ANALISIS PEMERIKSAAN MSCT SCAN THORAX DENGAN KONTRAS MEDIA INTRAVENA PADA KLINIS YANG TERDIAGNOSIS TUMOR PARU DI RS BHAYANGKARA MAKASSAR Dirza Sudirman, Zulfa; Prasetya, I Made Lana; Mahendrayana, I Made Adhi
PREPOTIF : JURNAL KESEHATAN MASYARAKAT Vol. 8 No. 3 (2024): DESEMBER 2024
Publisher : Universitas Pahlawan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/prepotif.v8i3.35036

Abstract

Thorax merupakan rongga berbentuk kerucut yang dilapisi tulang rawan dan tulang asli. Beberapa penyakit yang sering terjadi pada rongga dada adalah tumor atau massa, gangguan sirkulasi, radang, trauma, gangguan perikardium, serta infeksi rongga dada lainnya. MSCT Scan Thorax kontras adalah prosedur yang menggunakan zat kontras untuk memperjelas struktur dan organ di dalam dada. Kelainan seperti tumor, pembuluh darah yang tersumbat atau bocor, peradangan dan infeksi di dalam dada dapat diidentifikasi menggunakan zat kontras. Penelitian ini bertujuan untuk mengetahui prosedur pemeriksaan MSCT Scan Thorax dengan kontras media intravena pada klinis yang terdiagnosis tumor paru sekaligus mengevaluasi kelebihan dan kekurangan penggunaan slice thickness 3-5 mm dan delay 35 detik. Desain penelitian ini adalah penelitian deskriptif kualitatif dengan pendekatan studi kasus menggunakan subjek tiga radiografer, dua dokter spesialis radiologi, satu dokter pengirim, dan tiga pasien. Data dikumpulkan melalui observasi, wawancara dan dokumentasi. Metode analisis data yang digunakan adalah pengumpulan data, pengolahan data, penyajian data dan penarikan kesimpulan. Hasil penelitian menunjukkan bahwa prosedur ini melibatkan persiapan pasien, persiapan alat dan bahan, serta pelaksanaan scanning. Protokol Chest -C digunakan untuk scanning pre-kontras, sementara Chest +C untuk post-kontras dengan penggunaan injector pada flow rate 1,5 mL/detik serta volume media kontras dan saline (NaCl) sekitar 50 mL. Penggunaan slice thickness 3-5 mm meningkatkan detail anatomi dan deteksi lesi kecil dengan lebih baik, sedangkan delay 35 detik membantu memperjelas perfusi paru serta pembuluh darah arteri dan vena. Meskipun prosedur ini efektif dalam diagnosis tumor paru, durasi pemeriksaan yang lebih lama dapat menimbulkan ketidaknyamanan bagi pasien.
PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA Purnama Dewi, Gusti Agung Putu Adhinta; Prasetya, I Made Lana; Sugiantara, I Wayan Ariec
Journal of Applied Health Management and Technology Vol 6, No 2 (2024): October 2024
Publisher : Politeknik Kesehatan Kementerian Kesehatan Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jahmt.v6i2.11947

Abstract

Background: This research on the performance testing of the Magnetic Resonance Imaging (MRI) machine was conducted using performance tests on three different parameters at Kasih Ibu Hospital Saba. This research aims to determine the performance of the MRI machine at Kasih Ibu Hospital Saba in Bali Province and establish baseline data for future testing. Method: This type of research is quantitative and uses a survey approach. The tools and materials used in this study are a 0.35 Tesla MRI machine, an ACR phantom, and a head coil. Data were collected by conducting nine MRI performance testing procedures using the ACR (2015) guidelines and then analyzed using international standards issued by ACR (2015). Result: In the visual checklist testing, all observed parameters were over 30 days and functioned well, For the Artifact Evaluation test, the author evaluated all scanned images and found no artifacts. The author analyzed the measurements from the first slice of T1W and T2W images for the Slice Thickness Accuracy test. The measurement results for the T1W image were 4.6mm, and for the T2W image, they were 5.57mm. The Slice Thickness Accuracy testing standard set by ACR in 2015 is 5mm ± 0.7mm. Therefore, based on the measurement results from the T1W and T2W images, the MRI machine at Kasih Ibu Saba Hospital meets the established international standards. Conclusion: Based on the results of the visual checklist test, the following results were obtained: all parameters on the visual checklist functioned well during the 30-day observation. Meanwhile, the two tests conducted with the phantom on the MRI machine at Kasih Ibu Hospital Saba the following results are: the artifact evaluation test and the slice thickness accuracy test met the international standards set by ACR in 2015.
Terapi Radiasi Eksternal dengan Metode Hypofractionated pada Kanker payudara Post Breast Conserving Surgery di Instalasi Onkologi Radiasi Rumah Sakit Indriati Solo Baru: Studi Kasus Rorong, Fabrizio Alessandro; Prasetya, I Made Lana; Juliasa, I Wayan
Jurnal Imejing Diagnostik (JImeD) Vol 11, No 1 (2025): JANUARY 2025
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v1i1.11878

