI BANJIR BERBASIS SENSOR FLOAT MAGNETIC LEVEL GAUGE -, Fahrul, Miranti, Ambo Asse; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 3, No 2 (2013)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (204.198 KB)

Abstract

Central Sulawesi has tropical climate conditions with interconnected rivers caused each of it can experience the impact of the sudden rise of water levels if there is a heavy rainfall in upstream areas which is commonly called “a sent flood”. Therefore, it is needed an early detector flood tool that works based on the height of river water level so that the impact of floods can be minimized. Early detector flood tool can function automatically by giving early warning when water levels reach a certain limit. The detector of height levels of river streams is designed using float magnetic level gauge method. This height level of river streams detector is able to provide information in real time based on the height level of river streams by giving information in the form of warning light indicator and siren alarm as alert and danger sign. Key words: detector, early, flood, float, magnetic.
EVALUASI SETTING DISTANCE RELAY PADA SUTT 150 KV ANTARA GI PAMONA – GI SIDERA Adrianto, J; Sarjan, Muhammad; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 6, No 1 (2016)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A short circuit is a common fault of overhead lines. In 2015, short circuit caused by surge lighting and fallen trees, occurred four times in transmission line connected PamonaSiderasubstation. In securing transmission line, distance relay should be applied as the primery protection. However, incorrect setting of relay may readily lead to relay failure to protect the line. Therefore, evaluation of relay setting is crucial. The purpose of this paper is to evaluate the setting of distance relay that was installed at Pamona and Sidera substation. Furthermore, calculation of curent fault and impedance of short circuit was done by intervering fault to the line connected Pamona and Sidera substation in matlab. The method used is simulation using matlab application. The result shows that the highest short circuit current obtained at 25% of the length of Pamona-Sidera transmission line, 6203.47A. The smallest short circuit current was 1255,86A, occurred at 100% of the Keyword : Short Circuit, Distance Relay, Transmission line
EVALUASI JARINGAN TEGANGAN MENENGAH SISTEM KELISTRIKAN KAMPUS UNIVERSITAS TADULAKO MENGGUNAKAN ETAP 7.5.0 Santiyasa, I Nyoman; Sarjan, Muhammad; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 4, No 2 (2014)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Electricity is a secondary energy form that is generated, transmitted and distributed for all kinds of purposes. Tadulako University Campus an electricity consumer with considerable power and continue their development rapidly. Because of the construction, the electrical load is also increasing, the medium-voltage network as one of the components of the power system needs to be evaluated in order to serve the load capacity continuously. Electrical power is supplied from distribution transformers to user have voltage loss and power losses. Because the distribution network has resistance, inductance, and capacitance. The energy lost already appeared from the generation system. This study was conducted by analyzing model of the single line diagram with input medium voltage-network Tadulako University campus data in ETAP 7.5.0 application. From the analysis, there were losses in the medium voltage network Tadulako University Campus at 1.358% with 0.39% voltage drop at the existing load. Keywords : Electricity, Losses, Drop Voltage, Medium Voltage Networks, ETAP
WATAK HARMONIK PADA INVERTER TIGA FASA TAK BERBEBAN Sunanda, Wahri; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 1, No 1 (2011)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1067.641 KB)

Abstract

AbstractHarmonic is one of sinusoidal components, one wave period from whichhaving multiple frequency of its fundamental frequency one, leading toelectrical power quality problems. Harmonic distortion in term of voltageand current ones, generally is due to non linier impedance. Inverter is one ofexample of it. There are some items that will be measured. There are value ofharmonic at source and value of voltage and current harmonic when inverter does not have any load. IEEE Standard of 5191992 as a reference in determining maximum limitation voltage and current harmonics. The result of the tests were showed that voltage harmonic distortion at inverter did not exceed the IEEE 5191992 maximum limitation of 5%. While current harmonic distortion had exceed the maximum limitation of the IEEE 5191992. The highest results were exceeding 56,55 % when inverter does not have any load.Keywords: Voltage, Current, Harmonic Distortion, Inverter.
PELUANG HEMAT ENERGI LISTRIK PADA GARDU FISIP KAMPUS UNIVERSITAS TADULAKO Siregar, Restu Ary Winata; E, Darmawan; Mukhlis, Baso; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 6, No 1 (2016)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The use of electrical energy in University is an absolute and unavoidable. Based on data obtained, every year Tadulako University experienced a high increase in electrical energy consumption. The electricity bills of Tadulako University based on data 8 months from January to August 2015 reached Rp.2.567.411.878 that is in average of payment per month of Tadulako University is Rp.322.051.485.At the substation of FISIP electricity usage in January through August 2015 was highest in June reaching 61.750 kWh to the cost of electricity bill as big as Rp.55.575.000. Electric energy audit begins with the historical data collection of electricity biil in the last three years such as : the substation of FISIP on January to August, the data load of electrical equipment, and the spacious rooms supplied. The intensity of energy consumption and the energy-saving opportunities were counted from each supplied rooms of substation FISIP. The result of the calculation of the intensity of energy consumption in detail can be seen throught 160 total rooms if the energy-saving opportunity of 49 rooms is implemented. Therefore, Tadulako University can save the cost of electricity by Rp.30.140.900,73 per month. Keywords : Electrical Energy Audit, Energy Consumption Intensity, Energy Saving Opportunities, Efficiency, Substation FISIP, Tadulako University
APLIKASI FILTER PASIF SEBAGAI PEREDUKSI HARMONIK PADA INVERTER TIGA FASE Sunanda, Wahri; Rahman, Yuli Asmi
FORISTEK : Forum Teknik Elektro dan Teknologi Informasi Vol 2, No 1 (2012)
Publisher : FORISTEK : Forum Teknik Elektro dan Teknologi Informasi

