p-Index From 2021 - 2026
10.04
P-Index
This Author published in this journals
All Journal International Journal of Applied Power Engineering (IJAPE) International Journal of Advances in Applied Sciences ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika JURNAL NASIONAL TEKNIK ELEKTRO Jurnal Ilmiah KOMPUTASI CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro RELE: Rekayasa Elektrikal dan Energi Jurnal Teknik Elektro ORBITA: Jurnal Pendidikan dan Ilmu Fisika CYCLOTRON METHODIKA: Jurnal Teknik Informatika dan Sistem Informasi Jurdimas (Jurnal Pengabdian Kepada Masyarakat) Royal TELKA - Telekomunikasi, Elektronika, Komputasi dan Kontrol JOISIE (Journal Of Information Systems And Informatics Engineering) Sang Pencerah: Jurnal Ilmiah Universitas Muhammadiyah Buton Jurnal Informatika Kaputama (JIK) Jurnal Informasi dan Teknologi Gravitasi: Jurnal Pendidikan Fisika dan Sains Jurnal Vokasi MOTIVECTION : Journal of Mechanical, Electrical and Industrial Engineering International Journal of Advances in Data and Information Systems Jurnal AbdiMas Nusa Mandiri Rambideun : Jurnal Pengabdian Kepada Masyarakat Relativitas : Jurnal Riset Inovasi Pembelajaran Fisika Andalasian International Journal of Applied Science, Engineering, and Technology Jurnal Janitra Informatika dan Sistem Informasi Phydagogic : Jurnal Fisika dan Pembelajarannya Journal of Renewable Energy, Electrical, and Computer Engineering Andalas Journal of Electrical and Electronic Engineering Technology Sisfo: Jurnal Ilmiah Sistem Informasi Jurnal Energi Elektrik Jurnal Teknologi Terapan and Sains 4.0 Jurnal Ilmiah Teknik Elektro Electrician : Jurnal Rekayasa dan Teknologi Elektro Jurnal Fokus Elektroda (Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali) Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika Buletin Pengabdian Journal Of Artificial Intelligence And Software Engineering Jurnal Malikussaleh Mengabdi Jurnal Polimesin Serambi Engineering Jurnal Solusi Masyarakat Dikara Akiratech Journal of Power, Energy, and Control Journal of Industrial Engineering and Management
Claim Missing Document
Check
Articles

Found 4 Documents
Search
Journal : Journal of Renewable Energy, Electrical, and Computer Engineering

Analysis of the Effect of Loading on the Transformers Usage Time Ritonga, Adi Syahputra; Muthalib, Muchlis Abdul; Daud, Muhammad; Lubis, Hamdi Akmal; Pokhrel, Biswas Babu; Phuyal, Sudip; Gohatre, Umakant B.
Journal of Renewable Energy, Electrical, and Computer Engineering Vol 1, No 2 (2021): September 2021
Publisher : Institute for Research and Community Service, Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i2.5237

Abstract

The reliability and stability of the system in the operation of the electric power system is very important, in order to provide comfort in service to consumers. The transformer is a very important component in the electric power system, because it is used as a voltage adjuster for the load being served. This study discusses the effect of loading and temperature on the life shrinkage of 36/60 MVA power transformers in block 3 and block 4 carried out at PT. PJB UBJ O&M PLTMG Arun Lhokseumawe, Aceh. From the calculation results after 4 years the transformer operates, if the transformer is given a 100% load, the transformer will experience an age difference of 2.52 p.u/day so that it has a remaining life for of 10 years. As for the transformer that is given a load of 90%, the transformer will experience an age difference of 1.44 p.u/day so that it has a remaining life to perform operations for another 18 years. Then for a transformer that is given a load of 80%, the transformer will experience an age difference of 0.67 p.u/day so that it will have a remaining life to carry out the operation again for another 38 years. From the above calculation, the origin of the temperature obtained for the ONAN type of cooler in block 3 is 0.71 p.u/day and in block 4 it is 0.70 p.u/day. While the ONAF type of cooler in block 3 is 0.004 p.u/day and in block 4 it is 0.005 p.u/day. This is in accordance with the regulation SPLN50/1982 regarding transformer life shrinkage.
Analysis of the Effect of Loading on the Transformers Usage Time Ritonga, Adi Syahputra; Muthalib, Muchlis Abdul; Daud, Muhammad; Lubis, Hamdi Akmal; Pokhrel, Biswas Babu; Phuyal, Sudip; Gohatre, Umakant B.
Journal of Renewable Energy, Electrical, and Computer Engineering Vol. 1 No. 2 (2021): September 2021
Publisher : Institute for Research and Community Service (LPPM), Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i2.5237