Abstract

Background: Radiotherapy is one method of cancer treatment that uses radiation to destroy cancer cells. Radiation dose delivery is done gradually through a process called fractionation, which is divided into conventional and hypofractionated fractions. In the radiation oncology installation of the new Indriati Solo Hospital, some breast cancer patients have received treatment with the hypofractionated method, while the majority still use the conventional fraction method. The hypofractionated method aims to reduce the number of treatment sessions by increasing the dose in each fraction with outcomes comparable to conventional fractions.Methods: This research method is descriptive qualitative with a case study approach. The study involves breast cancer patients post-Breast Conserving Surgery (BCS), Data were gathered through interviews with radiation oncologists, radiotherapists, and medical physicists, along with direct observations and patient record analysis The collected data were analyzed descriptively to evaluate the application and effectiveness of the hypofractionated method.Results: The results showed that the use of hypofractionated can shorten OTT (Overall Treatment Time), as well as better side effects than conventional fractions, and effectively reduce the number of queues of radiotherapy patients. In conclusion, the use of the hypofractionated method is very effective and recommended for radiotherapy treatment in breast cancer.Conclusions: Hypofractionated radiotherapy for breast cancer patients at Indriati Solo Baru has proven effective in reducing OTT and patient queues, with outcomes comparable to conventional fractionation. Further research is needed to assess long-term benefits, including quality of life, recurrence rates, cost-effectiveness, and dose distribution, particularly in high-volume healthcare settings. Hypofractionated radiotherapy is a promising alternative.
Teknik Pemeriksaan Magnetic Resonance Imaging (MRI) Brain Dengan Penambahan Sequence Axial 3D-Fiesta Pada Kasus Facial Tic Ameliya Widya Astuti; I Made Lana Prasetya; Teguh Hariyanto
Compromise Journal Community Proffesional Service Journal Vol. 1 No. 4 (2023): Compromise Journal : Community Proffesional Service Journal
Publisher : LPPM STIKES KESETIAKAWANAN SOSIAL INDONESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57213/compromisejournal.v1i4.34

Abstract

Magnetic Resonance Imaging is a medical device that combines computer technology, strong magnetic fields and radio waves to emulate representations of human body parts and produce more detailed and clear images, one of which is Facial Tic on the Brain. The MRI Brain examination aims to see the anatomy and abnormalities in the brain. This study aims to determine the MRI Brain examination procedure and the role of the Axial 3D Fiesta sequence in cases of Facial Tic. Use of the 3D Fast Imaging Employing Steady State Acquisition (FIESTA) sequence for evaluation of the head nerves. The research method used is descriptive research with a case study approach. Data collection was carried out from July 2023 to August 2023 using a GE 1.5 Tesla MRI aircraft. The subject consisted of a patient with clinical Facial Tic. Data collection was carried out through observation, interviews and documentation. The research results were obtained according to theory using sagittal T1, Coronal PD/T2, Axial PD/T2/T1/FLAIR/EPI, Axial 3D incoherent GRE T1, Axial/oblique SE MT, Axial DWI, Diffusion Tensor Imaging (DTI), Axial perfusion sequences. imaging, while in the field using localizer sequences, Axial DWI, Axial T2 Flair, Axial T2, Axial T1, Axial T2* GRE, Sagittal T1, Coronal T2, and Axial 3D Fiesta
Analisis Pemeriksaan CT Scan Kepala Kontras pada Kasus Tumor Otak Di Rumah Sakit Santosa Bandung Kopo Salsabila, Nabilah; Prasetya, I Made Lana; Mahendrayana, I Made Adhi
Jurnal Sehat Indonesia (JUSINDO) Vol. 7 No. 1 (2025): Jurnal Sehat Indonesia (JUSINDO)
Publisher : Publikasi Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59141/jsi.v7i01.223

