Improving the Effectiveness of Automatic Pure Tone Audiometer with Audiogram and Patient Diagnosis Aulia Rahmawati; I Dewa Gede Hari Wisana; Endang Dian Setioningsih; Sari Luthfiyah; Bedjo Utomo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 3 (2020): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i3.2

Abstract

Conventional Audiometer testing using manual mode takes quite a long time for one patient, and the audiologist must accompany until the test is complete. The purpose of this research is to design a pure tone audiometer with an automatic mode using Arduino microcontrollers. Contributions from this research is a system of automatic running to improve health services. The Hughson Westlake method is used for automatic mode. The method is prepared in the Arduino software and uses the CD4066 digital switch to regulate the frequency and intensity given to the patient. As for the frequency generator using XR2206, the raised frequencies are 250, 500, 1000, 2000, 4000, 8000 Hz. Then the patient will press the interrupt button if listening to sound, and the result will be displayed to the Audiogram on Android. Patient diagnostic results can be seen when testing the entire frequency has been completed. At frequency 250 Hz obtained error value 0.13, at frequency 500 Hz obtained error value 4.37, at frequency 1000 Hz obtained error value 39.5, at the frequency of 2000 Hz obtained error value 24.67, at the frequency of 4000 Hz obtained error value 67.33. And at the frequency of 8000 Hz obtained error value 32.33. The results of this study showed that the highest error was 3.95% at 1000Hz frequency and the smallest error was 0.05% at 250Hz frequency. The results of this study can be implemented in conventional audiometer system to accelerate testing time to improve service and facilitate audiologist during hearing testing.
Utilization of Power Setting in Mono-polar Electrosurgery Unit With Additional Blend Modes Muhammad Roni Setiawan; Tri Bowo Indrato; Triana Rahmawati; Bedjo Utomo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.7

Abstract

Electrosurgery unit has the purpose of damaging certain body tissues by heating the tissue. In this study there are several modes and also power selection. The contribution of this research is to design the power management and also the addition of several modes for the surgical process. Electrosurgery Unit involves the use of IC CMOS 4069 as a frequency generator. The frequency output is set at 250 KHz and then passed on to the pulse regulator circuit and controlled by using Arduino and then forwarded to the inverter circuit which functions to increase the voltage and output in the form of power. Modules are calibrated using ESU Analyzer. This module is equipped with a selection of LOW, MEDIUM, and HIGH power. And also there are some additional modes including Blend 1 and Blend 2. After the measurement is carried out, the voltage values ​​obtained at the setting of low, medium high, on the inverter input with a value on Blend 1 mode low 80 V with an error of 0.84%, Medium 90 V with error 0.84%, High 104 V with an error of 0.81%, in Blend 2 mode low 84 V with an error of 0.83%, Medium 86 V with a error of 0.85%, High 105 V with an error of 0.81%, the Cutting mode is low 162 V with an error of 2.88%, medium 172 V with an error of 3.03%, High 192 V with an error of 2.86%. The measurement shows an error of less than 1% for Blend 1 and Blend 2 modes while cutting is less than 3%. The results of this study can be implemented in order to minimize errors due to lack of power settings and mode selection during surgery.
Development of Measuring Device for Non-Invasive Blood Sugar Levels Using Photodiode Sensor Frendi Agung Dwi Saputra; Bedjo Utomo; Sumber Sumber
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.3

Abstract

Diabetes mellitus is one of the deadliest diseases faced by Indonesian people. The number of sufferers of this disease in Indonesia is 10 million according to the International Diabetes Federation (IDF). Indonesia is included in five countries with the number of people with diabetes mellitus. This disease is caused by high levels of glucose in the blood. Patients are usually not controlled for sugar consumption in everyday life. For measuring blood sugar levels so far, the most widely used device is invasive, namely by injuring the patient's body. Techniques like this make people reluctant to take measurements of glucose levels in their blood routinely. Though it is recommended to take measurements regularly to be able to control the intake of nutrients in the body. The method used in this experiment is to design and build a blood sugar measuring device using a photodiode sensor. As well as collecting data on several patients related to blood to obtain patient data. Based on the results of the identification of the problems mentioned above, the authors make a non-invasive measuring tool entitled "Design of a Non-invasive Blood Sugar Measuring Instrument (TFT Display)". Results that have been obtained from this study are there are error values in the voltage measurement circuit voltage distribution with the calculation of the resistance value to get the voltage value. The error value obtained is 5%. The results of the linear regression value of 0.996.
Low Cost Health Monitoring Sytem Based on Internet Of Things Using Email Notification I Dewa Gede Hari Wisana; Bedjo Utomo; Farid Amrinsani; Era Purwanto
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.2

