PENGARUH JUMLAH LILITAN DAN JENIS MATERIAL COIL PADA PV SOLAR ELECTRIC WARMER DOC Muhamad Zulvi Anam; Asrori Asrori
Steam Engineering Vol. 5 No. 1 (2023): STEAM Engineering, Vol. 5, No. 1, September 2023
Publisher : Program Studi Pendidikan Teknik Mesin, Fakultas Keguruan dan Ilmu Pendidikan, Universitas Palangka Raya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37304/jptm.v5i1.10511

Abstract

DOC brooding period where chicks need heating for development for 14 days with temperatures of 30°C-34°C. During the use of ordinary heating devices, another alternative is to use solar panel-based electric heating because it can save energy sources. The objectives of this research are (1) to determine the effect of variations in the number of coil material turns from 20, 30 and 40 turns on the heat produced by the PV Solar Electric Warmer DOC, (2) to determine the effect of the thermal conductivity of the coil material (copper and nickel) on the heat generated. produced by PV Solar Electric Warmer DOC. The method used is experimental by varying the number of coil windings using thermal conductivity of copper and nickel materials to the heat generated by PV Solar Electric Warmer DOC. The use of variations in the number of coil windings in this study was 20, 30 and 40. The results of this study are the greater the number of coil windings and the type of thermal conductivity affects the heat generated by PV Solar Electric Warmer DOC. In the test copper coil with winding 20 has an average temperature of 30°C, winding 30 averaging 31°C and winding 40 averaging 31°C. When testing nickel materials with the number of windings 20 have an average of 31°C, winding 30 averaging 32°C and winding 40 averaging 33°C. In thermal conductivity testing, nickel coil material reaches the highest temperature of 35° C and copper coil testing reached a high temperature of 32°C
PERBANDINGAN KONSUMSI DAYA BATERAI LI-ION 18650 DENGAN LIFEPO4 32700 BERDASARKAN JARAK TEMPUH Alvatoni Achmad Yusuf
Jurnal Energi Dan Manufaktur Vol 6 No 2 (2023): Oktober 2023
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEM.2023.v16.i02.p05

Abstract

Air pollution is increasing due to emissions from fossil fuel motor vehicles so that electric vehicles are one of the solutions to reduce pollution produced from vehicles. The increase in electric vehicles makes the need for sources of electrical energy increase. Solar panels are an alternative source of renewable electrical energy. Utilization of solar energy requires a battery that functions as energy storage. This research was tested at a distance of 100 meters at a stable speed of 19.78km/h. The results of the test will be read with a data logger system consisting of a voltage sensor, current sensor, speed sensor with Arduino UNO as a microcontroller and Micro SD as a storage medium and an LCD display to display data as a reference during testing in real time. The results of this study are, with the same distance and speed, the total power consumption of LiFePo4 batteries is on average 305.13W greater than Li-Ion. With an average power consumption of 86.17W for LiFePo4 and 69.22 W for Li Ion. Li Ion batteries have the advantage of longer battery life due to less power consumption. Meanwhile, LiFePo4 batteries have the advantage of producing higher power so that vehicle performance is also more optimal, as well as better current and voltage stability which results in more stable power consumption. Keywords: Lithium Ion battery, LiFePO4 battery, transport e-scooter
INSTALLATION OF SOLAR-POWERED ELECTRIC WARMERS FOR DOC-BROODING IN BLITAR CHICKEN FARMERS Asrori Asrori; Eko Yudiyanto; Satworo Adiwidodo; Kris Witono; Cahya Rahmad
Abdi Dosen : Jurnal Pengabdian Pada Masyarakat Vol. 7 No. 4 (2023): DESEMBER
Publisher : LPPM Univ. Ibn Khaldun Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/abdidos.v7i4.2103