Abstract

The reliability and stability of the system in the operation of the electric power system is very important, in order to provide comfort in service to consumers. The transformer is a very important component in the electric power system, because it is used as a voltage adjuster for the load being served. This study discusses the effect of loading and temperature on the life shrinkage of 36/60 MVA power transformers in block 3 and block 4 carried out at PT. PJB UBJ O&M PLTMG Arun Lhokseumawe, Aceh. From the calculation results after 4 years the transformer operates, if the transformer is given a 100% load, the transformer will experience an age difference of 2.52 p.u/day so that it has a remaining life for of 10 years. As for the transformer that is given a load of 90%, the transformer will experience an age difference of 1.44 p.u/day so that it has a remaining life to perform operations for another 18 years. Then for a transformer that is given a load of 80%, the transformer will experience an age difference of 0.67 p.u/day so that it will have a remaining life to carry out the operation again for another 38 years. From the above calculation, the origin of the temperature obtained for the ONAN type of cooler in block 3 is 0.71 p.u/day and in block 4 it is 0.70 p.u/day. While the ONAF type of cooler in block 3 is 0.004 p.u/day and in block 4 it is 0.005 p.u/day. This is in accordance with the regulation SPLN50/1982 regarding transformer life shrinkage.
Design of Automatic Pond Water Quality Control in Koi Fish Farm Daud, Muhammad; Fachroji, Rizqan; Hasibuan, Arnawan; Putri, Raihan; Nratha, I Made Ari; Isa, Muzamir
Journal of Renewable Energy, Electrical, and Computer Engineering Vol. 3 No. 1 (2023): March 2023
Publisher : Institute for Research and Community Service (LPPM), Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v3i1.9730

Abstract

Koi fish is a type of freshwater ornamental fish that has high economic value. Koi fish have attractive body colors and ideal body shapes so they have good sales prospects. However, koi fish farming has several obstacles, one of which is the low recovery rate and the relatively slow growth of fish. Water quality is the main parameter in the success of a fishing effort. Therefore, this study designed a tool that can help koi fish farmers in unifying the quality of pond water so that koi fish can grow and develop properly. This monitoring system is designed by implementing an automatic control monitoring system to produce good water quality for koi fish farming. Data obtained from water quality monitoring are parameters of pH, ammonia, and water temperature. The results of this cultivator's research can monitor the quality of fish pond water and immediately get water quality control automatically.
Battery Charger Regulator With Fully Controlled Rectifier 15 V/5 A On Uninterruptable Power Supply Daud, Muhammad; Hasibuan, Arnawan; Shobirin H, Rizki; Al-Ani, Waleed Khalid Ahmed
Journal of Renewable Energy, Electrical, and Computer Engineering Vol. 3 No. 1 (2023): March 2023
Publisher : Institute for Research and Community Service (LPPM), Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v3i1.9812