Abstract

Monitoring activities are needed if there are symptoms of a disease that require quick action so that the patient's condition does not get worse, for that we need a system that can notify doctors so they can take action. The patient monitoring system in hospitals is generally still carried out conventionally, among others, nurses or doctors come to the patient's room to check on the progress of the patient's condition, this will be a problem, if the number of medical personnel and facilities is insufficient to monitor. Patients who need special attention for patient care, such as monitoring the patient's breathing rate. The use of the internet of things (IOT), as a device that can work without the help of people, can perform tasks and provide easier and real time data, so that they can access output directly. The purpose of this research is to design an inexpensive health monitoring tool based on the Internet of Things (Respiration Parameters) using a piezoelectric sensor and an ESP32 Wi-Fi module. From the results of the module design taken from 10 respondents, obtained that the average measurement high accuracy (17.76 + 0.61) and the average level of stability of the design has a magnitude of 0.4 so that it can be concluded that using a piezoelectric sensor in this series can obtain good accuracy. This the design can be used to monitor a person's respiration in real-time
Design a Low-Cost Digital Pressure Meter Equipped with Temperature and Humidity Parameters Bedjo Utomo; I Dewa Gede Hariwisana; Shubhrojit Misra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i2.4

Abstract

Calibration is a technical activity which consists of determining one or more properties and characteristics of a product, process or service according to a predetermined special procedure. The purpose of calibration is to ensure measurement results comply with national and international standards. The purpose of this study is to design two mode digital pressure meter (DPM) device equipped with a thermo-hygrometer and pressure in which the design is completed with a selection mode to determine the positive and negative pressure (vacuum) using MPX 5050GP sensor as a positive pressure sensor. In this design DHT 22 sensors is used to measure the humidity and temperature. To test the leak test this device is also equipped with timer. This design uses a 2.4 inch Nextion TFT LCD screen to display data. Data analysis was performed by comparing modul with standard tools. In the measurement process, Mercury tensimeter was carried out 6 times the data and the smallest results were 0 mmHg on the module and 0 mmHg on the standard tool and the largest was 298.0 mmHg on the module and 300 mmHg on the standard tool. Data were collected in a room with a temperature of 31̊C and humidity of 87%. Finally, this design is applicable for daily used for electromedical engineer to calibrate the sphygmomanometer in the hospitals
EFEKTIFITAS PENGGUNAAN SINAR UV UNTUK PENYIMPANAN PERALATAN MEDIS PUSKESMAS Bedjo Utomo; Endang Dian Setioningsih
JURNAL PENELITIAN KESEHATAN Vol 12, No 2 (2014): Jurnal Penelitian Kesehatan
Publisher : Poltekkes Kemenkes Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (425.59 KB)

Abstract

In general, this study analyzed the effectiveness of the use of UV light for the storage of medicalquipment in health centers by distance and time. This type of this research is experimental withre and post study design, particularly to analyze the effectiveness of UV light by distance and timef exposure. As the dependent variable in this study is the microorganisms and the independentariables are the factors of distance, time and design of medical devices storage size, while theontrol variable is the gelatin media. The results of UV light exposure at a distance 20 cm arebtained intensity of 15.8 Lumen and at a distance of 15 cm are obtained intensity of 11.2 Lumen.The average temperature that obtained during 3-hours exposure was at 35°C. Time effectivenessthat used to inhibit the growth of bacteria in the intensity of 15.8 lumen is 4 hours, while theintensity of 11.2 Lumen is 5-8 hours. Effectiveness analysis of the rate of growth of bacteria atintensity of 15.8 lumen using test probability 0.5% was obtained a significant value = 0.007 whereacterial samples of air quality (x2) is more effective than the kind of TBC bacteria (x). Theintensity at distance of 20 cm and 15 cm by using the Mann Whitney test it is obtained statisticalues  = 0.513 0.05 where there is no statistical difference between these two intensity withthe rate of growth of bacterial colonies.In general, the results of this study can be concluded thatUV exposure can be used as a sterilizer on the storage of medical equipment in health centers thatimple by taking into account the factors of UV light time and intensity. Keywords:Effectiveness, UV light, sterilization, storage equipment, medical equipment 1
ECG Simulator Based on Microcontroller Equipped with Arrhythmia Signal M. Ridha Mak'ruf; Andjar Pudji; Bedjo Utomo; I Dewa Gede Hari Wisana; Torib Hamzah; Lamidi Lamidi; Denis Kurniar Wicaksono; Sedigheh Ashgari Baighout
Jurnal Teknokes Vol 15 No 2 (2022): June
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v15i2.244

