Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Journal of Electrical Engineering and Computer (JEECOM)

Implementation of The Behaviorally Anchored Rating Scale Method for Employee Performance Evaluation of MSMEs in Surabaya City Based on Information Technology Darmanto, Darmanto; Dhaniswara, Erwin -; Widianto, Yonatan
Journal of Electrical Engineering and Computer (JEECOM) Vol 7, No 2 (2025)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v7i2.12587

Abstract

Micro, Small, and Medium Enterprises (MSMEs) in Surabaya encounter persistent challenges in conducting objective evaluations of employee performance. To address this issue, the present study introduces the application of the Behaviorally Anchored Rating Scale (BARS), employing both qualitative and quantitative approaches supported by Information Technology (IT). BARS enables performance appraisal based on specific and observable work behaviors, thereby mitigating subjectivity and enhancing the fairness of evaluations. The integration of IT further streamlines data collection processes while reducing administrative complexity. In this study, an open-source web-based application was developed and customized to align with the operational requirements of MSMEs. The primary objective is to design and implement a performance evaluation system grounded in BARS and IT, supporting MSMEs in the formulation of realistic performance benchmarks and more effective human resource management practices. The research methodology adopts the ADDIE Research and Development model, encompassing the phases of analysis, design, development, implementation, and evaluation. System reliability was assessed through black box testing, with results indicating validity and consistency across all scenarios. The findings confirm the successful deployment of a multi-user web application capability in facilitating efficient, accurate, and systematic employee performance evaluations within MSMEs
Android-Based Monitoring of 110 Volt DC System in Substations within PLN UIT JBM Region to Improve Maintenance Efficiency Dhaniswara, Erwin; Nurholis, Nurholis; Tamaji, Tamaji
Journal of Electrical Engineering and Computer (JEECOM) Vol 7, No 2 (2025)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/jeecom.v7i2.12674

Abstract

The DC 110 Volt system is a critical component in substations, serving to support the operation of control and protection devices. Instability in voltage or current within this system can result in serious failures in overall substation performance. Therefore, “Monitoring of the DC 110 Volt System in Substations within PLN UIT JBM Region Based on Android to Improve Maintenance Efficiency” in real time becomes crucial. This research aims to design and implement an Android-based monitoring system supported by Internet of Things (IoT) technology using the Blynk application. The main parameters monitored in the DC system are total DC voltage (positive and negative) within a range of 80–125 VDC and current within a range of 0–100 A, integrated with a microcontroller that transmits data to the Android application via data communication protocols. The data received by the application can be analyzed in real time, providing critical information regarding parameter deviations from operational standards. In addition, the system is equipped with an early warning feature that enables technicians to respond to potential disturbances before they affect substation operations. Based on sampling inspections of the DC system conducted by five personnel at five substations within the PLN UIT JBM region, the results show that using the DC monitoring system is more effective than manual measurements, with a time difference of 10–15 minutes. This demonstrates that the system can improve monitoring efficiency and reduce operational risks in substations. With the application of this technology, disturbances in the DC system can be detected earlier, allowing preventive actions to be carried out quickly and accurately.
Co-Authors Agus Junaidi AGUS PRAYITNO Agus Prayitno Almira Ulimaz Andy Rachman Arifin, Buatanol Arifudin, Opan Asri Ady Bakri Benny Novico Zani Boby Hendro Wardono cahyono, didik Caroline Caroline Chaterina Yeni Susilaningsih Dadang Muhammad Hasyim Darmanto Darmanto Darmanto Darwis, Akbar Darwis Dedi Gunawan Saputra Dewi, Grace Levina Didik Cahyono dwi taufik hidayat Edita Revine Siahaan Eka Selvi Handayani, Eka Selvi Encep Sopandi, Encep Erda, Roza Esther Irawati Setiawan Farid Budianto Putra Feri Sanjaya Geofakta Razali Handry Eldo Hasnia Ahmad Hidayat, Aji Atha hidayat, dwi taufik Iin Nurul Inayah Juwairiah Juwairiah Karsim Karsim Kurniawan Budhi , Robby Leonardus Setia Budi Wibowo Luthfie Lufthansa Marlina Marlina Mayestino, Alexander Machicky Melvie Paramitha Mikhael Setiawan Muhammad Subhan Iswahyudi Muhammad Syafral Muhammad Wahyudi Nazaruddin Ahmad Nining Andriani Nur Kurniasari Nuraisyah Annas, Annisa Nurholis Nurholis, Nurholis Nurwahyu Satrya, Indra Ocktavi Rizky, Ricky Oktafian Farhan Permana, Ika Dian Putra Putra Ramadhan, Mohammad Bangkit Rissa Megavitry Robby Kurniawan Budhi Rukhmana, Trisna Rukiyanto Rukiyanto, Rukiyanto Setiono, Kevin Sitti Hasnah Soegiarto, Ita Solehuddin, Moh. Sri Wiwoho Mudjanarko, Sri Wiwoho Sri Yulianto St Rahmah Subagiyo Subagiyo Suluh Sri Wahyuningsih Sundari, Sri Talakua, Eddy Lybrech Tamaji, Tamaji Widianto Yonatan, Widianto Xu, Shanshan Yoga Alif Kurnia Utama, Yoga Alif Kurnia Yosi Kristian Yulius Hari Yunaspi, Didi Zhang Wei Zulaekah Zulaekah Zulfiah Larisu