Abstract

Fully controlled rectifier and Battery Charge Regulator (BCR). BCR is the main unit of UPS ( Uninterruptable Power Supply ) equipment. The fully controlled rectifier has the function of supplying voltage directly to the BCR, and the BCR has the function of regulating the battery charge. Forced charging the battery at a constant voltage with a current that matches the life of the battery will have an impact on decreasing battery life, besides that it will have an impact on the efficiency of using the battery. Controlling the input voltage of the charging battery as a function of the battery voltage is regulated by the magnitude of the charging current flow. Charging the battery via BCR is adjusted to the battery voltage so that BCR can control it by adjusting the voltage to 13.5 V for High Voltage Disconnected (HVD) and 10.5 V for Low Voltage Disconnected (LVD). Based on the test results of the performance of the full control rectifier system and BCR on a 12 V battery with a capacity of 5 Ah, it shows that the output voltage is A fully controlled 12 V rectifier, the BCR can charge an empty internal battery in a few minutes with a current varying from 2 .1 A to 0.1 A.
Co-Authors Adi Setiawan Ahmad Nayan Ainal Mardhiah Aini, Nyak Qurratu Al-Ani, Waleed Khalid Ahmed Alchalil Alchalil Ali Imran Amrizal Ananda, Rizky Andian, Andian Andik Bintoro Andre Heri Bakriansyah Anggi Chairani Ardian Ardian Arnawan Hasibuan Asran Asran Asri Asri Azhari , Fakhri Azman, Azman AZMI, AZMI Azzanna, Maghriza Badriana, Badriana Baidhawi, B Br. Simajuntak, Ochitria Cintia Chairil Pratama Chaizir, Muhammad Cindenia Puspasari Dahlan Abdullah Deassy Siska Dedi Fariadi Dery Syahputra Devi Sutri Insani Dewi Maya Sari Dirga, Muhammad Ekamaida Ervina Hasan Fachroji, Rizqan Fahmi, Mulqi Mauli Fajar Syahbakti Lukman Fajri Hakim Fajri M Kasim Fajri Yanti Fauzi Sahlan Rizki Sinaga Ferdian Ruliansyah Fuddin, Mudhya G.S, Kerimzade Gohatre, Umakant B. Gulschen Kerimzade Gunadi Habib Muharry Yusdartono Hafni, Afrilia Rizda Halimatus Sakdiah Hamdi Akmal Lubis, Hamdi Akmal Hasan, Ervina Hasanun Hasibuan, Arlina Hasibuan, Arman Heikal, Mohammad Hendrival, H Hidayatullah, Ferdy Hilmi Hilmi Hutagalung, Rizki Shobirin I Made Ari Nrartha Ichsan Ichsan Insani, Devi Sutri Irfansyah, Dedi Isa, Muzamir Ismi Raihan Karim, Firman Kartika Kartika Kerimzade, Gulschen Khaidar, Al Khairul Anshar Kurniawan, Dicky Lapara, Muhammad Ilham M Mursalin M Sayuti Mariyudi Mariyudi Mariyudi, M Maryana - Maryana Maryana Maulana, Fatur Rahman Misbahul Jannah Muchlis Abdul Muthalib MUHAMMAD ALI Muhammad Reza Muhammad Yusril Zulfikar Muhammad, Muhammad Munawarah Munawarah, Munawarah Munirul Ula Mursalin, M Mustaqim, Oka Arrizal Mutia Nanda Sari Muzamir Isa Nanda Novita Nasution, Ichsan Alwi Nisa, Hayatun Novianty, Vivi Nratha, I Made Ari Nurdin Nurdin Nurfebruary, Nanda Sitti Nurmalita Nurmalita P Purwanto Panji Aji Riha Wijayanto Phuyal, Sudip Pokhrel, Biswas Babu Puspasari, Cindeni Putra, Arwin Putri Maulina Qausar, Muhammad Qurratu Aini, Nyak Rafif, Muhammad Rahmad Rahmad Rahmat Andria Raihan Putri Raihan, Ismi Renno Kamal Putra Risna Dewi Ritonga, Adi Syahputra Rizki Suwanda Rizky Almunadiansyah Rizky Putra Fhonna Rizqan Fachroji Rizqon Hasibuan Robi Kurniawan Robi Kurniawan Roid, Fahrian Rosdiana Rosdiana Rusadi, Athirah Safina, Putri Anjali Safriana Safriana Sahal Mahfudz Said Fadlan Anshari Saifuddin Muhammad Jalil Sapto Nisworo Saputra, Rizwan Sayuti, Muhammad Selamat Meliala Shobirin H, Rizki Siregar, Umar Ramadhan Siregar, Widyana Verawaty Suhardi Makmur Suhardi Makmur Sujacka Retno Syahri, Alfis Syarifah Rita Zahara Syibral Malasyi, Syibral Taufiq Taufiq Teuku Multazam Tulus Setiawan Verawaty Siregar, Widyana Vitani Damanik Wahyu Utomo Widyana Verawaty Siregar Yanti, Fajri Yasir Amani Zalfie Ardian Zara Yunizar Zulfaini Zulfaini Zulpadli M Nasution