Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Jurnal Nasional Teknik Elektro dan Teknologi Informasi

Pengaruh Penutupan-Balik Tak-Sinkron terhadap Generator Induksi 3-Fase dalam Skema Pembangkitan Tersebar M. Isnaeni B. S.; F. Danang Wijaya; Eka Firmansyah
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 6 No 4: November 2017
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1258.822 KB)

Abstract

Small and medium-scale plants connected to the distribution line form a distributed generation (DG) system. Unsynchronized reclosing, due to the operation of a recloser, is an important issue in DG systems. In this paper, simulations of typical DG system are performed to show the effect of unsynchronized reclosing. The simulation results show that unsynchronized reclosing causes the generator to experience over speed, over and under voltage, and over current, which can damage or reduce the life of the generator. A permanent short circuit that causes the contact of recloser to open and close repeatedly has a worse effect than a temporary short circuit. Opening the circuit breaker at point of common coupling with the installation of dummy load can reduce the bad effect of unsynchronized reclosing.
Sinusoidal Pulse Width Modulation Berbasis Lookup Table untuk Inverter Satu Fase Menggunakan 16-Bit Digital Signal Controller Yohan Fajar Sidik; Danang Wijaya; Eka Firmansyah
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 2 No 2: Mei 2013
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1208.499 KB)

Abstract

Inverter as one equipment relates closely to the renewable energy sector gain more and more important role in utilizing renewable energy widely. The inverter converts dc to ac form by a specific switching strategy. In this research, the switching strategy employed unipolar sinusoidal pulse width modulation (SPWM). The switching schemes were obtained by synthesis from sine lookup table that the width of pulses were obtained from simulation of PSIM. The aim of this research is to create a switching scheme in a software and then implemented in16-bit digital signal controller (DSC). Experiment in lab scale has been done to verify the proposed unipolar SPWM. The results showed that SPWM signals were easier generated in 16-bit digital signal controller (DSC). Other that, feature of PWM in this DSC has been supporting in inserting dead-time to avoid shoot through current at IGBT.
Implementasi Komunikasi Data Berbasis ZigBee pada SCADA (Supervisory Control and Data Acquisition) PLTMh Beny Firman; Suharyanto; Eka Firmansyah
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 2 No 1: Februari 2013
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (742.631 KB)

Abstract

Recently, Microhydro Power Center (Pusat Listrik Tenaga Mikrohidro or PLTMh) has been spread widely the energy electric generator. PLTMh control system in Indonesia often uses automatic control system. One of the reasons for this is that the operation and monitoring of the PLTMh could be done from a distance. One of PLTMh models of remote control is known as SCADA. One of the main parts of SCADA is Master Station (MS), Remote Terminal Unit (RTU) & Communication System. Communication System in SCADA can be built in several choices: wired or wireless. Remote control can be built using Wireless Sensor Network (WSN) system. The application of WSN in operating SCADA could ease installation and increase communication reliability. This study applied ZigBee technology on PLTMh SCADA control data communication. ZigBee was chosen because it’s free of operation and licensing charge, had OSI feature and low cost, those are reasons why they are best suited to PLTMh application. In the application, ZigBee hardware was divided into several parts: Coordinator on Master Station(MS) (one unit), End Devices which were each RTU unit point (two units) and Router as a data hooping between Coordinator & End Device (one unit). The furthest point between Coordinator and End Device through Router could reach 645 meters. This was tested in LOS (Line of Sight) condition. RSSI signal on ZigBee was used to see the strength of signal reception on Coordinator as data collector. RSSI score (-dBm) became smaller at maximum distance variation. This meant signal power at data jump point became lower. ZigBee based data communication to form SCADA network had been built well in join a network model, which was between Coordinator — Router — End Device at the furthest distance, 645 meters, with signal power of -82dBm.
Aplikasi Magnetic Energy Recovery Switch sebagai Dynamic Voltage Restorer pada motor Induksi Dwi Dharma Artakusuma; Fransisco Danang Wijaya; Eka Firmansyah
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 7 No 2: Mei 2018
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1559.715 KB)

