Comparing Temperature and Humidity Control Using PID and Fuzzy Logic in a Climatic Chamber Putra, Affan Kurnia; Rahmawati, Triana; Assalim T.P, Moch.Prastawa; Misra, Shubhrojit
Jurnal Teknokes Vol. 17 No. 2 (2024): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The presence of a thermohygrometer is important in some places, especially in hospitals and climate room equipment. A climate chamber is an enclosed space or isolated environment, which will provide the environmental conditions of relative humidity and temperature. In accordance with the Decree of the Minister of Health of the Republic of Indonesia. Certain rooms such as rooms in hospitals require special attention to environmental conditions, such as the surgical process that occurs in the operating room. A thermohygrometer is a tool used to monitor room conditions. The thermoygrometer used must be able to trace the measurement results using certain media. A climate chamber is a device that provides the desired climate regardless of the external environment. The purpose of this study was to analyze the comparison of PID and Fuzzy Logic temperature control systems on the Climatic Chamber (Fuzzy Logic System) device which plays a role in the process of measuring room temperature and humidity in the field. The method used in this study was to compare directly with a previously calibrated thermohygrometer. The measurement results at 25°C have a response time of 7 minutes 30 seconds and an overshoot of 0.1°C, at a temperature of 30°C has a response time of 5 minutes 15 seconds and an overshoot of 0.1°C, at a temperature of 35°C has a response time of 5 minutes 30 seconds and 0.2°C overshoot. At 50%RH Humidity has a response time of 13 minutes 30 seconds, at 60%RH Humidity has a 12 minute response time, At 70%RH Humidity has a 6 minute response time. The measurement results show that fuzzy logic control has more advantages than PID control. Fuzzy logic control has a faster response time to setpoint than PID control and fuzzy logic control has smaller overshoot compared to PID control.
Comparing Temperature and Humidity Control Using PID and Fuzzy Logic in a Climatic Chamber Putra, Affan Kurnia; Rahmawati, Triana; Assalim T.P, Moch.Prastawa; Misra, Shubhrojit
Jurnal Teknokes Vol. 17 No. 2 (2024): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The presence of a thermohygrometer is important in some places, especially in hospitals and climate room equipment. A climate chamber is an enclosed space or isolated environment, which will provide the environmental conditions of relative humidity and temperature. In accordance with the Decree of the Minister of Health of the Republic of Indonesia. Certain rooms such as rooms in hospitals require special attention to environmental conditions, such as the surgical process that occurs in the operating room. A thermohygrometer is a tool used to monitor room conditions. The thermoygrometer used must be able to trace the measurement results using certain media. A climate chamber is a device that provides the desired climate regardless of the external environment. The purpose of this study was to analyze the comparison of PID and Fuzzy Logic temperature control systems on the Climatic Chamber (Fuzzy Logic System) device which plays a role in the process of measuring room temperature and humidity in the field. The method used in this study was to compare directly with a previously calibrated thermohygrometer. The measurement results at 25°C have a response time of 7 minutes 30 seconds and an overshoot of 0.1°C, at a temperature of 30°C has a response time of 5 minutes 15 seconds and an overshoot of 0.1°C, at a temperature of 35°C has a response time of 5 minutes 30 seconds and 0.2°C overshoot. At 50%RH Humidity has a response time of 13 minutes 30 seconds, at 60%RH Humidity has a 12 minute response time, At 70%RH Humidity has a 6 minute response time. The measurement results show that fuzzy logic control has more advantages than PID control. Fuzzy logic control has a faster response time to setpoint than PID control and fuzzy logic control has smaller overshoot compared to PID control.
Design Analysis of Portable 1 Channel Infusion Device Analyzer Using Sensor SKU 237545 Syaifudin, Syaifudin; Rahmawati, Triana
Jurnal Teknokes Vol. 16 No. 4 (2023): December
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

An infusion pump is a tool used to inject a certain amount of fluid into the patient's body through the patient's veins continuously over a certain period of time. A syringe pump is a tool that functions to push the syringe rod so that it can produce a flow ranging from microliters to milliliters per minute periodically with high accuracy. Very often there are problems with blockages or occlusion when using infusion pumps and syringe pumps. The occlusion limit set is ≤20 PSI according to ECRI. The presence of occlusion in the infusion pump and syringe pump can be identified when there is an alarm buzzer which will sound when a blockage is detected. A 1 Channel Portable Infusion Device Analyzer has been designed using the SKU 237545 Sensor, namely by using a 1 channel flowrate and occlusion sensor and making it portable to be efficient. For this reason, it is necessary to analyze the performance of the tools that have been created. How accurate is it? From the results of performance testing, Oclusion was corrected at 0.242 psi and 0.3 Psi. For flow rate, the largest correction was 2.4 ml/hour and the uncertainty was 6,046 ml/hour. This shows that the accuracy of the design is still quite high and the resulting tool is still not stable, this can be seen from the uncertainty value. The uncertainty that occurs is likely due to the sensitivity of the droplet sensor related to the detection time of the droplet
Improvement of Non-invasive Blood Sugar and Cholesterol Meter with IoT Technology Islamudin, Ahmad Faisal; Rahmawati, Triana; Triwiyanto, Triwiyanto; Abudlayev, Vugar
Jurnal Teknokes Vol. 17 No. 1 (2024): March
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

