Claim Missing Document
Check
Articles

PENGUJIAN TEGANGAN TEMBUS BOLAK BALIK PADA BAHAN ISOLASI MINYAK JARAK SEBAGAI ALTERNATIF MINYAK TRANSFORMATOR Syarifasa, Arkananta; Dhofir, Moch.; Utomo, Teguh
Jurnal Mahasiswa TEUB Vol. 12 No. 4 (2024)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The use of vegetable oil, especially castor oil as liquid insulation, needs to be proven by testing the breakdown voltage anddielectric strength of the oil as liquid insulation to predetermined standards. The test is to determine the breakdown voltageresistance and suitability of castor oil as an alternative liquid insulation for transformer oil in accordance with SPLN (StateElectricity Company Standards) and IEC (International Electrotechnical Commission) standards. The research method in thisstudy is analysis and direct measurement of the variables tested, namely the effect of heating with temperature variations on the breakdown voltage of castor oil. Testing of heating temperature variations on oil shows that there is an increase in the breakdown voltage value of castor oil after being given a directly proportional variation in heating temperature and experiencing a quite significant increase in breakdown voltage.  Keywordrs : Castor oil, Breakdown Voltage, Moisture Content, Permittivity, Conductivity
ANALISIS KARAKTERISTIK BEBAN DAN TINGKAT KONSUMSI ENERGI LISTRIK PADA GEDUNG A, B, E, F, FAKULTAS ILMU ADMINISTRASI UNIVERSITAS BRAWIJAYA ‘Aqila, M. Farrel Nikkola Putra; Dhofir, Moch.; Utomo, Teguh
Jurnal Mahasiswa TEUB Vol. 13 No. 1 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Keseimbangan antara konsumsi dengan pasokan energi listrik merupakan hal yang perlu dipertimbangkan konsumen. Pasalnya, permasalahan yang sering terjadi adalah ketidaksesuaian penyediaan energi dengan  kebutuhan energi listrik sehingga konsumen harus mengeluarkan biaya  yang lebih besar. Maka dari itu, diperlukan analisis karakteristrik beban listrik dan keseimbangan konsumsi dengan pasokan energi listrik. Pada penelitian ini dipilih Fakultas Ilmu Administrasi Universitas Brawijaya (FIA UB) sebagai objek pengujian untuk mewakili fakultas non-eksakta. Penelitian ini bertujuan untuk mendapatkan karakteristik beban listrik serta penggunaan energi listrik sehingga dapat menjadi acuan dan evaluasi sistem kelistrikan di FIA UB. Metode yang digunakan berupa pengukuran secara langsung selama 7 hari (Senin-Minggu) dengan interval waktu 10 menit menggunakan Power Analyzer LUTRON DW 6092 di sisi Incoming LVMDP 555kVA. Data pengukuran yang akan dianalisis yaitu, data tegangan, arus, daya aktif, daya semu, dan energi. Berdasarkan hasil analisis data tersebut, didapatkan bahwa rata – rata penggunaan beban tertinggi terjadi di hari Senin sebesar 66,85 KWdan relatif menurun mencapai 19,9 KW di hari Minggu. Ketidakseimbangan tegangan dan fluktuasi tegangan selama satu minggu sudah optimal dan sesuai dengan standar IEEE No.446-1995 (<2,5%) dan SPLN No. 1 Tahun 1995. Lalu untuk ketidakseimbangan arus beban selama satu minggu dikategorikan sebagai ”cukup” berdasarkan SPLN No. 17 Tahun 2014. Penggunaan energi listrik di FIA UB sudah terkategori hemat energi dengan nilai Intensitas Konsumsi Energi (IKE) sebesar 17,55 kWH/m²/tahun, tetapi penggunaan terhadap pasokan daya dari PLN masih tidak seimbang yaitu hanya 35,53% dan juga presentase pembebanan trafo yang hanya 19,72% dari kapasitas nominal trafo. Kata kunci: Karakteristik beban listrik, Keseimbangan, Metode pengukuran, FIA UB, IKE
Analisis Penambahan Recloser Untuk Meningkatkan Keandalan Sistem Distribusi 20 kV pada Penyulang Ratulangi PT. PLN (Persero) ULP Ngadiluwih Kurniawan, Ananda Donny; Wijono, n/a; Utomo, Teguh