Abstract

Renewable energy source likes solar panel and wind turbine have intermittent character from instability power source generated. The instability power source can make dip voltage in power grid which happen in half cycle until few seconds. To stabilize the voltage in power grid from dip voltage, some methods have been developed using power electronics technology like VSI inverter, STATCOM, energy storage, OLTC, and MERS. The power electronic circuits have some advantages, such as small dimensional size and lightweight to keep voltage in power grid. In this paper, the MERS circuit was applied in induction motor which has small full bridge circuit, uncomplexity computation, and low switching frequency, so it needs low end hardware requirement. This paper proposed the use of MERS dc capacitor with 50% value from induction motor resistance. The result shows that MERS has advantage and can keep the voltage in power grid when the voltage below 39% and 15% above rated voltage (220 Vrms) with the recovery time around 0.3 second and keep the dip voltage over 1 second.
Pengendalian Motor DC Tanpa Sikat Sederhana dengan DSC 16-bit pada Aplikasi EDF Fikra Titan Syifa; Eka Firmansyah; Priyatmadi
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 4 No 4: November 2015
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (303.234 KB)

Abstract

Basically, commutation process in a brushless DC motor needs rotor position information. However, to reduce production cost, in some specific applications such as fan or pump, the position sensors are not installed. It is possible to extract the rotor position through observing back emf signal available on the motor terminals. In this paper, implementation of a simple sensorless commutation controller algorithm for a BLDC motor is presented. The algorithm is implemented in a 16-bit digital signal processor (DSC). Experiment has shown that it produces correct timing signal to control BLDC motor from 1280 rpm up to over 3000 rpm.
Co-Authors -, Priyatmadi Addin Suwastono, Addin Adeguna Ridlo Pramurti Adha Imam Cahyadi Agung Prasetyo Agus Sujono Anang Budhi Nugroho Arief Wisnu Wardana Artakusuma, Dwi Dharma Beny Firman beny firman, beny Budi Nugroho CAHYADEWA, FELIX AUSTIN Deddy Susilo Dwi Dharma Artakusuma Dwiarifiyanti, Septian Dwiyana, A. Sy. Dina Fasa, Iraldy Laendra Fauzan, Naufal Hilmi Fikra Titan Syifa Fransisco Danang Wijaya Hanny Hafiar Hardiansyah Hardiansyah Harnoko St., Harnoko Hasnahwati Ibnu Hasan, Ibnu Inaya Retno Putri Indah Soesanti Indra Perdana Indrawan, Rully Iswanto Iswanto Johan Agung Irawan Kania, Enung Sri Khozin, Khozin L. Heru Pratomo Leonardus Heru Pratomo Lesnanto Multa Putranto Lia Saniah Lilik Sutiarso Litasari Litasari Maemonah, Maemonah Masdul, Muhammad Rizal Maulidia, Khoirina Dwi Ayu Meika, Ika Moh Nur Hakim Mohammad Yanuar Hariyawan Mokhammad Isnaeni Bambang Setyonegoro Mubarika, Melinda Putri Nasihin, Darojatun Nenden Mutiara Sari Nia Maharani Raharja Noor Pratama Apriyanto Noviarianto, Noviarianto Oyas Wahyunggoro Pebriyani, Nais Prapto Nugroho Pratama, Dimas Yanuar Pratomo, Saifurrahman Iman Priyatmadi Pujiastuti, Sulastri Putri, Inaya Retno R. Poppy Yaniawati R. Soekrisno Rachmalia, Nela Rahayu Kariadinata Rakhmat, Rizki Safari Ramadina, Ina RANI RANI, RANI Risanuri Hidayat Riz Rifai O. Sasue Romelah Romelah Rudy Hartanto S.Pd. M Kes I Ketut Sudiana . Sahrudin, Asep Saiful Anwar Septian, Cepi Sidik, Yohan Fajar Sihono, Soekrisno, R. Solihah, Siti Suharyanto Suharyanto Suharyanto Suharyanto Suharyanto Suharyanto SUHARYANTO SUHARYANTO Sujono, Agus suminar, Chandra Siti Supianti, In In Suputa Suputa Syamsuddin, Sri Devi T. Haryono T. Haryono Tarcisius Haryono Tedy Juliandhy Tiyono Tobroni Tobroni Toni Prasetya Trigas Badmianto Tumiran Wahidin, Didin Wahyu Dewanto Wahyudin, Yudin Wardana, Arief Wisnu Wicaksono, Ridwan Widyawan Wijaya, Danang Wijaya, Nur Hudha Wijaya, Nur Hudha Wulansari, Tantya Y Munandar Kolewora Y. Andi Trisyono Y. Munandar K. Yaniawati, Poppy Yhone Arialistya Yogi Sawitra Yulianie, Lia Yuwono Bimo Purnomo