Abstract

Penelitian ini berfokus pada Analisis Pemeriksaan CT Scan kepala kontras pada pemeriksaan Tumor Otak di Rumah Sakit Santosa Bandung Kopo, Tumor adalah formasi sel atipikal. Sel adalah komponen dasar yang menyusun jaringan dan organ di seluruh tubuh. Tumor otak ditandai dengan proliferasi sel-sel abnormal yang berkumpul, sehingga menghambat fungsi normal otak. Penelitian ini menggunakan metode deskriptif kualitatif dengan pendekatan studi kasus, mengamati 3 pasien Tumor Otak. Pengumpulan data dilakukan melaui observasi, wawancara, dan dokumentasi dengan tujuan utama mengevaluasi penggunaan klinis CT Scan kepala kontras dalam mendeteksi dan mendiagnosa Tumor Otak. Hasil penelitian menunjukkan bahwa penggunaan ketebalan irisan 5mm dalam CT Scan di Rumah Sakit Santosa Bandung Kopo efektif untuk memvisualisasikan patologi Tumor Otak. Penelitian ini menyimpulkan Kelebihan dan kekurangan dari Slice Thickness 5 mm pada pemeriksaan CT Scan Kepala Kontras Pada Kasus Tumor Otak yaitu memiliki kelebihan dapat mendiagnosa kelainan tumor pada kepala, pemeriksaannya lebih cepat dan sederhana, peralatan yang digunakan lebih sedikit dan efesiensi waktu. Kekurangannya yaitu detail anatomi kecil atau lesi yang kecil mungkin tidak terdeteksi ataupun akan tampak kabur.
Perbedaan Kualitas Citra MRI Pelvis Pada Kasus Kanker Prostat dengan Variasi B Value Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G Ngoerah Luh Eka Aza Pratiwi; I Made Lana Prasetya; I Putu Sugiartha
Jurnal Ventilator Vol. 1 No. 4 (2023): Desember : Jurnal Ventilator
Publisher : Stikes Kesdam IV/Diponegoro Semarang, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59680/ventilator.v1i4.673

Abstract

B value is a factor that reflects the strength and timing of the gradient that will be used to generate a diffusion-weighted image. The higher the b value, the stronger the effect on diffusion. B value can be expressed in units of s/mm2 with a b value range of 500 s/mm2 to 1500 s/mm2. The use of b value in Diffusion Weighted Imaging (DWI) sequences is very important in detecting prostate cancer to distinguish malignant and benign cancer tissue because b value determines the amount of diffusion weighting and shows the sensitivity of the sequence to diffusion. The purpose of this study is to determine the difference in the quality of SNR and CNR images with b value variations in Pelvic MRI examination in prostate cancer cases. This study uses quantitative research methods with an experimental approach. The study population and samples were 4 Pelvic MRI patients with prostate cancer cases who underwent examination in July-August 2023 at the Radiology Installation of Prof.Dr.I.G.N.G Ngoerah Hospital, and each sample was subjected to b value variations of 800, 1000, 1400 and 2000 on the Diffusion Weighted Imaging (DWI) sequence. Data were processed using radiant DICOM and then analyzed using normality test and repeated anova test on SPSS 25 software. The results showed a significance value (p-value) > than 0.05, it can be concluded that H0 is accepted and Ha is rejected, which means that there is no difference in Pelvic MRI image quality in Prostate Cancer Cases with b value variations. The b value variation of 800 on Pelvic MRI examination on Diffusion Weighted Imaging (DWI) sequences with prostate cancer cases can produce more optimal image quality compared to b value variations of 1000, 1400 and 2000.
Optimalisasi Nilai CNR Perbandingan Aplikasi Short TE (STE) dan Ultrashort TE (UTE): Studi Komparasi Citra MRI Genu Pembobotan T1wi Turbo Spin Echo (TSE) di Instalasi Radiologi Rumah Sakit Daerah Mangusada Badung: Optimization Of Cnr Value With Application Comparison Short TE (STE) and Ultrashort TE (UTE): Comparative Study of Genu MRI Images Weighted T1wi Turbo Spin Echo (TSE) in The Radiology Installation of Mangusada Regional Hospital Badung Dharma Laksmi, Made Ayu; Lana Prasetya, I Made; Supriyani, Nyoman
Jurnal Surya Medika (JSM) Vol. 11 No. 1 (2025): Jurnal Surya Medika (JSM)
Publisher : Institute for Research and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33084/jsm.v11i2.7380