Jurnal Mahasiswa TEUB Vol. 13 No. 2 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem distribusi daya listrik di PT. PLN (Persero) ULP Ngadiluwih berperan dalam menyalurkan energi listrik dari gardu induk hingga ke pelanggan. Keandalan sistem distribusi menjadi suatu hal yang penting untuk pelanggan. Penelitian ini bertujuan untuk menganalisis penambahan recloser pada jaringan distribusi 20 kV Penyulang Ratulangi PT. PLN (Persero) ULP Ngadiluwih, dan menganalisis keandalan sistem distribusi tersebut sebelum dan setelah penambahan recloser. Analisis penambahan recloser dilakukan dengan perhitungan indeks keandalan menggunakan metode FMEA (Failure Mode Effect Analysis), simulasi sebelum dan setelah penambahan recloser menggunakan software ETAP 19.0.1. Selanjutnya dibandingkan dengan ketetapan SPLN 59 Tahun 1985. Hasil perhitungan indeks keandalan metode FMEA diperoleh nilai SAIFI sebesar 1,7236 kali/pelanggan/tahun, SAIDI sebesar 5,4088 jam/pelanggan/tahun, dan CAIDI sebesar 3,128563 jam/kali. Hasil simulasi ETAP sebelum penambahan recloser diperoleh nilai SAIFI sebesar 1,8134 kali/pelanggan/tahun, SAIDIsebesar 5,4295 jam/pelanggan/tahun dan CAIDI sebesar 2,994 jam/kali. Penempatan titik recloser memiliki pengaruh terhadap nilai keandalan sistem, dimana skenario 2 menjadi titik penempatan recloser yang paling optimal. Hasil simulasi ETAP setelah penambahan recloser pada skenario 2 diperoleh nilai SAIFI sebesar 1,4572 kali/pelanggan/tahun, SAIDI sebesar 5,2113 jam/pelanggan/tahun dan CAIDI sebesar 3,576 jam/kali. Berdasarkan hasil nilai indeks keandalan metode FMEA, simulasi ETAP sebelum dan setelah penambahan recloser memiliki nilai yang lebih rendah dibandingkan dengan nilai SPLN 59 Tahun 1985. Dengan demikian, sistem distribusi pada Penyulang Ratulangi PT. PLN ULP Ngadiluwih telah memenuhi standar dan dapat dinyatakan andal. Kata Kunci : Indeks Keandalan, Penambahan Recloser, Metode FMEA, ETAP.
ANALISIS KEANDALAN SISTEM DISTRIBUSI 20 KV PENYULANG SUDAN PT. PLN ULP SUKOREJO MENGGUNAKAN METODE RELIABILITY INDEX ASSESSMENT Maulana, Achmad Fazar Arya; Utomo, Teguh; Nusantoro, Goegoes Dwi
Jurnal Mahasiswa TEUB Vol. 13 No. 2 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini membahas analisis keandalan sistem distribusi 20 kV  Penyulang Sudan PT. PLN ULP Sukorejo. Indeks yang digunakan untuk  mengukur keandalan sistem distribusi adalah SAIFI (System Average  Interruption Frequency Index), SAIDI (System Average Interruption  Duration Index), dan CAIDI (Customer Average Interruption Duration  Index). Tujuan dari penelitian ini adalah memperoleh nilai indeks  keandalan Penyulang Sudan dengan metode Reliability Index Assessment  (RIA) dan simulasi single line diagram pada ETAP serta  membandingkannya dengan standar SPLN 59 Tahun 1985. Metode  penelitian ini melibatkan perhitungan indeks keandalan serta simulasi menggunakan software ETAP 19.0.1. Hasil penelitian menunjukkan bahwa  nilai indeks keandalan metode RIA untuk SAIFI sebesar 4,8420 gangguan  per tahun , SAIDI sebesar 11,8259 jam per tahun , dan CAIDI sebesar 2,4423 jam per gangguan. Sedangkan hasil simulasi ETAP menunjukkan nilai SAIFI  sebesar 4,8789 gangguan per tahun , SAIDI sebesar 11,8851 jam per tahun, dan CAIDI sebesar 2,4360 jam per gangguan. Berdasarkan perbandingan  dengan SPLN 59 Tahun 1985, sistem distribusi Penyulang Sudan belum  dapat dikatakan handal, karena nilai SAIDI dan CAIDI masih di bawah  ketetapan SPLN NO. 59 Tahun 1985 , tetapi pada nilai SAIFI diatas  ketetapan SPLN 59 Tahun1985.Kata Kunci ̶ Penyulang Sudan, indeks keandalan, metode RIA,ETAP, SPLN 59 Tahun 1985.
