Measuring Respiration Rate Based on Android Shofiyah, Shofiyah; Wisana, I Dewa Gede Hari; Triwiyanto, Triwiyanto; Luthfiyah, Sari
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 1 No. 1 (2019): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v1i1.237

Abstract

Abstract-Respiratory rate is the total number of breath or breathing cycle, which occurs every minute. Abnormal respiratory rate is a sensitive indicator for danger patients requiring medical treatment immediately. The objective of the study is to design a respiration rate monitor via an Android mobile phone. In this study, we used flex sensors to detect the respiration rate. The flex sensors were placed in the human stomach diaphragm which detects the changes in the human stomach diaphragm during breathing. The measurement results are displayed on the liquid crystal display (LCD) 2 x 16. The data will be sent via a Bluetooth connection to the android to display the values and graphs. The comparison between the design and standard showed that the maximum error is 4.69% while the minimum error is 1.52%. The average error for all measurement is 2.83%. It can be concluded that the tool wear is eligible because it is still below the minimum threshold of 10% error
Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters Zahra, Isna Fatimatuz; Wisana, I Dewa Gede Hari; Nugraha, Priyambada Cahya; Hassaballah, Hayder J.
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 3 No. 3 (2021): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.244

Abstract

Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition
QRS Complex Detection on Heart Rate Variability Reading Using Discrete Wavelet Transform Arga Wihantara; I Dewa Gede Hari Wisana; Andjar Pudji; Sari Luthfiyah; Vijay Anant Athavale
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 4 (2022): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.159

Abstract

Heart Rate Variability or heart rate in humans is used to monitor the function of the human heart. This research designed a tool to compare the results of heart rate readings using the discrete wavelet transform method to facilitate the detection of R peak. This can be obtained by evaluating and studying each decomposition result from level 1 to level 4 on Discrete Wavelet Transform processing using Haar mother wavelets. This study further used a raspberry pi 3B as the microcontroller of the data processor obtained from the ECG module. Based on the results obtained in this study, it can be concluded that in heart rate readings, level 2 decomposition details coefficient had the best value as data processing that helps the heart rate readings with an error value of 0.531% compared to HRV readings that obtained 0.005 using phantom tools and a standard deviation of 0.039. Furthermore, the advantage obtained from this tool is a good precision value in HRV and BPM readings. In reading the HRV of the respondent, it was found that each initial condition of the patient's HRV would be high due to the respondent's unstable condition. The disadvantage of this tool is a delay in running the program and no display in the form of a signal in real time.
Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System Indah Firdausi Nuzula; Priyambada Cahya Nugraha; Moch Prastawa Assalim Tetra Putra; I Dewa Gede Hari Wisana; Riqqah Dewiningrum; Alfi Nur Zeha; Syaifullah Yusuf
Jurnal Teknokes Vol. 19 No. 2 (2026): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v19i2.152