Abstract

Sendi Lutut merupakan sendi terbesar dan paling kompleks pada tubuh manusia yang terdiri dari Anterior Cruciate Ligament, Posterior Cruciate Ligament, dan patella tendon. Salah satu parameter MRI adalah TE. Short TE (STE) mengacu pada teknik pencitraan MRI yang menggunakan TE yang relatif singkat. Ultrashort TE (UTE) menggunakan TE yang sangat pendek dan memungkinkan pencitraan struktur seperti tendon dan tulang kortikal. Jenis penelitian yang digunakan adalah kuantitatif dengan pendekatan studi eksperimen. Penelitian dilakukan di Instalasi Radiologi RS Mangusada Badung dengan rasio STE dan UTE dengan nilai TE 16 ms dan 0,8 ms. Pengukuran CNR dilakukan pada area yang akan dievaluasi yaitu anatomi Anterior Cruciate Ligament dan Posterior Cruciate Ligament. Hasil penelitian menunjukkan CNR citra MRI Genu potongan sagital antara aplikasi T1WI TSE STE dan T1WI TSE UTE dengan p-value signifikan <0,05. Hasilnya perbandingan CNR optimal antara aplikasi STE dan UTE adalah variasi UTE dengan nilai mean rank 16,67 untuk ACL dan 11,05 untuk PCL. Dari hasil uji beda Wilcoxon tiap variasi diperoleh p-value ACL 0,016, PCL 0,008, p-value keseluruhan 0,005 sehingga terdapat perbedaan. Uji Wilcoxon mean rank kualitas gambar mean rank tertinggi diperoleh dari UTE, sehingga UTE mampu menghasilkan CNR pada organ yang optimal dibandingkan dengan STE.
Rancang Bangun kVp Meter Divolx Berbasis Hyperterminal di Laboratorium ATRO Bali: Development of Divolx kVp Meter Based on Hyperterminal at ATRO Bali Laboratory Prasetya, I Made Lana; Satria Mahendra, I Dewa Gede; Dwi Putra, Geovani Ega
Jurnal Surya Medika (JSM) Vol. 11 No. 1 (2025): Jurnal Surya Medika (JSM)
Publisher : Institute for Research and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33084/jsm.v11i2.7388