Pengaruh Pemasangan Sistem PLTS On-Grid Terhadap Pencapaian Carbon Neutral pada Kantor Bank BRI Cabang Soehat Malang Rachendra, Bima Denatta; Utomo, Teguh; Wibawa, Unggul
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini bertujuan untuk menganalisiskelayakan teknis, ekonomi, dan lingkungan dari penerapan sistemPembangkit Listrik Tenaga Surya (PLTS) on-grid di Kantor BankBRI Cabang Soehat Malang dalam mendukung pencapaian targetcarbon neutral. Pengumpulan data dilakukan melalui observasilangsung dan wawancara, serta didukung oleh data sekunderseperti intensitas radiasi matahari dan suhu lingkungan. Simulasisistem dilakukan menggunakan perangkat lunak PVsyst untukmenentukan konfigurasi optimal serta estimasi produksi energitahunan dan performance ratio (PR). Hasil simulasi menunjukkanbahwa sistem PLTS berkapasitas 26,4 kWp dengan 48 unit modulTrina Solar TSM-DEG19C.20 dan inverter Growatt MID25KTL3-X mampu menghasilkan 41.899 kWh per tahun denganPR rata-rata sebesar 84,8%. Secara ekonomi, proyek ini layakdilaksanakan dengan NPV sebesar Rp204.307.651, IRR sebesar13,73%, Payback Period selama 6,6 tahun, dan Cost of Energy(CoE) sebesar Rp503,94/kWh, yang lebih rendah dari tarif listrikPLN. Dari aspek lingkungan, sistem ini mampu mereduksi emisikarbon sebesar 916,13 ton CO₂ selama 30 tahun masa operasional.Berdasarkan hasil tersebut, pemasangan sistem PLTS on-gridterbukti layak secara teknis, ekonomis, dan ramah lingkungan,serta berkontribusi pada pengurangan emisi karbon di sektorperkantoran.Kata Kunci ̶ PLTS on-grid, carbon neutral, analisis teknis,analisis ekonomi, emisi karbon.