In checking blood sugar levels, patients often feel uncomfortable because invasive blood sampling must be done and if done to patients who have a history of high glucose, it can cause wounds that are difficult to heal and can be operated on. This study aims to non-invasively monitor cholesterol levels, reducing discomfort and pain for patients by eliminating the need for invasive procedures. The method used in this research is the MAX30102 sensor will detect blood sugar through the patient's finger, the data will be processed in ESP8266 as monitoring will connect to the OLED LCD as a viewer and IoT as data storage with WiFi connected. In this study, the greatest accuracy value was obtained 99.03% with the largest error value of 10.52% and the smallest accuracy value was 89.48% with the smallest error value of 0.97%. From all measurement results, the average accuracy value is 93.974% and the average error is 6.026%. It can be concluded that the development of a non-invasive method for monitoring blood sugar levels by utilizing the MAX30102 sensor with this accuracy value shows that this non-invasive method is reliable for monitoring blood sugar levels. In future studies, researchers are expected to use more accurate sensors and take more data to get a better average value.
Analysis of Drop Sensor Accuracy in Central Infusion Peristaltic Monitoring Based on Computer Using Wireless Communication HC-11 Syaifudin, Syaifudin; Rahmawati, Triana; Jannah, Siti Rohmatul; Gupta, Sandeep Kumar; Gopal, Ram
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 4 No. 2 (2022): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.146

Abstract

In some hospitals, the infusion is still done manually, where medical personnel observe the liquid droplets directly and then control the rate using a mechanical resistor (clamp). This method is certainly far from accurate. An infusion pump is a medical aid that functions to control and ensure the correct dose of infusion fluid given to patients treated. The purpose of this study was to analyze the accuracy of the infrared photodiode as a drop sensor based on the readings of the infusion pump monitoring system. This module consists of a photodiode infrared drop sensor module, a comparator circuit, a monostable circuit, a stepper motor, an L298N motor driver, and an ATmega328 microcontroller. The droplets were detected by an infrared photodiode sensor, then compared with a comparator and monostable circuit as an oscillator developer, and then the flow rate and residual volume readings were generated by the ATmega328 microcontroller. Next, this data has sent to the computer via the HC-11 wireless. The results of the flowrate module measurement show the highest error value of 3% at the 30 ml/hour setting and the lowest error value of 2.5% at the 60 ml/hour setting. Meanwhile, the results of the flow rate measurement using an infusion device analyzer obtained the highest error value of 4% at the setting of 30 ml/hour and 60 ml/hour, and the lowest error value of 0.8% at the setting of 100 ml/hour. Monitoring the infusion pump was designed centrally to facilitate the nurse's task in monitoring the infusion dose given to the patient accurately. Based on this research, the accuracy of the infrared sensor and photodiode is very good by looking at the existing error rate.
Monitoring the Stability of Oxygen Flow Analyzer on Oxygen Station in the Hospital Rosida, Nur Khabibatul; Rahmawati, Triana; Wisana, I Dewa Gede Hari; Nosike, Maduka
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 1 (2023): February
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i1.161

Abstract

In addition to benefits, oxygen therapy also has certain dangers and side effects. Hence, oxygen therapy must be given at the proper dose by monitoring the patient regularly and adjusting the oxygen flowmeter. The accuracy of flowmeter under standard conditions is guaranteed by manufacturer. Through time and use, the precision may change and the flow accuracy given in a hospital setting may different from the original value. Related to this matter, current research was carried out aiming to conduct further research on oxygen flow analyzer which focused on discussing the accuracy and stability of the oxygen flow sensor against the gold standard. The contribution of this study is to increase the range of oxygen flowrate measurement to 15 liters per minute (LPM). Furthermore, this research used Arduino Mega, while the gas flow sensor used was legris flow sensor. The measurement results were further displayed on TFT LCD equipped with SD Card data storage. The gas flowrate was regulated using a flowmeter (GEA). Meanwhile the comparison tools used Oxygen Analyzer and 1 m3 oxygen gas cylinder. At the testing stage, the sensor reading value on the module that appeared on the TFT LCD was compared with the resultsf a comparison tool with a measurement range of 1 LPM to 15 LPM 6 times at each point. The conclusion from these results is that the calibrator module has a relative error that is still within the allowable tolerance limit of ±10%.
Accuracy of Infrared Photodiode Sensors at The Flowrate Measurement in Infusion Device Analyzer with 2 Channel TFT Display Azizah, Wafiq Nur; Rahmawati, Triana; Syaifudin, Syaifudin
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 3 (2023): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i3.177