Abstract

Pesawat sinar-X adalah instrumen diagnostik penting dalam kedokteran modern yang menggunakan tabung hampa untuk menghasilkan sinar-X guna mengevaluasi kondisi internal pasien melalui gambar radiologi. Penggunaan sinar-X ini, meskipun memberikan manfaat tanpa perlu melakukan operasi, memiliki risiko paparan radiasi yang tinggi. Oleh karena itu, manajemen keselamatan radiasi menjadi krusial untuk melindungi kesehatan pekerja, pasien, dan lingkungan sekitar. Penelitian ini bertujuan untuk mengembangkan kVp meter yang lebih terjangkau berbasis Hyperterminal sebagai alternatif terhadap kVp meter digital yang mahal. Metode penelitian yang digunakan adalah deskriptif kualitatif dengan pendekatan eksperimental. Prototipe yang dikembangkan, yang dinamakan Divolx, telah diuji keakuratannya dalam mengukur tegangan tabung sinar-X dengan membandingkannya dengan alat standar, Raysafe, di laboratorium ATRO Bali. Hasil penelitian menunjukkan bahwa Divolx mampu memberikan hasil pengukuran yang mendekati akurasi alat standar. Persentase keakuratan tertinggi yang dicapai oleh Divolx adalah 99.53% pada pengaturan 40 kV. Meskipun terdapat beberapa penyimpangan pada pengaturan tegangan tertentu, nilai persentase error Divolx menunjukkan tingkat akurasi yang dapat diandalkan untuk pengukuran tegangan tabung sinar-X. Kesimpulannya, pengembangan Divolx berhasil menciptakan kVp meter yang ekonomis namun tetap akurat, sesuai dengan spesifikasi yang direncanakan. Alat ini memiliki resolusi pembacaan 0.01 kV dengan rentang nilai pembacaan 40-60 kV, memperkuat kemampuannya sebagai alat alternatif yang dapat digunakan dalam praktek radiodiagnostik dengan aman dan efektif.
Analisis Kualitas Citra MRI Brain pada Sekuen TI Space (Studi Komperasigrappa) pada Kasus Epilepsi Potongan Coronal di Unit Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah Denpasar: Analysis of MRI Brian Image Quality on TI Space Sequence (Comparative Study of Grappa) in Epilepsy Cases in Coronal Section at the Radiology Unit RSUP Prof. Dr. I.G.N.G. Ngoerah Denpasar Willa, Dhea Charmelita; Lana Prasetya, I Made; Sari Widari, Ni Luh Putu
Jurnal Surya Medika (JSM) Vol. 11 No. 1 (2025): Jurnal Surya Medika (JSM)
Publisher : Institute for Research and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33084/jsm.v11i2.7713

Abstract

Epilepsi adalah gangguan otak kronis yang ditandai dengan adanyakejang berulang . kondisi ini dapat menyerang orang dengan usia berapa pun. grappa adalah teknik yang dapat memperpendek waktu pemindaian tanpa mengorbankan kualitas citra, membantu mengurangi ketidaknyamanan pasien dan mengatasi artefak pergerakan. Dilakukannya penelitian ini yaitu, untuk mengevaluasi secara komperatif kualitas citra MRI yang dihasilkan oleh T1 space grappa dan non grappa, dengan fokus pada identifikasi lesi pada pasien epilepsi. Jenis penelitian yang digunakan yaitu kuantitatif dengan pendekatan studi eksperimental. Sampel yang digunakan terdiri dari 5 pasien pemeriksaan MRI Brain kasus epilepsi, pada masing-masing akan diterapkan grappa dan non grappa sekuen T1 Space potongan coronal. Data yang diperoleh diolah menggunakan perangkat lunak Radiant DICOM dan dianalisis dengan uji normalitas serta uji Paired T-Test menggunakan SPSS 25. Hasil uji normalitas menunjukkan bahwa nilai signifikansi (p-value) untuk CNR dengan grappa > 0,05, menunjukkan bahwa data CNR terdistribusi normal. Oleh karena itu, uji beda (Paired T-Test) dilakukan, menghasilkan nilai Asymp. Sig (p-value) pada data grappa HC_GM adalah 0.003, non grappa HC_GM adalah 0,009, nilai p-value menunjukkan (p<0,05) maka dapat disimpulkan bahwa Ha diterima dan Ho ditolak. Artinya terdapat perbedaan CNR pada pemeriksaan MRI Brain sekuen T1 space potongan coronal dengan penerapan grappa dan non grappa.
Prosedur Pemeriksaan CT Scan Kepala dengan Klinis Stroke Homeragik di Instalasi Radiologi RSUD dr. R. Soedjonio Selong: Procedure of Head CT Scan Examination for Patients with Hemorrhagic Stroke at the Radiology Department of dr. R. Soedjono Selong General Hospital Dunantiko, Hendri; Lana Prasetya, I Made; Wijaya, Nyoman Moga
Jurnal Surya Medika (JSM) Vol. 11 No. 1 (2025): Jurnal Surya Medika (JSM)
Publisher : Institute for Research and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33084/jsm.v11i2.9748