Analisis Perbaikan Rugi Daya 20 kV dengan Penambahan Kapasitor Bank di Gardu Induk Banaran 2 PT. PLN (Persero) ULP Ngadiluwih Priambudi, Ardhito; Utomo, Teguh; Wijono, n/a
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Gardu Induk Banaran 2 berperan sebagai sumberutama distribusi listrik dengan tegangan 150 kV yang kemudianditurunkan menjadi 20 kV sebelum disalurkan ke masing-masingpenyulang. Penyulang Ngadiluwih merupakan penyulang yangmengalami penurunan tegangan (voltage drop) yang palingsignifikan, yakni rata-rata sebesar 6,48% dengan nilai jatuhtegangan terbesar mencapai 1,84 kV, yang berarti melebihi batastoleransi penurunan tegangan maksimal yaitu ±5% sebagaimanaditetapkan dalam Peraturan Menteri ESDM No. 4 Tahun 2009. Inimenunjukkan bahwa penyulang tersebut tidak memenuhi standaroperasional dan perlu dilakukan tindakan korektif. Berdasarkanperhitungan nilai Loss Sensitivity Factor (LSF) dan norm, dipilihbeberapa bus prioritas dengan kombinasi nilai LSF tinggi dantegangan yang mendekati atau sedikit melebihi batas atas standar.Setelah dilakukan perhitungan kompensasi daya reaktif (Qc) yangdibutuhkan agar setiap bus mencapai faktor daya ideal 0,9,dilakukan injeksi kapasitor bank secara selektif. Contohperhitungan menunjukkan bahwa pada BUS 175 NGD, dibutuhkaninjeksi daya reaktif sebesar 113 kVAR untuk meningkatkan faktordaya ke angka yang diinginkan. Setelah injeksi kapasitor bank,terjadi penurunan signifikan pada nilai rugi daya reaktif dantegangan jatuh. Rata-rata penurunan tegangan menjadi sekitar 2%,dan nilai maksimum turun sebesar 1,336 kV, yang berarti telahmemenuhi standar ESDM. Selain itu, terjadi penurunan total rugidaya sistem sebesar 100,0447 kVAR dan 156,3443 kW menunjukkanefisiensi sistem yang lebih baik dan penghematan energi secaranyata.Kata Kunci—Rugi Daya, Kapasitor Bank, Jatuh Tegangan, LossSensitivity Factor (LSF), ETAP.
Penentuan Penempatan dan Kapasitas Kapasitor Bank pada Saluran Udara Tegangan Menengah 20kV di Gardu Induk Alta Prima Penyulang SSG2 UP3 Surabaya Barat Khurun ‘Ain, n/a; Utomo, Teguh; Nusantoro, Goegoes Dwi
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pertumbuhan aktivitas ekonomi di Surabayamendorong peningkatan terhadap konsumsi energi Listrik PT. PLN(Persero). Untuk memenuhi kebutuhan tersebut, maka dibutuhkansistem tenaga listrik yang memadai. Maka, pada penelitian inidilakukan pemasangan kapasitor bank untuk meningkatkanefisiensi sistem melalui simulasi aliran daya berbasis metodeNewton-Raphson pada perangkat lunak ETAP. Lokasi penempatankapasitor ditentukan berdasarkan analisis sensitivitas rugi-rugi danperhitungan kapasitas kapasitor bank dihitung menggunakanperhitungan selisih daya reaktif.Dari tiga penyulang yang terhubung pada GI Alta Prima,penyulang SSG2 tercatat memiliki jatuh tegangan tertinggi yaitusebesar 8,855%. Hasil simulasi dengan pemasangan kapasitor bankmenunjukkan bahwa kondisi 4 merupakan kondisi yang paling baikdiantara kondisi lainnya. Penambahan kapasitor bank berdampakpada penurunan nilai jatuh tegangan dan rugi daya. namun padakondisi 6 penurunan nilai jatuh tegangan dan rugi daya sangat keciljika dibandingkan dengan kondisi lain dan kondisi sebelumpemasangan kapasitor bank. Hal ini dikarenakan pemasangankapasitor bank langsung dipasang pada bus dengan nilai jatuhtegangan tertinggi dan tidak mempertimbangkan perhitungansensitivitas rugi-rugi.Kata Kunci ̶ Kapasitor Bank, Jatuh Tegangan, Sensitivitas Rugirugi, ETAP.