Abstract

Infusion is a medical procedure involving the delivery of fluids, medications, nutrients, or other substances into a patient's circulatory system through intravenous flow. In its implementation, commonly used infusion tools are infusion pumps and syringe pumps, as these devices assist in accurately and precisely controlling the flow rate. However, with continuous usage, there is a potential for inaccuracies in measuring the flow rate of fluids from these devices. Therefore, periodic calibration is necessary. According to Regulation No. 54 of 2015 from the Ministry of Health, calibration of medical devices, including infusion devices, must be conducted at least once a year to ensure their ongoing accuracy. The purpose of this research is to design an Infusion Device Analyzer (IDA) with a flow rate parameter. The contribution of this research is that the tool can accurately calculate the correct value of the flow rate that comes out of the infusion pump and syringe pump. One of the innovations resulting from this study is the Infusion Device Analyzer, equipped with a 7-inch TFT LCD screen that displays graphical parameters of the flow rate. This is achieved through the use of Infrared Photodiode sensors, which measure the rate of fluid flow. The performance graph displayed on the TFT LCD can visualize the stability of fluid flow when using various types of devices like syringe pumps and infusion pumps. The results of this research show a range of error values in the performance of various brands of infusion devices. When using the Terumo Syringe Pump, there is an error value of 0.86% (100 mL/h) for Channel 1 and 0.69% (100 mL/h) for Channel 2. For the B-Braun Syringe Pump, the error value is 1.30% (100 mL/h) for Channel 1 and 0.85% (10 mL/h) for Channel 2.
Enhancing Infusion Pump Calibration through Evaluating Occlusion Sensor Performance in a Dual-Channel Infusion Device Analyzer Asrori’, Ach Jiddan; Yulianto, Endro; Rahmawati, Triana
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 3 (2023): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i3.178

Abstract

Occlusions frequently hinder the continuous delivery of medications or fluids through syringes and infusion pumps, posing a critical challenge in medical practice. To address this issue, the infusion set occlusion threshold has been established at 20 Psi, guided by ECRI standards. Annual recalibration is essential to ensure compliance with this benchmark. This study focuses on appraising the precision of a pressure sensor integrated into a dual-channel TFT display infusion device analyzer. The innovative dual-channel design streamlines the concurrent calibration of two medical instruments, enhancing efficiency. The research employs a water pressure sensor to detect occlusions and a solenoid valve to simulate pressure conditions. Upon pressure detection, the sensor transmits data to an Arduino for processing. Results are vividly displayed on a 7-inch TFT LCD screen, providing real-time graphical and numerical insights, which are also stored on an SD card. Significant findings reveal distinct error margins across devices: 2.84% for the Terumo TE-331 Infusion Pump, 7.26% for the TOP-5300 Infusion Pump, a notable 58.20% for the TOP-3300 Infusion Pump, and a striking 71.26% for the Infusia VP7 infusion, indicative of pressure accuracy variations. Notably, the SEN0257 sensor exhibits superior precision when integrated with a syringe pump, showcasing a more favorable error rate compared to larger infusion pumps. This study's implications extend to the critical domain of infusion pump calibration, offering a valuable reference for assessing device suitability. The research contributes not only to refining infusion accuracy but also offers a practical framework for optimizing medical device performance, thus enhancing the overall quality of patient care.
A Low Cost Negative Pressure Wound Therapy Based on Arduino Fahriansyah P, Fikri; Luthfiyah, Sari; Rahmawati, Triana; Ahniar, Nur Hasanah
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 2 No. 2 (2020): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.226

Abstract

One of the causes of increasing diabetes mellitus is irregular diet, lifestyle, and exercise. This disease can cause complications, including susceptibility to infection, so that it develops into diabetic ulcers and can lead to amputations. The purpose of this study is to design a low-cost device used to treat diabetic ulcers. The contribution of this study is that the system can help remove fluid from the wound with controlled suction pressure so that it can facilitate the healing process faster. This device is called as negative pressure wound therapy (NPWT) device, which works based on negative pressure from the vacuum motor by utilizing MPXV4115VC6U and MPXV5050VC6T1 pressure sensors at a pressure limit of 0 to -350 mmHg. Arduino microcontroller was used to process the data from the sensor. Further, the process data will then be displayed on the liquid crystal display (LCD) for user communication. The MPX4115VC6U sensor produces a pressure of -55.97 mmHg when setting -50 mmHg, and the resulting output is 3.32 volts, while the MPXV5050VC6T1 sensor produces a pressure of 51.18 mmHg at a setting of 50 mmHg. The resulting output is 3.18 volts; from the above data, it can be seen that the MPX5050VC6TI sensor has a smaller error.
An Improved Power Management System in Electrosurgery Unit Monopolar Design Domigata, Riga; Indrato, Tri Bowo; Rahmawati, Triana; Sanajit, Narongrit
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 2 No. 2 (2020): August
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v2i2.231