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (631.395 KB)

Abstract

Harmonic is one of sinusoidal components, one wave period from which having multiple frequency of its fundamental frequency one, leading to electrical power quality problems. Harmonic distortion in term of voltage and current ones, generally is due to non linier impedance. Inverter is one of example of it. There are some items that will be measured. There are value of harmonic at  source and value of voltage and current harmonic when inverter does not have any load. IEEE Standard of 519-1992 as a reference in determining maximum limitation voltage and current harmonics. The result of the tests were showed that voltage harmonic distortion at inverter did not exceed the IEEE 519-1992 maximum limitation of 5%. While current harmonic distortion had exceed the maximum limitation of the IEEE 519-1992. The highest results were exceeding 57,52 % when inverter does not have any load. After using passive filter that function for reducing the value of harmonic,  the total harmonic distortion (THD) current w only 6,837%  when inverter does not have any load.   Keywords : Voltage, Current, Harmonic Distortion, Passive Filter.
PEMILIHAN TIPE PEMBANGKIT LISTRIK TENAGA GELOMBANG LAUT TIPE PELAMPUNG DI PANTAI SALUBOMBA KABUPATEN DONGGALA Setiyawan Setiawan; Yuli Asmi Rahman; Muhammad Sarjan; Nurhani Amin
Foristek Vol. 11 No. 1 (2021): Foristek
Publisher : Foristek

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (801.88 KB) | DOI: 10.54757/fs.v11i1.37

Abstract

Indonesia is a country that has an area of sea three times larger than the land area. In line with the rapid development, the need for electricity is also increasing. So that Indonesia has great potential to produce alternative and environmentally friendly energy, namely Sea Wave Energy. Its continuous nature is available all the time. Many potential coastal areas in Indonesia, however, have not been utilized optimally. The purpose of this study is to see the potential of Wave Energy for electricity. For this reason, research was carried out at a location in the Central Sulawesi area, precisely in Salubomba, Central Banawa District, Donggala Regency. In this study a potential study was conducted on 3 types of PLTGL, namely Buoy, OWC, and Pasut Dam, where one will be chosen that meets the wave criteria requirements on the Beach. From the results of research, PLTGL that fulfills the requirements is the type of buoy. Data collection begins with secondary data, namely wind data from Mutiara Station. Then proceed with calculating wave forecasting using the SMB (Sverdrup Munk-Bretschneider) method. The results of this study, Salubomba beach has the potential to be built by the Buoy Type Wave Power Plant, a significant wave height of 0.52 - 3.37 meters with a ruptured depth of 3.95 meters.
WATAK HARMONIK PADA INVERTER TIGA FASA TAK BERBEBAN Wahri Sunanda; Yuli Asmi Rahman
Foristek Vol. 1 No. 1 (2011): Foristek
Publisher : Foristek

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Harmonic is one of sinusoidal components, one wave period from which having multiple frequency of its fundamental frequency one, leading to electrical power quality problems. Harmonic distortion in term of voltage and current ones, generally is due to non linier impedance. Inverter is one of example of it. There are some items that will be measured. There are value ofharmonic at source and value of voltage and current harmonic when inverter does not have any load. IEEE Standard of 519-1992 as a reference in determining maximum limitation voltage and current harmonics. The result of the tests wereshowed that voltage harmonic distortion at inverter did not exceed the IEEE 519-1992 maximum limitation of 5%. Whilecurrent harmonic distortion had exceed the maximum limitation of the IEEE 519-1992. The highest results were exceeding56,55 % when inverter does not have any load.
APLIKASI FILTER PASIF SEBAGAI PEREDUKSI HARMONIK PADA INVERTER TIGA FASE Wahri Sunanda; Yuli Asmi Rahman
Foristek Vol. 2 No. 1 (2012): Foristek
Publisher : Foristek