RELIABILITY ANALYSIS OF THE 20 KV DISTRIBUTION NETWORK SYSTEM OF THE JIKEN FEEDER AT PT PLN (PERSERO) ULP PORONG USING FAILURE MODE ANDEFFECT ANALYSIS (FMEA) METHOD Zuhdi, Fadhil Ariq; Utomo, Teguh; Hasanah, Rini Nur
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak - Pada umumnya tenaga Listrik hasilkan daripembangkit, ditransmisikan ke gardu induk laludidistribusikan menuju pelanggan.PT. PLN (Persero) ULPPorong merupakan salah satu sub-unit dari UP3 Sidoarjoyang berhubungan langsung kepada para pelanggan sertamemperbaiki gangguan pada lingkup tersebut. Keandalansuatu sistem distribusi 20 kV dapat dianalisis denganperhitungan untuk mencari SAIFI, SAIDI, dan CAIDI. Salahsatu analisis yang dapat dilakukan adalah denganmenggunakan metode Failure Mode and Effect Analysis(FMEA). Metode ini dilakukan dengan cara mengidentifikasikegagalan pada komponen yang terdapat pada sistempenyulang. Parameter indeks keandalan adalah lajukegagalan SPLN, panjang saluran, laju kegagalan tiapperalatan, waktu perbaikan, laju perbaikan, dan jumlangpelanggan pada setiap gardu distribusi. Analisis keandalanjuga dapat dilakukan menggunakan software ETAP 19.0.1dengan beberapa parameter seperti panjang saluran antarperalatan, jumlah pelanggan tiap titik beban, switching time,active failure rate. Selain itu, dengan mengidentifikasigangguan yang terjadi dapat menghasilkan nilai kerugianaekonomis yang diterima oleh PT. PLN (Persero) ULP Porongpada penyulang jiken. Kemudian, hasil analisis indekskeandalan dari perhitungan manual dan denganmenggunakan software ETAP 19.0.1 di PT. PLN (Persero)ULP Porong pada penyulang jiken yang menunjukan nilai dibawah SPLN No. 59 Tahun 1985.Kata kunci: Distribusi Listrik, FMEA, ETAP, IndeksKeandalan, Kerugian Ekonomis
PENGUJIAN DISSOLVED GAS ANALYSIS METODE ROGER’S RATIO, DUVAL’S TRIANGLE, LOW ENERGY DEGRADATION TRIANGLE, DANDUVAL’S PENTAGON TERHADAP KEGAGALAN TRANSFORMATOR DAYA PADA PT. PERTAMINA RU V BALIKPAPAN Muyassar, Tegar; Utomo, Teguh; Dhofir, Moch.
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Transformator daya merupakan salah satu peralatanutama dalam sistem tenaga listrik. Diantara bagian penting daritransformator daya yaitu minyak transformator yangmerupakan sistem isolasinya. Maka dari itu, perlu dilakukandiagnosis dengan tujuan untuk mengidentifikasi penyebabadanya kegagalan pada transformator. Metode yang digunakanuntuk melakukan diagnosis terhadap minyak transformatortersebut adalah Dissolved Gas Analysis (DGA) yaitu metodeRoger’s Ratio, Duval’s Triangle, Low Energy DegradationTriangle, dan Duval’s Pentagon. Pengujian ini dilakukan padatransformator daya (P-30-TR61C) pada substation 61 (SS 61) diPT. Pertamina RU V Balikpapan. Pengujian menggunakan 2sampel yang diambil pada waktu yang berbeda. Hasil analisisdidapatkan adanya indikasi kegagalan berupa discharges of lowenergy atau peluahan energi rendah dan thermal fault ataukegagalan termal pada transformator. Hal tersebut dapatmenyebabkan rusaknya isolasi padat (selulosa) akibat terjadipeluahan dan kenaikan suhu. Apabila tidak dilakukan tindakanperbaikan atau pemeliharan secara berkala, transformator dapatmengalami penurunan kinerja dan kegagalan dalam skala yanglebih besar.Kata Kunci: Transformator, Minyak Isolasi, DGA, Roger’s Ratio,Duval’s Triangle, Low Energy Degradation Triangle, Duval’sPentagon.