Abstract

Community Service (PPM) is held in Sumberejo Village, Sanankulon District, Blitar Regency. Chicken farmers face several challenges related to heating their chicken coops, including restrictions on using subsidized fuel or LPG, which force them to seek other heating alternatives. Leaks in heating systems that use LPG, which pose a fire hazard. Poor air quality and low oxygen levels in coops that use conventional heating methods (firewood and LPG). These challenges can contribute to the decline in the quality of Day-Old Chicks (DOC). This activity aims to install an electric warmer system that produces a safe and comfortable temperature for Day-Old Chicks (DOC) and is easy to use for breeders. In addition, build an independent energy source to run the heat treatment system equipment in the DOC-Brooding area with a solar panel installation. The installed 600 Wp PLTS system consists of 4 solar panels with a capacity of 150 Wp each, an 850 VA hybrid inverter and 100 Ah VRLA battery. Electrical energy from PLTS can power a 200 W electric warmer. The solar panel installations can produce an average of 3.6 kWh of electrical energy/day. So that the electricity savings from PLN can reach IDR. 162000 per month.
UTILIZATION OF A PICO HYDRO POWER PLANT AT AL-IKHLAS ISLAMIC BOARDING SCHOOL IN MALANG REGENCY Mohammad Noor Hidayat; Ferdian Ronilaya; Irwan Heryanto Eryk; Sapto Wibowo; Asrori Asrori; Masramdhani Saputra
Abdi Dosen : Jurnal Pengabdian Pada Masyarakat Vol. 7 No. 4 (2023): DESEMBER
Publisher : LPPM Univ. Ibn Khaldun Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/abdidos.v7i4.2098

Abstract

Al-Ikhlas Yatim Dhuafa Islamic Boarding School is ± 12.6 km from Malang City. If you look at it geographically, the location of this community service program is located at coordinates 7°58'27.0"S 112°48'14.8"E. To support activities in this tourist area, electrical energy is really needed, especially for lighting facilities and charging electronic equipment. This Community Service Program will be implemented between April and November 2022 with activities in the form of building a pico hydro power plant in the Al-Ikhlas Yatim Dhuafa Islamic Boarding School area, Singosari District, Malang Regency. In carrying out this community service program, there is one activity partner, namely the Al-Ikhlas Yatim Dhuafa Islamic Boarding School with a total of 6 personnel. The results of this community service program are the installation and operation of a pico hydro power plant with a capacity of 1000 watts. This pico hydro power plant can meet electricity needs in the Islamic boarding school area with a total power of around 450 watts. In order for the pico hydro power plant to operate according to its capacity, it is necessary that the operation and maintenance of the system equipment be carried out correctly and on a schedule. For this reason, the transfer of knowledge and skills to work partners, namely the management of the Al-Ikhlas Yatim Dhuafa Islamic Boarding School, has been carried out.
APLIKASI TEKNOLOGI BIO-DRYING UNTUK PROSES PENGERINGAN SAMPAH ORGANIK MENJADI BAHAN BAKAR Eko Naryono; Cucuk Evi Lusiani; Ariani Ariani; Khalimatus Sa'diyah; Asrori Asrori
RESWARA: Jurnal Pengabdian Kepada Masyarakat Vol 5, No 1 (2024)
Publisher : Universitas Dharmawangsa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46576/rjpkm.v5i1.3740

Abstract

Desa Wringinsongo merupakan desa binaan dari Politeknik Negeri Malang (Polinema) sejak tahun 2020 dan menjadi mitra kegiatan pengabdian kepada masyarakat (PkM). Berdasarkan hasil diskusi antara Jurusan Teknik Kimia, Polinema dan warga Desa Wringinsongo, salah satu masalah di desa tersebut yang dapat diselesaikan sesuai dengan bidang ilmu di Jurusan Teknik Kimia adalah pengolahan sampah menjadi bahan bakar. Permasalahan sampah yang mencemari lingkungan di Desa Wringinsongo disebabkan banyaknya sampah yang ditinggalkan oleh pengunjung terutama di daerah wisata pemandian alam. Teknologi bio-drying melalui proses pengeringan sampah menjadi bahan bakar dapat digunakan sebagai alternatif solusi yang ramah lingkungan yang dapat diwujudkan dalam bentuk kegiatan PkM. Hal ini sejalan dengan Rencana Strategis Polinema (Renstra Polinema 2021-2025) di bidang pemeliharaan lingkungan hidup dan pengelolaan Sumber Daya Alam (SDA) untuk Desa Binaan Polinema, Wringinsongo, Kec. Tumpang, Kab. Malang. Kegiatan PkM yang dilaksanakan pada bulan Juni-Agustus 2022 berjalan lancar dan para peserta sangat antusias untuk mempraktikkan secara langsung pengeringan sampah organik dengan metode teknologi bio-drying untuk dijadikan sebagai bahan bakar alternatif
Hubungan Penggunaan Special Tool Terhadap Proses Pemasangan Pin Pada End Arm Excavator Pc200 M. Hilmi Syiva Afiat; Asrori Asrori
Student Research Journal Vol. 2 No. 3 (2024): Juni:Student Research Journal
Publisher : Sekolah Tinggi Ilmu Administrasi (STIA) Yappi Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/srjyappi.v2i3.1326