Abstract

SpO₂ is a critical physiological parameter in vital sign monitoring, particularly within Internet of Things (IoT) based healthcare systems that enable continuous and remote patient observation. However, the accuracy of SpO₂ measurements is often compromised by motion artifacts in photoplethysmograph (PPG) signals, which introduce amplitude distortion and frequency spreading that degrade oxygen saturation estimation. Although various signal processing approaches have been proposed, limited studies have evaluated digital filtering performance on real PPG signals using real-time embedded platforms with direct comparison of filter characteristics. This study aims to analyze the effectiveness of two Infinite Impulse Response (IIR) digital filters, Butterworth and Elliptic, in suppressing motion artifacts in SpO₂ signals processed on a microcontroller. Data were collected from ten healthy participants under three  conditions: baseline (no movement), induced finger motion, and filtered signals. Signal quality improvement was assessed using Fast Fourier Transform (FFT), Power Spectral Density (PSD), and Signal-to-Noise Ratio (SNR) analyses. Results indicate that motion artifacts increase high-frequency components above 3 Hz and disrupt the morphological integrity of the PPG waveform. Applying a low-pass IIR filter with a 3 Hz cutoff frequency successfully restored the principal periodic components. The Butterworth filter produced a smoother spectral response with minimal phase distortion, while the Elliptic filter achieved a sharper roll-off with slight passband ripple. Quantitative evaluation demonstrated average SNR improvements of +0.905 dB (Butterworth) and +0.899 dB (Elliptic) using FFT , and +0.98 dB and +0.66 dB, respectively, using PSD. These findings demonstrate that computationally efficient IIR filtering can be reliably implemented in resource-constrained embedded platforms without compromising signal integrity. This approach enhances signal stability, reduces false desaturation alarms, supports scalable deployment in wearable and telemedicine applications, improving patient safety and system robustness in continuous remote health monitoring.
Co-Authors Abd . Kholiq Abdi Wibowo Achmad Rizal Alfi Nur Zeha Amrinsani, Farid Andjar Pudji Anggraini, Navira Anita Miftahul Maghfiroh Arga Wihantara Aulia Rahmawati Ayu Nissa Berlianri Rizhky Bambang Guruh Irianto Cantika Melinda Citra Mahaputri Co’o, Yohanes Cristomus Denis Kurniar Wicaksono Des, Sima Dewi Rushalina Dewiningrum, Riqqah Diana Dwi Damayanti Edy Haryanto Endro Yulianto Era Purwanto Fani Ferina Sani Ferry Kriswandana Firda Ryan Nur Fadhilah Forra Wakidi, Levana Furi Kristya Ginarsih, Yuni Hassaballah, Hayder J. Hayder J Hassaballah Hendra Winarno Her Gumiwang Ariswati Hilmi Yumni Honey Honey I Dewa Made Wirayuda I Gede Susrama I Ketut Edi Purnama Ichwan Syahrul Bahtiar Imam Sarwo Indah Firdausi Nuzula Indrato, Tri Bowo Indriatie Indriatie, Indriatie Ira Puspitasari Ira Rahayu Tiyar Sari Irwan Sulistio Isna Fatimatuz Zahra Isnanto Jarot Hadi Wibowo Juliana Christyaningsih Kumbhare, Ashish Lamidi, Lamidi Levana Fora Wakidi Liliek Soetjiatie Lusiana Lusiana Lusiana Luthfi Rusyadi Luthfiyah, Sari M. Ridha Mak'ruf Maduka Nosike Mahardika, Melva Mansour Asghari Mauridy Harry Purnomo Melinda, Cantika MINARTI Misra, Shubhrojit Mohseena Thaseen Muhammad Fuad Nurillah Muhammad Ridha Makruf Musyahadah Arum Pertiwi Nazila Ragimova Nopriyandi, Nopriyandi Nosike, Maduka Nur Khabibatul Rosida Pandu Arsy Filonanda Pawana, I Putu Alit Priyambada C. Nugraha Priyambada Cahya Nugraha Rathod, Yagnik Retno Sasongko Wati Riqqah Dewiningrum Rizhky, Ayu Nissa Berlianri Rizki Aulia Rachman Rizki Aulia Rachman, Rizki Aulia Rokhmalia, Fitri Rosida, Nur Khabibatul Sasivimon Sukaphat Satheeshkumar Palanisamy Sedigheh Ashgari Baighout Setiawan, Singgih Yudha Setioningsih, Endang Dian setyawanto, nanda dwi Shofiyah Shofiyah Shofiyah Shofiyah Shubhrojit Misra Sima Das Siti Fathul Jannah Siti Mar'atus Slamet Wardoyo Sri Utami Sri Utami Suhartini . Sulistyowati, Dwi Wahyu Wulan Sumber, Sumber Syaifullah Yusuf Taufiqurrahman Tetra Putra, Moch Prastawa Assalim Tobing L Torib Hamzah Triana Rahmawati Triwiyanto Triwiyanto Ulil Albhi Ramadhani Utomo, Bedjo Veriko Yonanto Vidaryanto, Angga Vijay Anant Athavale Vijay Kumar Sharma Yusita Indhira Anwar Zahra, Isna Fatimatuz