Pengujian Dissolved Gas Analysis (DGA) dengan Empat Metode Berbeda Pada Transformator Daya di PT. Pertamina RU V Balikpapan Maulidina, Nabila Vida; Utomo, Teguh; Wibawa, Unggul
Jurnal Mahasiswa TEUB Vol. 13 No. 3 (2025)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Transformator daya merupakan komponen vitaldalam sistem kelistrikan industri, khususnya di sektorpengolahan minyak seperti PT. Pertamina RU V Balikpapan.Untuk memastikan keandalan operasional, diperlukan metodediagnosis yang akurat guna mendeteksi potensi kerusakaninternal secara dini. Penelitian ini bertujuan untukmenganalisis kondisi transformator daya berdasarkan hasilpengujian Dissolved Gas Analysis (DGA) menggunakan empatmetode analisis, yaitu Total Dissolved Combustible Gas (TDCG),Key Gas (KG), Rasio IEC, dan Four Gases Square (FGS).Penelitian ini dilakukan pada transformator daya (P-30-TR61C) pada substation 61 (SS 61) di PT. Pertamina RU VBalikpapan. Data gas terlarut diperoleh dari hasil ujilaboratorium terhadap sampel minyak isolasi transformator.Hasil analisis menunjukkan adanya indikasi kegagalan arcingin oil, overheated cellulose, discharges, dan kegagalan termal.Berdasarkan analisis yang telah dilakukan, didapatkanindikasi-indikasi kegagalan transformator yang terjadi,sehingga perlu dilakukan tindakan pemeliharaan sepertimemaksimalkan sistem pendingin transformator daya,memeriksa sistem grounding, dan melakukan pengujian PowerPartial Discharge (PowerPD) Akustik. Hasil penelitian inidiharapkan menjadi acuan dalam pemeliharaan prediktiftransformator daya guna meningkatkan keandalan danefisiensi sistem kelistrikan di PT Pertamina RU V Balikpapan.Kata Kunci — Transformator, Dissolved Gas Analysis(DGA), Total Dissolved Combustible Gas (TDCG), Key Gas(KG), Rasio IEC, Four Gases Square (FGS).
Co-Authors Adi Nugroho Pamungkas Aditya Prayoga Agus Supriono Akbar, Muhammad Yoga Rochmanu Akhmad Hasim Aldo Harry Saputra Allaam, Hisyam Ghozi Altajim, Fauzan Aiman Amanda Octavianus Rizky Andreas Parningotan S. Anggie Alvionita Anwi Kusuma Ardi Moh. Yusuf Arief Y., Primanda Arifin, Muhammad Rifat Aji Satria Arizky Erwinsyah Hariyanto Arkan Pradipta Arsy Rahmat Syahbani Assariy, Muhammad Faiz Asyhari, Ahmad Rizky At Tamimi, Riswandha Yusuf Aulia, Fitrah Baskara Heka Syahputra Bernadine, Muhammad Zaidan Bhawiko, Alekhin Muhammad Azhar Candra Mebby Oka Dedy Alfilianto Derry Putranugraha Dhofir, Mochammad Dikma Hartanjung Ditto Adi Permana Dwiky Satrio Wibowo Edi Setiawan Egavania Zerlinda Elisa Gumelar Dennis Erdyan Setyo W. Erlangga Dinda Permana Erlinda Indrayani Faishal, Luthfi Nur Fakhruddin Ar Rozi Farid Rohmadi Fariz Aulia Rifqi Farraz, Dayrry Yozza Febriananda Mulya Pratama Fery Praditama Fikri, Al Hadi Fikri, Zakkiyul Firdausi, Mega Firly Azka Nurhidayah Friska Bakti Novella Gagah Pratama Putra Galih Fajar Wicaksono Gathot Winarso, Gathot