Abstract

Electrocardiograph (ECG) is one of the diagnostic sciences that is often studied in modern medicine, used to detect damage to the components of the heart or disorders of the heart rhythm called arrhythmias. The purpose of this research is to develop an Electrocardiograph simulator that is equipped with arrhythmia. The main design consists of an Arduino Mega 2560 microcontroller, MCP4921 DAC (Digital to Analog Converter) circuit, a network resistor, and a sensitivity selection circuit. The MCP4921 type DAC converts the digital signal data into analog data which will then be forwarded to the resistor network circuit as a signal formation for each lead. The basic signal image data used for the formation of normal Electrocardiograph and arrhythmias were taken from the Electrocardiograph recorder using Phantom Electrocardiograph. Based on the readings on the Beat Per Minute setting of the module to the Beat Per Minute printout on the Electrocardiograph recorder, the error rate value for the Normal Sine Rhythm parameter is 0.790% for Beat Per Minute 30, 0.383% for Beat Per Minute 60, 0.535% for Beat Per Minute 120, 0.515% for Beat Per Minute 180 and 0.593% for Beat Per Minute 240. The error rate for the Arrhythmia parameter is 2.076% for ventricular tachycardia Beat Per Minute 160 and 0.494% for Supraventricular Tachycardia Beat Per Minute 200. The design of the Electrocardiograph simulator can simulate the signals of the human body and it can be used as a medium in the learning process in the world of health
Analysis of Tube Leakage of X-Ray Radiation Using Geiger Muller Sensor Equipped with Data Storage Bedjo Utomo; Tribowo Indrato; Her Gumiwang Ariswati; Urip Mudjiono; Bayu Ardiansyah; A K M Bellal Hossain; Klarnarong Wongpituk
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.5

Abstract

X-ray radiation (ionization) cannot be felt directly by the five human senses. Therefore, radiation monitoring is needed, one of which by using a survey meter. The purpose of this research is to directly monitor the level of radiation exposure and leakage of X-ray tube containers in the work area. This was done to ensure the safety and health of workers in the radiation transmission area, so that it is in accordance with the ALARA (As Low As Reasonably Achievable) principle, which is stipulated in the Decree of the Minister of Health RI No. 1250/Menkes/SK/XII/2009 concerning Guidelines for Quality Control of Radiodiagnostic Equipment as Standard Values ​​for X-Ray Radiation Monitoring. This research is an experimental study with a survey meter equipment module design using a Geiger Muller sensor equipped with data storage. This module design method uses Arduino programming as data processing and is displayed on the CHARACTER LCD. Test analysis was carried out by comparing the measurement value of the module with the standard value as a standard for comparison. Based on the measurement results, the X-ray tube leak test value resulted in a standard AAT survey meter value of 0.001 both using a closed and unsupplied 2mm Pb circuit, namely 0.00097 mGy/hour and 0.00092 mGy/hour. Meanwhile, the results of the tube leakage test using a survey meter, both circuits, modules, and standard survey meters show a passing grade test value of < 1mGy/hour. In conclusion, the module design using the Geiger Muller sensor is feasible to use.
Lost Data and Transmition Speed Analysis on Incubator Analyzer Based IoT Technology I Kade Nova Paramartha; Torib Hamzah; Bedjo Utomo; Sari Luthfiyah; Emre ÖZDEMĐRCĐ
International Journal of Advanced Health Science and Technology Vol. 2 No. 1 (2022): February
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (848.982 KB) | DOI: 10.35882/ijahst.v2i1.7

Abstract

The importance of the readiness of the baby incubator for critical infant patients who are treated intensively encourages health technicians to carry out regular maintenance and calibration to overcome the problem of equipment malfunctions. Critical infant patients are babies who are treated in the NICU (Neonatal Intensive Care Unit) due to premature birth or babies using incubators are diagnosed with abnormalities or diseases, this situation makes babies need tools for survival, especially in the first month. Calibrating temperature control is very necessary for the incubator. In addition to temperature, it is necessary to control humidity so that the baby's respiratory system is in optimal condition. In addition, it is also equipped with a noise sensor to ensure that the noise in the baby incubator room is appropriate. From the above problems, a tool for temperature testing was made using a DHT22 sensor with five measurement points, humidity with a level of 30% RH - 60% RH and noise with a range of 30dB-60db to ensure the tool functions properly equipped with a lost data testing system and delivery speed. using internet access with thingspeak display. This research resulted in the design of a calibration tool with three parameters, namely the temperature setting at 33ºC the smallest error percentage is 0% and the largest error is 0.96%, and at the temperature setting 35ºC the smallest error percentage is 0.28% and the largest error is 4 .1%, humidity with an error percentage of 0.82% and noise with an error percentage of 0.93%. The drawback in using the Thingspeak application is that there is a limit on the channel ID, which can only display 8 readings, while the minimum time lag is 20 seconds. For the MAX4466 noise sensor, there are shortcomings, namely the accuracy in readings is not good.
Enhancing the Electrocardiogram Signal Quality by Applying Butterworth Infinite Impulse Response Filter 8th Order Nindia Rena Saputri; Sari Luthfiyah; Dyah Titisari; Bedjo Utomo; Lusiana Lusiana; Triwiyanto Triwiyanto; Faheem Ahmad Reegu; Wahyu Caesarendra
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i4.259