Abstract

In using the Electrosurgery unit, improper power settings and modes can cause tissue damage, so it is necessary to adjust the cutting mode and power settings needed. The purpose of this research is to design power control and cutting mode in Electrosurgery using Arduino nano as a regulator of power and pulse or duty cycle. The contribution of this research is the creation of power control and mode in the Electrosurgery unit to increase power and cutting mode. This is to control the electrosurgery power. The LM2907 IC frequency to voltage circuit is used as a voltage regulator, which is issued according to the frequency with the power selection LOW, MEDIUM, HIGH. The method used is the CMOS 4069 device as a frequency generator at 250 kHz, then the driver pulse is passed and controlled by the ATmega328 IC, then forwarded to an inverter circuit that functions to increase the voltage and output in the form of power. After the measurement process is carried out on the inverter input with a Blend mode three value, the voltage value is obtained at the low setting 100 V error 0.03%, medium setting 110V error 0.02%, High setting 120 V Error -0.02%. While the measurement results in the coagulation mode are the low setting error of 100 V 0.05%, the medium setting error is 110V 0.08%. High setting error is 130 V 0.003%. The measurements show that the error in power management is lower than 1%. The results of this study can be implemented in the electrosurgery unit to reduce tissue damage due to a lack of cutting modes and power management
Co-Authors Abdi Wibowo Abdul Kholiq Abdulhamid, Mohanad Abdullayev, Vugar Abdussalam Ali Ahmed Abudlayev, Vugar Ach Jiddan Asrori' Ahmad Zuber Ahmad Zuber Ahniar, Nur Hasanah Akbar, Rezza Dian Andri Firmansyah Anisa Rahma Astuti Aris Arif Mundayat Asrori’, Ach Jiddan Assalim T.P, M. Prastawa Assalim T.P, Moch.Prastawa Azizah, Wafiq Nur Bambang Guruh Irianto Dhany Alvianto Wibaksono Domigata, Riga Effieta Alfi Wulandari Egan Graha Utama Endro Yulianto Fahriansyah P, Fikri Faiz Nafi'u Pradana, Much Farooq Mujahid, Muhammad Umer Fikri Fahriansyah Pramono Fita Florensa Rooswita Fitri Ayu Handayani Fitriyana Jayanti Ghina Reftantia Gopal, Ram Gunawan Gunawan Gupta, Sandeep Kumar Hamzah, Torib Handayani, Fitri Ayu Hapsari, Yuanita Dwi Harisha Avin Nurcahyana Hendris Hendris, Hendris Heru Purnomo Honey Honey I Dewa Gede H.W I Dewa Gede Hari Wisana I Putu Anna Andika Indrato, Tri Bowo Indrato, Tri Bowo Islamudin, Ahmad Faisal Jannah, Siti Rohmatul Khongdet Phasinam Kinanti Elok Putri Lamidi, Lamidi Liliek Soetjiatie Lisa choirunnanda Luh Putu Ratna Sundari Luthfiyah, Sari M. Ridha Mak’ruf Maduka Nosike Mahardika, I Kadek Eman Giyana Mahendra, Farhel Gading Mansour Asghari Masood, Faraz Mifthahul Maghfiroh, Anita Misra, Shubhrojit Mohanad Abdulhamid Muflih Ridwan, Muhamad Muhammad Ridha Mak'ruf Muhammad Roni Setiawan Mundayat, Aris Arif Narongrit Sanajit Nosike, Maduka Nur Khabibatul Rosida Pawana, I Putu Alit Penggalih Mahardika Herlambang Priyambada Cahya N Priyambada Cahya Nugraha Putra, Affan Kurnia Putri, Rizqa Febriliany Ram Gopal Ramandani, Rifan Rezza Dian Akbar Ridho Armi Nabawi Riga Domigata Romadhini, Novita Nur Azize Rosida, Nur Khabibatul Sanajit, Narongrit Sandeep Kumar Gupta Setiawan, Muhammad Roni Siti Rohmatul Jannah Suryadinata, Theofilus Apolinaris Syaifudin Syaifudin Syaifudin Syaifudin Syaifudin, Syaifudin Theofilus Apolinaris Suyadinata Torib Hamzah Tri bowo Indrato Tri Bowo Indrato Triwiyanto Triwiyanto Utama, Egan Graha Utomo, Bedjo Veriko Yonanto Vugar Abdullayev Wafiq Nur Azizah Wahyu Caesarendra Wulandari, Effieta Alfi Yulia Ningrum, Churie Nurhaeni