Abstract

Penelitian ini bertujuan untuk mengevaluasi prosedur pemeriksaan CT scan kepala pada pasien dengan klinis stroke hemoragik di Instalasi Radiologi RSUD Dr. R. Soedjono Selong, dengan fokus pada penggunaan slice thickness 1 mm yang berbeda dari standar umum. Pendekatan studi kasus kualitatif digunakan, melibatkan observasi langsung, wawancara semi-terstruktur dengan tenaga medis, dan analisis dokumentasi. Hasil penelitian menunjukkan bahwa penerapan slice thickness 1 mm memberikan resolusi spasial yang lebih tinggi, yang penting untuk mendeteksi detail kecil seperti perdarahan intrakranial. Prosedur ini memungkinkan fleksibilitas dalam rekonstruksi citra multiplanar tanpa kehilangan kualitas gambar, yang sangat penting dalam diagnosis dan penanganan stroke hemoragik. Selain itu, penggunaan slice thickness 1 mm mendukung akurasi pengukuran volume perdarahan melalui perangkat lunak Volume Calculate 3D, yang merupakan komponen kritis dalam menentukan strategi terapi. Integrasi sistem Radiology Information System (RIS) dan Picture Archiving and Communication System (PACS) dengan Elektronik Medical Record (EMR) juga memastikan efisiensi alur kerja dari pendaftaran pasien hingga analisis citra. Kesimpulannya, prosedur ini tidak hanya memenuhi standar radiologi modern tetapi juga memberikan model yang dapat diadaptasi oleh rumah sakit lain, khususnya di wilayah dengan sumber daya terbatas. Temuan ini menegaskan pentingnya inovasi dalam prosedur radiologi untuk meningkatkan akurasi diagnostik dan kualitas layanan kesehatan dalam penanganan stroke hemoragik.
Co-Authors AA. Aris Diartama Alan Pratama Ameliya Widya Astuti Cokorda Istri Emi Dwiyanti Cory Amelia Dharma Laksmi, Made Ayu Dharmawan, Bagus Gede Diartama, A.A Aris Diartama, AA. Aris Dirza Sudirman, Zulfa Dunantiko, Hendri Dwi Putra, Geovani Ega Evhal Yulianus Fachry Abda El Rahman Fasya Enjelika Unmehopa Gatot Murti Wibowo Gatot Murti Wibowo, Gatot Murti Gede Dharma Putra Hari Santoso Hari Santoso Hariani, Ida Ayu Sutresna Hasan, Andi Fitrianti Hascaryo, Dwi HENDRA SETIAWAN I Bagus Gede Dharmawan I Kadek Sukadana I Kedek Sukadana I Made Adhi Mahendrayana I Made Adhi Mahendrayana I Putu Eka Juliantara I Putu Juli Arthana I Putu Sugiartha I Wayan Ariec Sugiantara I Wayan Ariec Sugiantara Iman Nuriman Intan Lesmanasari Juliasa, I Wayan Kusman Kusman Kusman Kusman Kusman, Kusman Luh Eka Aza Pratiwi Mahendrayana, I Made Adhi Mahendrayana, I Made Adi Mughnie, Burlian Muh Anas Muh Anas Muh Anas, Muh Anas Nadra Nandika A.J Mokoagow Nelce Silvia Panggaliau Ni Putu Rita Jeniyanthi Novinda Syamantha Djawa Prita Prita Prita, Prita Purnama Dewi, Gusti Agung Putu Adhinta Putra, Gede Pramana Rafa Zenitha Azzahra Rahmat widodo Restiana, Restiana Retno Laksmi Faraningrum Retno Laksmi Faraningrum Rifaldi Mokodenseho Rorong, Fabrizio Alessandro Ruvinaningsih, Putri Salsabila, Nabilah Santo Aloya Dearta Saragih Sari Widari, Ni Luh Putu Sastrawan, I Putu Manik Satria Mahendra, I Dewa Gede Serly Olivia Natalia Dato Siagian, Mega Krisna Sianturi, Amser Sunarto Sugiantara, I Wayan Ariec Suhariadi Atmanta Sujuddi, Dimas Irfanuary Eka Sukadana, I Kedek Supriyani, Nyoman Susanta, I Putu Adi Susanta, Putu Adi Taufani, Maria Selania Teguh Hariyanto Tri Asih Budiati Triningsih Triningsih Triningsih Triningsih Tri Asih Budiarti Valeria Alex Wahyu Jaya Andre Saputra Wijaya, Nyoman Moga Willa, Dhea Charmelita Wulandari, Putu Irma Yulianus, Evhal Zenitha Azzahra, Rafa Zul Fikra