Gede Teguh Adi Wedangga Gitawan Dimas Prakoso Goegoes Dwi Nusantoro Haidar Ali Yafie Hamaris, Farhan Hari Santoso Harry Soekotjo Dachlan Hery Purnomo Himam, Fanisha Laila I Kadek Dwika Antara I Wayan Ari Mahendra Ifah Dea Hapsyari Ilham Ismail Mochsen ILYAS FATIH RAMADHAN Irfan Madani Pratama Jagad, Mohammad Wahyu Jayadiyuda, I Wayan Angga Jiwandono, Ferdian Ade Kalvin Lentino Kemal Pasha Pramudianto Khurun ‘Ain, n/a Kresna Sukma Dewangga Kurniawan, Ananda Donny Laksono, Mico Norman Lavelia Permata C. Lintang Gadis Ratu Rachellya Lukmanul Hakim Lunde Ardhenta Luthfan Bagus Saputra M. Iqbal Bayhaqi Fauzi M. Yudistya Perdana Ma'arif, Muhammad Thoriqul Maharani, Bella Fathia Mahfudz Shidiq Mahfudz Sidiq Malamansyah, Triamelia Salsabila Markus D. Letik Maulana, Achmad Fazar Arya Maulidina, Nabila Vida Moch Dhofir Moch. Dhofir Moch. Dhofir Moch. Dhofir Moch. Rizki Indra Dwijayanto Mochammad Fattah, Mochammad Mohammad Fahririjal Mubarok, M. Farid Ibnu Muhamad Alif Fatur Rahman Muhamad Andre Agesa Muhammad Arsyad Muhammad Azka Athallah Muhammad Edwinsyah Redho Muhammad Fadhli Dzil Ikram Muhammad Fahmy Madjid Muhammad Faris Hizrian Muhammad Halim Sa’id Muhammad Rif’at Nor Imami Muhammad Sekti Yolansyah Muhammad Wildan D. Muhammad Zakkiyul Fikri Syahara Arifianto Muyassar, Tegar n/a Rizaq n/a Soemarwanto n/a Soeprapto n/a Suyono Nandha Pamadya Putra Nizar Shodiq Novan Ardita Pratama Nur Laili Mufarikha Nurumar Setiyo Agung Pangeran Fatullah Panji Bintang Pamungkas Pradhana, Raka Radithya Praditama, Fery Pramudya, Lembat Aji Pratama, Muhammad Pashya Rifky Priambudi, Ardhito Pudji Purwanti Pujo Utomo Putra Adi Dharma Utama Putra, Deni Dwi Rahman Rachendra, Bima Denatta Rachman Shandy Pratama Radian Hepta Martha Hardaka Rafi Ilham Rahardjo, Muhammad Farid Ramdhony Tofano Murisom Revo Chanavi Mara Rexano B, Leonardo Reza Aliansyah Rif'an, Mochammad Rini Nur Hasanah Rini Nur Hasanah Riswandha Yusuf At Tamimi Rizal Firmansyah Rizki Adhi Priawan Rizki Ashadi Rizky Hamid Robbyansyah Rohmadi, Farid Rohman, Deny Fatkhur Rosyid, Muhammad Ruditta Devianti Sambodo Rila Priambudi Saputra, Didit Sugeng Sari Yuniarti Satrio Wicaksono Sean Yudha Yahya Shiddiq, Muhammad Fatihul Shidqi, Fahruddin Siagian, Alfandri Sinta Pratiwi Soeprapto Soeprapto Suwarno, Nastiti Viononny Suyono, Hadi Syarifasa, Arkananta Sydney, Agnes Amadea Rullynda Timbul Mulia Titis Aridanti Pratiwi Tri Nurwati Try Brojoseto Alkotsar Unggul Wibawa Unggul Wibawa Unggul Wibawa Unggul Wibawa Unggul Wibawa Utomo, Muhamad Adib Nur Utomo, Muhamad Afiq Nur Wahyu Nur Firdausy Warda Islamiyah Wardani, Alya Kusuma Wijono, n/a Wilda Faradina Wisam Abyadha Ibrahim Wisnu Adi Suryo Yanuar Alfa Tri Susanto Yashinta Carolina Dewi Yuda Wastu Yudistira Adi Nugroho Yuka, Helmi Dwi Yulistiono, Irwan Zaidane Alizzah Noufal Zuhdi, Fadhil Ariq Zulfikar Subagio ‘Aqila, M. Farrel Nikkola Putra