Abstract

Working in the mining sector has a fairly high occupational risk, especially for mechanics in carrying out heavy equipment maintenance. One of the maintenance carried out is the replacement of the excavator bucket. The excavator bucket is mounted on the end arm of the excavator which is connected using a locking pin. The pin installation process is carried out by hitting with a hammer, where this process has a number of occupational risks such as being hit, exposed to material, and fatigue which can result in work accidents. This study aims to minimize the occurrence of occupational risks by finding out the relationship between the use of special tools on safety and job duration for the locking pin installation process. The method used is experimental quantitative method and using fishbone diagram. By using a special tool, the installation of locking pins becomes safer because the factors that cause accidents when using palju can be eliminated and the manpower required becomes more efficient, but in terms of time it requires a longer duration due to the limitations of the tool that requires adjustment several times when used.
The effect of solar tracker movement on the thermal performance of solar cooker using the Fresnel lens solar concentrator Asrori Asrori; Sugeng Hadi Susilo; Kris Witono; Putu Wijaya Sunu
Jurnal POLIMESIN Vol 20, No 2 (2022): August
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v20i2.2652

Abstract

Solar energy as renewable energy has great potential to supply the world's energy needs. Solar thermal energy can be used for domestic energy purposes (cooking and water heating). The purpose of this research is to develop, design and analyze the performance of a solar cooker from the concentration of direct normal irradiance (DNI) by the Fresnel lens on the receiver/absorber as a cooking vessel. One form of improving the performance of the Fresnel solar concentrator (FSC) is the addition of an automatic solar tracker installation using hydraulic actuators. The solar tracker is varied, every 5 and 10 minutes, respectively. The solar cooker performance test was conducted outdoors at the Mechanical Engineering Department of State Polytechnic of Malang (7.9553 oS and 112.6125 oE) in April 2021. The method used actual experimental research. The measurement of solar radiation uses a solar power meter SPM-1116SD and the tracker's movement. At the same time, the temperature parameters (water temperature, receiver wall temperature, focal point temperature, ambient temperature) are measured by the temperature data logger. The concentrated solar cooker type design uses a fresnel lens with a capture area of 0.785 m2 and a focal ratio of 0.88. The main components of this solar cooker design consist of: a large fresnel lens that functions as a concentrator of sunrays, a cone-shaped cooking stove as a solar collector (receiver), and a hydraulic actuator-type solar tracker unit. Initial tests showed that the solar radiation, In = 789.00 W/m2, obtained the focal point temperature at the receiver, Tf = 930.10°C. Meanwhile, the thermal efficiency (Th) of a solar cooker with a solar tracker that moves every 10 minutes and 5 minutes is 12.7% and 33.66%, respectively. The increase in the thermal efficiency of the solar cooker is very significant, which is 2.65 times. This shows that the more accurate and continuous movement of the tracker will increase the thermal efficiency of the designed Fresnel solar cooker.
The Effect of embossing roll roughness and forming temperature on damage to menthol-coated aluminum foil on packaging Ludfi Setiawan; Asrori Asrori
Jurnal POLIMESIN Vol 21, No 4 (2023): August
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/jpl.v21i4.4104

Abstract

The Aims of this study are to determine  the effect of embossing roll roughness and forming temperature on the damage of menthol-coated aluminum foil on the packaging, and to determine the best temperature and embossing roll roughness on the quality of the menthol coating on the packaging. In this study, the independent variables were embossed roll wave (roughness level 1000,500.0 µm) and menthol foil temperature (22, 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46 °C) to be manipulated, observed, and measured to know the effect with the dependent variable. And because the established variable is the quantity of broken menthol foil packaging that is measured via way of means of calculating the share of period of menthol foil packaging this is torn as compared to the whole period of the foil. Based on the effects of the discussion, it can be concluded that the forming temperature and the embossing roll roughness affect the damage to the menthol packaging layer. In the ANOVA follow-up test, the lowest and best mean value for the forming temperature is at T12 or 44°C, not at T13 or 46°C because at these temperatures the menthol layer on the package is too hot and starts to damage the coating and the lowest and best average for the roughness level of embossed rolls is at E3 with a roughness value of 0 µm (fine).
Hasil Variasi Media Quenching Terhadap Kekuatan Tarik Baja S45C Sulistyono Sulistyono; M Hasyim Nurwansyah; Asrori Asrori
Jurnal Rekayasa Mesin Vol 18, No 2 (2023): Volume 18, Nomor 2, Agustus 2023
Publisher : Mechanical Engineering Department - Semarang State Polytechnic

