The Opacity of Kidney in Nephrogram Phase with Different Urea and Creatinine levels in Patients Who Undergoing Intravenous Pyelography Examination Sudiyono Sudiyono; Dwi Rochmayanti; Asri Indah Aryani
Jurnal LINK Vol 10, No 2 (2014): Mei 2014
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (488.064 KB) | DOI: 10.31983/link.v10i2.264

Abstract

The examination of intravenous pyelography (IVP) is one of the tests carried out with the aim to examine abnormalities of urinary tract anatomy and physiology. The opacity of urinary tract anatomy and function of the kidney, especially on an X-ray, is influenced by serum urea and creatinine levels of the patients prior to conducting the IVP examination. The study was an observational survey with retrospective approach. Purpose of this study was to describe the opacity of kidney picture in Nephrogram phase with different urea and creatinine levels. Urea and creatinine data were obtained from medical records of patients who underwent radiological examinations in Dr. Moewardi Hospital in 2013. The nephrogram phase imaging picture was taken from the document of Computed Radiography. The study sample was 41 patients. Data of overview kidney opacity in nephrogram phase were analyzed with Matlab software to get the value at the point calyces Pixel kidney (ROI). Research results revealed that 32 p atients (78%) of 41 patients had laboratory results of urea levels higher than normal (8-25 mg/100 ml) and 34 patients (83%) had normal creatinine levels (0.6 to 1.2 mg/ 100 ml). The results of test matlab found that opacity kidney picture nephrogram phase in patients with urea level higher than normal had a decrease of Pixel value (65220 pix.value) when compared to patients with normal urea levels (65231 pix. values ). Patients with creatinine above 1.2 mg/ 100 ml had a higher Pixel value (65239 pix.value), comparing to patients with normal creatinine levels (65219 pix.value). Further research is expected to gain more understanding. It is recommended that patients' levels of urea and creatinine should be checked in 48-72 hours before the time of IVP test, and interventions to decrease these levels should be implemented before conducting the test.
User Satisfaction Performance Analysis Of Midwives And Nurses Graduate Hospital In Semarang City And County Sri Wahyuni; Wien Soelistyo Adi; Sudiyono Sudiyono
Jurnal LINK Vol 9, No 3 (2013): September 2013
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2384.543 KB) | DOI: 10.31983/link.v9i3.304

Abstract

Quality or the quality of graduates is very important so as to provide a positive impact on the change and the prospect of graduate nursing and midwifery in the future. The changes are expected to happen to nurses and midwives in the future is as a figure of professional nurses and midwives, to improve the quality of health service quality so as to give satisfaction to masyarakat.Tujuan research is Knowing user satisfaction on the performance of graduates of midwife-nurse at City Hospital and the District of Semarang. This study is correlational research with cross sectional approach. The research instrument used structured questionnaires Total sample 140 respondents (patients), and 70 assessments of the respondents (supervisor) on graduates (midwives and nurses) working in the department of Dr Kariadi Semarang, Semarang Tugurejo Public Hospital and the hospital district Ambarawa Semarang. the purposive sampling technique sampling with proportional allocation. Bivariate analysis using Pearson product moment test. The results show that the graduates have a long working period ( 5 years) that a number of 44 (62.9%), with a Diploma III education. There was a strong correlation between the perception of the user (and the patient's immediate supervisor) about the quality of health worker's satisfaction with the results of the p value 0.0001 persessi the higher the quality, the higher the satisfaction. Needs to be done coaching, motivation to midwives and nurses to improve the performance of health care based on competence good knowledge, attitudes and skills, so as to give satisfaction to the user.
Radiation Dose Acceptence on Thorax Photos at Adult Patient Dwi Rochmayanti; Darmini Darmini; Sudiyono Sudiyono
Jurnal LINK Vol 10, No 3 (2014): September 2014
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3700.843 KB) | DOI: 10.31983/link.v10i3.83

Abstract

This study aims to describe wheter or not the patients' chest x-ray in hospital over Semarang are already has an appropriate radiation dose. This quantitative study was conducted with descriptive analysis. Data were collected by random sampling technique. The method in the measurement of patient dose was using Thermoluminesensi Dosimean meter (TLD) which is placed at the central point (CP). Profile picture over of chest radiation dose in adult patients to the 1st hospital was an average of 0.2139 mGy , 0.0758 mGy in 2nd hospital, and 0.3548 mGy in 3rd hospital . From the overall sample, the average adult chest x-ray dose was 0.1731 mGy. From these data it is concluded that the dose was still below the reference dose (0.4 mGy) , but the application of radiation protection programs and quality control diagnostic tool should still be on the run.