Pengaruh Modifikasi Pipa Pendingin Terhadap Efektivitas Induced Draft Cooling Tower LBC-50 Naufal, Muhammad Fairuz; abdulah, amri; Heryadi, Yadi; Shieddieque, Apang Djafar; Rajab, Dede Ardi; Suhartini, Sri
Jurnal Teknologika Vol 15 No 2 (2025): Jurnal Teknologika
Publisher : Sekolah Tinggi Teknologi Wastukancana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51132/teknologika.v15i2.540

Abstract

This study aims to analyze the performance enhancement of an induced draft cooling tower through modifications to the water distribution piping line, as well as to evaluate the thermal and hydraulic performance before and after modification. The initial system exhibited relatively low cooling effectiveness due to uneven water distribution and limited heat transfer between air and water within the tower. Therefore, the piping layout was redesigned to improve flow uniformity, enlarge the air–water contact area, and minimize heat losses, thereby enhancing overall cooling efficiency. The experimental tests were conducted under identical operating conditions with an inlet water temperature of 38 °C. The results showed that the outlet water temperature decreased from 33.78 °C (before modification) to 28.95 °C (after modification). The range increased from 5.17 °C to 9.12 °C, while the approach decreased from 4.68 °C to 2.61 °C, indicating a more effective cooling process approaching ideal conditions. Furthermore, the cooling capacity showed a substantial increase from 21,717.4 kW to 61,515.1 kW, signifying that the modified cooling tower can dissipate a greater amount of heat and support higher cooling demands in industrial operations. In addition, the system effectiveness improved from 52.45% to 77.58%, demonstrating a significant enhancement in heat transfer efficiency as a result of improved fluid distribution. On the other hand, the total head loss increased from 39.11 m to 63.71 m, indicating higher flow resistance due to the new configuration, but it remained within acceptable limits. Overall, the study concludes that modifying the piping line in the induced draft cooling tower significantly improves thermal performance, cooling effectiveness, and capacity, making the redesigned configuration a viable approach to increase the efficiency of large-scale industrial cooling systems..
Co-Authors Abdul Wahid Agus Pratama, Andhika Putra Aimar, Ilhan Maulana Alfisya, Lailia Amna , Amna Amna Hartiati Amri Abdulah Arif Setyawan, Sang Aji Asmaul Mustaniroh, Siti Bambang Admadi Harsojuwono Dodyk Pranowo Effendi, Masud Elviliana, Elviliana Ely Ratnawati Endah Rahayu Lestari Falasifah, Ratu Firdiani Nur Afifah, Firdiani Nur Hamzah, Muhammad Hazwan bin Harahap, Nur Anisah Rizky Hari Sulistiyo Harianja, Berkat Harsujuwono, Bambang Admadi Hasibullah, Muhammad Umar Helena, Denni Fransiska Helfiardi, Ray Dida Heryadi, Yadi I Gusti Ayu Lani Triani Idrus, Syazwani Ika Atsari Dewi Irnia Nurika Iswandari , Novita Dewi Jung, Young Hoon Kurniawati, Darini Lee, Yeon Ju Loeki Enggar Fitri Lutfi Suhendra Mabel Rahma, Tarissa Almira Maimunah Hindun Pulungan Md Rezali, Khairil Anas Melville, Lynsey Nafi'ah, Riris Waladatun Nafi’ah, Riris Waladatun Namira, Anggi Alya Naufal, Muhammad Fairuz Nimas Mayang Sabrina Sunyoto, Nimas Mayang Sabrina Nur Hidayat NURUL AZIZAH NYOMAN SEMADI ANTARA Panji Deoranto Permatasari, Vitta Rizky Pratama, Andhika Putra Agus Rahma, Novita Ainur Rajab, Dede Ardi Ramadan, Awal Rohma, Novita Ainur Rohma, Rohma Sabrina Sunyoto, Nimas Mayang Sakunda Anggarini, Sakunda Salsabila, Hanna Syakira Samudra, Rizki Putra Saragih, Ruth Natasya Octaviani Sarinengsih, Yuyun Sarinengsih, Yuyun Setyawan, Hendrix Yulis Shieddieque, Apang Djafar Sri Kumalaningsih Subekti, Indah Fitriana Sukardi Sukardi Susinggih Wijana Ts, Novitasari Usman Effendi Vindhya Tri Widayanti, Vindhya Tri Widya Dwi Rukmi Putri Widya FATRIASARI Wilujeng, Rohmi Nadi Yeyen Nurhamiyah, Yeyen Yusuf Wibisono