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/jrm.v18i2.3873

Abstract

Dalam penelitian ini, baja S45C akan diuji dan dibandingkan nilai kekuatan tarik yang dimiliki sebelum dan setelah diberikan perlakuan panas Quench Hardening. Suhu pemanasan yang digunakan dalam proses perlakuan panas ialah 850 ℃, dengan holding time yaitu 30 menit. Media quenching yang digunakan yaitu “Es Batu Ditambah Air”, “Larutan NaCl 3,45%”, dan “Oli SAE 10W-30”. Hasil dari pengujian tarik menunjukkan bahwa media quenching “Es Batu ditambah Air” dan media quenching “Larutan NaCl 3,45%” menghasilkan rata-rata nilai kekuatan tarik 156,27 MPa dan 228,55 MPa, sementara pada raw material dan media quenching “Oli SAE 10W-30” menghasilkan rata-rata nilai kekuatan tarik 707,03 MPa dan 1.116,30 MPa.
Pengaruh Jenis Sensor terhadap Persentase Eror Sensor Parkir Berbasis STM32 Qais Rakhmanda Yoga Pratama; Asrori Asrori
Jurnal Teknik Mesin, Industri, Elektro dan Informatika Vol. 3 No. 3 (2024): September : JURNAL TEKNIK MESIN, INDUSTRI, ELEKTRO DAN INFORMATIKA
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jtmei.v3i3.4120

Abstract

This study evaluates the impact of sensor type on the percentage error in an STM32-based parking sensor system by comparing the HY-SRF05 and JSN-SR04T ultrasonic sensors. The aim of this research is to determine the accuracy of each sensor in distance measurement and identify the more reliable sensor for parking sensor applications. The methodology includes installing both sensors on the STM32 system, measuring distances at various intervals, and analyzing the percentage error. The results indicate that the HY-SRF05 sensor exhibits a lower percentage error compared to the JSN-SR04T across all tested distances, from 50 cm to 300 cm. The average percentage error for the HY-SRF05 is 1.78%, while for the JSN-SR04T it is 2.6%. The conclusion of this research is that the HY-SRF05 sensor is more accurate and reliable than the JSN-SR04T for STM32-based parking sensor applications.
Co-Authors Abdullah Helmy Ach. Muhib Zainuri Ach. Muhib zainuri Agus Harijono AGUS SETIAWAN Agus Sujatmiko Agus Sujatmiko Akhmad Faizin Ariani Ariani Asfari Hariz Santoso BAYU PRANOTO Cucuk Evi Lusiani Dani, Agus Dony Perdana Eko Naryono Eko Naryono Eko Yudiyanto Elka Faizal Eryk Eryk Faizal, Elka Faizul Ahmad Jatmiko FATHUR ROHMAN gumono Hari Rarindo Harie S. Jaya Harijono, Agus Haris Puspito Buwono Hilmi Iman Firmansyah Imam Mashudi IRWAN HERYANTO ERYK Irwan Heryanto/Eryk Jaya Harie Satiyadi Khalimatus Sa'diyah Kris Witono Kris Witono Kurnia, Arindrian Lisa Agustriyana Ludfi Setiawan Lulut W M Hasyim Nurwansyah M. Hilmi Syiva Afiat M. N. Wahyudi Abdullah M. Zusriansyah Fahrudin Harahap Mardyansyah, AA Martawati, Mira Esculenta Maskur Maskur Masramdhani Saputra Mira Esculenta Martawati Mira Esculenta Martawati Mirza Fathus Syifa Alfarisyi Moh. Hartono Mohammad Noor Hidayat Mohammad Noor Hidayat Mokhammad Khatami Muhamad Hanifudin Muhamad Zulvi Anam Muhammad Fakhruddin Nanang Qosim Novembrian Isam Dinata Nugroho Suharto Nugroho, Pipit Wahyu Nurhadi - Pondi Udianto Priya Surya Harijanto Putu Wijaya Sunu Qais Rakhmanda Yoga Pratama R.N. Akhsanu Takwim, R.N. Akhsanu Rahmad, Cahya Rahmat Muhamad Hudan Raihan Insan Nararya Ridho Ilham Ronilaya, Ferdian Sapto Wibowo Satworo Adiwidodo Subagiyo Subagiyo Sugeng Hadi Sugeng Hadi Susilo Sugeng Hadi Susilo Sugeng Hadi Susilo Sugeng Hadi Susilo Sulistyono Sulistyono Suyanta Suyanta Syamsul Ph.D M.A. Hadi Thomas Adikusuma Walid, Achmad Yudianto, Eko