Abstract

The electrocardiogram (ECG) of the human body is an important basis in heart function as well as the diagnosis of cardiovascular diseases, which has a very vital role in clinical diagnosis. Obtaining high-quality ECG signals with a portable remote ECG acquisition system is a big challenge given limited resources. According to the World Health Organization (WHO), disorders of the cardiovascular system still rank high, causing about 31% of deaths globally. This is because the symptoms of cardiovascular disease cannot be seen directly, but rather by conducting an electrocardiograph (ECG) examination. The purpose of this research is to develop and analysis the ECG signal by comparing the 2nd order AD8232 module analogue filter with the 8th order Butterworth digital filter by applying infinite impulse response. This research uses a multiplexer circuit for switching leads, AD8232 ECG module, 50Hz notch filter circuit, non-inverting amplifier, adder, Arduino Mega 2560, USB module, and an application to display digital signals, namely Delphi 7. Signal acquisition is done by monitoring for one minute. Data collection was carried out with 5 respondents 5 times on each lead. The results of the data collection can be concluded that 80% of digital filters display smoother signals for ECG signals than analogue filters.
Co-Authors ., Sumber A K M Bellal Hossain A. Senthil Kumar Abdul Basit Abdul Kholiq Agistya Ananda Charisa Amrinsani, Farid Anant Athavale, Vijay Ananta, Erick Dwi Andjar Pudji Andjar Pudji Anggara Trisna Nugraha Ani Intiyati Anita Miftahul Maghfiroh Ardiansyah, Bayu Ariswati, Her Gumiwang Arum Triwerdani Asadina, Habliya Asalim T.P, M.Prastawa Assalim Tetra Putra, Moch. Prastawa Aulia Rahmawati Barends, Georgia Kusmiran Bayu Ardiansyah Candra Prastyadi Denis Kurniar Wicaksono Dita Musvika, Syevana Dwi K, Rizky Dwi S, Frendi Agung Dyah Titisari Dyah Titisari Dyah Titisari Dyah Titisari Dyah Titisari, Dyah Emre ÖZDEMĐRCĐ Endang Dian Setioningsih Endang Dian Setioningsih Era Purwanto Faheem Ahmad Reegu Farid Amrinsani Febrianti, Fani Forra Wakidi, Levana Frendi Agung Dwi Saputra Gadang Hendra Prabowo Gumiwang, Her Habliya Asadina Hamid, Imran Hamzah, Torib Hari Wisana, I Gede Dewa Her Gumiwang Ariswati Her Gumiwang Ariswati Her Gumiwang Ariswati Heru Sulistijono Hindaryani, Nurul Hossain, A K M Bellal I Dewa Gede Budi Whinangun I Dewa Gede Hari Wisana I Dewa Gede Hari Wisana I Kade Nova Paramartha Indrato, Tri Bowo Indrato, Tribowo Irvandi Isfahani, Ghina julianto, jusuf Klarnarong Wongpituk Kusumaningtyas, Yasmine Winda Lamidi , Lamidi Lamidi, Lamidi Liliek Soetjiatie Lusiana Lusiana Lusiana Luthfiyah, Sari Luthfiyah, Sari M. Prastawa Assalim T.P M. Ridha Mak'ruf M. Ridha Makruf Misra, Shubhrojit Mochammad Sofyan Mohammad Rofi'i Muhammad Ridha Mak'ruf Muhammad Roni Setiawan Nindia Rena Saputri Parameswaran Parameswaran Pudji, Andjar Ragimova, Nazila Rathod, Yagnik Rofi’i, Mohammad Rosari, Angela Erti Suci Rusdi Pratiwo Hadi Sari lutfiyah Sari Luthfiyah Sari Luthfiyah Sari Luthfiyah Sedigheh Ashgari Baighout Setiawan, Muhammad Roni Setioningsih, Endang Dian Setioningsih, Endang Dian Shubhrojit Misra Sofyan, Mochammad Sugeng Iwan Setyobudi Sumber Sumber Sumber, Sumber Suprihatin, Kusmini Syaifuddin Syaifuddin Syaifudin Syaifudin Syaifudin, Syaifudin Torib Hamzah Torib Hamzah Torib Hamzah Torib Hamzah Tri Bowo Indrato Tri Bowo Indrato Triana Rahmawati Triana Rahmawati Tribowo Indrato Triwiyanto Triwiyanto Urip Mudjiono Urip Mudjiono, Urip Wahyu Caesarendra Wahyu Caesarendra Wongpituk, Klarnarong Yasmine Winda Kusumaningtyas