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Harmonic is one of sinusoidal components, one wave period from which having multiple frequency of its fundamental frequency one, leading to electrical power quality problems. Harmonic distortion in term of voltage and current ones, generally is due to non linier impedance. Inverter is one of example of it. There are some items that will be measured. There are value of harmonic at source and value of voltage and current harmonic when inverter does not have any load. IEEE Standard of 519-1992 as a reference in determining maximum limitation voltage and current harmonics. The result of the tests were showed that voltage harmonic distortion at inverter did not exceed the IEEE 519-1992 maximum limitation of 5%. While current harmonic distortion had exceed the maximum limitation of the IEEE 519-1992. The highest results were exceeding 57,52 % when inverter does not have any load. After using passive filter that function for reducing the value of harmonic, the total harmonic distortion (THD) current w only 6,837% when inverter does not have any load.
PERPINDAHAN PANAS HYBRID PHOTOVOLTAIC DAN THERMOELEKTRIC GENERATOR DENGAN HOT MIRROR Ardiansyah Ardiansyah; Mustofa Mustofa; Iskandar Iskandar; Andi Idhan; Yuli Asmi Rahman
Foristek Vol. 11 No. 2 (2021): Foristek
Publisher : Foristek

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54757/fs.v11i2.111

Abstract

Heat transfer is the transfer of energy from one area to another due to the temperature difference between these areas. Wasted heat energy can be converted into electricity using (TEG) between the hot and cold sides. If the temperature difference is more significant, the efficiency may increase along with the operating temperature of the TEG-type material. So in this study, the author will calculate the heat transfer that occurs in Photovoltaic (PV), Thermoelectric Generator (TEG), and Hot Mirrors by utilizing thermal energy light produced from Muxindo LED bulbs with 10 Watt, 15 Watt, and 20 Watt power. The results of this study indicate that by using 10, 15, and 20 Watt LED bulbs for free convection heat transfer, the power generated from each point increases because it passes through several obstacles from objects that experience a decrease in temperature to PV and TEG, with the characteristics of the displacement. The movement of molecules from the medium importance follows convection heat at every point of transfer in the intermediate substance. The most significant power generated from radiant heat transfer is about 0.1873 Watt. It occurs on the surface of the fresnel lens using a 20 Watt LED bulb with the characteristic that the radiation propagates in a straight line and does not require an intermediate medium to transfer heat from one substance to another. The most significant conduction heat transfer power, 0.2453 Watt, occurs in Fresnel Lens using a 20 Watt LED bulb with heat transfer characteristics in solid objects.
Co-Authors Adrianto, J Agus Siswanto Agustinus Kali Al-Habsyi, Faisal Amaliah, Asma Amar Amar Ambo Asse Ambo Asse Miranti Fahrul - Aminuyati Andi Arham Adam Andi Chaerul Achsan, Andi Chaerul Andi Idhan Andi Rusdin Anjar Asmara Ardi Nugraha ARDI NUGRAHA, ARDI Ardiansyah Ardiansyah Ardias, Erwin Arham, Andi Ashad, Bayu Adrian Baso Mukhlis Basri Basri Basri Basri Dadang Kurnia Dadang Kurnia, Dadang Daud Patabang Deny Wiria Nugraha Diana Diana E, Darmawan Erwin Ardias Saputra Fahrul Fahrul Hanni Maksum Ardi Hariyanto Hariyanto I Wayan Sutapa Indrajaya, Muhammad Aristo Irwan Mahmudi Irwan Mahmudi Iskandar Iskandar Iskandar Iskandar JAKARIYA - - Jakariya, Jakariya Khairil Anwar Khairil Anwar Khairil Anwar Lukman, Musfirah Putri M Rusdi Maharani, Dhyvia Mahmudi, Irwan Mardjudo, Ahsan Maryantho Masarrang Medi, Gery Mery Subito Miranty Miranty Mucharomah, Nurul Maghfiroh Muchsin Muchsin Muhammad Din Muhammad Sarjan Muhammad Sarjan Muhira Dzar Faraby, Muhira Dzar Mustika Mustika Mustofa Mustofa Mustofa Mustofa Nasution, Annio Indah Lestari Nurhani Amin PAMUSO, MARLIN Putra, Wisnu Rahmat Dwi Rachmawati, Sitti Ramadani, Angger Ratih Mar'atus Sholihah Ratih Mar’atus Shalihah Rizana Fauzi, Rizana Rizkhi Rizkhi Rustan Hatib Samnur . Santiyasa, I Nyoman setiawan, Dibyo Setiyawan Setiawan Sirad, Mochammad Apriyadi Hadi Siregar, Restu Ary Winata Sitti Nuradha Wati S sofyan sofyan Sonita, Anisya Sundun Sada Maripi Tan Suryani Sollu Thaha, Sarma Vauzia, Farrah Wahri Sunanda Wahyu H. Piarah Yulius Salu Pirade Yusnaini Arifin Zuryati Djafar